| 1 | Dismantling the existing pole up to 6 m height withbrackets, clamps, insulators, stay from the cement concrete foundation and making the site clear by refilling the pitswith excavated materials and bringing it to the ground level. |
| 2 | Dismantling the existing pole above 6 m height withbrackets, clamps, insulators, stay from the cement concrete foundation and making the site clear by refilling the pits with excavated materials and bringing it to the ground level. |
| 3 | Supplying and erecting steel tubular swaged pole 139.7 x 114.3 x 88.9 mm. dia with 4.5x3.65x3.25 mm thickness (4.5 + 1.75 + 1.75 m) length respectively and total 8 m long with pole cap, base plate in provided foundation.(weight 101 kg.) as per specification no. OH-PL/STP |
| 4 | Making cement concrete foundation including excavation (60 x 60 x 150) cm deep in 1:3:6 cement concrete 20 x 25 mm stone metal, (45 x 45 x 45) cm /45 cm dia. x 45 cm height plinth duly plastered, with necessary curing and finishing complete. (above 6 m to 9 m poles) |
| 5 | Providing pipe type earthing with 40mm. dia. G.l. pipe or 20 mm dia. G.l. Rod complete with all materials as per specification no. EA-EP |
| 6 | Supplying \"C\" or ‘D’ type pole clamps, fabricated from 50 x 6 mm MS flat with 15 mm dia. bolts and nut fixed to steel tubular pole duly painted with one coat of red oxide and two coats of aluminium paint |
| 7 | Supplyingpole clamp made from 50 x 6 mm MS flat for pole or pipe, post complete erected with 15 mm bolts and nuts, complete duly painted with one coat of red oxide and two coats of aluminium paint. |
| 8 | SupplyingFRP box of size 300 x 200 x 125 mm, 2.7 mm thick complete on pole/wall as per specification no. CB-SB |
| 9 | Supplying, marking SPMCB 6A to 32A, B- series (for lighting) in provided distribution board as perspecification no. SW-SWR/MCB |
| 10 | SupplyingStreet light bracket for erection of side entry fitting on pole with 40 mm. dia. ‘B’ grade G.I. pipe of required length complete as per specification no. FG BKT/SLB |
| 11 | SupplyingLED Street light fitting suitable for above 40W to 48W lamp, including lamp, with PF > 0.95 class IP 65 and above housing of pressure die cast aluminium alloy and heat sink extruded aluminium complete perspecification No . FG-ODF/FLS2. |
| 12 | Supplying LED street light fitting suitable for above75W - 90W lamp, including lamp, with PF > 0.95 class IP 65 and above housing of pressure die cast aluminium alloy and heat sink extruded aluminium complete per specification No. FG-ODF/FLS2. |
| 13 | Supplying LED street light fitting 120 W, including lamp, with PF > 0.95 class IP 65 and above housing of pressure die cast aluminium alloy and heat sink extruded aluminium complete per specification No FG-ODF/FLS-2. |
| 14 | SupplyingLED street light fitting 150 W, including lamp, with PF > 0.95 class IP 65 and above housing of pressure die cast aluminium alloy and heat sink extruded aluminium complete per specification No FG-ODF/FLS-2. |
| 15 | SupplyingPVC insulated PVC round sheathed 1.5 sq.mm (30 no. x 0.25 mm dia.) 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 kV |
| 16 | SupplyingPVC insulated PVC round sheathed 2.5 sq.mm (50 no. x 0.25 mm dia.) 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 kV |
| 17 | Supplying PVC insulated PVC round sheathed 4 sq.mm (56 no. x 0.30 mm dia.) 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 kV |
| 18 | Supplying pin type LT medium insulator 100 mm x 62 mm dia. with suitable G.I. spindle, nut, bolts complete erected. |
| 19 | Supplying and laying (including excavation of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete. |
| 20 | Supplying and laying (including excavation of suitable width & depth up to 90 cm) 75 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete. |
| 21 | Supplying XLPE armoured cable 4 core 10 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 22 | Supplying XPLE armoured cable 4 core 16 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 23 | Supplyingmains with ISI mark WP 2 x 4 sq. mm.1100 V grade aluminium PVC insulated and PVC sheathed wires on G.I. bearer wire No. 8 SWG complete erected with required size of porcelain reel insulators and 16 SWG G.I. binding wire. |
| 24 | Supplying and erecting mains with ISI mark WP 2 x 6 sq. mm.1100 V. grade aluminium PVC insulated and PVC sheathedwires on G.I. bearer wire No. 8 SWG complete erected with required size of porcelain reel insulators and 16 SWG G.I. binding wire. |
| 25 | Supplying marking DPMCB 6 A to 32 A B- series (for lighting) in provided distribution board as per specification no. SW-SWR/MCB |
| 26 | Supplying marking FPMCB 6A to 32A in provided distribution board as per specification no. SW-SWR/MCB |
| 27 | Supplying, erecting & marking FPMCB 40A to 63A inprovided distribution board as per specification no. SW SWR/MCB |
| 28 | Supplying & marking DPMCB 40A to 63A, C series (for motor/power) in provided distribution board as per specification no. SW-SWR/MCB |
| 29 | Dismantling the existing overhead line including G.I. wires of all sizes without damaging & making the coils in suitable sizes |
| 30 | Erectingprovided steel tubular swagad pole of8.5 mtr. Length. |
| 31 | SupplyingLED Flood light fitting of 90-100W, including lamp, with PF > 0.95, class IP 65 and above housing of pressure die cast aluminium alloy and heat sink extruded aluminium complete per specification No FG ODF/FLS-2 |
| 32 | SupplyingLED Flood light fitting of 150W,including lamp, with PF > 0.95,class IP 65 and above Housing of pressure die cast aluminium alloy and heat sink extruded aluminium complete per specification No FG ODF/FLS-2 |
| 33 | SupplyingStreet light bracket made from 40 mm. dia ‘B’ class G.I. Pipe, 0.6m. in length along with pole cap of 300 mm length and 80 mm dia duly welded withprovided leads as per specification no. FG-BKT/BPC |
| 34 | Supplyingelectronic type Driver for Outdoor LED fittings upto 46W-75W suitable to operate on 230V A.C. 50 Hz. having pf>0.95 and THD |
| 35 | Supplyingelectronic type Driver for Outdoor LED fittings upto 76W-100W suitable to operate on 230V A.C. 50 Hz. having pf>0.95 and THD<10%. |
| 36 | Repairing LED street fitting upto90 Watt (including strip) |
| 37 | Repairing LED street fitting upto100-Watt- 150 Watt (including strip) |
| 38 | Supplying and erecting street light Wall bracket made from 40 mm. dia ‘B’ class G.I. pipe 1.2 m in total length complete as per specification no. FG-BKT/WB |
| 39 | Dismantling the existing W.T. fluorescent fitting/ S.V./ M.V. / M.H. lamp /LED fitting from pole with brackets complete. |
| 40 | Supplyingstreet light control panel in powder coated CRCA 14/16 SWG sheet, outdoor type, single phase, 240 V consisted of suitable rating contactor, 24 hrs digital / astronomical time switch with minimum 5 years battery backup, SPN MCB 40 A, auto/manual selector switch, ON/OFF push buttons, indicator lamps, control wiring, metering device, etc for automatic operation & overcurrent, short circuit, earth fault protection of street lights upto the maximum load of 6 kW on provided iron frame/ CC foundation complete. |
| 41 | Supplying street light control panel in powder coated CRCA 14/16 SWG sheet, outdoor type, three phase, 415V consisted of suitable rating contactor, 24 hrs digital/ astronomical time switch with minimum 5 years battery backup, TPN MCB 63 A auto/manual selector switch, ON/OFF push buttons, indicator lamps, control wiring, metering device, etc for automatic operation & overcurrent, short circuit, earth fault protection of street lights upto the max load of 12 kW on provided iron frame / CC foundation complete. |
| 42 | Supplyingstreet light control panel in powder coated CRCA 14/16 SWG sheet, outdoor type, three phase, 415 V consisted of suitable rating contactor, 24 hrs digital / astronomical time switch with minimum 5 years battery backup, TPN MCB 40 A auto/manual selector switch, ON/OFF push buttons, indicator lamps, control wiring, metering device, etc for automatic operation & overcurrent, short circuit, earth fault protection of street lights upto the max load of 6 kW on provided iron frame / CC foundation complete. |
| 43 | Painting of pipe pole upto 6 m length along with street light / pole brackets / clamps etc by scrapping the existing paint complete. Specification no CW -PTG/PTP(existing old poles). |
| 44 | Supplying and erecting Street light bracket for erection of Double fitting made from 40 mm. dia ‘B’ class G.I. pipe 1.0 m in length along with pole cap of 300 mm length 100 mm dia duly welded as per specification no. FG-BKT/BPC |
| 45 | Painting of steel tubular / rail / RSJ pole above 6.0 m length along with street light pole brackets, clamps etc by scrapping the existing paint complete. Specification no CW -PTG/PTP (existing old poles). |
| 46 | Providing one vehiclefitted with adjustable hydraulic ladder (ladder height minimum 111 mtr )along with driver, diesel / petrol for vehicle for maintenance of street light or other transmission work in the Savitribai Phule Pune University. |
| 47 | Providing one skilled electrician / wireman for electrical street light work |
| 48 | Providing one un-skilled labour for electrical street light work |
| 49 | Supplying and erecting street light Wall bracket made from 25 mm. dia ‘ G.I. pipe 1.2 m. in total length complete as per specification no. FG-BKT/WB |
| 50 | Supplying and erecting Street light bracket for erection of Single fitting made from 40 mm. dia ‘B’ class G.I. pipe 1.0 m. in length along with pole cap of 300 mm length 100 mm dia duly welded as per specification no. FG-BKT/BPC |
| 51 | Supplying & erecting water tight terminal box of cast iron of size 300 x 200 x 150 mm complete on pole as per specification No. CB-SB |
| 52 | Supplying & erecting FRP box of size 150mm x 125 mm x 100 mm, 2.7 mm thick complete on pole/wall as per specification No. CB-SB |
| 53 | Supplying & erecting crimping type aluminium lugs for cable up to 16 sq mm complete as per specification No. CB-CL/AL |
| 54 | Supplying & Erecting LED 90/100 Watt heritage type street light fitting with specification as: colour temperature 3000 to 4500 K, IP65 Protection, -20 to +42 degree celcius operating temperature, housing of spin alluminium with corrosive resistant powder coated with polden colour material, optic lens for uniform light distribution, CRI>70, operating voltage 140 to 270 Volt AC, lumens>11000, polycarbonate diffuser, inbuilt electronic driver, light colour - warm white. |
| 55 | Supplying & Erecting LED 40/50 Watt heritage type street light fitting with specification as: colour temperature 3000 to 4500 K, IP65 Protection, -20 to +42 degree celcius operating temperature, housing of spin alluminium with corrosive resistant powder coated with polden colour material, optic lens for uniform light distribution, CRI>70, operating voltage 140 to 270 Volt AC, lumens>11000, polycarbonate diffuser, inbuilt electronic driver, light colour - warm white. |
| 56 | Providing & erecting 7 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130mm A/F, top 70 mm A/F on provided foundation as per specification no.OH-PL/OPL. |
| 57 | Providing & erecting 6 m high (clear height) galvanisedoctagonal pole with foundation bolts having bottom of 130mm A/F, top 70 mm A/F on provided foundation as per specification no. OH-PL/OPL |
| 58 | Providing & erecting 8 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 135mm A/F, top 70 mm A/F on provided foundation as per specification no. OH-PL/OPL |
| 59 | Making M- 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity atsite as 10 T/sq.m at 1.5 m depth including supply of steel,concrete, excavation and fixing provided nut bolts with thehelp of template, duly plastered as per design complete (for6m to 8m high octagonal /conical GI pole). |
| 60 | Supplying and erecting LED Flood light fitting of 200W, including lamp, with PF > 0.95,class IP 65 and above Housing of pressure die cast aluminium alloy and heat sinkextruded aluminium complete per specification No FG ODF/FLS-2 |
| 61 | Supplying and erecting metal work in CRCA sheet with fabrication of boxes, panel boards, etc. including cutting, bending, drilling, welding, riveting, treated with anti-rusttreatment and duly powder coated or painted with one coat ofred lead paint and 2 coats of enamel paint complete. |