| 1 | Notes : (i) The work consists of 01 job as under:- JOB (A) : MAINT GRANT 2024-2025(ii) Please refer schedule \"A\" notesbefore quoting the tender.(iii) Amount of Schedule of Credit shall be deducted off line by the department.ITEMS FOR JOB \"A\" |
| 2 | M & L for repair/maintenece and servicing ofSplit type Air conditioner/Window type unit of any capacity outer and inner unit both of any make including cleaning the dust frombody with blower, cleaning of condenser and cooling coil, checking all connections including functioning of metal clad socket/DP switch, function of relay, capacitors, overload protector, thermostat, fan motor,fan/blower drum, main control board PCB, electronic contol box, etc, oiling/greasing of fan motor, checking serviceability, cleaning of the air filter woolen felt & refixing ensuring for air tighting complete, repair and replacement of warn out/unserviceable spares including taking down and refixing, transportation to and from workshop if required and refixing it in its original place or at new loactionafter fully servicing including testing & commissioningcomplete all as specified and directed by Engineer-in-Charge.(Note: Spares parts replaced shall be measured & paid under saperate item) |
| 3 | All as per Item No 1.01 above but for Water cooler/Deep freezer/Refrigerator of any type and any capacity complete all as specified and directed |
| 4 | Supply only starting capacitor 80-100mfd for AC, water cooler, Refrigerator, deep freezer etc all as specified and directed. |
| 5 | Supply onlyrunning capacitor 10MFD |
| 6 | Supply onlyrunning capacitor 25MFD |
| 7 | Supply onlyrunning capacitor 36MFD |
| 8 | Supply Only running capacitor 50MFD |
| 9 | Supply Only running capacitor 60MFD |
| 10 | Supply onlyblower motor capacitor 4MFD |
| 11 | Supply onlyblower motor capacitor 6MFD |
| 12 | Supply onlyblower motor capacitor 10MFD |
| 13 | Supply only starting relay suitable for water cooler,AC, and refigerator, deep freezer for any make and model opreated on single phase 230 volts all as specified and directed. |
| 14 | Supply Only for over load relay comprising of over load protection suitable for air contioner, water cooler, deep freezer and refrigerator opreated in shingle phase 230 volt all as specified and directed. |
| 15 | Supply Only themostat switch suitable for Air conditioner,water cooler, deep freezer and refigerator operated on single phase 230 volts supply all as specified and directed. |
| 16 | Supply only drier filter for AC ,water cooler and refrigerator. |
| 17 | Supply only air filter suitable for window AC/Indoor unit of Split AC upto 2TR capacity as per existing type and size |
| 18 | Supply only magnetic contactor as in outer unit of Split type air conditioner as per existing type complete all as specified and directed. |
| 19 | Supply Only capillary tubes for the following :- |
| 20 | Air Conditioner1.5 ton /2 ton and Water cooler 40to 150 ltr |
| 21 | Refrigerator& Deep freezer upto 400 ltr |
| 22 | Supply only indoor fan motor of split type AC of any capacity |
| 23 | Supply Onlycondenser fan motor 1300rpm, 1/6Hp, 1/8Hp, 1/10Hpfor Split type Air Conditioner outdoor unit of 1.0Ton/1.5Ton/2.0Ton as per existing make and capacity all as specified and direted by Engineer In Charge |
| 24 | Supply Onlycondenser fan motor double shaft1/6Hp, 1/8Hp, 1/10HpforWindow type ACof 1.0Ton/1.5Ton/2.0Ton as per existing make and capacity all as specified and direted by Engineer In Charge |
| 25 | Supply Onlycondenser fan motor1/36Hp forWater Coolerof 40-80Ltr and deep freezer upto 400Ltr as per existing make and capacity all as specified and direted by Engineer In Charge |
| 26 | Supply Onlycondenser fan motor1/6Hp, 1/8Hp, 1/10Hp forWater Coolerof 120-150Ltr as per existing make and capacity all as specified and direted by Engineer In Charge |
| 27 | Supply only blower/condenser fan blades as per existing make & type for Air conditioner/Water cooler/deep freezer all as specified |
| 28 | S & F Copper tubing including brazing, flaring & testing of size 1/2\" and 5/8\" in required length with nitrile rubber insulation for suction and discharge line of split air conditioner complete all as specified and as directed |
| 29 | Supply and installed Nitrile rubber insulation in replacement for existing damaged/warn out/unserviceableinsulation for air conditioner piping. |
| 30 | Supply, install, test & commissioning thermetically sealed New compressor for Split Type AC of capacity 1.5TR duly charged withfresh freon gasetc complete all asspecified/directed by Engineer-in-Charge including taking down old u/s compressor.Make- Voltas/Shriram/LG/Godrej/Kirloskar/Carrier/Hitachi or as per existing make at site. |
| 31 | All as per Item No 1.29 but for Split Type AC of capacity 2.0 TR |
| 32 | All as per Item No 1.29but forWindow Type AC of capacity 1.5TR |
| 33 | All as per Item No 1.29 but for Water Cooler of capacity 40 to 80Ltr |
| 34 | All as per Item No 1.29but for Water Cooler of capacity 120 to 150Ltr |
| 35 | All as per Item No 1.29but for Refrigerator 165 to 210Ltr Capacity |
| 36 | All as per Item No 1.29but for Refrigerator 286 to 310Ltr Capacity |
| 37 | All as per Item No 1.29 but for Deep freezer up 298 to 310 ltr capacity |
| 38 | M & L for taking down old u/s condenser coil (Heat exchanger) and S&F new copper condenser coil as per existing make and model for Split AC 1.5TR with necessary welding/brazing, leak testing & gas filling all as directed and as specified by Engineer In Charge |
| 39 | All as per Item No 1.37but for Split Type AC of capacity 2.0 TR |
| 40 | All as per Item No 1.37 but forWindow Type AC of capacity 1.5TR |
| 41 | All as per Item No 1.37 but for Water Cooler of capacity 40 to 80Ltr |
| 42 | All as per Item No 1.37 but for Water Cooler of capacity 120 to 150Ltr |
| 43 | All as per Item No 1.37 but for Refrigerator 165 to 210Ltr Capacity |
| 44 | All as per Item No 1.37 but for Refrigerator 286 to 310Ltr Capacity |
| 45 | All as per Item No 1.37 but for Deep freezer up 298 to 310 ltr capacity |
| 46 | M & L for Detecting the gas leakage, rectifying the defects including repair to condenser coil/evaporator coil by means of welding, soldring etc, vacumizing and charging, topping up fresh freon Gas and commissioning and testing for the 1.5Ton/2.0ton split type/window type AC all as specified and directed by Engineer In Charge |
| 47 | All as per item No 1.45 herein above but of water cooler, refrigerator & deep freezer of any type and any capacity |
| 48 | Supply and replace remote control unit of Split type AC1.5 ton/2.Ton including making frequency arrangement of new remote with existing system all as specified and directed by Engineer In Charge |
| 49 | Supply only Electronic PCB unit for main control panel of Split type/Window Type AC of any capacity |
| 50 | Supply OnlyPVC flexible pipe 25 mm dia as in drain pipe suitablefor water cooler outlet |
| 51 | M&L for dismantling of existing unserviceable voltage stabilizer for repairs including replacement of relays , electronic voltage sensor circuits and meter, micro switch , indication light RC fitters and other connected items for making funcional as per the entire satisfaction of Engr-in-charge and rewinding of unserviceable transformer with super enameled copper wire of appropriate size , varnishing assembling and testing complete for following capacities:- |
| 52 | Upto 1 & 2 KVA |
| 53 | Upto 3 to 5 KVA |
| 54 | Disconnecting electrical / mechanically and lowering to the ground for repairng / over hauling the desert cooler including replacement of canvas grass / wood wool pads and spary painting to body with one coats of anti corrisive red oxide primer for any make of desert cooler to make it fully funcitonal including replacement of unservicable/defective spare parts, transportation to and from, re-installation and testing on completion to the entire satisfaction of Enineer -in - chargeNote : 1. Replacement of canvas grass / wood wool pads/pvc flexible water pipeincluding PVC T/Y/L branch connections and spary painting is included in quoted rates2. Other Spares replaced will be measured and paid under saperate Item here in after |
| 55 | Supply only water lifting pump 1/70 HP capacity , operated on single phase 230 volts with all accessories and testing complete to the entire satisfaction of Engr -in-charge. |
| 56 | Supply only fan motor of desert cooler of any capacity includingsupporting legs , brackets, nuts and bolts etc. |
| 57 | Supply only fan blade with bush for desert cooler motor |
| 58 | Supply only selector switch/rotary knobfour way suitable for desert cooler as per existing size and make |
| 59 | Supply only electronic control circuit board (PCB) as per existing type for desert cooler. |
| 60 | Supply only swing motor for air cooler |
| 61 | M & L for fabrication ofbase tray/top cover suitable for desert cooler upto capacity 5000Cum/Hr to match with existing size of tray/body of desert coolerwith 1mm Galvansised steel Sheet with necessary cutting, bending, welding and powder coated paint over one coat of red oxide all as specified and as directed |
| 62 | M & L for repair/replacement tostainless steelwaste water tray including welding, polishing, riveting, provision of fixing screws and refixing. |
| 63 | M & Lforreplacement damage cooling coil for refrigerator of capacity 210/300 ltrs |
| 64 | Supply Only door switch for refrigerator of any type and any capacity |
| 65 | Supply only pigmy lamp (indoor lamp) as per existing type for refrigerator |
| 66 | Supply only freezer door as per existing make and typr for refrigerator |
| 67 | Supply only timer switch assembly for refrigerator as per existing for capacity 210 to 300Ltrs |
| 68 | S & F Metal Plug Tops for 2Pin and earth socket AC Box of capacity 240V, 20A all as specified and directed |
| 69 | S & F Plug Top, SP, 240V, 3pin,6A |
| 70 | S & F Plug Top, SP 240V, 3pin, 15A |
| 71 | S & F PVC insulated flexible copper cables 2.5sqmm 3 core for electric supply |
| 72 | S & F uPVC MAXItrunking profile of size 150x50mm fixing on wall for covering AC piping, cable, drain pipe etc all as specified and directed |
| 73 | S & F Sheet metal enclosure for Single pole and neutral withtwo pin and earth plug and socket complete with one single pole MCB 20Amps. |
| 74 | S & F Switch socket combination 2 in 1, 3 pin, 6 and 16 Amp flushtype universal |
| 75 | Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule for 15mm bore dia. |
| 76 | S & F in repair Push tap Self closing taps of size 15mm of cast iron or malleable cast iron, galvanised, screwed for iron pipe or for water cooler |
| 77 | Supply and fix PVC connecting pipe with brass nuts and washers at both ends of length not exceeding 60 Cms for connection of water coolers with taking down old pipe |
| 78 | M & L for Framed work such as grills, gratings, etc. for water tanks, water cooler stand, AC Unit supports, and similar work conforming to Fe.290.Gde-E-165 with two coat of synthetic enamaled paint over coat of red oxide primer all as directed and specified by Engineer In Charge |
| 79 | M & L Cutting openings, through brick walls for door, window and other openings or enlarging existing openings built in cement morter etc. for installation of window AC and Forming jambs, etc. in cement morter 1:4, to openings (to foregoing item),including cutting, toothing and properly bonding into old work, also facing, jointing and pointing to match existing work, complete making good to disturbed surfaces all as specified and as directed |
| 80 | Supplying and laying of CPVC pipes of SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floorscomplete all as specified of following Sizes: |
| 81 | Outer dia 16mm |
| 82 | Outer dia 20mm |
| 83 | S & F Rigid non-metallic PVC conduit 25mm diaexclusive of boxes (junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts,saddles, pipe hooks etc. for drain out AC condensate water |
| 84 | M & L for Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FR is PVC insulated copper conductor, single core cable in surface/recessed in Non metalic rigid PVC conduit as required |
| 85 | 2x2.5 sq.mm + 1x2.5 sq. mm earth wire |
| 86 | 2x4.0 sq.mm + 1x4.0 sq. mm earth wire |