Tender For Multifuctional Work ,Multifuctional Space And Open Amphi Theator. - Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. DSR 2023 2.32 2 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas(exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out anddisposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.All kinds of soil (DSR2023, 2.6.1 3 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidatingand dressing complete.All kinds of soil (DSR2023, 2.27) 4 Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos/Lindane E.C. 20% with 1% concentration 5 Providing and laying in position cement concrete of specified grade excluding the cost of centering andshuttering - All work up to plinth level :1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 40 mmnominal size derived from natural sources)All kinds of soil (DSR2023, 4.1.6) 6 Providingandlayingdamp-proofcourse4cmthickwith cementconcrete1:2:4 (1cement1:2 coarsesand:4 gradedstoneaggregate 12.5mm nominal size).DSR 2023 4.10 7 Providing & laying design mix cement concrete of M-30 grade,in roads/taxi tracks/runways, using cement concrete as per design mix,using coarse sand and graded stone aggregate of 40mm nominal size in appropriate proportions as per approved & specified design criteria,providing dowel bars with sleeve/tie bars wherever required texture, including steel form work with sturdy M.S.channel sections, curing,making provision for contraction/expansion, construction & longitudinal,joints(10mm wide x 50 mm deep) by groove cutting machine,providing and filling joints with approved joint filler and sealants, complete all as per direction of Engineer-in-charge Cement concrete prepared with batch mixing machine DSR 2023 16,43,1 8 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5above plinth level up to floor 1 level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand)DSR2023 6.1.2 9 Providing and fixing 1st quality Vitrifiedfloor tiles conforming to IS : 15622 (thickness tobe specified by the manufacturer ) of approved make in all colours, shades except burgundy,bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of stepsand dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointingwith grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed withpigment of matching shade complete.DSR2023,11.37A 10 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick DSR2023 11.26.1 11 12mm thick Cement plaster 1:4 (1 cement: 4 coarse sand) finished with a floating coat of neat cement.DSR2023 13.4.1 12 Providing and applying white cement based putty of average thickness 1 mm, of approved brandand manufacturer, over the plastered wall surface to prepare the surface even and smoothcomplete. DAR2023,13.80 13 Finishing of wall with two coat of waterproof cementpaint of snocem with one coat primer. DSR2023,13.44.1 14 Providing and fixing Stainless steel railing for staircase. 15 Supply and burying of 40mm dia x 4.5 metres long G.I. Pipe vertically for earthing having 12mm dia. Holes spaced 75mm apart drilled up to 2 metre from the bottom complete with earthing lead of No. 6 to 8SWG GI wire in G.I. Pipe up to appron (and from appron to switch board the cost of G.I. wire and pipe will be extra) upto switch board, 30cm square C.I. box with hinged cover masonary enclosure, funnel at top, alternate layers of charcoal/coke and salt at least 150mm thick alround etc. as per directions of Engineer-in-charge complete in all respects as per drawing. 16 Supply and burying of 600mm x 600mm x 6mm G.I. plate vertically for earthing with its top at least 3 metres below ground level complete with 20mm dia G.I. pipe and funnel for watering and one earthing lead of one no. 8 to 10 SWG GI wire in 15mm dia G.I. pipe up to switch board (from appron to switch board the cost of G.I. pipe and G.I. wire will be extra) 30cm square C.I. frame with hinged cover masonry housing alternate layers of charcoal/coke and salt at least 150mm thick alround etc. as per directions of Engineer-in-charge complete in all respects as per drawing (This will apply for earthing of poles also). 17 Supply and fixing of one number 8 SWG G.I. wire in 15mm dia. G.I. pipe for earthing, laid in ground or in wall duly concealed including the cost of cement, sand, labour, T&P other material required for proper completion of the work as directed at site. 18 Wiring point for light with 1.5 sq. mm.FRLSH PVC insulated multistrand single core copper conductor cable in heavy guage rigid steel conduit pipe on surface, complete with 14 SWG copper earth continuity wire,GP Box ,piano type switch and ceiling rose/angle/ batten holder on 3 mm. thick phenolic laminated backelite sheet etc. complete in all respect, as directed . 19 Supply and fixing of G.P. Modular switch box for 1 / 2 Module of approved make made up of 1.0 mm thick ISI Marked G.P.sheet including adjestable Nakka and holes plugged with PVC Nylon Caps . Two or more holes for pipe entry of 25.4 mm on upper and lower sides of the box. Holes should be semi-shuttered type and fitted with heavy brass Earth Piller duly screwed & brand name should be embossed. Box flushed in wall including cutting of brick work, fixing it to the level with cement sand mortar, including matching colour wash with s/o all materials, labour and T&P required for proper completion of work as directed at site by the Engineer in charge. 20 Same as in item 174(B) but for plug point with 5 Amp flush type switch and 3 pin socket and earth continuity wire of 1.5 sq.mm. FRLSH PVC insulated multi strand copper conductor cable. 21 Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor,single core cable in surface/recessed medium class PVC conduitas required. 2x2.5 Sq.mm + 1x2.5 Sq.mm earth wire 22 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole 23 Supply & fixing of Electric Pole with Led Light as as Per Qutation Rate 24 Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. DSR 2023 2.32 25 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas(exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out anddisposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.All kinds of soil (DSR2023, 2.6.1 26 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.All kinds of soil (DSR2023, 2.27) 27 Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos/Lindane E.C. 20% with 1% concentration 28 Providing and laying in position cement concrete of specified grade excluding the cost of centering andshuttering - All work up to plinth level :1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 40 mmnominal size derived from natural sources)All kinds of soil (DSR2023, 4.1.6) 29 Providingandlayingdamp-proofcourse4cmthickwith cementconcrete1:2:4 (1cement1:2 coarsesand:4 gradedstoneaggregate 12.5mm nominal size).DSR 2023 4.10 30 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size)DSR 2023 5.1.2 31 RCC Columns 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size)DSR 5.2.2 32 RCC T-BEAMS, SLAB, ROOF 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size) DSR 2023 5.3 33 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more DSR 2023 5.22.6 34 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5above plinth level up to floor 1 level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand)DSR2023 6.1.2 35 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor 1 level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand) DSR2023 6.4.1 36 Providing and fixing 1 mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3mm M.S. gusset plates at the junctions, and corners,all neccessary fitting complete including applying a priming coat of approved steel primer. 37 Providing and fixing M.S. grills of required pattern in frames of windowsetc. with M.S. flats, square or round bars etc. including priming coatwith approved steel primer all complete. DSR 9.48 38 Providing and fixing Stainless steel railing for staircase. 39 Providing and fixing 1st quality Vitrifiedfloor tiles conforming to IS : 15622 (thickness tobe specified by the manufacturer ) of approved make in all colours, shades except burgundy,bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of stepsand dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointingwith grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed withpigment of matching shade complete 40 Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness tobe specified by the manufacturer ) of approved make in all colours, shades except burgundy,bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of stepsand dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointingwith grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed withpigment of matching shade complete.DSR2023,11.37A 41 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick DSR2023 11.26.1 42 12mm thick Cement plaster 1:4 (1 cement: 4 coarse sand) finished with a floating coat of neat cement.DSR2023 13.4.1 43 Providing and applying white cement based putty of average thickness 1 mm, of approved brandand manufacturer, over the plastered wall surface to prepare the surface even and smoothcomplete. DAR2023,13.80 44 Finishing of wall with two coat of waterproof cementpaint of snocem with one coat primer. DSR2023,13.44.1 45 one prime coat & two coat of oil bound distemper on new work incl. supply of all material labour T&P etc DSR2023,13.41.1 46 Painting with synthetic enamel paint of approved brand and manufacture of required colour togive an even shade :DSR2023 13.99.1 47 E/W IN EXCAVATION IN ORDINARY SOIL. 48 BCC IN 1:4:8 CEMENT,F SAND AND 40MM STONE 49 BRICK WORK IN M150 IN 1:4 CEMENT AND C.SAND 50 BRICK WORK IN M150 HONEY COMB IN 1:4 CEMENT SAND 51 12 MM THICK PLASTER IN 1:4 CEMENT, COARSE SAND MORTOR INCLUDING 52 RCC WORK IN 1:1.5:3 WITH 20MM GRIT MORTOR IN SLAB. 53 MS WORK IN RCC INCLUDING CUTTING,BENDING,BINDING ETC 54 40 MM THICK CEMENT FLOORING IN 1:2:4 CEMENT CON. WITHOUT BASE. But floating coat of neat cement all comp 55 P/F 100 MM DIA PVC PIPE. 56 Providing & fixing white vitereous china water closet squatting pan ISI marked (Indian type W.C. pan) with 100mm sand cast iron P or S trap, 10/12.5 litrsPVC low level flushing cistern with fittings & brackets 40mm dia C.P. flush 57 Providing & fixing white vitereous china water closet squatting pan ISI marked (European type W.C. pan) with sit and lid,10 litrsPVC low level flushing cistern with fittings & brackets 40mm dia C.P. flush 58 Providing & fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm size with autometic flushing cistern with standard flush pipe. 59 Providing & fixing white vitreous china wash basin with C.I. brackets painted white, 15mm C.P. brass pillar taps, C.P. brass chain with rubber plug, 32mmC.P. brass waste of standard pattern including 60 Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete. 61 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. : Internal work - Exposed on wall25mm dia nominal dia pipes 62 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. : Internal work - Exposed on wall32mm dia nominal dia pipes 63 Providing and fixing 45 cm long unplasticised PVC connection pipe with brass unions. (a) 15mm nominal bore 64 Providing & fixing CP brass bib cock of approved quality conforming to IS 8931(a) 15mm nominal bore 65 Providing & fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. (a) 15mm nominal bore 66 Providing & fixing C.P. brass angle valve for basin mixer and gyser points of approved quality conforming to IS 8931 (a) 15mm nominal bore 67 Providing and fixing gun metal gate valve with wheel of approved quality. (a) 25mm dia nominal bore 68 Providing and fixing gun metal gate valve with wheel of approved quality. (d) 32mm dia nominal bore 69 Providing and fixing brass stop cock of approved quality. (b) 20 mm nominal bore 70 Providing and placing on terrace (at all floor levels) polyethylene water storage tank of approved brand and manufacture with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 71 Supply and burying of 40mm dia x 4.5 metres long G.I. Pipe vertically for earthing having 12mm dia. Holes spaced 75mm apart drilled up to 2 metre from the bottom complete with earthing lead of No. 6 to 8SWG GI wire in G.I. Pipe up to appron (and from appron to switch board the cost of G.I. wire and pipe will be extra) upto switch board, 30cm square C.I. box with hinged cover masonary enclosure, funnel at top, alternate layers of charcoal/coke and salt at least 150mm thick alround etc. as per directions of Engineer-in-charge complete in all respects as per drawing. 72 Supply and burying of 600mm x 600mm x 6mm G.I. plate vertically for earthing with its top at least 3 metres below ground level complete with 20mm dia G.I. pipe and funnel for watering and one earthing lead of one no. 8 to 10 SWG GI wire in 15mm dia G.I. pipe up to switch board (from appron to switch board the cost of G.I. pipe and G.I. wire will be extra) 30cm square C.I. frame with hinged cover masonry housing alternate layers of charcoal/coke and salt at least 150mm thick alround etc. as per directions of Engineer-in-charge complete in all respects as per drawing (This will apply for earthing of poles also). 73 Supply and fixing of one number 8 SWG G.I. wire in 15mm dia. G.I. pipe for earthing, laid in ground or in wall duly concealed including the cost of cement, sand, labour, T&P other material required for proper completion of the work as directed at site. 74 Wiring point for light with 1.5 sq. mm.FRLSH PVC insulated multistrand single core copper conductor cable in heavy guage rigid steel conduit pipe on surface, complete with 14 SWG copper earth continuity wire,GP Box ,piano type switch and ceiling rose/angle/ batten holder on 3 mm. thick phenolic laminated backelite sheet etc. complete in all respect, as directed . 75 Supply and fixing hexagonal/Round G.P.fan box of approved make made up of 1.0 mm thick ISI Marked G.P.sheet spot welded Four to Eight holes of 25.4 mm for pipe entry of the box. Holes should be semi-shuttered type with 0.5 mm G.P. Sheet made upper & lower cover duly screwed fitted with 300 mm round zink coted M.S Bar X 12 mm & brand name should be embossed. Fixing with wiring conduit laid in the R.C.C. roof before concreting alongwith supply of all material, labour, T&P etc. required for proper completion of the work. 76 Supply and fixing of G.P. Boxes/Housing for Conceaded LED / CFL Lamps 335 mm wide x 63.5 mm deep(2.5)of As per Qutation Rate 77 Supply and fixing of 2/3/4 ways round Steel junction box confirming to ISS for 20mm dia 16 gauge conduit concealed in wall, keeping its level upto plaster duly provided with proper size cover, screwed as directed at site by the Engineer I/C with supply of all material labour and T&P required for proper completion of work. 78 Supply & fixing Metal box on surface size 200mmx300mmx100mm 79 Supply and fixing of G.P. Modular switch box for 1 / 2 Module of approved make made up of 1.0 mm thick ISI Marked G.P.sheet including adjestable Nakka and holes plugged with PVC Nylon Caps . Two or more holes for pipe entry of 25.4 mm on upper and lower sides of the box. Holes should be semi-shuttered type and fitted with heavy brass Earth Piller duly screwed & brand name should be embossed. Box flushed in wall including cutting of brick work, fixing it to the level with cement sand mortar, including matching colour wash with s/o all materials, labour and T&P required for proper completion of work as directed at site by the Engineer in charge. 80 Supply and fixing of electronic fan regulator 120-280 V. ISI marked, on the existing switch board including making connections, required material, labour T&P etc. for proper completion of work to the satisfaction of Engineer in charge of work. 81 Same as in item 174(B) but for plug point with 5 Amp flush type switch and 3 pin socket and earth continuity wire of 1.5 sq.mm. FRLSH PVC insulated multi strand copper conductor cable. 82 Supply and fixing of LED Tube Light with battensuitable for up to 1 X 22 watt LED tube light fitting including tube on Surface complete in all respect. CAT-AA 83 Supply, Installation, Testing and Commissioning of 1200 mm sweep,BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC)Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. 84 Supply and fixing of recess/ Surface/ Pendentmounting round 6 Watt 8 Watt LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/ Reflector and driver set complete in all respect. CAT-A 85 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole 86 Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor,single core cable in surface/recessed medium class PVC conduitas required. 2x2.5 Sq.mm + 1x2.5 Sq.mm earth wire 87 Supply & fixing PVC 25mm dia conduit pipe all complete. 88 Supply & fixing PVC 25mm dia Bend 89 Supply & fixing furface/Flush mounting 6 ways TPN distribution board with additional metal door without MCB complete. 90 Supply & fixing of GENERAL 1.5 Ton 3 Star Inverter Split AC (2023 Model, Copper Condenser, ASGG18CPAA-B) As per Qutation Rate