| 1 | Co-Treatment Facilities (STP (6.0 MLD) cum FSTP (16 KLD) |
| 2 | Design, Construction, Supply of all materials, Erection and Commissioning of co treatment facilities (6.0 MLD STP cum 16 KLD FSTP) with all the civil, electrical , mechanical, instrumentation and scada system, LT/HT panel, sub station building, DG set foundation, admin buidling, laboratories, meter room and campus development [Construction of Internal Road (CC Road, 3.5m wide, area approx 2000sqm.), staff quarters as per requirement and specification, external water supply (20KL tank including tube well and pumping arrangement, electrification & street llighting and sanitation work) etc. all complete for STP with co-treatment facilities. STP shall be based on SBR Technology OR any other proven technology. The effluent quality for agricultural uses (PH-6.5 TO 8.3, SS-30 mg/l, Oil&Grease-10 mg/l, BOD-10mg/l) , COD-30 mg/l , Residual chlorine-nil , TKN-10mg/l, Nitrate N-10 mg/l, F.C.-230 MPN/100 ml, Dissolved P-5 mg/l (preferable 2 mg/l). ) shall be maintained asper CPHEEO manuals. Latest NGT norms for effluent discharge shall be adhered. The cost of MPS(Peak flow 28.67 MLD) (civil works).(Civil Works) and 400mm dia class 1st and 2nd AC pipe with special & fittings for treated effluent are included in this estimate |
| 3 | Excavation below G.L. upto depth as specified for laying sewer and manhole ordinary soil (earth, sand, loam and clay) including cutting of joints pits ramming dressing) leveling, refilling of trenches in 20 cm layer watering and ramming the same including |
| 4 | (a)0.00 to 1.50 m |
| 5 | (b) 01.50 to 03.00 m |
| 6 | (c) 03.00 to 04.50 m |
| 7 | (d) 04.50 to 06.00 m |
| 8 | Provide and fix close timbering in trenches for the depth as specified below G.L. consisting of 40 mm thick approved country wood plank for polling board 125 x 75 mm eucalyptus-Safeda-Sal Wood wallers and 100 mm dia ballies for shuttering at 1.5 m C/C including all labour etc , complete |
| 9 | (a)1.50 to 3 m |
| 10 | (b) 03.00 to 06.00 m |
| 11 | Same as item No. 3 but for open timbering (No timbering for the depth < 1.5m) |
| 12 | (a) 1.5 to 03.00 m |
| 13 | Supply of following sizes of RCC spigotted and socketed non pressure pipes( Dia. In mm ) with structural strength as per IS 458 : 2003 and its latest amendment(s).NP3 |
| 14 | 200 mm dia |
| 15 | 250 mm dia |
| 16 | 300 mm dia |
| 17 | 350 mm dia |
| 18 | 400 mm dia |
| 19 | 450 mm dia |
| 20 | 500 mm dia |
| 21 | 600 mm dia |
| 22 | 700 mm dia |
| 23 | 900 mm dia |
| 24 | Carting following sizes of R.C.C. Hume pipe NP3 Class Socket / spigot rubber ring jointing and specials from store to the work lowering and laying the same in to the trenches upto depth as specified below G.L. true to alignment200 mm dia pipe |
| 25 | 00.00 - 0 1.50 m |
| 26 | 01.50 - 0 3.00 m |
| 27 | 250 mm dia pipe |
| 28 | 00.00 - 0 1.50 m |
| 29 | 01.50 - 0 3.00 m |
| 30 | 03.00 - 04.50 m |
| 31 | 04.50 - 06.00 m |
| 32 | 300 mm dia pipe |
| 33 | 03.00 - 04.50 m |
| 34 | 350 mm dia pipe |
| 35 | 00.00 - 0 1.50 m |
| 36 | 01.50 - 0 3.00 m |
| 37 | 03.00 - 04.50 m |
| 38 | 04.50 - 06.00 m |
| 39 | 400 mm dia pipe |
| 40 | 00.00 - 0 1.50 m |
| 41 | 01.50 - 0 3.00 m |
| 42 | 03.00 - 04.50 m |
| 43 | 04.50 - 06.00 m |
| 44 | 450 mm dia pipe |
| 45 | 01.50 - 0 3.00 m |
| 46 | 03.00 - 04.50 m |
| 47 | 500 mm dia pipe |
| 48 | 01.50 - 0 3.00 m |
| 49 | 03.00 - 04.50 m |
| 50 | 600 mm dia pipe |
| 51 | 01.50 - 0 3.00 m |
| 52 | 04.50 - 06.00 m |
| 53 | 700 mm dia pipe |
| 54 | 03.00 - 04.50 m |
| 55 | 04.50 - 06.00 m |
| 56 | 900 mm dia pipe |
| 57 | 00.00 -0 1.50 m |
| 58 | 03.00 - 04.50 m |
| 59 | 04.50 - 06.00 m |
| 60 | Cement concrete work in bedding below G.L. at specified depth with cement, coarse sand and 20 mm gauge approved stone ballast (1:2:4) including supply of all materials, labour, T&P etc. required for the proper completion of work. |
| 61 | (a) 00.00 to 01.50 m |
| 62 | (b) 01.50 to 03.00 m |
| 63 | (c) 03.00 to 04.50 m |
| 64 | (d) 04.50 to 06.00 m |
| 65 | Filling granular material (well graded crushed rock or gravel maximum size 20mm) into the trenches for class B bedding (granular bedding) including watering compaction, labour T&P etc. for completion of work. (As per statement) |
| 66 | (a) 00.00 to 01.50 m |
| 67 | (b) 01.50 to 03.00 m |
| 68 | Supply (excluding cartage) of granular material (well graded crushed rock or gravel of maximum size 20mm)for class B bedding (granular bedding) |
| 69 | Construction of circular type brick masonry HD (HD25) manhole (with Extra Heavy Duty type manhole cover) with top slab made of cement concrete 1:1.5:3 with graded granite stone aggregate (12 mm nominal size), wall made of brick masonry using 1st class bricks having crushing strength between 100 to 149 kg/cm² in cement mortar 1:4 inside plastering 12 mm thick 1:4 finished smooth with neat cement, pinning, outside plaster 1:4 and making channels with cement concrete 1:2:4 graded granite stone aggregate (12 mm nominal size) complete with including Plastic Encapsulated M.S. foot Rest staggered at 0.375 mtr interval, including excavation, reinforcement |
| 70 | 900mm internal dia., 1.65m deep |
| 71 | 1200mm internal dia., 3.30m deep |
| 72 | 1500mm internal dia., 4.95m deep |
| 73 | Extra for every additional depth of 1 m or part there of in following size of circular manholes. |
| 74 | 900mm internal dia., 1.65m deep |
| 75 | 1200mm internal dia., 3.30m deep |
| 76 | 1500mm internal dia., 4.95m deep |
| 77 | Dismantling/Cutting of the following type of road for laying sewers, manholes, sewer connection chambers etc.including shorting out and stacking serviceable materials and disposal of unserviceable materials as per direction of Engineer-incharge. |
| 78 | Bituminous road |
| 79 | Concrete road |
| 80 | Interlocking tile road |
| 81 | B.O.E road |
| 82 | Reinstatement of the following type of road for laying sewers, manholes, sewer connection chambers etc.including shorting out and stacking serviceable materials and disposal of unserviceable materialsas per direction of Engineer-incharge. |
| 83 | Bituminous road |
| 84 | Concrete road |
| 85 | Interlocking tile road |
| 86 | B.O.E road |
| 87 | Tack & SDBC Coat on existing BT Road (remaining area after reinstatement) |
| 88 | Supply of MS pipe (As per IS:3589 made from steel confirming to IS:2062), with anti corrosive treatment with P.U. coating |
| 89 | 900 mm dia pipe,10mm Pipe Wall Thickness |
| 90 | Installation of product pipe by HDD method including preparing and setting up the plants and equipement, preparing new pipe work material, installation new pipe-work and commissioning system or making the system ready for commissioning by HDD operation including,all related civil and mechanical works like excavation, shoring/strutting, etc. drilling, stringing, reaming, and pulling back the new pip-work on the designed bore path alignment, proper disposal of drilling fluid, and back fill of site after completion all inclusive as per IndSTT:101:2018: Code of prectice of HDD Technique Suiting Indian Conditions and as per direction of Engineer-incharge. |
| 91 | 900 mm dia pipe |
| 92 | Permission charges payable to the NHAI to taking permission for laying the pipe |
| 93 | Providing and erecting temporary barricading at site as per drawing/ direction of Engineer-in-Charge which includes hiring of Ballies and arrangement for traffic diversion such as traffic signals during construction at site as directed by the Engineer-in-Charge. The barricading provided shall be retained in position at site continuously i/c shifting of barricading from one location to another location as many times as required during the execution of the entire work till its completion. Rate include its maintenance for damages, painting, all incidentals, labour materials, equipments and works required to execute the job. The barricading shall not be removed without prior approval of Engineer-in-Charge. (Note :- One time payment shall be made for providing barricading from start of work till completion of work i/c shifting. The barricading provided shall remain to be the property of the contractor on completion of the work). The rate is for unit length of pipe laying. |
| 94 | Disposal of Surplus Earth as per direction of Engineer-incharge. |
| 95 | Construction of Boundary Wall 2.0 m ht. above plinth level and 0.23 m width with RCC Column @3m c/c with plinth beam and foundation avg. 1.2m depth including reinforcement and RCC coping on top of wall with plaster (1:4) and painting (apex painting 3 coat) as per type design and drawing at the STP site |
| 96 | MS gate (3.6m wide with 1.5m wicket gate with 0.35 x 0.35m RCC pillers) |
| 97 | Proposal for Supply of 1500 Ltr Capacity Sewer Suction Machine mounted on TATA 407 Gold/2900 WB Truck Chassis. |
| 98 | Interception and diversion (I&D) Structure works |
| 99 | I&D Structure with 1 no. S.S. gate across the Drain and1 no. S.S. gate at the diversion pipe inlet) |
| 100 | STP ( 6 MLD ) And Co Treat ment Plant ( 16 KLD )Design, Supply of all Materials, Erection, Testing,Commissioning and 3 month trial run Of Electrical, Mechanical & Instrumentation Equipments at STP (6 MLD )with all required electrical& mechanical works, PLC/SCADA work, electrification & street lighting work and Online Continuous Effluent Monitoring System (OCEMS) etc. all complete as per tender documentfor STP.The effluent quality for agricultural uses ( PH-6.5 TO 8.3,SS-30 mg/l, Oil & Greases -10mg/l, BOD- 10mg/l,COD-30 mg/l,Residual Chlorine-nil, TKN-10mg/l, Nitrate-10mg/l, FC-230MPN/100ml Dissolved P-5mg/l (preferable 2mg/l).) shall be maintained as per CPHEEO mannuals Latest NGT norms for effluent discharge shall be adhered. The rate is Considered for SBR Technology. The STP shall be capable to treat the raw sewage having minimum concentrationmentiond in CPHEEO mannual. Firm has to complete Design, Supply, Erection, Testing,Commissioning and 3 month trial run of Substation Work like HT Panel, Transformer & its associated equipments and DG Set Work with AMF Panelwith considering load of STP and MPS both.Design, Supply of all Materials, Erection and Commissioning and 3 month Trial Run of Co-Treatment Plant ( 16 KLD ) having manual screen with-SS 304 with bar size (50 mm x 10mm) and gaping 20 mm, Screw Pumps (3 Kl/h 1W+1S), Screw Press Machine (3KL/H), all type pipe and fittings, LT panel and cabling material,Dewatering Pumps (1W+ 1S), 5 HP Blower with 6 Nos Diffusers etc complete. including Supply and 3 month trial run.E&M WORK AT MPSElectrical WorksH.T.Panel( Comprising with 1 -I/C and 2 -O/G.SITC of Indoor Type Floor mounted HT Panel with11 KV, 630 Amps 3 phase, 50 Hz Vacuum Circuit Breaker (VCB) Panel Fabricated by System Integrator of VCB Manufacturer as per IEC 62271-1,100,200 Standard made from Powder painted pre-fabricated, CRCA sheet steel /High quality Aluminium-Zinc (Aluzinc) coated sheet steel. Fabrication shall be done through CNC turret press and CNC bending machine having a rupturing capacity of 500 MVA, 26.3 KA breaking capacity for 3 sec, Internal arc type tested for 26.3KA for 1 sec with AFLR clasification with suitable capacity of bus bar connected with the incoming and outgoing panels as per given details- |
| 101 | Supply installation testing and commissioning of Incoming Panel comprising of following: - VCB 630 Amps . VI of VCB should be sealed for 30000 operation. VCBoperationg mechanism should be of M2 duty for minimum 10000 mechanicaloperation. - Closing & tripping coil of VCB should be of continious rating to achive minimal failure. - Resin Cast type CT having Ratio : 400-200A/ 1-1 A, Core1: 5P20, 5 VA; Core 2: 0.5, 5 VA (How ever CT Ratio shall be decided as per load requirement)- VT Ratio: 11KV/1.732/110V/1.732/110V/1.732, -Core 1: 0.5, 20VA should be floor mounted and to be connected from the back side of the panel.- Numerical relay (should be VCB manufacturer\"s own make) having protections of 50,51, 50N,51N,TCS. The relay shall have programable 4 digital Input , programable 6 Digital Output and programable 4 nos. LED at HMI.- Ammeter with Selectorswitch and Volt meter with Selector switch- Multifunction Meter of Acc Class 0.5, having facility to monitor KW, KVA,KVAR, PF, KWH, KVARH, KVAH, A,V etc.- Trip circuit supervision relay (feature of numerical relay)- LR, TNC switch, indication lamp - CB ON/OFF, spring charge, Auto trip, TCS healthy etc., Space heaters - Power Pack (230V AC- 110V DC) and 8/12 window Annunciator. 1 SetSupply Installation Testing and Commissioning Outgoing Panel comprising of following: - VCB 630 Amps . VI of VCB should be sealed for 30000 operation. VCBoperationg mechanism should be of M2 duty for minimum 10000 mechanicaloperation. - Closing & tripping coil of VCB should be of continious rating to achive minimalfailure. |
| 102 | Resin Cast type CT having Ratio : 400-200A/ 1-1 A, Core1: 5P20, 5 VA; Core 2: 0.5, 5 VA (How ever CT Ratio shall be decided as per load requirement)- Numerical relay (should be VCB manufacturer\"s own make) having protectionsof 50,51, 50N,51N,TCS. The relay shall have programable 4 digital Input ,programable 6 Digital Output and programable 4 nos. LED at HMI.- Ammeter with Selectorswitch and Volt meter with Selector switch- Multifunction Meter of Acc Class 0.5, having facility to monitor KW, KVA,KVAR, PF, KWH, KVARH, KVAH, A,V etc.- Trip circuit supervision relay (feature of numerical relay)- LR, TNC switch, indication lamp - CB ON/OFF, spring charge, Auto trip, TCS healthy etc., Space heaters - Power Pack (230V AC- 110V DC)- 2 SetProviding & Laying XLPE insulated as per IS:7098/II/85 H.T.cable as per PWD specification for electrical Works for working voltage 11 K.V.(E) in existing RCC / Hume /Stoneware / PVC pipe/ open duct/cable trench, on existing cable trays or on surface etc. including making necessary connection, testing etc. 3 core X 120sq.mm. armored HT Cable (From HT Panel to Transformers)- 60 meterTrench making and covering of trench in all respect - 60 meterSITC of 11 KV End Termination Kit Indoor type (3 core, 120sq.mm)- 4 set11 KV, 2.5 mm thick with proof voltage 22 KV / 3 min. and Break Down Voltage 45 KV- 2.5 sqmTransformer (1w+1s) : Off -LTC (+5% to - 10% @ 2.5%) : S I T C of star rated Copper wound distribution Transformer of suitable capacity (designed as per load of stp & mps both) rating 11/0.433KV Delta-Star Connected, Vector Group Dyn 11,ONAN Cooled & losses as defined as per IS 1180 part I 2014. including standard accessories like conservator, silica gel breather, radiator, fins, HT cable box & LT cable boxes, temperature rise in winding/oil 35-40 degree C& 40-45 degree C for above 800 KVA, ISI marked drain valve, Dial type Temperature gauge, first filling of transformer oil as per IS :335-1953, Epoxy based paint, including carrying of pre-commission Testing & Charging of Transformer complete in all respect. (However actual capacity will be calculated at the time of execution , after approval of load list) - 2 Nos. |
| 103 | D.G. SET AND ACCESSORIES SITC of suitable capacity (should be designed according to MPS & STP Load both) Radiator Cooled and Turbo charged Silent type DG set , engine ,alternator capable of developingrequired power at 415+6%, 50 Hz AC at 0.85 P.F. lagging and self exciting coupled with suitable BHP diesel engine through flexible coupling and mounted on common base plate complete with fuel tank inside the acousting system and inbuilt control panel, Governor, Manual & electric Start , Batteries with battry charger, Engine instruments panel,AVM pads, All controls for operationof DG set are from outside the enclosure with DG control panel having Microprocessor based Genset monitoring like Running Hour, RPM, Low Lube Oil tripping & control system, Ammeter, Voltmeter, PF meter, frequency meter, KWH meter,digital fuel display meter, Ind.lamps etc. mounted inside enclosure , visible and accessiblefrom outside. T , 3 Met exhaust pipe, D.G. set shall be mounted under open sky resting on the foundation as per design. it sould complyCPCB 4(However actual capacity will be calculated at the time of execution, after approval of load list) -1 setSITC of PLC Based Auto main failure (AMF) Panel for DG Set fabricated from CRCA sheet steel 2 mm Thick , Powder coated finish , Engine Start & Stop commands, control Relays , Ammeter & Voltmeter with selector switches, Control & 2 nos 4 pole Power Contactors with 2 no. of required size 4 pole MCCB, Timers, Electronic Hooter ,Visual & Alarm indication for faults, operator interface panel complete in all respect. ( pwd bsr 2022- 23.29.3)- 1 set Pipe Earthing as per IS:3043- 1987 with 3.0 Mtr. Long, 40 mm dia. \" B \" class G.I. Pipe IS: 1239 (Part-1) 2004, Equivalent to BS : 1387 withperforated holes of 12 mm dia ,including all accessories like nut, bolts,reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, BottomDia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required.( pwd bsr 2022- 14.1) - 2 Job Plate Earthing as per IS:3043 with copper Earth plate of purity >95% of size 600mm x 600mm x 3.0mm by embodying 3 mtr. below the ground level with 20 mm dia. G.I. \"B\" class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/charcoal, testing of earth resistance for value of 5 ohms or less as required.( pwd bsr 2022- 14.3) -2 Job |
| 104 | Supply & Laying 50 mm X 6mm sizeGI earth strip in horizontal or vertical run in surface by means of Earth strip DMC Insulator including riveting/soldering/ welding, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required. - 40 MetProviding and Laying cable for DG Set to Panel 185 sq mm X 3.5 core x 2 run( armored aluminium ). -50 MetSupplying and making one end termination with heavy duty brass compression gland (as per IS 12943- 1990) SIBG type, heavy duty aluminium lugs (as per IS 8309 - 1993 & IS 8337-1976 ) duly crimped with crimping tool, PVC tape as per PWD specification for electrical Works etc for following size of Armoured PVC insulated & PVC sheathed/ XLPE aluminium conductor cable of 1100 volt grade for 3.5 core X 185 sq mm.(pwd bsr-2022-item no 12.1.24)- 4 Job |
| 105 | L.T. PanelSITC of 0.415 kV L.T. control panel for pumping plant-L.T. control panel suitable to operatedon 415 ± 6 %volt , 3 Phase , 50 Hz, AC supply as per details given below-(A) 2 Nos incoming ACB panels and 1 outgoing ACB panel, each consisting of following items -(i) 4 pole Microprocessor based release Draw out type ACB (Motorised charging type) ,630 A Rating ,50 kA- 1 No.(ii)C.Ts of suitable ratio- 1 No.(iii)Ammeter with selector switch - 1 No.(iv) Voltmeter with selector switch- 1 No. (v)Power factor meter(0.5 Lag&0.5Lead) - 1 No.(vi)Frequency meter-1 No.(vii)KWH meter - 1 No. (viii)2 Pole over current relay& one pole earth fault relay - 1 No.(B)Bus bar chamber having 3 Nos. bus bars for phase and 1 No. bus bar for neutral of suitable size – 1 No. (C) 6 Nos. composite panels for pumping plants, each consisting of following items –(i) 4 pole MCCB 160 A current rating, 50 KA short circuit breaking capacity With Microprocessor based release with adjustableadjustable O/L & S/C setting with Inbuilt Instantaneous and Ground fault Protection -1 No.(ii)C.Ts. of suitable ratio- 1 No.(iii)Ammeter with selector switch - 1 No.(iv) Automatic start / stop device according to level in the sump- 1 No.(v)Indicating lamps(Auto/manual/low level/ reverse rotation) - 1 Set (D) 3 Nos. outgoing panels for miscellaneousworks, each consisting of following items – (i) MCB of 40 A capacity- 1 No.(ii) C.Ts. of suitable ratio- 1 No. (iii) Ammeter with selector switch - 1 No.(iv) Indicating lamps- 1 Set (E)APFC Panel for total load.(F) 4 pole Microprocessor based release Draw out type (Motorised charging type) ,630 A Rating ,50 kA Panel for DG sets incoming - 1 NO (G) Bus coupler arrangement in panels |
| 106 | LT Cable laying and jointingPower and control cable-Supply of 185 sq. mm 3.5 core cable - 2 Run required for power fromeach Transformer to each L.T. panel , 50 sq. mm X3 core-1 run cable for power from starters to Motor including lugging and jointing, laying, trench excavation and compaction as well as complete cabling of automation systemetc. complete in all respect. |
| 107 | EarthingPlate Earthing as per IS:3043 with copper Earth plate of purity >95% ofsize 600mm x 600mm x 3.0mm by embodying 3 mtr. below the groundlevel with 20 mm dia. G.I. \"B\" class watering Pipe ,including all accessorieslike nut, bolts, reducer, nipple, wire meshed funnel, and Heavy dutyweather proof poly-propylene earth pit chamber with lockable Jam freelid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. andembodying the pipe complete with alternate layers salt and coke/charcoal, testing of earth resistance for value of 5 ohms or less asrequired & must record by engineer in charge during site visit and ensureto enter in measurment book. All as per pre approved by Engineer incharge. |
| 108 | Pipe Earthing as per IS:3043- 1987 with 3.0 Mtr. Long, 40 mm dia. \" B \"class G.I. Pipe IS: 1239 (Part-1) 2004, Equivalent to BS : 1387 withperforated holes of 12 mm dia ,including all accessories like nut, bolts,reducer, nipple, wire meshed funnel, and Heavy duty weather proof polypropylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, BottomDia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipecomplete with alternate layers salt and coke/ charcoal, testing of earthresistance for value of 5 ohms or less as required & must record byengineer in charge during site visit and ensure to enter in measurmentbook.All as per pre approved by Engineer in charge. |
| 109 | Supply & Laying of 50mmX6mm size GI earth strip in horizontal or vertical run in ground/surface/recess including riveting,soldering, saddles, Jointing shall be done by overlapping and with 2 set of GI nut bolt & spring washer spaced at 50cm making connection etc.(20meter for each earthing) |
| 110 | Charges of Electrical safety Clearance |
| 111 | Expenditure on B&L Form, Challan etc. |
| 112 | Proper fencing of substation portion as per I.E. rules. (Ref. Ongoing AMRUT Work Aligarh Sewarage) |
| 113 | STARTER PANEL |
| 114 | SITC of Compraising of Soft Starter, suitable to meet the basic requirement of motor protections and suitable to run 15 KW motor (To be fixed in composite panel of LT Panel)- |
| 115 | Mechanical WorksPumpThesubmersible non clog pumpset should be single stage having two vanes enclosedimpellercoupled with submersible motor of 20 HP Rating 400 Volt ±10%,3 phase 50 Hz, solid handling capacity 125mm, suitable to pump raw sewage with an specific gravity 1.03 having following construction of material with 10 Met. cable as offered. (4W+2S)Casing-2% Ni Cl. IS.210 grade F.G.220 with hardness 275 BHN.Impeller-Stainless steel CF-8Mshaft-stainless steel AISI-410Discharge of pump= 2610 lpmTotal Head= 18 MSpeed=980Quantity of pumps. 06 nos.Guid Rail SystemGuide rail system (Automatic coupling system) for 20 HP submersible pump setscomplete for above pump set. 06 setsLifting Chain , MOC- alloy steel, lifting chain with oval ring @ 1m & with D/Bow shackle - 06 sets |
| 116 | Quantity of pums |
| 117 | Main piping and Valves.Main piping and valves 200 mm dia delivery, 400 mm diacommon header line.Valves.Confirming to IS 780/2906 or as applicable PN rating- 1.0Type of liquid to be handled-potable waterMaterial of constructionBody-CI,IS-210 grade FG 200Wedge-CI IS210 Grade FG200Spindle-Stainless steel AISI304Sheet and face Ring-SS ASTMA 743 Grade C.F.8 MChannel& Shoe-S.S.AISI,.304Drain& Air plug-S.S.AISI.304Bushing arrangement-Halprene on bronzeRivets-AISI:304Fasteners-MSMotor Operated Sluice Valves |
| 118 | Moter operated Sluice Valve 200 mm dia |
| 119 | Moter operated Sluice Valve 400 mm dia |
| 120 | Reflux valve 200 mm dia N.B. |
| 121 | PIPINGNote : Regarding the size of pipes, Tee, Bend etc, contrctor is required to designed them self and may got it approved by the department before execution of works along with layout drawing taking 200mm pipe 60m and 350 mm pipe 15m . |
| 122 | 200 mm, K9 delivery pipes for all six pumping plant |
| 123 | 400 mm, K9 common header pipes |
| 124 | Specials like bend, tee, D Joint etc.@ of 5% |
| 125 | Nut Bolt, Washer Rubber packing etc @ of 5% |
| 126 | Installation & Commissioning of all 6 Nos. Pump set,Piping & Valves as mentioned in above @10% of supplied items. |
| 127 | Level Transmitter (For Hi-Lo cut-off & alarms)SITC of Radar type level transmitter shall be provided in the pump house for measuring the sewage level in wet sump. The indicator shall be digital type showing depth in meters and shall be capable for input to PLC or HMI touch sceen for display. |
| 128 | Electro magnetic flow meterSITC of CE/UL certified Electro magnetic flow metersuitable to measure 0 to 30 MLD flow to be fitted in 350 mm dia main header line. |
| 129 | E.O.T. CraneSITC of 3 Tonn E.O.T. crane providing, erecting and commissioning single girder electrically operated rectangular over head travelling crane with 6 m lift complete with wire rope hoist, class II duty, all three motions electrically operated by suitable rating m |
| 130 | Chequerred plate and guardsSITC of 3mm thick M.S chequerred plate over all the run of cables trenches to cover properly and M.S. grill and M.S. guard over all pipes ducts and other point where required as per site condition(3X0.75+3X0.9+7X0.6+1X0.9)X1=10.05sqmm. |
| 131 | PAINTINGPainting of all pumps piping and valves with two coat enamel paint. |
| 132 | LIGHT WIRING & Electrification (Ref. UP Jal Nigam E&M SOR, 2019) |
| 133 | Complete Internal Electrification of LT Panel room with 2 Nos. Exhaust Fan |
| 134 | Complete Internal Electrification of HT Panel room with 2 Nos. Exhaust Fan |
| 135 | IPS Campus with Solar Panel and LED Light of 3 sets. |
| 136 | SCREENS AND GATES: |
| 137 | Rising type thimble mounted CI Sluice Gates of reputed make at IPS |
| 138 | Stainless Steel Manual Screen (20 mm gaping) with bar size 50 mm x 10 mm and 1 no pungi for both manual screens (1working+ 1standby) |
| 139 | Packing and Frieght @ 3% of ( 25 & 26 ) |
| 140 | Installation, Testing and Commissioning @ 10% of (25&26) |
| 141 | AUTOMATION OF MPSCE& UL certified PLC/RTU with redundant CPU & power supply in IP 54 enclosure suitable to communicate with GSM based modem unit with redundant CPU & power supply with annalog & digital paramter & features as specified for each ZPS/OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations as specified in tender technical specification including full developed version of scada software with customization of software with laptop/desktop etc to monitor and control the ips from remote places. |
| 142 | GSM/GPRS based wireless communication with 4G modem for RTU/PLC capable to transfer & gather data from remote sites to control stations all accessories included with signal enhancer antenna made for pumping plant internet charges as specified in tender technical specification. |
| 143 | CE/UL certified intellignet Smart Energy Meter |
| 144 | Auto phase reversal unit with inbuilt time delay & enclosure (confirm to IEC-60947-1 & IEC-60947-b-1)160 AMP rating |
| 145 | Electronic sensor type pressure measuring device suitable for pressure measurements of sewage flow in delivery and common header line. The material of construction of housing and other parts in contact with sewage shall be of stainless steel. These shall be of required protection category and complete with signal transmitting device and digital pressure indicator. |
| 146 | CE/UL Certified Surge protector for control panel. |
| 147 | CE/UL Certified 7\" HMI touch screen suitable to communication with PLC/RTU for local display & control ofp rocess parameters. |
| 148 | Security Survillance IP Camera with recorder |
| 149 | Installation, commissiong & testing of above automation work |
| 150 | Trial run of automation work for 3 month period for MPS |
| 151 | Three month Expenditure on Operator (MPS) in 3 Shift |
| 152 | Diesel Consumption During Trial and Run Period (MPS & STP both) |
| 153 | Electricity consumption during period of Trail and Run period, payment will bedone as UPPCL Bill for MPS and STP both |