| 1 | Labour only for attending complaints of unserviceable ceiling fans, exhaust fans and its allied electrical repairs at domestic area of AF station Jodhpur (Outer and Inner domestic area) carrying out necessary repairs at site by replacing unserviceable spares or taking down carefully unserviceable ceiling fan/Exhaust fan by disconnecting electrical connections, unsecrewing from position, dismantling blades and removing fan and blade to workshop for carry out necessary repairs or deposit unrepairable fans/ex-fans to E/M Store yard for safe coustody all as directed and specified. All connecting wiring shall be PVC insulated single core stranded copper condutor of size 0.5 sqmm with proper color coding drawn through heat insulation sleeves of suitable size.Note : Necessary spare parts required to repair at site shall be measured and paid separately under relavant items.Necessary deposit receipt shall be provided to users for taken down fan/exhuast fan as per prescribed printed format to be arranged by contractor. Contractor shall arrange necessary transportaion to bring the taken down ceiling/exhaust fans for repair/replacement. |
| 2 | M&L for re-winding of burnt ceiling fans by opening covers of ceiling fan, remove the burnt winding, cleaning the slots and rewinding the fan with supper enammeled copper wire of same wire gauge, warnishing after winding, drying, replacing unserviceable fan bearings No 6201/6202 for 1200/1400mm sweep, greasing, soldering the copper terminal of winding with single core copper multistraded wire of 0.5 sqmm and re-assembling fan, replace of fan capacitor 2.5 mfd and making connection with fan capacitor and connector block, transporting back after repair, assembling the blades and hanging the fan in its own position to existing fan clamp and down rod with necessary Nut, bolt and washer and testing for smooth functioning after complete repair all as ditrected at site.Note :1.Quoted rates shall deems to be inclusive cost of warnish, insulation papers, sleeves,bearing /bush,capcitor, cotton tape for binding coils including minor spare like nuts, washer, screws, tension spring required for assembiling and fixing fans in position. 2. Fan re-winding & replaced bearings will be inspected by Engr-in-Charge before assembling the fan motors. |
| 3 | M&L forre-winding of burnt ex-haust fan/wall fans motor of following size sweep fans by opening covers by unscrewing nuts/screws, remove the armeture shaft and checking for its defects, checking defects in stator core & widings, cutting burnt widing of stator, cleaning the slots and rewinding the fan with supper enammeled copper wire of same wire gauge, warnishing after winding, drying, replacing unserviceable fan bush/bearings, greasing, replace of armeture coil with complete shaft if required, soldering the copper terminal of winding with single core copper multistraded wire of 0.5 sqmm and re-assembling fan, replace of fan capacitor 2.5/4.0mfd and making connection with fan capacitor and connector block, re-assembling fan exhaust fan with frame and blade, transoporting back after repair, fixing the exhust fan in its own position to existing fan clamp or with new screws and guttis or necessary Nut, bolt and washer and testing for smooth functioning after complete repair all as ditrected at site.All connecting wiring shall be PVC insulated single core stranded copper condutor of size 0.5 sqmm with proper color coding drawn through heat insulation sleeves of suitable size.Note :1.Quoted rates shall deems tobe inclusive cost of warnish, insulation papers, sleeves, cotton tape for binding coils including minor spare like nuts, washer, screws, tension spring required for assembiling fans.2.Exhaust fan bearing/bush, blade, frame & capacitor if required shall be measured and paid seperately under relavant item.3.Armeture coil with complete shaft if required shall be measured and paid separately under relavant item. 4. Fan re-winding & replaced Armeture will be inspected by Engr-in-Charge before assembling the fan motors. |
| 4 | Exhaust fan motor of 300mm sweep exhaust fans |
| 5 | Exhaust fan motor of 450mm sweep exhaust fans |
| 6 | Exhaust fan motor of 400/450mm sweep wall fan/pedestal fans |
| 7 | Supply only in repairs fan bearing of size 6101 suitable for ceiling fan 1200/1400mm sweep |
| 8 | Supply only in repairs fan bearing of size 6202 suitable for ceiling fan 1200/1400mm sweep |
| 9 | Supply only in repairs fan capacitor 2.5 Mfd suitable for ceiling fan 1200/1400mm sweep |
| 10 | Supply only in repairs fan capacitor 4.0 Mfd suitable for exhaust fan 300/450/600mm sweep. |
| 11 | Supply only in repairs fan down rod 18 inch long for hanging ceiling fan 1200/1400mm sweep. |
| 12 | Supply only in repairs fan down rod 21 inch long for hanging ceiling fan 1200/1400mm sweep. |
| 13 | Supply only in repairs fan down rod 24 inch long for hanging ceiling fan 1200/1400mm sweep. |
| 14 | Supply and fixing Anti suicide fan down rod 15 inch long for hanging ceiling fan 1200/1400mm sweep. |
| 15 | Supply and fixing Anti suicide fan down rod 18 inch long for hanging ceiling fan 1200/1400mm sweep. |
| 16 | M&L for cutting holes 300mm diameter for preaparing opening through brick/stone masonary wall for fixing exhaust fan 300mm sweep, making good to damaged surface of wall, make a smooth circular surface and match with specification of existing wall all as directed by Engr-in-charge at site |
| 17 | S&F Exhaust fan 450 mm sweep, heavy duty, metal body, four blade, air delivery shall not be less than 350 CFM at 1440 RPM mounted in suitable opening arrangement with louvers shutters suitable for operation on 240 volt, single phase, 50 cycle per second, AC supply and connecting up including provision of flexible PVC conduit from ceiling rose or connector to fan to cover PVC cable including writing MES No with black paint as directed by engr-in-charge and fixed in position as recommended by manufacturer complete all as specified. |
| 18 | S&F Exhaust fan 300 mm sweep, heavy duty, metal body, four blade, air delivery shall not be less than 350 CFM at 1440 RPM mounted in suitable opening arrangement with louvers shutters suitable for operation on 240 volt, single phase, 50 cycle per second, AC supply and connecting up including provision of flexible PVC conduit from ceiling rose or connector to fan to cover PVC cable including writing MES No with black paint as directed by engr-in-charge and fixed in position as recommended by manufacturer complete all as specified. |
| 19 | S&F Exhaust fan 300 mm sweep, made of sturdy engineering plastic, air delivery shall not be less than 350 CFM at 1440 RPM mounted in suitable opening arrangement with louvers shutters suitable for operation on 240 volt, single phase, 50 cycle per second, AC supply and connecting up including provision of flexible PVC conduit from ceiling rose or connector to fan to cover PVC cable including writing MES No with black paint as directed by engr-in-charge and fixed in position as recommended by manufacturer complete all as specified. |
| 20 | S&F Exhaust fan 250 mm sweep, made of sturdy engineering plastic, air delivery shall not be less than 350 CFM at 1440 RPM mounted in suitable opening arrangement with louvers shutters suitable for operation on 240 volt, single phase, 50 cycle per second, AC supply and connecting up including provision of flexible PVC conduit from ceiling rose or connector to fan to cover PVC cable including writing MES No with black paint as directed by engr-in-charge and fixed in position as recommended by manufacturer complete all as specified. |
| 21 | M&L for taking out old unserviceable lovers shutters of exhaust fans 300/350 mm diafrom external face of walls from double/tripple storey buildings and providing aluminium wire mesh (3 to 4 mm mesh) with Aluminium frame (Guage thickness not less than 1.2mm) including necessary fixing accessories (likeclamps, screws, wahsers, gutties etc) to prevent entry of birds/insects through opening of exhaust fans on walls. Approximate size of frame tobe provided at site is 400mm x 400mm for 300mm dia openings holes and 600mm x 600mm for 450mm dia openings holes. Note : Necessary T&P such as ladders, safety belts, drilling equiptments for fixing Wiremesh at heights of double/tripple storey building shall be arranged by the contractor and cost for the same deems tobe included in quoted rates. |
| 22 | M&L for taking out old unserviceable lovers shutters of exhaust fans 450 mm dia from external face of walls from double/tripple storey buildings and providing aluminium wire mesh (3 to 4 mm mesh) with Aluminium frame (Guage thickness not less than 1.2mm) including necessary fixing accessories (likeclamps, screws, wahsers, gutties etc) to prevent entry of birds/insects through opening of exhaust fans on walls. Approximate size of frame tobe provided at site is 400mm x 400mm for 300mm dia openings holes and 600mm x 600mm for 450mm dia openings holes. Note : Necessary T&P such as ladders, safety belts, drilling equiptments for fixing Wiremesh at heights of double/tripple storey building shall be arranged by the contractor and cost for the same deems tobe included in quoted rates. |
| 23 | M&L for Painting of ceiling/exhaust fans complete with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc and writing MES No with black paint as directed by Engr-in-Charge. Note : Painting of ceiling fans tobe carried when the body is opened for repair works for re-winding to avoid bearing Jam due to paint and motor shall be assebled after drying of paint. |
| 24 | S&F Stepped type electronic fan regulator, switch size, flush type 230V AC. |
| 25 | S&F electronic fan regulator modular stepped type 120 watt, two module. |
| 26 | S&F Stepped type Modular /Non Modular electronic fan regulator, switch size, flush type 230V AC,for BLDC fans and supporting to all type ceiling fans .Note-Regulator should work on BLDC Fans and as recommended by Engineer-in charge. |
| 27 | Supply and fix in repairs Heating element copper body chromium plated ofrating 1.5 KW, 230 voltsISI marked, 10 inch long, and dia of tube not less than 8.5mm, triangular or cup type base including rubber washer suitable for old pattern geysers complete all as specified and as directed by Engineer-in-charge. Make-Bajaj/Airex/HotMax/Crompton/Venus or any other equivalent approved make. |
| 28 | Supply and fix in repairs Heating element copper body chromium plated ofrating 2.0 KW, 230 voltsISI marked, 8/10 inch long, and dia of tube not less than 8.5mm, triangular or cup type base including rubber washer suitable for old pattern geysers complete all as specified and as directed by Engineer-in-charge. Make-Bajaj/Airex/HotMax/Crompton/Venus or any other equivalent approved make. |
| 29 | Taking down carefully copper/aluminum point wiring (Light/ fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc, stacking at site for reuse or removing materials to store for keeping in for taking credit and making good the disturbed surfaces / walls/ floors etc. |
| 30 | M&L for point wiring with 2.5 Sq. mm, multi-stranded copper conductor, single core, PVC insulated and unsheathed cable for phase and neutral, including 2.5 Sq. mm PVC insulated unsheathed multistranded copper conductor single core cable as earth continuity conductor (in green color) connected to common earth dolly, drawn in and including PVC Casing and Caping, GI terminal boxes 1.2mm thick fixed flush to wall surface, covered with & including 3 mm thick plastic laminated sheet top cover for mounting switch and sockets etc. complete all as specified and directed . |
| 31 | M&L for point wiring with 4 Sq. mm, multi-stranded copper conductor, single core, PVC insulated and unsheathed cable for phase and neutral, including 4 Sq. mm PVC insulated unsheathed multistranded copper conductor single core cable as earth continuity conductor (in green color) connected to common earth dolly, drawn in and including PVC Casing and Caping, GI terminal boxes 1.2mm thick fixed flush to wall surface, covered with & including 3 mm thick plastic laminated sheet top cover for mounting switch and sockets etc. complete all as specified and directed . |
| 32 | S&F(in repairs) Switch Socket combination outlet 6 pin, 6/16 Amp, flush type |
| 33 | Supply and fix in repairs 3 Pin Plug Top 16 Amps, 240 volt insulated bakelite body(Ivory/White) |
| 34 | Supply and fixing MCB single pole 6-32 Amps, 240 volts, 10 kA rupturing capacity providing in DB complete including connection & testing all as specified. |
| 35 | Supply and replace sheet metal enclosures with socket plug top, and MCBs single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB upto 20 Amps, 240 Volt capacity fixed flush to wall surface including making good to damaged surface of wall to match with existing specification and tested on completion completeincluding taking out old all as directed. Make -L&T ,Legrand,havells |
| 36 | Supply and fix in repairs metal clad, 2 Pin+Earth Plug SOCKET only 16 Amps, 240 volt. |
| 37 | Supply and fix in repairs metal clad, 2 Pin+Earth Plug Top 16 Amps, 240 volt. |
| 38 | Supply and fix in repairs Thermostat (8/10 inch long) auto cut with thermal setting upto 80 degree centigrade, 230 V, for the geysers 25/50Ltrs capacity as per site requirement fixed in repairs complete all as specified and as directed by Engr-in-Charge . |
| 39 | Supply and fix in repairs capillary type Thermostat suitable for new gernation energy efficient geyser for tempterature control auto cut function, 230 V,size and capacity as per site requirement complete all as specified and as directed by Engr-in-Charge . |
| 40 | M&L for replacement of HOT & COLD PVC water connection pipes stainless steel braided flexible pipe 450mm long as per Cat No GSSGGX0030 of Make Havells or equivalent in approved makes. |
| 41 | Supply and fix in repairs Heat resistant heavy duty pressure grade 6 kg/sq cm, stainless steel wiremesh braided HOT & COLD flexible PVC connecting pipe with brass adapters 600 mm long suitable for 15 mm dia pipe and fixed in position as in repairs complete all as approved by Engineer-in-charge. Make-Havells/Crompton or as per approved makes. |
| 42 | M&L for point wiring with 1.5 Sq. mm, multi-stranded copper conductor, single core,FRLSH PVC insulated and unsheathed cable for phase and neutral, including 1.5 Sq. mm PVC insulated unsheathed multistranded copper conductor single core cable as earth continuity conductor (in green color) connected to common earth dolly, Concealed wiring , GI terminal boxes 1.2mm thick fixed flush to wall surface, covered with & including 3 mm thick plastic laminated sheet top cover for mounting switch and sockets etc. complete all as specified and directed for following : - |
| 43 | One light point/exhaust fan point controlled by one switch or one ceiling fan point controlled by one switch & electronic type fan regulator. |
| 44 | One light point controlled by two Nos 5 Amps switch two way |
| 45 | One 3 pin 5 Amp switch & socket outlet on same board with other switches. |
| 46 | One 3 pin 5 Amp switch & socket outlet on Independant board. |
| 47 | One bell point controlled by one switch 5 Amps bell push. |
| 48 | All same as per item ser No 39.00here-in-above but wiring using 2.5 sqmm multi-stranded copper conductor, single core,FRLSH, PVC insulated and unsheathed cableing(including concealed wiring and conduit into groove cutting ), including 2.5 Sq. mm PVC insulated unsheathed multistranded copper conductor single core cable as earth continuity conductor (in green color) connected to common earth dolly for 6 pin, 15/16 Amps socket outlet on independant board. |
| 49 | All same as per item ser No. 39.00 here-in-above but wiring using 4.0 sqmm multi-stranded copper conductor, FRLSH,single core, PVC insulated and unsheathed cable,(including concealed wiring and conduit into groove cutting ) including 4.0 Sq. mm PVC insulated unsheathed multistranded copper conductor single core cable as earth continuity conductor (in green color) connected to common earth dolly for two pin earth metal clad plug & socket point for AC/Geysers. |
| 50 | S&F switch modular single pole one way 6 Amps 230 volt 1 module. |
| 51 | S&F switch modular single pole one way 16 Amps 230 volt 1 module. |
| 52 | S&F Socket modular 6 Amp 2/3 pin combined two module. |
| 53 | S&F Socket modular 6&16 Amp 2/3 pin combined two module. |
| 54 | S&F modular Ceiling rose modularsurface bakelite 65x50mm three terminal. |
| 55 | S&F modular Lamp holder insulated PVC/Polycarbonate/bakelite body, fixed on PVC round or squre box using necessay screw & gutti complete allas specified. |
| 56 | S&F modular electronic Bell Bul-Bul music, 230 volt, single phase. |
| 57 | S&F modular bell push,type, 6 Amps, 2 Module |
| 58 | S&F modular white or Ivory cover plate with frame 1 module |
| 59 | S&F modular white or Ivory cover plate with frame 2 module |
| 60 | S&F modular white or Ivory cover plate with frame 3 module |
| 61 | S&F modular white or Ivory cover plate with frame 4 module |
| 62 | S&F modular white or Ivory cover plate with frame 6 module |
| 63 | S&F modular white or Ivory cover plate with frame 8 module |
| 64 | Taking out existing unserviceable switch board plates any type, dismantling switches cafully, stacking at site for use of serviceable switches and supply and fixing new 3mm thick masonite laminated sheet top cover fixed on 6/8 inch x 10 inch MS box and brass screw for mounting switches, sockets, regulator etc including making necessary electrical connection with1.5 sqmm single core copper mulitstranded cable all as directed at site by Engineer-in-charge.Note :New Switches, sockets, fan regulators etc if required will be measured and paid separately under relevant items. |
| 65 | All as per item ser No 56.00 here-in-before but new 3mm thick masonite laminated sheet top cover white or ivory fixed on 6/8 inch4 inch MS box. |
| 66 | All as per item ser No 56.00 here-in-before but new 3mm thick masonite laminated sheet top cover white or ivory fixed on 4 inch x 4 inch MS box. |
| 67 | Supply and fixing in repair of LED lights fitting 1x 20W, 220V,AC aluminium body decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.make-philips,havells ,crompton |
| 68 | Supply and fixing in repair of LED lights fitting 1x 10 W, 220V,AC aluminium body decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.make-philips,havells ,crompton |
| 69 | Supply and fixing in repair of LED surface round shape lights fitting 1x 10 W, 220V,AC aluminium body decorative box type with driver, with three core flexible copper conductor cable of suitable size from ceiling rose complete.make-philips,havells ,crompton |
| 70 | S&F LED light fitting in repair of 1 x 10W bulkhead luminaires including inbuild LED light driver perfect interior and exterier application connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. |
| 71 | Supply and fixing i-sense smart LED serene recess mounting35 watt,inbuilt sensor based smard LED auto dimming option from 100% to 25% of the rated voltage ,recess mounted serene 2x2 made from CRCAsheet ,white powder coated housing,opaque polycarbonate diffuser for optimum and glare free light outputincluding connecting up with driver three core flexible copper conductor cases ofsuitable size complete all as perapproved makes. |
| 72 | Supply and fixing in repair LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases ofsuitable size complete all as per crompton cat ref no. LCTLR-36-FO-CDL or equivalent inapproved makes. |
| 73 | S&F in repair Building security light fittings, with pressure die cast aluminium housing, suitable for 25 W LED,complete pre-wired, incl suitable bracket for fixing light on wall or any indicated locaction all as specified and as directed by Engr - in Charge complete all as per Havells Cat No: ENDURAPEARLSL25W or equivalent model approved makes. |
| 74 | M&L for MCB TPN/FP, 100 Amps 415 volts, 10 kA rupturing capacity providing in DB complete including connection & testing all as specified.Make -L&T ,Legrand,havells |
| 75 | Supply and replace sheet metal enclosure distribution board for 240 volts, 12 way horizontal type, double door, single pole and neutral with 200 Amps rated neutral copper bus bar for housing MCB and fixed flush in wall surface, and tested on completion completeincluding taking out old all as directed.Make -L&T ,Legrand,havells |
| 76 | Supply and replace sheet metal enclosure distribution board for 240 volts, 8 way horizontal type, double door, single pole and neutral with 200 Amps rated neutral copper bus bar for housing MCB and fixed flush in wall surface, and tested on completion completeincluding taking out old all as directed.Make -L&T ,Legrand,havells |
| 77 | M&L for MCB SPN/DP 40 to 63 Amps 240 volts, 10 kA rupturing capacity providing in DB complete including connection & testing all as specified.Make -L&T ,Legrand,havells |
| 78 | M&L for Sub main wiring as per IS, single core FRLSH PVC insulatedflexible multistranded copper conductor,FRLSH, 1.1 KV grade drawn through & including PVC grey conduit heavy duty with necessary accessories (like bend, juction boxes etc) including taking down old unsv submain wiring complete all as specified for Two runs of 2.5 Sq.mm main Phase-Neutral supply cable alongwith one run of single core 2.5 Sq.mm for continuous earth wire in green color. |
| 79 | M&L for Sub main wiring as per IS, single core FRLSH PVC insulatedflexible multistranded copper conductor,FRLSH, 1.1 KV grade drawn through & including PVC grey conduit heavy duty with necessary accessories (like bend, juction boxes etc) including taking down old unsv submain wiring complete all as specified for Two runs of 4.0 Sq.mm main Phase-Neutral supply cable alongwith one run of single core 4.0 Sq.mm for continuous earth wire in green color. |
| 80 | M&L for Sub main wiring as per IS, single core FRLSH PVC insulatedflexible multistranded copper conductor,FRLSH, 1.1 KV grade drawn through & including PVC grey conduit heavy duty with necessary accessories (like bend, juction boxes etc) including taking down old unsv submain wiring complete all as specified for Two runs of 6.0 Sq.mm main Phase-Neutral supply cable alongwith one run of single core 6.0 Sq.mm for continuous earth wire in green color. |
| 81 | M&L for Sub main wiring as per IS, single core FRLSHPVC insulatedflexible multistranded copper conductor,FRLSH, 1.1 KV grade drawn through & including PVC grey conduit heavy duty with necessary accessories (like bend, juction boxes etc) including taking down old unsv submain wiring complete all as specified for Two runs of 10.0 Sq.mm main Phase-Neutral supply cable alongwith one run of single core 6 Sq.mm for continuous earth wire in green color. |
| 82 | Material and labuor for earthing complete with Galvanized Steel earth plate electrode 600x600x6mm thick buried directly in ground (earth pit not less than 2.25 M deep below ground level) with top edge of the plate not less than 1.5 M below normal ground level and filled with 15cm thick alternate layers of charcoal and salt, connected & including GI wire earth lead 4.0mm dia by means of bolts, nuts, check nuts and washers made of galvanized iron protected by 15mm dia GI Pipe (light grade). Earth plate shall be surrounded by alternate layers of charcoal or coke and common salt in 15cm thick in layers & 15cm of widht all aurround of earth plate including 20mm dia GI light grade pipe for watering and including funnel, wire mesh, necessary earth work in any type of soil, Pre-cast RCC cover duly re inforced with 8mm dia TMT Bar @150 mm c/c both ways, one lifting handle made of 8 mm dia TMT bar embedded in cover slab, Earth Pit of PCC (1:3:6) type C2 (using 20mm graded crushed store aggrgate)complete all as specified and as shown in electrical plate No-3 of SSR Part-I including testing on completion.Note:- (i)PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) The unit rate includes earthing lead & protection pipe upto 7.5 metre from top of earth plate. |
| 83 | Note for Item No 1.0 to 75.00 :-(a)The contractor will deploy sufficient resources for completion of day to day comaplaint/ complaint of fan & Geysers within 24 Hrs from the time of reporting.Any delay beyond above mentioned time limit suitable penalties as mentioned in relavant clause of Contract.(b)A detailed log of complaints with completion/non-completion remarks from users/MES will be maintained by the contractor and same will be updated on daily basis in consulatation with Engr-in-Charge or JE detailed by him.(c)The contractor will make suitable arrangment for emergent complaints and will notify JE/Engr-in-Charge about extraordinary circumstances for probable non-completion or delay in rectification of complaints beyond state time limit set for disposal of complaint.In case of any dispute the decision of accepting officer will be final and binding in this regard.(d)The contractor will intimate MES authority well in advance if electric shutdown is required during rectification of complaints.(e)The quoted rated deems to be inclusive of transportation, T&P and other expenses required for the resource deployment at the complaint site around scattered at AF Station Jodhpur.(f) The contractor will maintain suitable inventories and range of spares required to meet the complaints as same will be reviewed periodically by Engr-in-charge or JE detailed by him to streamline complaints disposal system. |