| 1 | Supply & Installation of 3 phase ISI marked submersible motor pump set ofthree star or better rating of BEEand as per IS: 8034-2018 (pump) and IS 9283-2013 (motor) or as amended up to date of approved make of following duty condition with required accessories including making connection suitable for tube well/DCB. The job includes lowering of motor pump, installation of complete fitting & accessories, jointing of electrical cables up to switch board, testing of submersible pump set and interconnection up to water mains, complete in all respect. |
| 2 | 7.5 KW (10 HP) & head above 120 mtr. |
| 3 | 9.3KW (12.5 HP) & head above 120 mtr. |
| 4 | 11 KW (15 HP) & head above 120 mtr. |
| 5 | 13 KW (17.5 HP) & head above 120 mtr. |
| 6 | 15 KW (20 HP) and above, head above 120 mtr. |
| 7 | Providing, installation, testing and commissioning of Centrifugal Monoblock pump set conforming to IS 9079 , 2 pole motor operating at synchronised speed of 3000 RPM with requisite MOC impeller, priming funnel, cock, suitable flanges at suction and delivery side. Pump shall have common shaft for pump and motor. Motor shall be suitable for working on 415 V ± 10%, 3 Ph, 50 Hz A.C. Supply. Motor shall be TEFC type and Pump set shall be suitable for working at various discharge and head requirements as per scope of work. Pump shall be erected onC.C. foundation / cross channels / RSJ frame block with suitable foundation bolts grouted in C.C. foundation block etc. complete in all respect as perspecification, scope of work and direction of Engineer in Charge of following power rating, suitable for prescribed duty conditions mentioned in TD. |
| 8 | Centrifugal Monoblock Pump set (Single Stage) |
| 9 | 2.2 KW (3.0 HP) |
| 10 | 3.7 KW (5.0 HP) |
| 11 | 5.5 KW (7.5 HP) |
| 12 | 7.5 KW (10 HP) |
| 13 | 9.3 KW (12.5 HP) |
| 14 | 11.0 KW (15 HP) |
| 15 | 15.0 KW (20.0 HP) |
| 16 | 18.5 KW (25.0 HP) |
| 17 | Supply and Fixing of electric control feeder panel comprising of suitable rating MCCB , fully automatic star-delta starter, over load relay,ampere meter with CTs, volt meter, phase preventer, suitable starting capacitors, phase indicators, lighting arrangement etc. complete suitable for three phase pump set. The panel should have space for energy meter ( supplied by DISCOM).All these equipments shall be housed by panel box made out from 18 gauge M.S. Sheet with powder coating. Panel should be ofminimum size 900 x 600 x 450 mm with Stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg’s length 18\" and double door including in built locking system.The legs should be embedded in M-15 cement concrete plat form. The size of CC platform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level. The panel should have opening of suitable size in front of space for energy meter with glass for meter reading. The operation of panel should be suitable for on 440 Volt AC Supply. |
| 18 | Above 5 HP and up to 10 HP |
| 19 | Above 10 HP and up to 15 HP |
| 20 | Above 15 HP |
| 21 | Providing & Lowering in tube well ISI marked GI Pipe medium duty (“B\" class), Steel tube as per IS:1239 or amended up to date and zinc coating as per IS 4736, threaded and double flanged (welded) on both ends and two number25x3mm MS flat welded on both ends between pipe & flange, rubber washer & nut bolts etc. complete in all respect. |
| 22 | 32 mm dia |
| 23 | 50 mm dia |
| 24 | 65 mm dia |
| 25 | 80mm dia |
| 26 | Supply & Fixing of ISI marked three core PVC flat submersible cableas per IS 694:1990 or amended up to date and conductor as per class 5 of IS 8130:1980including making connection etc. |
| 27 | 3 core 4.0 Sq.mm |
| 28 | 3 core 6.0 Sq.mm |
| 29 | 3 core 10.0 Sq.mm |
| 30 | 3 core 16.0 Sq.mm |
| 31 | Supply & Fixing XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Armoured of IS:7098-I/1554-1 approved makein ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick underlayer ofsand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size. |
| 32 | 10.0 Sq.mm, 4 core |
| 33 | 16.0 Sq.mm, 4 core |
| 34 | 25.0 Sq.mm, 3.5 core |
| 35 | 35.0 Sq.mm, 3.5 core |
| 36 | Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminummaterial with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass coverand secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver& has a unique BIS R number withInput Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driverEfficiency >85%,THD(I) <10%Humidity 10% to 90% RH Working Temp -5C to 45C .driver current <750mA. The luminaireshall be BIS certified and Trade mark certified. Life ExpectancyEqual or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs.Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities forLED fixtures.(LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . |
| 37 | LED Street Light fixture with Minimum lumen output 3700 lm |
| 38 | LED Street Light fixture with Minimum lumen output 12500 lm |
| 39 | LED Street Light fixture with Minimum lumen output 5600 lm |
| 40 | LED Street Light fixture with Minimum lumen output 7500 lm |
| 41 | LED Street Light fixture with Minimum lumen output 8700 lm |
| 42 | LED Street Light fixture with Minimum lumen output 11225 lm |