| 1 | [11.69.2]Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. 2. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre [Through Rate] |
| 2 | [11.78]Painting two coats excluding priming coat with synthetic enamel paint in all shades on new wood work or metallic or plastered or concrete surfaces to give an even shade. [Through Rate] |
| 3 | [13.27]Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. [Through Rate] |
| 4 | [13.32]Providing and fixing bolts including nuts and washers complete. [Through Rate] |
| 5 | [23.22.1.10]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.10. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 125 to 160amp, 25 KA [Through Rate] |
| 6 | [23.22.5.1]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.1. Supply and erection of miniature circuit Breaker240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Single Pole [Through Rate] |
| 7 | [23.22.5.2]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.2. Supply and erection of miniature circuit Breaker240/415 V in the existing distribution board including making necessary connections:- 40 amp to 63 amp. Single Pole [Through Rate] |
| 8 | [23.26.2]SAFETY ITEMS 2. Supply and erection of High Tension Voltage caution notice plate of size 250*200 mm in three languages. [Through Rate] |
| 9 | [23.27.2]Supply and erection of Godrej Almirah typeM.S. pedestal made of 50 mm x 50 mm x 6 mm angle iron frame with 3.00 mm thick M.S. sheet covering including shutters with suitable hinges and locking arrangement with Godrej type handle including round bars . The top covering should have downward overhang of 75 mm on all sides of pedestal , having two sets of water proof ventilation holes of suitable size on the sides , at top and bottom , each set containing four Nos. holes to discharge the heat produced by the current . The shutters fixed with rubber gasket of superior quality and of suitable size to make it water proof .The pedestal duly painted both inside and outside with two coats of approved paint and primary coat and its legs are embeded upto the entire depth in 1:2:4 cement concrete block , projected 75 mm all around the pedestal and and 200 mm above the ground level including the cost of all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-in-charge of the work:- 2. M.S. pedestal of size 750 mm wide , 900 mm high , 300 mm deep and bottom totally open , duly embeded in cement concrete block of size 900 mm x 450 mm x 200 mm above ground level , having a base of size 1050 mm x 600 mm x 250 mm below ground level . 0 0 [Through Rate] |
| 10 | [24.1.1]EARTHING AND LIGHTENING ARRESTOR 1. Earthing with GL earth pipe 4.5 m long and 40 mm dia with masonry enclosures on the top etc. (but without charcoal or coke and salt) as required. [Through Rate] |
| 11 | [24.1.2]EARTHING AND LIGHTENING ARRESTOR 2. Extra for using salt and char coal/coke for pipe earth electrode as required. [Through Rate] |
| 12 | [24.1.8]EARTHING AND LIGHTENING ARRESTOR 8. Providing and fixing 25 mm x 3mm G.I. strip on surface or in recess for connections etc. as required with all labour and material. [Through Rate] |
| 13 | [24.2.1]LT CABLE 1. Supply & erection of LT phase separator on LT line complete in all respect up to entire satisfaction of the Engineer-in-charge of the work. [Through Rate] |
| 14 | [24.2.8.14]LT CABLE 8.14. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work.300 sqmm [Through Rate] |
| 15 | [24.2.8.9]LT CABLE 8.9. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 95 sqmm [Through Rate] |
| 16 | [24.5.2.3]MISCELLANEOUS ITEMS 2.3. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work.DWC/HDPE pipe 63/50 mm outer dia/inner dia [Through Rate] |
| 17 | [34.3.2]Printing New Letter and Figures of any ShadePrinting new letter and figures of any shade with synthetic enamel paint black or any other approved colour to give an even shade 2. English and Roman (Hyphens not to be paid) [Through Rate] |
| 18 | S/E of wooden cleats having 4 Nos. grooves for 300 Sqmm single core cable with Nut and bolts with all petty material up-to the entire satisfaction of E-I-C. |
| 19 | S/E of PVC unsheathedaluminum conductorcable single core 1100 volts grade in pipe ofsize 50 Sqmm excludingcost and erection of pipe. |
| 20 | Supply and erection of 11 KVAnti Climbing Device for 11/33 KV Line (with barbed wire 12 x 12 Gauge on existing PCC Pole complete in all respect upto the entire satisfaction of Engineer-in-Charge. |
| 21 | S/E of 11 mtr long PCC pole as per IS: 1678-1960 specifications,Dimensions 140mm x 200mm at top and 140mm x 400mm at bottom with working load of 400 Kg buried 2.20 m in ground or as per UHBVNL Specification. |
| 22 | S/E of V-shape cross arm made ofchannel iron 75mm x40mm x40mm x6mm (Total weight–10.1 Kg.) for11 KV over head line conductors complete with 50mm x 6mm M.S. flat iron clamps, bolts and nuts including drilling holes for insulator pins, bolts, nuts and washers etc. |
| 23 | S/E of top hamper suitable for 11 mtr. long PCC pole and 11KV system made out of MS flat size 50x6mm (U-shaped) having approx weight 2.5 kgas per approved design and drawing including primer and alum paint complete all respect. |
| 24 | S/E of 11 KV polymeric disc insulator 45 KNfor 11 KV over head lines withfittings, ball and socket type and complete with galvanized strain clamps, bolts, nuts, washers etc. as required. |
| 25 | S/E of 100mm2 ACSR conductor conforming to IS 398 ( Part-II) 1976/1996, IS 4826-1976 IS 1521-1972 and IS 1778-1980 with latest amendments and erection of the same with accessories including stringing and sagging of conductor as well as jointing and binding with insulator at supports in all respect. |
| 26 | S/E of cradle guards made of 8 S.W.G. G.I. wire for HT line complete in all respect. |
| 27 | S/E of 9 mtr long PCC pole as per IS:1678-1960 specifications. Dimensions 105mmx115 mm at top and 105 mm x315 mm at bottom with working load of 200 Kg, buried 1.80m in ground or as per UHBVNL Specification. |
| 28 | Supplying and erection of M.S.D-Strap iron clamps as per UHBVN design and specifications complete as required. |
| 29 | Supplying and erection of shackle insulator 75mm x 90mm as per UHBVN Specifications as required. |
| 30 | Supply and erection of stay set for L.T. Line complete in all respect with stay wire egg insulator comprisingM.S. rod of 20mm dia 8` long with stand 1000 Kg. load and threaded upto 250mm long with cross channel of size 450mm x 450mm made out of M.S. Channel 75x40mmx 6mmx6mm uptothe entire satisfaction to Engineer-in-Charge of the work. |
| 31 | S/E of 80mm² ACSR conductor conforming to IS 398 ( Part-II) 1976/1996, IS 4826-1976 IS 1521-1972 and IS 1778-1980 with latest amendments and erection of the same with accessories including stringing and sagging of conductor as well as jointing and binding with insulator at supports in all respect up to the entire satisfaction of Engineer-in-Charge. |
| 32 | Supply and erection of PVC insulated 30 Sqmm ACSR of approved make on existing PCC Poles complete in all respect upto the entire satisfaction of Engineer-in-charge. |
| 33 | Supply and erection of G.I. wire 8 SWG as per specification upto the entire satisfaction of Engineer-in-Charge |
| 34 | Supply and erection of guard for L.T. line with guard real complete in all respect up to the entire satisfaction of Engineer-in-Charge. |
| 35 | Supply, erection, testing and commissioningof L.T. Arial Bunched cable 120 Sqmm x 4Cplus95 Sqmm x1 core messenger wire P.V.C. sheathed on existing PCC pole, Conforming to IS standard and with latest amendments there to complete in all respect upto the entire satisfaction of Engineer-in-charge.Make: Polycab/Havell’s /Grandlay |
| 36 | S/E of underground cable, loose in existing pipe or trenches complete with necessary connections.Make: Grandlay, Polycab, Havel’s25 Sq. mm 4 Core Cable (Armd.) |
| 37 | S/E of PVC insulated and sheathed two or core cable 1100 Volt, each core having single solid aluminumconductor cables as per IS: 694, complete with necessary connections.Make: Grandlay, Polycab, Havel’s2.5 Sq mm x 3 Core Cable(Un-armd.) |
| 38 | Supply and erection of G.I. Pipe bracket 1.00 Mtr. long, made of 32 mm dia G.I. pipe (B-Class) Jindal Hisar Make suitable for street light fitting including 2 Nos. M.S. Clamps of M.S. Flat size 50x6mm, 06 Nos. Nut and Bolts of size 50x16mm and priming and painting complete in all respect upto the entire satisfaction of E-I-C. |
| 39 | S/E of Three Phase 11KV/ 0.433KV-250v, 200 KVA, Oil immersed, naturally cooled, Aluminium Wound Outdoor type Distribution Transformers with CSP (Completely self protected) features with external microprocessor based MCCB, strictly conforming to Nigam’s Technical specification No. CSC-V/R-I/DH/UH/P and D/2010-2011 read with amendment thereof and as per relevant ISS as amended from time to time and losses confirming to 4 star rating of BEE as per App. Make and specification of DHBVN/UHBVN including making of platform and installation of transformer up-to the entire satisfaction of E-I-C.Voltage Rated Frequency permitted at 75º Ci) Maximum loadlosses at 50% load at 75º C = 780 Wattii) Maximum losses at 100% load at 75º C = 2300 Wattiii) Warranty = 78/72 Months shall be one time.The above losses are maximum allowable and these would not be any positive tolerance. |
| 40 | S/E of fuse unit L.T. side of 200 KVA transformers complete with wooden board cleats, aluminum strips MS clamps and MS nut and bolts including all petty material required up to the entire satisfaction of Engineer-in-Charge |
| 41 | S/E of 11 KV G.O. with 9 Nos. post insulator switch suitable heavy duty with suitable copper male and female contents for 11 KV conforming to ISS: 1816/1972 and ISS : 2544/ 1963 with latest amendment thereof complete in all respect. |
| 42 | S/E of 11 KV lightening arrestor S/Stn type 9 KV 10 KA heavy duty type complete with MS nut and bolts including all petty material required upto the entire satisfaction of E-I-C. |
| 43 | S/E of 11 KV pin insulator polymeric type with 11 KV G.I. pin complete set on PCC pole of Make: Rashtriya/approved by state Electricity Nigam, conforming to IS: Part-II 1974 and IS: 2486 Part-I of 100mm GI pin to hold the insulator of 100mm GI pin to hold the insulator complete in all respect upto the entire satisfaction of E-I-C. |
| 44 | S/E of stay set for HT Line complete in all respect with stay wire Disc insulator comprisingM.S. rod of 20mm dia 8’ long with stand 1000 Kg. load and threaded upto 250mm long with cross channel of size 450mm x 450mm made out of M.S. Channel 75x40mmx6mmx6mm up-to the entire satisfaction to E-I-C |
| 45 | Supply and erection of P.G. clamp Al cast 2 bolt suitable for 100mm2 ACSR conductor (DOG) complete in all respect. |
| 46 | Supply and erection of G.I. Pipe bracket 1.00 Mtr. long, made of 25 mm dia G.I. pipe (B-Class) Jindal Hisar Make suitable for street light fitting including 2 Nos. M.S. Clamps of M.S. Flat size 50x6mm, 06 Nos. Nut and Bolts of size 50x16mm and priming and painting complete in all respect upto the entire satisfaction of Engineer-in-Charge. |
| 47 | Supply and erection of 63 Amps connection plate for incoming and outgoing cable in 9mtr. long octagonal pole fitted with connector fixed on Bakelite sheet complete with nut and bolts. |
| 48 | Only labour charges for ON/OFF operation of street light points of all type of LED Lights, Removal of Fault of circuits, Dismantlement and re-erection of LED fitting from S/L poles for LED lights under defect liability period .For 3rd year. |
| 49 | S/E of 25 Watt Pressure die cast aluminum housing LED Street Light fitting Luminaries with multiple LED lenses and heat resistant Poly carbonate cover glass IP 65of complete in all respect as per specifications having light efficacy of 120 Lumens/wattup to the entire satisfaction of Engineer -in-charge of the work. Make:-Bajaj/Philips/ LT/Panasonic/Anchor (With 3 years free replacement warranty at site including labour charges free of cost). |
| 50 | S/E of 70/72 Watt LED street light luminaire with multiple LED with highly efficient high power LED light with lens, pressure die cast aluminum housing, reflector and enclosed with toughened/ Polycarbonate glass, IP-66 level, having light efficacy 120 Lumens/watt and suitable for 40mm dia street light band, up to the entire satisfaction of Engineer -in-charge of the work. Detail specification sheet attached. Make: Bajaj/Philips/LT/Panasonic/Anchor |
| 51 | Supply and erection of PVC insulated 300 Sqmm single core (un-armoured) Aluminum conductor power cable with650/1100V confirming to ISS 1554(Part-I) of 1988 IS: 7098/Part-1/1988 with latest amendments with necessary connections and complete in all respect up-to the entire satisfaction of Engineer-in-Charge of the Work. Make: Grandlay/Polycab/Havell`s. (With GST). |
| 52 | Only Labour charges for ON/OFF operation of street light points of all type of LED lights, Removal of Fault of Circuits. Dismantlement and re-erection of LED fitting from S/L poles for replacement or repairing of LED lights under defect liability period. 2nd Year maintenance free of cost. (With GST) |