Defence Statutory Bodies & Commissions/Committees Closing in 0 days TDR #48518650

Tender For Special Repairs To Bldg No P-904 At Ins Tunir At Naval Station Karanja

Issued by Statutory Bodies & Commissions/Committees · karanja, Maharashtra
Tender Value
24.25 Lakhs
Estimated cost
Bid Submission
22 Apr 2025
0 days left
EMD
49000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
karanja → Maharashtra
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Special Repairs To Bldg No P-904 At Ins Tunir At Naval Station Karanja

BOQ

NAME OF WORK : SPECIAL REPAIRS TO BLDG NO P-904 AT INS TUNIR AT NAVAL STATION KARANJA
Sl. No. Item Description
1Material and Labour for dewatering the sump and reservoir completely to make dry and cleaning of reservoir tank, removing sludge in semi-solid state or liquid state by manually or by pressure pump including necessary arrangement of pump, and removal of sludge, if any, to a distance exc 1.5km but not exc 5km, complete all as specified and as directed by Engr-in-Charge.
2Material and Labour for chipping and cleaning of existing loose and damaged concrete surface or plaster surface carefully upto 60 mm thickness by low impact high frequency hammer or by manual chipping without damaging the existing concrete/surface including cleaning the surface by air jet and stacking & disposal of unserviceable materials to a distance exc 1.5km but not exc 5km etc complete all as specified and as directed by Engr-in-Charge.
3Taking down cement plaster of any description on brick or concrete surfaces, including raking out joints, hacking for key, scrubbing down with water, etc, complete all as specified and as directed by Engr-in-Charge.
4Material and Labour for ready mix plaster 15mm thick in cement mortar 1:4 on fair faces of brick/concrete surfaces on walls, finished even and smooth without using extra cement, complete all as specified and as directed by Engr-in-Charge.
5Material and Labour for ready mix plaster 20mm thick incement mortar1:4 mixed with and including integral water proofing admixture @ 200ml per bag of cement on fair faces of brick/concrete surfaces of wall, finished even and smooth and with moist curing, complete all as specified and as directed by Engr-in-Charge.
6Material and Labour for ready mix plaster 10mm thick in cement mortar1:3 mixed with and including integral water proof admixture @ 200ml per bag of cement as in ceiling, finished even and smooth without using extra cement and withmoist curing of the surface complete all as specified and directed by Engr-in-Charge.
7Material and Labour for providing and fixing welded MS wire mesh weighing not less than 1 kg/sqm on the prepared surface which should be cleaned and should be removed from dirt, fungus and all foreign material, complete all as specified and as directed by Engr-in-Charge.
8Material and Labour for Providing and applying jacketing around columns with Micro concrete M40 including all lifts, shuttering, drilling holes and fixing shear anchor as per specification, complete all as specified and as directed by Engr-in-Charge. Note:- Reinforcement shall be measured and paid separately. (Rates including jacketing, formwork and micro concrete)
9Material and Labour for ready mix polymer cement plaster with high quality polymer additives (Polymer plaster) with 4 MPa compressive strength of required thickness over the entire cleaned surfaces including all tools and tackles, etc. in damaged areas in 40 to 50 mm thickness including levelling profiling etc completeall as specified and as directed by Engr-in-Charge.
10Demolition ofcementconcrete of any type and in any position forbelowor above ground floors, complete all as specified and as directed by Engr-in-Charge.
11Material and Labour for PCC (1:3:6) type C-2 using 40mm graded aggregate, 75mm thick as in plinth protection/footpath, finished even & smooth using extra cement and including WPC by weight 3% of total cement content, complete all as specified and as directed by Engr-in-Charge.
12Material and Labour for PCC 1:2:4 type B-1 using 20mm graded stone aggregate as in coping, kneelers, apex, stones, bed plates, kerbs and likes including weathering, slightly rounded or chamfered angles and throating and including WPC by weight 3% of total cement content, complete all as specified and as directed by Engr-in-Charge.
13Material and Labour for applying two coats of synthetic enamel paint over a coat of red oxide, zinc chromate primer on new or previously untreated steel & iron surfaces of any description, not otherwise described, over 10cm width or girth including necessary preparation of surfaces, complete all as specified and as directed by Engr-in-Charge.
14Material and Labour for Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and as directed by Engr-in-Charge.Note:- Replacement of steel reinforcement with TMT bars of appropriate size where 30% of cross section is reduced including dismantling of rusted steel complete all as specified and directed.
15Ditto - all as per item No 14.00 here-in-before but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders including anchoring in existing concrete members, complete all as specified and as directed by Engr-in-Charge.
16Material and Labour for wire brushing, cleaning the surface from loose dirt, mortar dropping etc apply one coat of primer pure acrylic seater and allow to dry for 4-5 hrs. Thereafter, applying two coats of Anti-carbonation coating and allow to cure for 72 hrs. complete all as per manufacturer specificationsand as directed by Engr-in-Charge. Anti-carbonation coating to have the following properties:-(a) Vapour permeability - < 0.13 ASTM D1653(b) Diffusion resistance Co2: Min : 22.00g/(sqm d)(c) Diffusion air layer thickness : Min 11.00/m Din (d)53122 pt I adhesion min: 2.00 ASTM d-4541(e)Tensile strength Min 1.5 MPa(f)ASTM D 2370 , allow to cure for 72 hrs.
17Material and Labour for providing the following treatment to water reservoir complete all as per manufacturer specificationsand as directed by Engr-in-Charge :- (i) Wire brushing, cleaning the surfaces of walls , removingloose dirt, dust, gravel etc on external top and side wall surfaces. (ii) Fill all cracks, joints with Primer and filling the same with Polymeric joint sealant and allow to cure for 72 hrs.(iii) Apply one coat of Tank water proof coating and allow to cure to 24 hrs. (iv) Apply two coats of Anti-carbonation paint and allow to cure for 72 hours . Anti-carbonation coatingto have the following properties :- (a) Vapour permeability - < 0.13 ASTM D1653(b) Diffusion resistance Co2: Min : 22.00g/(sqm d)(c) Diffusion air layer thickness : Min 11.00/m Din (d)53122 pt I adhesion min: 2.00 ASTM D-4541(e)Tensile strength Min 1.5 MPa(f)ASTM D 2370 , allow to cure for 72 hours.
18Material and Labourfor fillingall visiblecracks joints in floor slab etc with Polymeric joint sealant by first priming with Primer. Thereafter, apply one bond coat of Epoxy Tac Coat prior to laying M-15 concrete in 30mm thickness laid to level to finish. Allow to moist cure for 7 days complete all as per manufacturer specifications and as specified and as directed by Engr-in-Charge.
19Material and Labour for applying on new concrete or plastered surfaces, one coat of tank waterproof coating, allow to cure for 72 hours. Thereafter, applying three coats of Epoxy Slurry mortar heavy duty tank coating at an interval of 4-6 hours between each coat complete all as per manufacturer specifications and as specified and as directed by Engr-in-Charge.
20Material and Labour for applying Epoxy Resin Based Concrete Bonding Agent for proper bonding between old surface with micro-concrete/new surface. The bonding agent shall be a two component solvent free epoxy supplied as ready to use at site, all as per manufacturer\"s specifications and as specified and as directed by Engr-in-Charge.
21Supply only water proofing liquid compound as URP complete all as specified and directed by Engr-in-Charge.
22Demolition of pre-cast concrete block walling in cement mortar including all quoins, arches, pillars etc. but excluding ashlar facings dressed stone work and pre cast concrete articles, complete all as specified and as directed by Engr-in-Charge.
23Material and Labour for pre-cast cement concrete block masonry with solid blocks, exc 10 cm in width in type B1 (1:2:4) 20mm thick graded aggregate and setting in mortar (1:6) , complete all as specified and as directed by Engr-in-Charge.
24Demolition of cement concrete in ground floor and paving not exceeding 15cm thickbelow or above ground level un-reinforced, complete all as specified and as directed by Engr-in-Charge.
25Material and Labour for PCC 1:4:8 type D2, using (40 mm graded agg) , 75mm thick asin sub base of flooring, complete all as specified and as directed by Engr-in-Charge.
26Material and Labour for PCC 1:2:4 type B2 using (40mm graded aggregate), 100mm thick as in flooring, ramp, surfaced even and fair without using extra cement complete with metallic floor hardener @3 % by weight of cement, all as specified and as directed by Engr-in-Charge.Note:- Metallic floor hardener shall be measured and paid separately.
27Supply only Metallic floor hardener, complete all as specified and as directed by Engr-in-Charge.
28Material and Labour for machine cut broken stone or boulders of gauge not exc 63mm as in hard core not exc 150mm thick spreadand levelled including watering & ramming , all as specified and as directed by Engr-in-Charge.
29Material and Labour for Chequered cement concrete tiles 30cm x 30cm x 25mm thick set jointed and pointed in neat cement slurry in floors or steps with in equal proportions & pigments with red and yellow colour over including 15mm thick screed bed in CM 1:6, complete all as specified and as directed by Engr-in-Charge.
30Material and Labour for 60 mm thick Machine pressed precast concrete interlocking paver blocks with grey cement and pigment, glazedcoloured up to 6mm on the top in any shape and size, strength not less than M-35 Grade, complete all as specified and as directed by Engr-in-Charge.
31Material and Labour for Sand filling under floors or in foundations including watering and consolidation all as specified and directed by Engr-in-Charge.
32Notes :-(a) Tenderer shall employ skilled manpower who has experience in the field. The tenderer shall furnish the following:-(i) Manufacturers test certificate with name of manufacturer and details of original product.(ii) Test certificates from any approved laboratory as directed by GE. The testing charges shall be borne by the tenderer.(b) Quoted rate shall be inclusive of all material, labours, tools and plants, scaffolding and working upto 10 metre height.(c) Adoption of necessary safety arrangement like safety belts, ropes, helmets, netting etc. which are required for safety of working at any height of the building shall be mandatory and deemed to be inclusive of quoted rates.

AI Tender Summary

OUR REF NO 48518650
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 24.25 Lakhs
LAST DATE 22-04-2025
Authority
Authority Name Military Engineer Services
Work Description Special Repairs To Bldg No P-904 At Ins Tunir At Naval Station Karanja
Basic Detail
Tender No 84428-K/E8
Bidding Type Tender
Location
City karanja
State Maharashtra
Key Dates
Publish Date 01 Apr 2025
Submission Date 22 Apr 2025
Open Date 24 Apr 2025
Finance
Tender Value 24.25 Lakhs
Tender Fee 500
EMD 49000
Exemption Not Available
Document List
e1b66d3d-0e96-4821-a2e4-f0e19dceffee.html
BOQ_787753.xls
SOC84428.pdf
Tendernotice_1.pdf
Tenderdocuments84428.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Apr 01, 2025
11:30 IST

Tender Published

Tender notice published.

Completed
Apr 22, 2025
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Apr 24, 2025

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

e1b66d3d-0e96-4821-a2e4-f0e19dceffee.html

xls

BOQ_787753.xls

pdf

SOC84428.pdf

pdf

Tendernotice_1.pdf

pdf

Tenderdocuments84428.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender