| 1 | 33KV single core 300sqmm , aluminium,round wire armoured XLPE UG cable FRLS |
| 2 | Straight through joint for cables 2 nos for single core (compound) |
| 3 | Route indicator |
| 4 | Warning tape |
| 5 | Cable termintation kits (Indoor/outdoor) |
| 6 | Excavation of any type of soil including laterite soil |
| 7 | Back filling of available excavated earth |
| 8 | Sand for cushioning of HT under ground cables |
| 9 | Mechanical transport 30kms of sand |
| 10 | Head load 100mtrs of sand |
| 11 | GI pipe 150mm dia with required no of collars for road crossing including termination points |
| 12 | RCC protective cover of size (300mm width x 300m length x 60mm thickness) for under ground cable. |
| 13 | Brick masonary chamber 900x900x1050)mm with RCC TOP slab, cast iron cover in CI Frame (31kg) after 500mtrs |
| 14 | Earthing electrode with B.F.C for 01 no earthing |
| 15 | Reinstallments of roads (1mx0.7mx0.2m)=14cums |
| 16 | 33 KV 1 core 300 sqmm A I conductor , XLPE , insulated armored cable (From the RMU to receiving substation) with 33 KV MU:Outdoor type RMU SF 6 insulated, Extensible type, at 33 KV system voltage and breaking capacity 25 KA for 1 sec With SF 6 circuit breaker/VCB self powered with O/C+E/F Relay system comprising ofa) 33 KV, 630 A Motorised isolators Including earthing swatches with making capacity 62.5 KA , having mechanical on/off b) 33 KV 200 AMotorised spring operated circuit Breakers with earthing switchesc) CU bus - Bar of 630 A Ratingd) 1 no Numerical aux, Self powered relay having non directional O/C And E/F Protection for each CB feeder. e) Incoming isolators should have FPI With electrical Reset facilityf) All necessary potential free contacts for indications relevant to RMU monitoring and control g) Capacitor voltage Divider serving line - line cable indicators in each breaker and isolator. 2) 33 KV single core in door terminating kits 3) 33 KV single core outdoor terminating kits 4) Rout marker 5) Warming tape6) Cable termination kits (Indoor/Outdoor) 7) Excavation of any type of soil including hard laterite soil8) Backfilling of available excavated earth9) Sand for cushioning of HT underground cables10) Mechanical transport of sand11) Head load 100 mtrs of sand12) GI pipe 150 mm dia With required no of collers For road crossing including termination points13) RCC protective cover off size 300 mm (Width) x 300 mm (Length) x 60 mm (Thickness) For underground cable14) Brick masonry chamber (900 X 900 X 1050) mm With RCC15) Top slab cast iron cover in CI frame (38 kg) 16) Earthing complete by GI pipe 40 mm , 3 mtr Long through GI strip (25x3) mm. 17) Reinstatement of roads (100 m x 0.7 m x 0.2 m) = 14 cums. |
| 17 | Support GI PIPE POLE OF 11 MTRS |
| 18 | Double GI Pipe Pole Structure at Disc Points on 10 meters pole. |
| 19 | support structures G1 Channelfor 11/3kVHT (l00x50x6mm)1. 7mtrs |
| 20 | GI channelfor LT single cross ams (75x40x6mm)1.5 mtrs |
| 21 | GI Channel for HT pole cross bracing ( 75x40x6mm) |
| 22 | Gl flat for Clamps (80/l00mmx8mm} |
| 23 | GI clamps (75x8mm) |
| 24 | GI Nul bolt16mm (5/8) 100mm |
| 25 | GI Nul bolt16mm (5/8) 800mm |
| 26 | GI Nul bolt16mm (5/8) 65mm |
| 27 | GIwasher 6mm (5/8) |
| 28 | Earthing set complete |
| 29 | GI stay set complete HT |
| 30 | Anti Climbing Devices |
| 31 | Foundation materials for muffins; |
| 32 | Conductors and condutors Accessories AAA Conductor80Sq.mm 7/3.81 mm |
| 33 | AA I conductors 7/2.5 mm |
| 34 | PG clamps |
| 35 | Danger plates |
| 36 | Insulators and insulating materials 33KVPinInsulator(PorcelainType) with pin as per ISS |
| 37 | 33kv Disc insulator (porcelain type) with hard ware as per ISS |
| 38 | LT insulator(porcelain type) as per ISS |
| 39 | LT Shackle insulator with hardware |
| 40 | PVC Twice Core Service wire 8/10 mm |
| 41 | Out door11KV HT Metering ArrangementwithCT 150/5A andPT 11KV/10V along with pre - programmedMeter |
| 42 | G.I Pipe pole 11 meters |
| 43 | G.l. Channel (75x40x40x6mm) |
| 44 | G.1 Channel (l00x50x50x6mm) |
| 45 | GI angel to support transformer channeldistribution 8ox (50x50x6) |
| 46 | G.l. clamp |
| 47 | G.l. bolts & Nuts & Washer16 mm (5/8) 100 |
| 48 | G.I. strip 25x3 mm |
| 49 | 11kVdisc insulator (porcelaintype) withpin asperISS |
| 50 | 11 KV strain clamps complete with ball sleeved andsocket eye |
| 51 | 11KV lightning arrester |
| 52 | 11KV, 200 amps Horn Gap DO fuse |
| 53 | 1 IkV ABS set |
| 54 | LT distributionBox inclusive ofBusbar, cutouts,metering etc |
| 55 | DT installationon plinthmounted |
| 56 | Earthing electrode with black fillcompound |
| 57 | Foundationmaterials for MufFing |
| 58 | GI pipe pole 11meteres |
| 59 | GI Channel for double cross arm(100mmx50x6mm) 3 mtrs |
| 60 | GI clamp 75x8mm |
| 61 | GI Nut and bolt wiyh washer 16mm (5/8) 100mm |
| 62 | GI strip (25mmx3mm) |
| 63 | 11kv ABS set |
| 64 | 11KV LIGHTNING ARRESTOR |
| 65 | I I KV 200ampsHorn Gap DO fuse unit |
| 66 | 33kv ABS set |
| 67 | 33 KV LIGHTNING ARRESTOR |
| 68 | 33KV, 200amps Horn Top Do fuse unit |
| 69 | Earthing electrode with back filling compund |
| 70 | LT distribution on plinth mounted with gaurding |
| 71 | DT installation on plinthmounted (pedestial) with gaurding |
| 72 | Foundation material for muffing |
| 73 | Support Double G.I. Pipe Pole (11 Mtrs.) |
| 74 | Support Fixtures G.I. Channel for 11/33KV HT Double Cross Arm(100x50x6 mm) 3 Mtrs. |
| 75 | G.I. Channel for LT SingleCross Arm(75x40x6 mm) 1.5 Mtrs. |
| 76 | G.I. Angle Channel for Cross Bracing (50x50x6mm) 3.5 Mtrs. |
| 77 | G.I. Clamp 80/100 x 8mm |
| 78 | G.I. Clamp 75 x 8 mm |
| 79 | Bolts & Nuts & washer(5/8)16 x100 mm, 16x80mm.16x65mm ,16x50mm, FulI Thread. |
| 80 | GI nuts and washers (5/8) 16 x100mm full thread |
| 81 | Earthing Set Complete |
| 82 | G.I. Stay Sets Complete HT |
| 83 | Anti-Climbing Device |
| 84 | Foundation Materials for Muffing |
| 85 | Conductor & ConductorAccessories AAA Conductor 7/3.18 mm |
| 86 | AAA Conductor 7/2.5 mm |
| 87 | P G.Clamps |
| 88 | Danger Plate |
| 89 | Insulator & Insulator Accessories 11 KV Disc Insulator (Porcelain Type) with pin as per ISS |
| 90 | 11 KV Strain Clamps Complete with ball sleeved and socket eye |
| 91 | 33 KV Disc Insulator (Porcelain Type)with pin as per ISS. |
| 92 | 33 KV Strain Clamps Complete with ball sleeved and socl‹et eye. |
| 93 | LT Disc Insulator (Porcelain Type) with pin as per ISS |
| 94 | LT Shackle Insulator with Hardware |
| 95 | PVC Twin Core Service wire 8/10 Sqmm |
| 96 | Door 11KV HTMetering Arrangement (Rangat Feeder) with CT 15u/5A and PT 11kV/110V alone with Pre Programmed Meter at Water |
| 97 | G.I.Pipe Pole 8 mtrs. |
| 98 | G.I.Channel for Cross Arm (75x40x6mm) |
| 99 | G.I.Clamp 75x8 mm |
| 100 | G.I.Bolts & Nuts & Washer 16 mm (5/8)x100 mm |
| 101 | Earthing Set Complete |
| 102 | G.I.Stay Sets Complete |
| 103 | Danger Plate |
| 104 | AAA Conductor 7/2.5 mm |
| 105 | LT Disc Insulator (Porcelain Type) with pin as per ISS |
| 106 | Guy Insulator |
| 107 | Foundation Materials for Muffing |
| 108 | PVC Twin core Service Wire 8/10 sqmm |
| 109 | GI PIPE POLE OF 11 MTRS |
| 110 | GICHANNEL for channel for double cross arm (100x50x6mm) 3mtrs |
| 111 | GI clamp 75x8 mm |
| 112 | GI bolts and nuts and washers 16mm (5/8)x100mm |
| 113 | GIstrip 25x3mm |
| 114 | 11kv ABS SET |
| 115 | 11KV lightning arrestor |
| 116 | 11KV, 200Amps , horn gap, D.O. Fuse unit |
| 117 | 33kvabs set |
| 118 | 33kv lightning arrestor |
| 119 | 33KV, 200Amps , horn gap, D.O. Fuse unit |
| 120 | Earthing electrode with back fill compund |
| 121 | Foundation materials for muffing |
| 122 | G. I. Pipe Pole 11 Mtrs. |
| 123 | G. I. Channel ( 75x40x40x6mm) |
| 124 | G. I. Channel ( 100x50x50x6mm) |
| 125 | G.I Angle to support Transformer Channel &Distribution Box (50x50x6) |
| 126 | G. I. Clamp 75x8 mm |
| 127 | G. I. Bolts & Nuts & Washer 16mm (5/8)x100 mm |
| 128 | G.I. Strip 25x3 mm |
| 129 | 11 KV Disc Insulator (Porcelain Type)with pin as per ISS |
| 130 | 11 KV Strain Clamps Complete with ball sleeved and socket eye |
| 131 | 11 KV Lightning Arrestor |
| 132 | 11 KV, 200 Amps. Horn Gap D.O.Fuse unit |
| 133 | 11KV ABS Set |
| 134 | LT Distribution Box Inclusive of Busbar, Cout Out,Metering etc. |
| 135 | DT Installation on Plinth Mounted (Pedestal) with Guarding. |
| 136 | Earthing Electrode with Back fill compound |
| 137 | Foundation materials for muffing |