| 1 | Drilling of 150 mm dia T/W bore suitable for 110mm dia pipe/200mm dia T/W bore suitable for 140 mm dia pipe all complete with labour T/P as per direction of engineer incharge |
| 2 | Supply and lowering of 140mm dia 10kg/cm2 with plastic net cover slots of pvc pipe by UPIN(phenolex or apb by E/I) all complete |
| 3 | Supply and pouring of pee gravels suitable for T/W bore all complete as per direction of engineer incharge |
| 4 | S/F of 110mm PVC pipe adopter suitable for item no. 2 |
| 5 | Supply of 1HP submersible pump set with starter UPIN 65m head ( Pluga/Crompton Greeves/KSB) |
| 6 | Supply and fitting of 4sqmm 3 core copper wired cable (ISI mark) complete in all respect |
| 7 | Supply and lowering of 40 mm dia ribbed screen Ashirvad PVC pipe (ISI marked)/ 32 mm dia G.I. Pipe by UPIN and fixed with boat site threaded SS nipple all complete. |
| 8 | Transportation of all material T&P etc to the site of work, loading, unloading and proper stacking at the site including return cartage of unused material with the diging the pit of boring work including supply all labour T&P with with arrangement of water required etc all complete. |
| 9 | Installation of 1.00HP submersible motor pump with 32mm G.I. Lowering, submersible cable 4sqmm & installation of starter including supply of labpur, T&P etc complete in all respect |
| 10 | devlopment of bore hole till the discharges of water become free from sand and turbidity by compression and disinfection of bore including supply of all labour T&P |
| 11 | Chemical & bacteriological testing of water sample |
| 12 | Supply and burying of 40mm dia x 4.5 metres long G.I. Pipe vertically for earthing having 12mm dia. Holes spaced 75mm apart drilled up to 2 metre from the bottom complete with earthing lead of No. 6 to 8SWG GI wire in G.I. Pipe up to appron (and from appron to switch board the cost of G.I. wire and pipe will be extra) upto switch board, 30cm square C.I. box with hinged cover masonary enclosure, funnel at top, alternate layers of charcoal/coke and salt at least 150mm thick alround etc. as per directions of Engineer-in-charge complete in all respects as per drawing. |
| 13 | Supply and fixing of one number 8 to 6 SWG G.I.Wire in 15 mm dia G.I. pipe for ear thing ,laid in ground or in wall duly concealed including the cost of cement ,sand .lab our , T&P other material required for proper completion of the work as directed at site. |
| 14 | S/F of 32mm dia G. I. Pipe complete with G. I. Fittings,clamps including all materials, Labour etc complete in all respects. |
| 15 | S/F of CP brass stop cock 15mm of approved make complete in all respects. |
| 16 | S/F of 6 Amp to 32 Amp SPMCB (10 KA) C Curve Cat B |
| 17 | S/F of 6 Amp to 32 Amp. DPMCB (10 KA) C curve Cat B |
| 18 | S/F surface/flush mounting 4 way SPN distribution board with additional metal door without MCB complete in all respect and as directed at site. Cat B |
| 19 | S/F of CP brass bib cock 15mm of approved make complete in all respects. |
| 20 | S/F of gun metal non return valve 32mm of approved make complete in all respects. |
| 21 | S/F of 32 Amp 415 Volt TPN Metal Clad Rewirable type switch fuse unit on angle iron bracketcomplete in all respects. |
| 22 | Supply and laying of aluminium conductor PVC insulated armoured served, sheathed cable 1100 volts grade at a depth of 750 mm. below ground level over a cushion of 75 mm. thick stand alround and protected with burnt bricks on sides and on top. on surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Inchange, complete in all respect. The armoring of the cable shall be properly connected with the earthy conductor by clamps etc. 6 sq. mm. 2 core cable.20a.1.1 |
| 23 | Supply & fixing steel tubular pole 9.50 Metre long designated 410 SP-36 in 1:3:6 cement concrete foundation including excavation back filling etc. complete in all respect. |
| 24 | Supply & fixing of 100 mm x 110 mm shackle insulator /100 mm x 80 mm pin insulator including G.I. Bolts / spindle nuts etc. complete in all respect. |
| 25 | Supply & erection of \"D\" clamps of 50 mm x 6mm flat iron on steel tubular poles / steel rail poles with bolts, nuts etc. complete in all respects including painting with aluminium paint |
| 26 | Supply & erection of overhead line with ACSR conductor on poles / service bracket including binding etc. complete in all respects. |
| 27 | Tighting of ACSR conductor |
| 28 | Supply & erection of hexagonal / cradle type gaused of G.I. wire no. 8 to 4 SWG including binding etc. complete in all respect |
| 29 | Supply and erection of stay set at 3.5 Metres away from the pole complete with galvanised 19 mm dia × 1.80 Metre long stay rod, 30 cm × 30 × 6.3 mm anchor plat, thimble stay clamps, stay insulator, 19 mm 600 mm double screw tightener, 7/3.5 mm G.I. stay wire etc. in 1:3:6 cement concrete in all respects. |
| 30 | Painting of the electric pole with 2 coats of aluminum paint over red oxide primer complete in all respects. |
| 31 | Supply and fixing of LED Street light Fitting with Mandatory driver set having die cast aluminium body with toughend hlass UV stabilized PC cover and lenses Suitable for110 to 130 watt confirming to IP66 and 1K07 and aboveProtection Having company LOGO Engraved complete in all respect.including labour 13200-15600 system lumens high power LED with lenses,>120 Lm /W,PF>0.95,THD<10% at full load CRI>70,Potted driver set (not circultory),Phase to phase protection at 440V&>300V auto cut and restart feature,4KV Internal Surge Protection with five year Warrantee.Cat AAA. |
| 32 | Supply and erection of factory fabricated and wired metal clad dust and vermin proof floor mounting panel TPN switch board complete with the following HRC type heavy duty TPN fuse switches with fuses and instrument chamber etc. complete in all respects. The instrument chamber shall be separate and shall comprise of flush type ammeter, voltmerer, selector switches for ammeter and voltmeter, instrument fuses, current transormer etc. The board shall have suitable capacity electroytic alumininum busbars as per IS8623 istulate with heat shrink sleeving and mountend on non hygroscopic supports such as CMC/DMC support with deteachable side covers and shall be suitable for extension on the sides. The switches shall be complete with suitable cable end boxes, reverse entery boxes in case of pedestaal type, cable sockets, compression glands and indicating lamp on incoming etc. The job includes the grounting of the board as per direction of Engineer-in-Charge. All coutgoing switches of 100 Amp. and above will be provided with ampere metre current transformers and selector switches and instrument fuses etc. The switches board shall be fabricated with CRCA sheet with a minimum thickness of 1.6 mm/2 mm. Cubicle type switch board shall be of cat A B & B-II and pedestal type for Cat-B a only.Incoming -200 Amp. TPN-1 Nos.Outgoing-100 Amp. TPN-1 No & 63 Amp. TPN-3 Nos. |
| 33 | Supply and laying of aluminium conductor PVC insulated armoured served, sheathed cable 1100 volts grade at a depth of 750 mm. below ground level over a cushion of 75 mm. thick stand alround and protected with burnt bricks on sides and on top. on surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Inchange, complete in all respect. The armoring of the cable shall be properly connected with the earthy conductor by clamps etc.95 sq. mm.3.5 core cable.20a.1.14 |
| 34 | Supply and laying of aluminium conductor PVC insulated armoured served, sheathed cable 1100 volts grade at a depth of 750 mm. below ground level over a cushion of 75 mm. thick stand alround and protected with burnt bricks on sides and on top. on surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Inchange, complete in all respect. The armoring of the cable shall be properly connected with the earthy conductor by clamps etc. 6 sq. mm. 2 core cable.20a.1.1 |
| 35 | S&F of 63 A. 415 Vmetal clad TPN Rewireable type Switch fuse unit on angle ironBracket complete in all respect 316 |
| 36 | S/F of 11 KV TPMO with Polymer Insulator. UPPCL X50 515 (92) UPPCL |
| 37 | S/F 3 phase D.O. Fuse Set 11 KV. UPPCL X50 515 (93)UPPCL |
| 38 | Wiring point for light in 1.5 sq mm FRLSH PVC insulated multi strandsingle core copper conductor cable (drawn through existing concealed steel conduit) 5 Amp. modular type switch and ceiling rose / angle/ batten holder on 3 mm thick Phenolic laminated sheet mounted over existing M.S switch board box/ junction box with supply of all material, labour & T&P etc required for proper completion of the work as directed at site by the Engineer in charge. with modular switch and /ceiling rose /angle holder /batten holder complete in all respects as directed including matching colour wash. |
| 39 | Wiring point for ceiling fan in 1.5 sq mm FRLSH PVC insulated multi strandsingle core copper conductor cable (drawn through existing concealed steel conduit) 5 Amp. modular type switch and ceiling rose on 3 mm thick Phenolic laminated sheet mounted over existing M.S switch board box/ junction box with supply of all material, labour & T&P etc required for proper completion of the work as directed at site by the Engineer in charge. with modular switch and /ceiling rose /angle holder /batten holder complete in all respects as directed including matching colour wash. |
| 40 | Wiring point for plug in 1.5 sq mm FRLSH PVC insulated multi strandsingle core copper conductor cable (drawn through existing concealed steel conduit) 5 Amp. modular type switch and3 pin socket on 3 mm thick Phenolic laminated sheet mounted over existing M.S switch board box/ junction box with supply of all material, labour & T&P etc required for proper completion of the work as directed at site by the Engineer in charge. with modular switch and /ceiling rose /angle holder /batten holder complete in all respects as directed including matching colour wash. |
| 41 | S/f of LED Tube light with metal heavy duty box type batten light fitting 1x22 watt suitable for up to 1x22 watt LED Polycarbonate tube light complete including tube suitable for both surface &suspended complete in all respect.2620 system lumens,>120 Lm/W, PF>0.95,THD<10%,CRI>80,Sheet thickness 0.8 mm, Tube with Aluminium sink,>300 V over Voltage Protection 2.5 KV Internal Surgr Protection, with 3 Year warrantee.CAT- AA. |
| 42 | Supply /fixing of power plug with 20A/250 V flush type modular switch and 5 pin 20A/250 V flush type socket in suitable M.S. box of 175 mm x 100 mm x 50 mm size with bakelite sheet cover 3 mm thick fixed with brass machine screw and cup washer |
| 43 | Supplyandwiringof submain with two number 2.5 sq. mm FRPVC insulated 1100 V multi strand singlecore copperconductor cable in 20 mm dia. heavy gauge rigid steel conduit concealed in wall complete with 14 SWG copper earth continuity wire. directed including matching colour wash. |
| 44 | S&F of 63 Amp.DP MCB (10 KA) C CurveCat A |
| 45 | S/F of surface/flush mounting 8 ways SPN distribution board without additional metal door without MCB complete in all respect and as directed at site Cat A |
| 46 | S/F of electronic fan regulator 120-280 V ISI Marked on the existing switch board including making connection , required materials, labour T/P for proper completionof work to the satisfaction of engineer in chargeof work. |
| 47 | Supply of Ceiling Fan with fan motor of AC Permanent insulation capacitor rating confirming BEE 5 star rating and IS:374/79 and also comply with IS: 1709/1984 with latest amendment. The rated voltage 220/240 volts, 50 Hz, 1 ph AC the fan assemble should consists of down rod blades, shackle canopies etc and with double ball bearing system (ii) BEE 4 star rated- 1200 mm sweep |
| 48 | S/L of aluminim conductor PVC insulated armored, served, sheathed cable 1100 Volts grade at a depth of 750 mm. below ground level over a cushion of 75 mm thick sand alround and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by Engineer-In-Charge, complete in all respects The armoring of the cable shall be properly connected with the earth conductor by clamps etc. (i) 16sqmm 2 core |
| 49 | S/F of following 4 Module size (125 mm x 75mm ) module GI box alongwith Modular base and cover Plate for Modular switches in resess etc. |
| 50 | S/F of following 6 Module size (200 mm x 75mm ) module GI box alongwith Modular base and cover Plate for Modular switches in resess etc. |
| 51 | S/F of following 8 Module size (125mm x 125 mm ) module GI box alongwith Modular base and cover Plate for Modular switches in resess etc. |
| 52 | S/F of following 12 Module size (200 mm x 150 mm ) module GI box alongwith Modular base and cover Plate for Modular switches in resess etc. |
| 53 | Add for Invertor Wiring Point for light/Fan/Plug with 1.5 mm Cu Wire |