Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Excavation in foundation in ordinary soil (Loam, clay or sand) including lift upto 1.50 metre and lead upto 50 m and including filling, watering and ramming of excavated earth into the trenches or into the space between the building and the sides of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by the Engingeer-in charge upto a distance of 50 m from the foundation trenches. |
| 2 | Providing & laying cement concrete 1:4:8 (1 cement :4 coarse sand:8 graded Stone ballast 40mm nominal size) including supply of all materials labour & T & P etc required for proper completion of the work and curing complete also including cost of formwork in foundation & floors. |
| 3 | Sand filling in plinth including supply of necessary quantity of sand to the site of work and including watering, dressing etc rate to include cost of all materials labours, T & P etc required for proper completion of work. |
| 4 | Providing and injecting chemical emulsion for pre constructional antitermite treatment and creating a chemical barrier under and alround the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete.(plinth area of the building at ground floor only shall be measured as per I.S.6313 (PartII 1981) Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or Chlordane will be used. The rate of application of chemical emulsion shall be as follows : (1) Treatment for masonary & foundation 5 liters per sqm. (2) Back fill in immediate contact with foundation 7.5 liters/sqm (3) Treatment of top surface of plinth filling 5 liters/sqm (4) Treatment junction of wall and the floor 7.5 liters /sqm (5) Treatment of soil along external perimeter of building 7.5 liters/sqm (6) Treatment of soil under apron along external perimter 5 liters/sqm. (As per manufacturer\"s standard dilution) |
| 5 | R.C.C. work with cement, approved coarse sand and 2 cm. guage approved stone grit in the proportion of 1:1.5:3 in plinth andlintels of doors and windows excluding supply of reinforcement and its fixing and binding the same with 24 BWGGI binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labours, tools and plants etc, required for proper completion of the works. |
| 6 | R.C.C. work with cement approved coarse sand and 2 cm. guage approved stone grit in the proportion of 1:1.5:3 in slab excluding supply of reinforcement and its fixing and binding the same with 24 BWGGI binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labours, tools and plants etc, required for proper completion of the works. |
| 7 | R.C.C. work with cement approved coarse sand and 2 cm. guage approved stone grit in the proportion of 1:1.5:3 in lighter beam i.e. having span above 6m, excluding supply of reinforcement and its fixing and binding the same with 24 BWGGI binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labours, tools and plants etc, required for proper completion of the works. |
| 8 | R.C.C. work with cement approved coarse sand and 4 cm. guage approved stone grit in the proportion of 1:1.5:3 in foundation and footing excluding supply of reinforcement and its fixing and binding the same with 24 BWGGI binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labours, tools and plants etc, required for proper completion of the works. |
| 9 | R.C.C. work with cement approved coarse sand and 2 cm. guage approved stone grit in the proportion of 1:1.5:3 in Column excluding supply of reinforcement and its fixing and binding the same with 24 BWGGI binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labours, tools and plants etc, required for proper completion of the works. |
| 10 | Class-150 brick work in 1:6 (one cement and six coarse sand sand of 1.5-2.25 fineness modulus) mortar infoundation & plinth including supply of all materials, labours, T & P etc required for proper completion of the work. |
| 11 | Class-150 brick work in 1:6 (one cement and six coarse sand sand of 1.5-2.00 fineness modulus) mortarin super-structure includingnecessarycutting and moulding of brick work asrequiredand also including honeycombed brick work. Thickness of wall not to be less than one brick thick wallincluding supply of all material labours,T & P etc required for proper completion of work. |
| 12 | 40mm thick Cast cement concrete in 1:2:4 cement, coarse sand of 2.20-3.60 FM and 20 mm graded stone grit comlete including supply of all materials, labour and T&P etc required for proper completion of work. |
| 13 | Class-150 brick work in 1:4 (one cement and 4 coarse sand sand of 1.5-2.00 fineness modulus) mortarin super-structure includingnecessarycutting and moulding of brick work asrequiredand also including honeycombed brick work. Thickness of wall not to be less than one brick thick wallincluding supply of all material labours,T & P etc required for proper completion of work. |
| 14 | RFT steel or TMT BARin plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including binding for proper completion of the work and including supply of steel its wastage bend, hooks and authorised over lapping shall be measuredincluding supply of all material labours, T & P etc required for proper completion of work.(Including cost of binding wire) |
| 15 | 12mm thick plaster with cement mortar consisting of 1 part cement and 4 part of approved coarse sand including supply of all material labours, T & P etc required for proper completion of work. |
| 16 | 12mm thick plaster with cement mortar consisting of 1 part cement and 6 part of approved coarse sand including supply of all material labours, T & P etc required for proper completion of work. |
| 17 | 12mm thick plaster with cement mortar consisting of 1 part cement and 6 part of approved coarse sand including supply of all material labours, T & P etc required for proper completion of work. (Outer side) |
| 18 | Making groove 10mm to 12mm wide and 8mm deep in plaster of wall or in ceiling vertically and horizontally as required |
| 19 | 62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete. |
| 20 | 25mm thick Kota stone slab flooring over 20 mm (1 :3 cement :coarse sand)(average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing omplete with base of cement mortar 1 : 3 (1 cement : 3coarse sand) : 25 mm thick |
| 21 | Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, ncluding rubbing and polishing complete. |
| 22 | Supply & fixing 6mm China white glazed ceramic tiles in flooring or in skirting or dado laid with 1:3 cement and approved coarse sand mortar finished with white cement slurry jointing and polishing complete including supply of all material labour and T & P et required of proper completion of the work. |
| 23 | 25mm thick 1:2:4 cement concrete floor with cement approved coarse sand and 2 cm graded approved stone ballast laid in panels finished with 3mm floating coat of neat cement or cement and marble dust in ratio of 5:1 as excluding base concrete and removing any overlapping mortar at the joints of panels if any giving them a uniform finish including supply of all materials labour T & P etc required for proper completion of the work. |
| 24 | P & F of vitrified floor tiles Kajaria KERRO brand or Equivalent brand of super quality in different size (thickness specified by manufacturer) with water absorption less than 0.8% and conforming to IS 15622 of approved make in all colours & shade laid on 20mm thick cement mortar 1:4 ( 1cement : 4 coarse sand) including grouting the joint with white cement cement and matching pigments etc complete.(size of tiles 600 x 600mm) for Flooring complete in all respect. |
| 25 | P & F of vitrified floor tiles Kajaria KERRO brand or Equivalent brand of super quality in different size (thickness specified by manufacturer) with water absorption less than 0.8% and conforming to IS 15622 of approved make in all colours & shade laid on 20mm thick cement mortar 1:3 ( 1cement : 3 coarse sand) including grouting the joint with white cement cement and matching pigments etc complete.(size of tiles 600 x 600mm) for Skirting complete in all respect. |
| 26 | Supply & fixing of 32 mm thick flush doors commercial quality conforming to IS 2202 part I (1983) including fixing of wooden cleats & stoppers and including fixing and adjustment of hinges. Bolts locks handles springs. Fitting with necessary screws to be supplied departmently. |
| 27 | M.S. or Iron work of small sizes and sections such as holding down bolts, hold fast tie rods, gratings etc.(when not included in an over all rates) wrought to required from including supply of steel and its wastage etc and their fixing required for proper completion of work. Providing & fixing of hold fast for chaukhatsof doors and windows. |
| 28 | M.S. or Iron work of small sizes and sections such as holding down bolts, hold fast tie rods, gratings etc.(when not included in an over all rates) wrought to required from including supply of steel and its wastage etc and their fixing required for proper completion of work. Fabrication and supply & fixing of mild steel grill as per design. |
| 29 | M.S. or Iron work of small sizes and sections such as holding down bolts, hold fast tie rods, gratings etc.(when not included in an over all rates) wrought to required from including supply of steel and its wastage etc and their fixing required for proper completion of work. Fabrication of Z-section Steel window |
| 30 | Fabrication and supply of angle-iron 40x40x5mm doo/window chaukhat M.S. or Iron work of small sizes and sections such as holding down bolts, hold fast tie rods, gratings etc.(when not included in an over all rates) wrought to required from including supply of steel and its wastage etc and their fixing required for proper completion of work. frame . |
| 31 | Fixing Chowkhats in existing opening including complete as per direction of Engineer in charge. Door chaukhats |
| 32 | Fixing Chowkhats in existing opening including complete as per direction of Engineer in charge. Window chaukhats |
| 33 | Fixing Chowkhats in existing opening including complete as per direction of Engineer in charge. Ventilator chaukhats |
| 34 | Distemper one coat with oil bound distemper of approved brand manufacture and required shade on decorated wall surfeces to give an even shade over and including a priming coat with cement primer of approved brand including coat of all material with extra one coat after pervious one coat |
| 35 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shadeNew work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) |
| 36 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete |
| 37 | Making drip course in sun shade or facia as per direction of Engineer inchage including supply of all material |
| 38 | Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete. |
| 39 | Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete300x16 mm |
| 40 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 150x10mm |
| 41 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : |
| 42 | Providing And laying Brick coba 12mm thick laid with M-150 classbrick bat coba 7.5cm thick with gap of 15mm to each other over 20mm thick base of cementmortar1:4 cement and coarse sand mixed with water proofing compound spreading cement slurry mixed with aerelic cement concrete water proffing compound filled gaps of coba and top of coba mortar mixed with water proofing compound in 1:4 cement and coarse sand mortar finished smooth and top square marks 30cm x 30cm and side wall parapet shall be monolithic plaster wall upto 30cm higher and junction and corner shall be rounded by brick ballast cement and coarse sand masonary & coba with top finished plaster mixed with acetic water proofing compound @ 2% by weight & includung S/o all material and labour T&P etc complete for proper completion of work |
| 43 | Painting or varnishing new iron work in small areas with one coat (up to one sq. meter) of ready mixed priming paint and one coat of approved superior quality ready mix paintof clear synthetic varnish including supply of all materials, labours, T & p etc. required for proper completion of work paint to be used. |
| 44 | Painting or varnishing new wood work in small areas with one coat (up to one sq. meter) of ready mixed priming paint and one coat of approved superior quality ready mix paintof clear synthetic varnish including supply of all materials, labours, T & p etc. required for proper completion of work paint to be used. |
| 45 | Providing & fixing 4mm thick glass panes with putty and glazing clips in steel doors, windows, clerestory windows, with : 4.0 mm thick glass panes with brad, putty, clips etc. required including supply of all materials, labours, T&P etc. complete in all respect. |
| 46 | Providing and fixing glass strips ofof floorwith floor level including labour,tools,plants etc. complete. 5.5cm thick and 2.2cm depth |
| 47 | Supply & fixing of rolling shutter of approved make, made of required size 80x1.25 mm thick M.S. laths inter locked through their entire length and joined together at the end locks and mounted on specially designed pipe shaft with brackets side guides and arrangements for inside and outside locking with push and pull operation complete and and |
| 48 | i/c the cost of providing & fixing necessary 27.5 cm long wire spring manufactured from high tensile steel wire of adequate strength confirming to IS: 4454 - part 1 (grade -2 ) |
| 49 | M.S. top cover of required thickness for rolling shutters 18 gauge |
| 50 | ball bearing for rolling shutter |
| 51 | Providing & fixing fly proof galvanized M. S wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4mm in both direction with wire of dia 0.63mm all complete with 12mmm mild steel U beading |
| 52 | Constructionof drain of Ck type along with apron |
| 53 | Providing and fixing M Swork or iron work in small size and section such asrailing made of Hollow tubes, square pipes , channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessarysteel nuts and bolts complete, i/c fixing the railing with necessary accessories &steel dash fasteners ,steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, |
| 54 | Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc.,by applying cement slurry mixed with water proofing cement compound consisting of applying: (a) first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm.This layer will be allowed to air cure for 4 hours. (b) Second layer of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonary with polymer mixed slurry as per |
| 55 | Providing & laying of light cinder/coal filling under floor of toilets and other sunken roofs.as per |
| 56 | Washed stone grit plaster on exterior walls height upto 10 metre above ground level, in two layers, under layer 12 mm cement plaster 1:4 (1 cement : 4 coarse sand ), furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 2 Kg of cement per square metre, top layer 15 mm cement plaster 1:1/ 2:2 (1 cement: 1/2 coarse sand : 2 stone chipping 10 mm nominal size), in panels with groove all around as per approved pattern, including scrubbing and washing the top layer with brushes and water to expose the stone chippings ,complete as per specification and direction of Engineer-in-charge (payment for providing grooves shall be made separately). |
| 57 | Finishing boundary wall with water proof cement paint of approved make and quality on new work with two coats to give an evenshade including preparing surface by the throughly cleaning & sand preparing and supply of all T&P & labour, required for proper completion of work and for each coat of water prooof painty after the first two coat to give even shade |
| 58 | Providing and laying design mix cement concrete of M-30 grade, in roads/ taxi tracks/ runways, using cement content as per design mix, using coarse sand and graded stone aggregate of 40 mm nominal size in appropriate proportions as per approved & specified design criteria, providing dowel bars with sleeve/ tie bars wherever required, laying at site, spreading and compacting mechanically by using needle and surface vibrators, levelling to required slope/ camber, finishing with required texture, including steel form work with sturdy M.S. channel sections, curing, making provision for contraction/ expansion, construction & longitudinal joints (10 mm wide x 50 mm deep) by groove cutting machine, providing and filling joints with approved joint filler and sealants, complete all as per direction of Engineerin-charge (Item of joint fillers, sealants, dowel bars with sleeve/ tie bars to be paid separately). Note:- Cement content considered in M-30 is @ 340 kg/cum. Excess/ less cement used as per design mix is payable/ recoverable separately. |
| 59 | Mild Steel or iron work of small size and section such as holding down bolts hold fast tie roads gratings etc (when in included in overall rates) wrought to required form including supply of steel bolts nuts and wastages etc and its fixing required for proper completion work. |
| 60 | Providing and fixing white vitreous china pedestal type water closet ( Indian type W.C. pan ) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:W.C. pan with ISI marked white solid plastic seat and lid. |
| 61 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar pillar tap. |
| 62 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 63 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet100 mm diameter |
| 64 | Providing and Fixing Stainless Steel grating of approved quality and colour. 125 mm diameter |
| 65 | Providing and fixing CP Brass 32 mm sizeBottal Trap of approved quality & make and as per thedirection of Enginer-in-charge. |
| 66 | Providing and fixing CP Brass Single lever lelephonic wall mixture of quality & make and as per thedirection of Enginer-in-charge. 15mm dia nominal dia. |
| 67 | Providing & fixing PTMT towl rail complete with brackets fixed to wooden cleats with cp brass screws with concealed fitting arrangement of approved quality and colour. 600 mm. long towl rail length of 645 mm. width 78 mm. and effective height of 88 mm, weighing not less than 190 gms. |
| 68 | Providing and fixing PTMT Liquid soap container 109 mm wide ,125 mm high and 112 mm distance from wall of standerd shape with bracket of the same material with snap fittings of approved quality and colour weighing not less than 105 gms |
| 69 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion . (i) Single socketed pipes. 110mm diameter |
| 70 | Supply and fixing of UPVC S.W.R. pipe type-B confirming to IS-13592 including jointing the pipes with rubber ring,lubricant and UPVC SWR cupler confirming to IS-14735. Also including excavation of treanches cutting of walls and holes and repairing the walls,floors and refilling the trenches as before but excluding supply and cost of other fIttlings such as elbow,bend,tee and y-tee including supply of al marerial labour and T&P.Required for proper completion of work. 90 mm O.D. |
| 71 | Supply and fixing of UPVC S.W.R. pipe type-B confirming to IS-13592 including jointing the pipes with rubber ring,lubricant and UPVC SWR cupler confirming to IS-14735. Also including excavation of treanches cutting of walls and holes and repairing the walls,floors and refilling the trenches as before but excluding supply and cost of other fIttlings such as elbow,bend,tee and y-tee including supply of al marerial labour and T&P.Required for proper completion of work. 110 mm O.D. |
| 72 | Supply and fixing of UPVC S.W.R. pipe nahni trap size 100x75,110/90 mm confirming to IS-14735 self cleaning design fixed in PCC 1:2:4 and supply and fixing of 125 mm dia heavy duty CP brass jali. |
| 73 | Supply and fixing of UPVC S.W.R. plain bend confirming to IS-14735. Size 90 mm |
| 74 | Supply and fixing of UPVC S.W.R. plain bend confirming to IS-14735. Size 110 mm |
| 75 | Supply and fixing of UPVC S.W.R. Cowel confirming to IS-14735. Size 90 mm |
| 76 | Supply and fixing of UPVC S.W.R. Cowel confirming to IS-14735. Size 110 mm |
| 77 | Supply and fixing of UPVC S.W.R. plain tee confirming to IS-14735. Size 90x90x90 mm |
| 78 | Supply and fixing of UPVC S.W.R. plain tee confirming to IS-14735. Size 110x110x110 mm |
| 79 | Supply and fixing of UPVC S.W.R. plain Y confirming to IS-14735. Size 90 mm |
| 80 | Supply and fixing of UPVC S.W.R. plain Y confirming to IS-14735. Size 110 mm |
| 81 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over PVC sheet 1m x 1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement,punning,rounding the edges and making and finishing the outlet complete.110mm |
| 82 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110mm |
| 83 | Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. |
| 84 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work-Exposed on wall 15mm dia nominaldia pipes |
| 85 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work-Exposed on wall 25mm dia nominaldia pipes |
| 86 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge. Concealed work including cutting chases and making good the walls etc. 15mm dia nominal outer dia pipes |
| 87 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge. Concealed work including cutting chases and making good the walls etc. 20mm dia nominal outer dia pipes |
| 88 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge. Concealed work including cutting chases and making good the walls etc. 25mm dia nominal outer dia pipes |
| 89 | Providing & fixing CP brass bib cock of approved quality conforming to IS 893115mm nominal bore |
| 90 | Providing & fixing C.P. brass angle valve for basin mixer and gyser points of approved quality conforming to IS 8931 15mm nominal bore |
| 91 | Providing and fixing gun metal gate valve with wheel of approved quality(screwed end).. 25mm dia nominal bore |
| 92 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete 25 mm nominal bore |
| 93 | Supply and hoisting of Sintex or equivalent high densitypolyethylene seemless of piece moulded tanks and placing the same in proper position including all taxes, labour and T&P etc. for proper completion of work. Tnak should be ISI marked, Sintex or equivalent. |
| 94 | Providing and fixing gun metal gate valve with wheel of approved quality. 20 mm dia nominal bore |
| 95 | Providing and fixing PTMT pillar cock of approved quality and colour.15 mm nominal bore, 125 mm long foam flow, weighingnot less than 120 gms |
| 96 | Supply and fixing of UPVC S.W.R. pipe type-B confirming to IS-13592 including jointing the pipes with rubber ring,lubricant and UPVC SWR cupler confirming to IS-14735. Also including excavation of treanches cutting of walls and holes and repairing the walls,floors and refilling the trenches as before but excluding supply and cost of other fIttlings such as elbow,bend,tee and y-tee including supply of al marerial labour and T&P.Required for proper completion of work.a) Pipes 80mm to 300mm diameter. 110 mm diameter |
| 97 | Supply and fixing of UPVC S.W.R. pipe type-B confirming to IS-13592 including jointing the pipes with rubber ring,lubricant and UPVC SWR cupler confirming to IS-14735. Also including excavation of treanches cutting of walls and holes and repairing the walls,floors and refilling the trenches as before but excluding supply and cost of other fIttlings such as elbow,bend,tee and y-tee including supply of al marerial labour and T&P.Required for proper completion of work.a) Pipes 80mm to 300mm diameter. 160mm diameter |
| 98 | Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W R. pipes including bed concrete as per standard design :100mm dia. S.W R. Pipe in |
| 99 | Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W R. pipes including bed concrete as per standard design :(assume as item no 19.2 DSR 2023) 150mm dia. S.W. R Pipe in |
| 100 | Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design 100 x 150 mm. dia. |
| 101 | Constructing brick masonry House connecting chambers size 450x450x600mm with 9\" brick work walls in cement mortar 1:6 (1 cement :6 coarse sand) RCC top slab 8 cm thick with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 10 cm thick with 1:6:12 mix (1 cement :6 coarse sand :12 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard designInside size 450x450X600mm and 500mm deep including R.C.C. Cover. |
| 102 | Wiring point for light with 1.5 sq.mm FR P.V.C. insulated multistrandsingle core Copper Conductor cable in PVC conduit with 1.5 sq.mm. FRLSH PVC insulated multistrand copper conductor cable as earthing wire drawn inside the conduitpartly concealedin wall&partlylaidin slab along with the reinforcement before concreting,complete with modular typeswitch & ceiling rose / angle / batten holder on 3 mm thick phenolic laminated backelite sheet etc complete in all respects as directed, including matching color wash. |
| 103 | Wiring point for two ways light with 1.5 sq.mm FRLSH PVC insulated multistrandsingle core Copper Conductor cable in PVC conduit pipe partly concealedin wall&partlylaidin slab along with the reinforcement before concreting,complete with 1.5 sq.mm. FRLSH PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduitpartly concealedin wall&partlylaidin slab along with the reinforcement before concreting,complete with modular typeswitch & ceiling rose / angle / batten holder on 3 mm thick phenolic laminated backelite sheet etc complete in all respects as directed, including matching color wash |
| 104 | Wiring point for fan with 1.5 sq.mm FRLSH PVC insulated multistrandsingle core Copper Conductor cable in PVC conduit pipe partly concealedin wall&partlylaidin slab along with the reinforcement before concreting,complete with 1.5 sq.mm. FRLSH PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduitpartly concealedin wall&partlylaidin slab along with the reinforcement before concreting,complete with modular typeswitch & ceiling rose / angle / batten holder on 3 mm thick phenolic laminated backelite sheet etc complete in all respects as directed, including matching color wash |
| 105 | Wiring point for exhaust fan with 1.5 sq.mm FRLSH PVC insulated multistrandsingle core Copper Conductor cable in PVC conduit pipe partly concealedin wall&partlylaidin slab along with the reinforcement before concreting,complete with 1.5 sq.mm. FRLSH PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduitpartly concealedin wall&partlylaidin slab along with the reinforcement before concreting,complete with modular typeswitch & ceiling rose / angle / batten holder on 3 mm thick phenolic laminated backelite sheet etc complete in all respects as directed, including matching color wash |
| 106 | Wiring point for plug 1.5 sq.mm FRLSH PVC insulated multistrandsingle core Copper Conductor cable in PVC conduit pipe partly concealedin wall&partlylaidin slab along with the reinforcement before concreting,complete with 1.5 sq.mm. FRLSH PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduitpartly concealedin wall&partlylaidin slab along with the reinforcement before concreting,complete with modular typeswitch & socket etc, complete in all respect including matching colour wash. |
| 107 | Add for Invertor Wiring in wiring Point for light/Fan with 1.5 mm Cu Wire |
| 108 | Supply & wiring of submains with two number2.5 sq.mm FRLSH PVC insulated 1100 V grade single core multistrand copper conductor cable in 20mm dia heavy duty (2mm thick)PVC conduit with 1 Number 1.5 sq.mm. FRLSH PVC insulated 1100 V grade multistrand copper conductor cable as earth continuity wire drawn inside the conduitcomplete in all respect. |
| 109 | Supply & wiring of submains with two number4 sq.mm FRLSH PVC insulated 1100 V grade single core multistrand copper conductor cable in 20mm dia heavy duty (2mm thick)PVC conduit with 1 Number 2.5 sq.mm. FRLSH PVC insulated 1100 V grade multistrand copper conductor cable as earth continuity wire drawn inside the conduitcomplete in all respect. |
| 110 | Supply and wiring of submain with 4 number 10 sqmm . FRLSH PVC insulated 1100 V grade multistranded single core copper conductor cable in32 mm dia heavy duty (2mm thick ) PVC conduitpartly concealed in wall and partly laid in slab along with reinforcement befor concreting with two number 10 SWG copper earth contunity wire including colour wash etc. complete in all respects. |
| 111 | Supply & fixing of single wall bracketon matching M.D.F.E.G.boardbase etc. complete in all required. Cat. A |
| 112 | Supply & fixing ofrecess/Surface/Pendent mounting round 12 to 15 watt LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/Reflector and driver set complete in all respects. Cat. AAA |
| 113 | Supply and Fixing of LED Tube Light with batten suitable for up to 1X22 watt LED tube light fitting complete including tube on surface complete in all respect. 1 X 22 W CAT-AAA |
| 114 | Supply, Installation, Testing and Commissioning of 1200mm sweep, BEE 5 star rated, ceiling fan with Brush LessDirect Current (BLDC) Motor, class of insulation: B, 3 nos.blades, 30 cm long down rod, 2 nos. canopies, shackle kit,safety rope, copper winding, Power Factor not less than0.9, Service Value (CMM/W) minimum 6.85, Air deliveryminimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulatorunit for speed control and all remaining accessoriesincluding safety pin, nut bolts, washers, temperaturerise=75 degree C (max.), insulation resistance more than2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required BEE 5 Star rated-1200mm sweep |
| 115 | Supplyand burying safe earthing Electorde T-19 (HotDip Galvanized), Length 2000 mm, outer pipe 50mm, inner pipe 25, terminal Dia 12mm ,outer G.I.pipe of 16 swg and inner GI pipe of12swg withHotDipGavanized up to 100 mirconfilled withcrystalline conducative mixture (CCM) having anti corrosive & conducative property with 50 kgs activated soil (BFC) capable ofreducing the soilresistivitywith good mixture ofretaning capacity along with 30 cm squre C.I. frame with hinged cover & masonryhousing (from electode terminaltoswitch board , cost of 25 x 3 G.I. strip will be extra) Make:As approved in U.P.P.W.D. & C.P.R.I. Certified |
| 116 | Supplying & Laying of 25mmx3mm G.I. Strip from earth electrode in ground as required complete in all respects. |
| 117 | Supply & fixing of two number 8 SWG G.I. wire for earthing purpose as required complete in all respects. |
| 118 | Supply and fixing of 6 Amp to 32 Amp MCB(10KA)C Curve 6 - 32 amps.Cat. A |
| 119 | Supply and fixing of 63 Amp. 4 Pole MCB (10KA) CAT A |
| 120 | Supply and fixing of surface/ flush mounting 6 way TPN distribution board with additional metal doorwithout MCB complete in all respect, as directed at site by Engineer Incharge. CAT A |
| 121 | Supply & fixing of Crimping, solder, less, copper ton electroplated lugs of Dowel/ismail make suitable for 1.5 sqmm to 6sqmm cables, including tapping with insulating tape,etc. complete in allrespects. |
| 122 | Supply and fixing of single pole MCB blanking plate CAT A |
| 123 | Supply and fixing of power plug with 20A/250 V flush type modular switch and 5 Pin 20 A/250 Volt flush type universal modular socket switch on concealedM.S. box including supply of all material, labour T & P etc required for proper completion of work. |
| 124 | Erection and testing of ceiling fan and regulator for room height upto 3.5mts. including supply of 3mm thick G.I. down rod 19mm dia duly painted, complete in all respects. |
| 125 | Erection and testing exhaust fan on the exhisting hole with suitable size of rag bolts nuts and washers etc. complete in all respects. |
| 126 | Supply & fixing of 16 gauge M.S.drum duly painted including making hole in the wall for exhaust fan and finishing properlyetc. complete as required. |
| 127 | Supply & fixing hexagonal/Round G.P. Fan box of approved make made up of 1.0 mm thick ISI marked G.P. Sheet spot welded four to Eight holes of 25.4mm for pipe entry of the box. Holes should be semi-shuttered type with 0.5mm G.P. Sheet made upper & lower cover duly screwed fitted with 300mm round zink coated M.S. Bar x 12mm & brand name should be embossed. Fixing with wiring conduit laid in the R.C.C. roof before concreting alongwith supply of all material labour, T & P etc required for proper completion of the work. |
| 128 | Supplyfixingofelectronic fan regulator (Modular) 120-280 V. ISImarked, on the existing switch board including making connetion, required material, labour T/P etc for proper completion of work to the satisfaction of Engineer in charge of work. |
| 129 | Supply and fixing of surface/ flush mounting 6 ways V TPN distribution board with additional metal doorwithout MCB complete in all respect, as directed at site by Engineer Incharge. CAT A |
| 130 | Supply and fixing of 160 Amp 4 pole MCCB(25 KA) Theramal Magnetic reaease Cat. A |
| 131 | Supply and laying of aluminium conducter, PVC insulated armoured, served, sheeted cable 1000 bolts grade at a depth of 750mm below ground level over a cushion of 75mm thick sand alround and protected with burnt bricks on sides and top on surface, the cable run shall be fixed on M.S. clamps etc. of suitable size. or as directed by the Engineer-Incharge, complete in all respect. the armouring of the cable shall be properly connected with the earth conductor by clamps etc.25 sqmm 3.5 core |
| 132 | S&F surface/flush mounting 4 ways SPN distribution board without MCB complete in all respect,as directed at site by Engineer in charge CAT A |
| 133 | Supplying and drawing following pair 0.5 sqmm FR PVC insulated annealed copper conductor, unarmoured telephone cable in the existing surface/recessed steel/PVC conduit as required. 2 Pair |
| 134 | Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep) and refilling etc as required. 100 mm Dia |
| 135 | Supply & erection of AC 230/250 Volts, 50 Hz exhaust fans including providing nuts, bolts, mounting frame and other accessories including connections etc. complete as required-Make: USHA Cat No. TURBO JET DLX 300mm sweep. |
| 136 | S/f of 10/20 pair Junction Boxes for Floors and building with Krone connectors , with connection and punching of same |
| 137 | Excavation in foundation in ordinary soil (Loam, clay or sand) including lift upto 1.50 M & lead up to 30m including filling watering & rammig of excavated earth into the trenches or in to the space between the building & the side of foundation treches or into the plinth & removal & disposal of surplus earth as direction by E/1 up to distance of 30m from the foundation treches. 0.00 to 1.50 Mt. |
| 138 | Excavation in foundation in ordinary soil (Loam, clay or sand) including lift upto 1.50 M & lead up to 30m including filling watering & rammig of excavated earth into the trenches or in to the space between the building & the side of foundation treches or into the plinth & removal & disposal of surplus earth as direction by E/1 up to distance of 30m from the foundation treches. 1.50 to 3.0 Mt. |
| 139 | Providing and laying in cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) and curing complete, including cost of form- work, in foundation and floors. |
| 140 | R.C.C. work with cement approved coarse sand and 2 cm. guage approved stone grit in the proportion of 1:1.5:3 in slab excluding supply of reinforcement and its fixing and binding the same with 24 BWGGI binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labours, tools and plants etc, required for proper completion of the works. |
| 141 | M-150 class brick work in 1:4 cement coarse sand of 1.50 - 2.00 F.M mortar in foundation and plinth including supply of all materials, labour and T&P etc. required for the proper completion of the work. |
| 142 | Mild steel or TMT BARin plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including binding for proper completion of the work and including supply of steel its wastage bend, hooks and authorised over lapping shall be measuredincluding supply of all material labours, T & P etc required for proper completion of work.(Including cost of binding wire) |
| 143 | 12 mm cement plaster in single coat on rough side of single or half brick wall finished with a floating coat of neat cement. (1) 1 cement : 4 Coarse sand |
| 144 | Supply & Laying of 40 mm gauge over burnt stone ballast including all materials, labour and T&P etc. for proper completion of the work. |
| 145 | Providing M.S. foot rests including fixing in manoholes with 20x20x10 cm cement concrete blocks 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) as per standard design:(With 20x20mm square bar) |
| 146 | Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality. Circular shape 500 mm internal diameter |
| 147 | Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level.. Drilling of 300mm dia bore hole manually. |
| 148 | Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 150 mm nominal size dia |
| 149 | Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. |
| 150 | Excavation in foundation in ordinary soil (Loam, clay or sand) including lift upto 1.50 M & lead up to 30m including filling watering & rammig of excavated earth into the trenches or in to the space between the building & the side of foundation treches or into the plinth & removal & disposal of surplus earth as direction by E/1 up to distance of 30m from the foundation treches. |
| 151 | Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) includingesting of joints etc. complete150 mm dia. R.C.C. pipe |
| 152 | Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I.surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:1.5:3 mix (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size), including necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design :With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy