| 1 | M&L Comprehensive maintenance /repair and servicing of 13 passenger lift (03 Nos) installation fully comprehensive (i.e All in all) regular maintenance for round the clock, of the lift, including regular servicing, inspections, preventive maintenance by trained technicians and repair of the installation with bear the cost of repair / replacement of any of the worn out part without any additional charges atNC-I , NC-IIandDSCtowerNote-(i) One visit by state lift inspection areincluded in the quoted rates.The following items shall be replaced as & when required under AMC \"A\" type contract i.e (\"all in all\").For OMEGAas existing at site(ii)Any unserviceable electronics parts shall be replaced under AMC without any extra payment. (iii) Rate quoted is including of PRE AMC maint work. |
| 2 | All as per item No 1 above but, for 8 passenger lifts (03 Nos lifts) atNC-I , NC-IIandDSCtower |
| 3 | All as per item No 1 above but, forone 8 passenger lift at HQ SWAC |
| 4 | M&L Comprehensive maintenance /repair and servicing of 13 passenger lift (04 Nos) installation fully comprehensive (i.e All in all) regular maintenance for round the clock, of the lift, including regular servicing, inspections, preventive maintenance by trained technicians and repair of the installation with bear the cost of repair / replacement of any of the worn out part without any additional charges atW-4, S-1,MES type IV and Alpha Tower Note-(i) One visit by state lift inspection areincluded in the quoted rates.The following items shall be replaced as & when required under AMC Platinum type contract i.e (\"all in all\").For Thyssen Kruppas existing at site(ii)Any unserviceable electronics parts shall be replaced under AMC without any extra payment. (iii) Rate quoted is including of PRE AMC maint work. |
| 5 | All as per item No 4 above but, for 8 passenger lifts (04 Nos) atW-4, S-1, MES type IV and Alpha Tower |
| 6 | M&L Comprehensive maintenance /repair and servicing of 13 passenger lift (01 No) installation fully comprehensive (i.e All in all) regular maintenance for round the clock, of the lift, including regular servicing, inspections, preventive maintenance by trained technicians and repair of the installation with bear the cost of repair / replacement of any of the worn out part without any additional charges atW-8, TowerNote-(i) One visit by state lift inspection areincluded in the quoted rates.The following items shall be replaced as & when required under AMC Platinum type contract i.e (\"all in all\").For Thyssen Kruppas existing at site(ii)Any unserviceable electronics parts shall be replaced under AMC without any extra payment. (iii) Rate quoted is including of PRE AMC maint work. |
| 7 | All as per item No 6 above but, for 8 passenger lifts (01 No ) atW-8, Tower |
| 8 | M&L Comprehensive maintenance /repair and servicing of 13 passenger lift (01 No) installation fully comprehensive (i.e All in all) regular maintenance for round the clock, of the lift, including regular servicing, inspections, preventive maintenance by trained technicians and repair of the installation with bear the cost of repair / replacement of any of the worn out part without any additional charges atC-10, TowerNote-(i) One visit by state lift inspection areincluded in the quoted rates.The following items shall be replaced as & when required under AMC Platinum type contract i.e (\"all in all\").For Thyssen Kruppas existing at site(ii)Any unserviceable electronics parts shall be replaced under AMC without any extra payment. (iii) Rate quoted is including of PRE AMC maint work. |
| 9 | All as per item No 8 above but, for 8 passenger lifts (01 No) atC-10 Tower |
| 10 | M&L Comprehensive maintenance /repair and servicing of 13 passenger lift (01 No) installation fully comprehensive (i.e All in all) regular maintenance for round the clock, of the lift, including regular servicing, inspections, preventive maintenance by trained technicians and repair of the installation with bear the cost of repair / replacement of any of the worn out part without any additional charges at B TowerNote-(i) One visit by state lift inspection areincluded in the quoted rates.The following items shall be replaced as & when required under AMC Platinum type contract i.e (\"all in all\").For Thyssen Kruppas existing at site(ii)Any unserviceable electronics parts shall be replaced under AMC without any extra payment. (iii) Rate quoted is including of PRE AMC maint work. |
| 11 | All as per item No 10 above but, for 8 passenger lifts (01 No ) atB Tower |
| 12 | M&L Comprehensive maintenance /repair and servicing of 13 passenger lift (01 No) installation fully comprehensive (i.e All in all) regular maintenance for round the clock, of the lift, including regular servicing, inspections, preventive maintenance by trained technicians and repair of the installation with bear the cost of repair / replacement of any of the worn out part without any additional charges atW-7 TowerNote-(i) One visit by state lift inspection areincluded in the quoted rates.The following items shall be replaced as & when required under AMC Platinum type contract i.e (\"all in all\").For Thyssen Kruppas existing at site(ii)Any unserviceable electronics parts shall be replaced under AMC without any extra payment. (iii) Rate quoted is including of PRE AMC maint work. |
| 13 | All as per item No 12 above but, for 8 passenger lifts (01 No) atW-7 Tower |
| 14 | M&L Comprehensive maintenance /repair and servicing of 13 passenger lift (01 No) installation fully comprehensive (i.e All in all) regular maintenance for round the clock, of the lift, including regular servicing, inspections, preventive maintenance by trained technicians and repair of the installation with bear the cost of repair / replacement of any of the worn out part without any additional charges atW-1 TowerNote-(i) One visit by state lift inspection areincluded in the quoted rates.The following items shall be replaced as & when required under AMC Platinum type contract i.e (\"all in all\").For Thyssen Kruppas existing at site(ii)Any unserviceable electronics parts shall be replaced under AMC without any extra payment. (iii) Rate quoted is including of PRE AMC maint work. |
| 15 | All as per item No 14 above but, for 8 passenger lifts (01 No) atW-1 Tower |
| 16 | M&L Comprehensive maintenance /repair and servicing of 13 passenger lift (01 No) installation fully comprehensive (i.e All in all) regular maintenance for round the clock, of the lift, including regular servicing, inspections, preventive maintenance by trained technicians and repair of the installation with bear the cost of repair / replacement of any of the worn out part without any additional charges atC-6 TowerNote-(i) One visit by state lift inspection areincluded in the quoted rates.The following items shall be replaced as & when required under AMC Platinum type contract i.e (\"all in all\").For Thyssen Kruppas existing at site(ii)Any unserviceable electronics parts shall be replaced under AMC without any extra payment. (iii) Rate quoted is including of PRE AMC maint work. |
| 17 | All as per item No 16 above but, for 8 passenger lifts (01 No) atC-6 Tower |
| 18 | M&L Comprehensive maintenance /repair and servicing of 13 passenger lift (02 Nos) installation fully comprehensive (i.e All in all) regular maintenance for round the clock, of the lift, including regular servicing, inspections, preventive maintenance by trained technicians and repair of the installation with bear the cost of repair / replacement of any of the worn out part without any additional charges atC & C-8 TowerNote-(i) One visit by state lift inspection areincluded in the quoted rates.The following items shall be replaced as & when required under AMC Platinum type contract i.e (\"all in all\").For Thyssen Kruppas existing at site(ii)Any unserviceable electronics parts shall be replaced under AMC without any extra payment. (iii) Rate quoted is including of PRE AMC maint work. |
| 19 | All as per item No 18 above but, for 8 passenger lifts (02 Nos) atC & C-8 Tower |
| 20 | Note - for item No 1& 19 : (i) Any required electrical/ mechanical parts of above mentioned lifs or any other parts also are to be repair/replaced as & when it became unserviceable as per term & condition of omega/ Thyssen Kruppunder the AMC \"A\" type contract,any cost of material & labour charge will not be paid extra .(ii) Any other material become un serviceable which is not in the scope of AMC \"A\" type contract is also to be repaired/replaced timely to run the lift smoothly without any extra payments .(iii) The terms & conditions of this AMC as applicable as given in Annexure I & II by OMEGA and Thyssen Krupp (iv) The comprehensive maintenance inclusive of inspection/testing/preventive maintenance replacement of unserviceableparts/material including labour, transportation. (v)The complaints shall be attended forthwith as the complaints/failure from the time of receipt of same (vi) Contractor shall rectify the defects within 24 hrs after receipt of complaints , otherwise the complaints will be rectified by the other agency and the expenditure incurred will be recovered at Rs 2000/per day till proper functioning of lift.(vii) The schedule A consists of comprehensive maintenance lifts(viii) The load testing of lifts ie 8 passenger and 13 passenger shall be carried out as per standard norms of OMEGA/Thysen and hand over certificate to the department. |
| 21 | Note For particular specification :(a) The work under authorised dealer comprehensive maintenance of lifts all as specified in Sch A ,Special Condition, Particular Specification, MES SSR, latest relevant IS code and as directed by GE/ Engr-in-charge. (b) The tender shall have to submit the copy of MOU with authorised dealer to carry out the comprehensive maintenance in a separate envelop attached with the envelope containing quoted tender documents and failing which the tender will be treated as non- bonafied and will not be considered for opening of the same. (c) Lift machine shall be well experienced in lift/elevators repairs and maintenance. (d) The contractor shall ensure proper functioning of safety devices.(e) The contractor shall provide lift maintenanceChart for Daily, Weely and Monthly(f) All safety precautiobns shall be dispalyed as per lift rules |
| 22 | S&FFan blower of lift cabin, with existing make suitable for lift of Thyssen krupp or Omega as per site requirement as in repairs complete all as specified and as directed by Engr- in- Charge |
| 23 | S&F LED light of cap 10watt of lift cabin, with existing make suitable for lift of Thyssen krupp or Omega as per site requirement as in repairs complete all as specified and as directed by Engr- in- Charge |
| 24 | S&F LED light SMT 0701 or suitable model of lift cabin ofThyssen krupp or Omega as per site requirement as in repairs complete all as specified and as directed by Engr- in- Charge |
| 25 | S&F UPS1 KVA of liftwith existing make suitable for lift of Thyssen krupp or Omega as per site requirement as in repairs complete all as specified and as directed by Engr- in- Charge |
| 26 | S&FOnline 2.2 KVA 920 Watt smartUPS line interactive with internal batteries of liftwith existing make suitable for lift of Thyssen krupp or Omega as per site requirement as in repairs complete all as specified and as directed by Engr- in- Charge |
| 27 | S&FOnline 3 KVA smartUPS line interactive with internal batteries of liftwith existing make suitable for lift of Thyssen krupp or Omega as per site requirement as in repairs complete all as specified and as directed by Engr- in- Charge |
| 28 | S&F Batteries of capacity 12 Volt and 7 AH for UPS device of liftwith existing make suitable for lift of Thyssen krupp or Omega as in repairs complete all as specified and as directed by Engr- in- Charge |
| 29 | S&F Batteries of capacity 12 Volt and 18 AH for UPS device of liftwith existing make suitable for lift of Thyssen krupp or Omega as in repairs complete all as specified and as directed by Engr- in- Charge |
| 30 | S&F Display of liftwith existing make suitable for lift of Thyssen krupp or Omega as in repairs complete all as specified and as directed by Engr- in- Charge |
| 31 | S&F MCB DP \"C\" type 240 V,50 Hz,10 KA of capacity 6-32 Amp as suitable for existinglift panelcomplete as in repairs all as specified and as directed byEngr- in- Charge |
| 32 | S&FMCB TPN\"C\" type420 V,50 Hz,10 KA of capacity 40Amp as suitable for existing lift panel complete as in repairsall as specified and as directed byEngr- in- Charge |
| 33 | S&FMCB TPN\"C\" type420 V,50 Hz,10 KA of capacity 63Amp as suitable for existing lift panel complete as in repairsall as specified and as directed byEngr- in- Charge |
| 34 | S&F RCCB \"A\" type DP 240 V,50 Hz,10 KA of capacity 25 Amp and 30mA as suitable for existinglift panelcomplete as in repairs all as specified and as directed byEngr- in- Charge |
| 35 | S&FRCCB \"A\" type DP 240 V,50 Hz,10 KA of capacity 40 Amp and 300mA as suitable for existinglift panelcomplete as in repairs all as specified and as directed byEngr- in- Charge |
| 36 | S&F RCCB \"A\" type FP 420 V,50 Hz,10 KA of capacity 25 Amp and 300mA as suitable for existing lift panelcomplete as in repairs all as specified and as directed byEngr- in- Charge |
| 37 | M & L Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried in ground (earth pit not less than 2.25 Mtr deep below normal ground level with top edge of the plate not less than 1.5 Mtrs below normal ground level, connecting to galvanized iron earth strip 32x6 mm as earthing leadby means of bolt ,nuts, check nuts and washer of galvanized iron or steel besides welding of all joints as shown in drawing and including excavation and earthworkand earth lead protection by provision of GI medium grade pipe 40 mm bore including provision of concrete pit in PCC (1:2:4) type B1 using 20mm graded stone aggregate with 40mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4gs/Sqm) and frame of angle iron 25mm x 25mm x 6mm with lugs 02 Nos and with 6 mm dia MS bar handle made to shape, GI light grade 20mm bore pipe for watering perforated at the bottom 1.75 meter long placed on top edge of earth plate common salt and charcoal filling test point made out of 40mm x 8 mm FI with fixing arrangements, funnel, wire mesh and earth work in hard dense soil, returning filling in and removal of surplus soil to a distance not exceeding 50 Mtrs all as per electrical Plate No.3 of SSR Part I and connecting to earth test point all as specified or indicated including testing on completionNote:(i) Item includes the cost of 7.5 metre length ofGI pipe for protection with earth strip (ii) Earth resistance of earth pit should be less than 0.5 Ohms. On testing after completion if the desired earth resistance in not obtained the earthing will be redone at no extra cost |
| 38 | S&F Earth continuity conductor or main earth lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to pole or any other indicated situation for loop earthingetc as required with 32x6mm GI earth srip complete as in repairs all as specified |