| 1 | PART A CIVIL WORK |
| 2 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. In mud mortar |
| 3 | Demolishing mud phuska/ Lime dhar/ Kharanjain terracing and disposal of unserviceable material within 50 meters lead. |
| 4 | Dismantling Jack arch roofing and floors including stacking of serviceable material and disposal of unserviceable material within 50-meter lead. |
| 5 | Dismantlingsteelworkinsinglesectionsincludingdismemberingandstackingwithin 50 meters lead in:R.S. Joists. |
| 6 | Brick work with common burnt clay F.P.S.(Non Modular) bricks of class designation 7.5 in superstructure above plinth level upto floor five level in all shapes and sizes in :Cement mortar 1 : 6 (1 cement : 6 coarse sand) |
| 7 | Supply & Stacking good earth at site complete including loading unloading & transporation etc. Filling available excavated earth (excluding rock) in trenches, plinth side of foundation etc. in layers not exceeding 20 cm. in depth , consolidatingeach deposited layer by ramming and watering including lead upto 50Mtr. and lift upto 1.5Mtr. |
| 8 | Roof Slab & Beams :- Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor five level for :Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates,anchorblocks,sills,chhajjas,lintel,beam, plinth beam etc. |
| 9 | Roof Slab & Beam :- Providing and laying in position specified grade ofcement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcementfor Beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases etc.M20 grade Nominal Mix / Design Mix |
| 10 | Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor three level. Thermo-mechanically Treated bars (Conforming of relevent IS code) |
| 11 | Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded with 15x3 mm lugs 10 Cm. long embedded in cement concrete blocks 15x10x10 Cm. of 1:3:6 (1-Cement:3-coarse sand:6-graded stone aggregate 20 mm nominal size) or with wooden plugs and screws or rawl plugs and screws or with fixing clips or with bolts and nuts as required including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. Door and chokhat 40 x 40 x 5 mm |
| 12 | Providing And Fixing Steel Glazed Doors Windows And Ventilator With Shutters Of Standard Rolled Steel Section Joints Mitred And Welded With Steel Lugs 13x13 Mm, 10 Cm. Long Embedded In Cement Concrete Block 15x10x10 Cm Of 1:3:6 (1 Cement:3 Course Sand:6 Graded Stone Aggregate 20 Mm Nominal Size) Or With Wooden Plugs And Screw Or Rawl Plungs And Screws With Fixing Clips Or With Bolts And Nuts As Required Including Providing Adn Fixing Of Plain Glass Panes 4 Mm Thick With Coper Glazing Clips And Special Metal Sash Putty Of Approved Make Or Metal Beading With Screws Complete Including The Cost Of Metal Beading And Other Fitting Except Necessary Hings Of Pivots Steel Handles Peg Stay Etc. As Required As Per Is:1038 |
| 13 | P&F M.S. Sheet Double Leaf Door Shutter In Angle Iron Frame 35 x35 x 5mmSuitability Diagonally Braced With 25*3mm Flat Iron Above And Below Lock Rail Of Size 50 x 5mm Beading Extra Including All Fittings As Per Direction Of Chokhats But Excluding Cost Of Chowkhats18 SWG MS Sheet |
| 14 | P&F Guard Bars For Windows & Bottom Of Doors Frame. |
| 15 | Providing and fixing welded mesh/expanded metal mesh in frame work, flat iron beading 20x3mm including top cross laps inside and out sides welding, iron bolts, crews, clips etc. complete (excluding frame work) of size.Welded mesh 50 mmx 50 mm x 2.1 mm |
| 16 | 6 mm cement plaster to ceiling of mix 1:3 (1 cement :3 corse sand) Slab Down BeamRoof |
| 17 | Internal Plaster--Plaster On New Surface On Walls In Cement Sand Mortar 1:6 IncludingRacking Of Joint Etc. Complete Fine Finished. 12mm Thick |
| 18 | External Plaster -Plaster On New Surface On Walls In Cement Sand Mortar 1:6 IncludingRacking Of Joint Etc. Complete Fine Finished. 20 mm thick |
| 19 | Making grooves as per design in plaster 10mm to 20mm wideOuter Side |
| 20 | Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. M10 grade Nominal Mix 1: 3: 6 (1 cement : 3 coarse sand : 6 graded stoneaggregate 20mm nominal size). |
| 21 | P&L 25 mm thick Polished blue kota stone flooring Skirting laid Over 20 mm thick base of CM 1:4 & jointed with grey cement slury math the shade of slabe incld rubbing and polishing complete. Size 2001-5000 sqcm. |
| 22 | Providing and laying cement concrete including curing, compaction etc. complete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, levelling course etc up to floor five level excluding the cost of centering and shuttering.M15 grade Nominal Mix 1: 2: 4 (1 cement : 2 coarse sand : 4 graded stoneaggregate 20mm nominal size). |
| 23 | Grading roof for water proofing treatment withwater proffing compound Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 24 | Providing batta (gola) 75mm x 75mm in cement concrete (1:2:4) including finished with cement mortar 1:3 as per standard design. |
| 25 | Finishing walls with water proofing cement paint of required shade including all scaffolding.:New work (Two or more coats applied @ 3.84 kg/10 sqm). Qty asper Plaster 6 mm + 12 mm + 20 mm |
| 26 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on New Work |
| 27 | PART B SANITARY WORK |
| 28 | P&F rigid 110 mm dia pvc pipe class IInd (4kg./cm2) approved quality make including jointing the pipe with solvent cement rubber rim & lubricant . |
| 29 | PART C ELECTRIC WORK |
| 30 | Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)inrecessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & it\"sISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thickHot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheet\"s & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR |
| 31 | Short point (up to 3 mtr.) |
| 32 | Medium point (up to 6 mtr.) |
| 33 | Long point(up to 10 mtr..) |
| 34 | Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) inrecessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & it\"s ISI marked (IS:3419-1988)accessories, Hot Dipped GalvanizedModular box of 1.2 mm thick with earth terminal, 10 A modularswitch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheet\"s & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR |
| 35 | S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along withISI marked (IS:3419-1988) accessories as requiredinrecessincludingcutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR |
| 36 | Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR |
| 37 | P & F 1.2mm thickM.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm,12 mm dia rod fan hook with 100 mmlength extended on each side . All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR |
| 38 | Providing & Fixing of modular type 120 W Step Fan regulator duly ISI marked (IS 11037:1984 ) with CM/L no. printedmade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating ,includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR5 step fan regulator 2 Module 360 dgree rotating |
| 39 | Supply & drawing Wiring for sub mains ISI marked (IS:694) 1100 Volts grade PVC insulated flat twin core sheathed solid aluminium conductor with 10 SWG G.I. Support wire duly clipped etc. as required. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR 10.0 sqmm |
| 40 | Providing & Fixing of IP 20 boxmade outfrom 1.2mm thick CRCA sheet steel with depth of minimun 30 mm and finished with powder coating andsuitable for mounting LED tubeincludingside covers, holders , internal wiring to illuminate the single sided connection LED tube. ( Without tube).All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR .Suitable for 4\" LED Tube shape fixturefor single rod1 X 36 Watts with EB |