}

Bids Are Invited For Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Rr Site Unit 3 And 4; Rewinding Of Three Phase 415 V 50Hz Motors Of Less Than 1 Point 1Kw Rating As Per Part A Scope Of Work Total Quantity 1 Is Equa, Chittorgarh-Rajasthan

Nuclear Power Corporation Of India Limited has published Bids Are Invited For Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Rr Site Unit 3 And 4; Rewinding Of Three Phase 415 V 50Hz Motors Of Less Than 1 Point 1Kw Rating As Per Part A Scope Of Work Total Quantity 1 Is Equa. Submission Date for this Tender is 02-05-2025. Mechanical engineering Service Tenders in Chittorgarh Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

48481005
Corrigendum : Bids Are Invited For Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Rr Site Unit 3 And 4; Rewinding Of Three Phase 415 V 50Hz Motors Of Less Than 1 Point 1Kw Rating As Per Part A Scope Of Work Total Quantity 1 Is Equa
Open Tender
Indian
Rajasthan
Chittorgarh
02-05-2025

Tender Details

Bids Are Invited For Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Rewinding of Three phase 415 V 50Hz motors of less than 1 point 1kW rating as per Part A Scope of work Total quantity 1 is equal to 12 Nos fo.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Rewinding of Three phase 415 V 50Hz motors of more than 1 point 1 kW up to 2 point 2 kW rating as per Part A scope of work Total quantity 1.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Rewinding of Three phase 415 V 50Hz motors of more than 2 point 2 kW up to 5 point 5 kW rating as per Part A scope of work Total quantity .. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Rewinding of Three phase 415 V 50Hz motors of more than 5 point 5 kW up to 11 kW rating as per Part A scope of work Total quantity 1 is e.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Rewinding of Three phase 415 V 50Hz motors of more than 11 kW up to 22 kW rating as per Part A scope of work Total quantity 1 is equal to.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Rewinding of Three phase 415 V 50Hz motors of more than 22 kW up to 55 kW rating as per Part A scope of work Total quantity 1 is equal t.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Rewinding of Three phase 415 V 50Hz motors of more than 55 kW up to 75 kW rating as per Part A scope of work Total quantity 1 is equal to.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Rewinding of Three phase 415 V 50Hz motors of more than to 90 kW rating as per Part A scope of work Total quantity 1 is equal t.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Rewinding of Three phase 415 V 50Hz motors of more than 90 kW up to 110 kW rating as per Part A scope of work Total quantity 1 is equal to.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Rewinding of Three phase 415 V 50Hz motors of more than 110 kW up to 132 kW rating as per Part A scope of work Total quantity 1 is equal .. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Rewinding of Three phase 415 V 50Hz motors of more than 132 kW up to 140 kW rating as per Part A scope of work Total quantity 1 is equal t.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Rewinding of Three phase 415 V 50Hz motors of more than 140 kW up to 180 kW rating as per Part A scope of work Total quantity 1 is equal t.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Rewinding of Three phase 415 V 50Hz Submersible pump motors up to 2 point 5 kW rating as per Part A scope of work Total quantity 1 is equal.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Rewinding of Three phase 415 V 50Hz Submersible pump motors more than 2 point 5 kW up to 5 point 5 kW rating as per Part A scope of work T.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Rewinding of Three phase 415 V 50Hz Submersible pump motors more than 5 point 5 kW up to 11 kW rating as per Part A scope of work Total qua.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Rewinding of Three phase 415 V 50Hz Submersible pump motors more than 11 kW up to 15 kW rating as per Part A scope of work Total quantity 1.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Rewinding of Three phase 415 V 50Hz Submersible pump motors more than 15 kW up to 37 kW rating as per Part A scope of work Total quantity .. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Rewinding of Single phase 230 V 50Hz motors of Ceiling fan 1200 mm sweep as per Part A Scope of work Total quantity 1 is equal to 75 Nos .. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Rewinding of Single phase 230 V 50Hz motors of Pedestal fan or wall mounted fan or Exhaust fan up to 450 mm sweep as per Part A Scope of work.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Rewinding of Single phase 230 V 50Hz motors of Exhaust fan or cooler fan above 400 mm sweep as per Part A Scope of work Total quantity 1 is eq.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Rewinding of Self starter motor 24V DC Type 10TH 232 C suitable for greave diesel engine Model 64DX Mark II as per Part A Scope of work Total quan.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Rewinding of 2000 VA Control Transformer as per Part A Scope of work Total quantity 1 is equal to 02 Nos for two years; Service Provider , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version Part A Scope of work Total quantity 1 is equal to 02 Nos for two years; Service Provider , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Rewinding of 500 VA Control Transformer as per Part A Scope of work Total quantity 1 is equal to 02 Nos for two years; Service Provider , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Rewinding of control coil 415V Diameter up to 300MM including bobbin as per Part A Scope of work Total quantity 1 is equal to 02 Nos for two ye.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Rewinding of Single phase 230 V 50Hz Submersible pump motors up to 1 point 5 kW rating as per Part A scope of work Total quantity 1 is equa.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Supply and installation of Shaft for Ceiling fan or pedestal fans as per Part A scope of work Total quantity 1 is equal to 25 Nos for two years; Se.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Supply and installation of Gun metal bushes as per Part A scope of work Total quantity 1 is equal to 25 Nos for two years; Service Provider , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Repair of hot spot in Three phase 415 V 50Hz motors up to 1 point 5 kW rating as per Part B scope of work Total quantity 1 is equal to 02 No.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Repair of hot spot in Three phase 415 V 50Hz motors of more than 1 point 5 kW up to 7 point 5 kW rating as per Part B scope of work To.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Repair of hot spot in Three phase 415 V 50Hz motors of more than 7 point 5 kW up to 22 kW rating as per Part B scope of work Total quan.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Repair of hot spot in Three phase 415 V 50Hz motors of more than 22 kW up to 45 kW rating as per Part B scope of work Total quantity 1 i.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Repair of hot spot in Three phase 415 V 50Hz motors of more than 45 kW up to 90 kW rating as per Part B scope of work Total quantity 1.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Repair of hot spot in Three phase 415 V 50Hz motors of more than 90 kW up to 180kW rating as per Part B scope of work Total quantity 1 i.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Removal of hot spot by dismantling of total stampings in Three phase 415 V 50Hz motors up to 22 kW rating as per Part B scope of work Tot.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Removal of hot spot by dismantling of total stampings in Three phase 415 V 50Hz motors of more than 22 kW up to 45 kW rating as per Part.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Removal of hot spot by dismantling of total stampings in Three phase 415 V 50Hz motors of more than 45 kW up to 90 kW rating as per Part.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version and 4; Removal of hot spot by dismantling of total stampings in Three phase 415 V 50Hz motors of more than 90 kW up to 180 kW rating as per Par.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Re metalizing of shaft using TAFA arc technique after preparation of surface and machining to proper size up to 1 point 5 kW motor as per Part B sc.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Re metalizing of shaft using TAFA arc technique after preparation of surface and machining to proper size more than 1 point 5kW up to 7 point 5 kW.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Re metalizing of shaft using TAFA arc technique after preparation of surface and machining to proper size more than 7 point 5 kW up to 15kW motor a.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Re metalizing of shaft using TAFA arc technique after preparation of surface and machining to proper size more than 15 up to 45 kW motor as per Par.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Re metalizing of shaft using TAFA arc technique after preparation of surface and machining to proper size more than 45kW up to 90 kW motor as per P.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Re metalizing of shaft using TAFA arc technique after preparation of surface and machining to proper size more than 90kW to 180kW motor as per Part.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Re metalizing of end covers using TAFA arc technique after preparation of surface and machining to proper size up to 1 point 5 kW motor as per Part.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Re metalizing of end covers using TAFA arc technique after preparation of surface and machining to proper size more than 1 point 5 kW up to 7 poin.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Re metalizing of end covers using TAFA arc technique after preparation of surface and machining to proper size more than 7 point 5 kW to 15kW motor.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Re metalizing of end covers using TAFA arc technique after preparation of surface and machining to proper size more than 15 kW up to 45 kW motor as.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Re metalizing of end covers using TAFA arc technique after preparation of surface and machining to proper size more than 45kW up to 90 kW motor as .. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Re metalizing of end covers using TAFA arc technique after preparation of surface and machining to proper size more than 90 kW to 180kW motor as pe.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Replacement of PVC cooling fan for motors size up to 1 point 5 kW as per Part B scope of work Total quantity 1 is equal to 8 Nos for two years; Se.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Replacement of PVC cooling fan for motors size more than point 5kW up to 7 point 5 kW as per Part B scope of work Total quantity 1 is equal to 8.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Replacement of PVC cooling fan for motors size more than 7 point 5kW upto 15kW as per Part B scope of work Total quantity 1 is equal to 8 Nos for .. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Replacement of PVC cooling fan for motors size more than 15kW up to 45kW as per Part B scope of work Total quantity 1 is equal to 8 Nos for two ye.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Dynamic balancing of rotor with 2 point 5microns accuracy size more than 1kg up to 4 kg as per Part B scope of work Total quantity 1 is equal to 2.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Dynamic balancing of rotor with 2 point 5microns accuracy size more than 4 kg up to 16 kg as per Part B scope of work Total quantity 1 is equal to.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Dynamic balancing of rotor with 2 point 5microns accuracy size more than 16 kg up to 48 kg as per Part B scope of work Total quantity 1 is equal t.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Dynamic balancing of rotor with 2 point 5microns accuracy size more than 48 kg up to 96 kg as per Part B scope of work Total quantity 1 is equal t.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Dynamic balancing of rotor with 2 point 5microns accuracy size more than 96 kg up to 192 kg as per Part B scope of work Total quantity 1 is equal .. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Dynamic balancing of rotor with 2 point 5microns accuracy size more than 192 kg up to 378 kg as per Part B scope of work Total quantity 1 is equal.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Dynamic balancing of rotor with 2 point 5microns accuracy size more than 378 kg up to 500 kg as per Part B scope of work Total quantity 1 is equal.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Dynamic balancing of rotor with 2 point 5microns accuracy size more than 500 kg up to 1000 kg as per Part B scope of work Total quantity 1 is equa.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Dynamic balancing of rotor with 2 point 5microns accuracy size more than 1000 kg up to 1500 kg as per Part B scope of work Total quantity 1 is equ.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Dynamic balancing of rotor with 2 point 5microns accuracy size more than 1500 kg up to 3000 kg as per Part B scope of work Total quantity 1 is equ.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Supply and installation of terminal plate or terminal studs with insulators One quantity includes terminal studs for all three phases size up to 1 .. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Supply and installation of terminal plate or terminal studs with insulators One quantity includes terminal studs for all three phases size more tha.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and Supply and installation of terminal plate or terminal studs with insulators One quantity includes terminal studs for all three phases size more th.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Removing of shaft making of new shaft and refitting of shaft with key way Material used shall be same as original and material is in contractor sco.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Making of end cover including machining drilling and threading etc to size up to 1 point 5 kW Material cast iron for above end cover is in contra.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Making of end cover including machining drilling and threading etc to size more than 1 point 5kW up to 7 point 5 kW Material cast iron for above .. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Making of end cover including machining drilling and threading etc to size more than 7 point 5kW up to 15kW Material cast iron for above end cove.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Making of end cover including machining drilling and threading etc to size more than 15kW up to 45kW Material cast iron for above end cover is in .. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Making of end cover including machining drilling and threading etc to size more than 45kW up to 90kW Material cast iron for above end cover is in.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Making of end cover including machining drilling and threading etc to size more than 90kW up to 180kW Material cast iron for above end cover is in.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Making of cooling fan including machining keyway and key hub Excluding material size up to 1 point 5 kW as per Part B scope of work Total quanti.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Making of cooling fan including machining keyway and key hub Excluding material size more than 1 point 5kW up to 7 point 5 kW as per Part B scope.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Making of cooling fan including machining keyway and key hub Excluding material size more than 7 point 5kW up to 15kW as per Part B scope of work .. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Making of cooling fan including machining keyway and key hub Excluding material size more than 15kW up to 45kW as per Part B scope of work Total q.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Making of cooling fan including machining keyway and key hub Excluding material size more than 45kW up to 90kW as per Part B scope of work Total.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Making of cooling fan including machining keyway and key hub Excluding material size more than 90kW up to 180kW as per Part B scope of work Total.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Material cost iron for making of cooling fan end cover as per Part B scope of work Total quantity to 100 Kg for two years; Service Provi.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Providing and fixing of bearing plates with material Same as original size up to 1 point 5 kW as per Part B scope of work Total quantity 1 is eq.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Providing and fixing of bearing plates with material Same as original size more than 1 point 5kW up to 7 point 5 kW as per Part B scope of work .. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Providing and fixing of bearing plates with material Same as original size more than 7 point 5kW up to 15kW as per Part B scope of work Total qu.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Providing and fixing of bearing plates with material Same as original size more than 15Kw up to 45kW as per Part B scope of work Total quantity .. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Providing and fixing of bearing plates with material Same as original size more than 45kW up to 90kW as per Part B scope of work Total quantity 1.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Providing and fixing of bearing plates with material Same as original size more than 90kW up to 180kW as per Part B scope of work Total quantity .. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Providing and fixing of bearing locks duly machined threaded and drilled with material Same as original size up to 15kW as per Part B scope of work.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Providing and fixing of bearing locks duly machined threaded and drilled with material Same as original size more than 15kW up to 45kW as per Part .. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Providing and fixing of bearing locks duly machined threaded and drilled with material Same as original size more than 45kW up to 90kW as per Part .. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Providing and fixing of bearing locks duly machined threaded and drilled with material Same as original size more than 90kW to 180kW as per Part B.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Providing and fixing of foundation legs including machining drilling and levelling etc Material shall be in contractor scope size up to 1 point 5 k.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Providing and fixing of foundation legs including machining drilling and levelling etc Material shall be in contractor scope size more than 1 point.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Providing and fixing of foundation legs including machining drilling and levelling etc Material shall be in contractor scope size more than 7 point.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Providing and fixing of foundation legs including machining drilling and levelling etc Material shall be in contractor scope size more than 15 up t.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site Dismantling and refitting without varnish and baking size up to 1 point 5 kW as per Part B scope of work Total quantity 1 is equal to 2 Nos for tw.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Dismantling and refitting without varnish and baking size more than 1 point 5kW up to 7 point 5kW as per Part B scope of work Total quantity 1 is e.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Dismantling and refitting without varnish and baking size more than 7 point 5kW up to 15kW as per Part B scope of work Total quantity 1 is equal t.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Dismantling and refitting without varnish and baking size more than 15kW up to 45kW as per Part B scope of work Total quantity 1 is equal to 2 Nos .. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Dismantling and refitting without varnish and baking size more than 45kW up to 90kW as per Part B scope of work Total quantity 1 is equal to 1 Nos.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Dismantling and refitting without varnish and baking size more than 90kW up to 180kW as per Part B scope of work Total quantity 1 is equal to 1 No.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Dismantling and refitting with varnish and baking size up to 1 point 5 kW as per Part B scope of work Total quantity 1 is equal to 5 Nos for two y.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Dismantling and refitting with varnish and baking size more than 1 point 5kW up to 7 point 5kW as per Part B scope of work Total quantity 1 is equa.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Dismantling and refitting with varnish and baking size more than 7 point 5kW up to 15kW as per Part B scope of work Total quantity 1 is equal to 3 .. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Dismantling and refitting with varnish and baking size more than 15kW up to 45kW as per Part B scope of work Total quantity 1 is equal to 3 Nos for.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Dismantling and refitting with varnish and baking size more than 45kW up to 90kW as per Part B scope of work Total quantity 1 is equal to 2 Nos for.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Dismantling and refitting with varnish and baking size more than 90kW up to 180kW as per Part B scope of work Total quantity 1 is equal to 3 Nos fo.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Providing and Fixing of oil seal size less than 1 point 1 kW as per Part B scope of work Total quantity 1 is equal to 5 Nos for two years; Service.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Providing and Fixing of oil seal size 1 point 1 kW to 2 point 2 kW as per Part B scope of work Total quantity 1 is equal to 5 Nos for two years; .. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Providing and Fixing of oil seal size more than 2 point 2 kW up to 5 point 5 kW as per Part B scope of work Total quantity 1 is equal to 5 Nos f.. , Repair, Maintenance Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Providing and Fixing of oil seal size more than 5 point 5 kW up to 15 kW as per Part B scope of work Total quantity 1 is equal to 5 Nos for two y.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Providing and Fixing of oil seal size more than 15kW up to 30kW as per Part B scope of work Total quantity 1 is equal to 5 Nos for two years; Ser.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Providing and Fixing of Space Heater size More than 30 up to 45kW as per Part B scope of work Total quantity 1 is equal to 2 Nos for two years; Se.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Providing and Fixing of Space Heater size More than 45kW up to 90kW as per Part B scope of work Total quantity 1 is equal to 2 Nos for two years; S.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Providing and Fixing of Space Heater size More than 90kW up to 180kW as per Part B scope of work Total quantity 1 is equal to 2 Nos for two years; .. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Providing of SKF make Bearing 6203 ZZ as per Part B scope of work Total quantity 1 is equal to 10 Nos for two years; Service Provider , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Providing of SKF make Bearing 6204 ZZ as per Part B scope of work Total quantity 1 is equal to 10 Nos for two years; Service Provider , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Providing of SKF make Bearing 6205 ZZ as per Part B scope of work Total quantity 1 is equal to 10 Nos for two years; Service Provider , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Providing of SKF make Bearing 6206 ZZ as per Part B scope of work Total quantity 1 is equal to 10 Nos for two years; Service Provider , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Providing of SKF make Bearing 6208 ZZ as per Part B scope of work Total quantity 1 is equal to 10 Nos for two years; Service Provider , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Providing of SKF make Bearing 6209 ZZ as per Part B scope of work Total quantity 1 is equal to 10 Nos for two years; Service Provider , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Providing of SKF make Bearing 6310 ZZ as per Part B scope of work Total quantity 1 is equal to 10 Nos for two years; Service Provider , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Providing of SKF make Bearing 6312 as per Part B scope of work Total quantity 1 is equal to 10 Nos for two years; Service Provider , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Providing of SKF make Bearing 6312 ZZ as per Part B scope of work Total quantity 1 is equal to 10 Nos for two years; Service Provider , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Providing of SKF make Bearing 6313 C3 as per Part B scope of work Total quantity 1 is equal to 10 Nos for two years; Service Provider , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Rewinding of Three phase 415 V 50Hz Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Rewinding of Three phase 415 V 50Hz motors size More than 90 kW up to 110 kW as per Part C scope of work Total quantity 1 is equal to 1 Nos for t.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Rewinding of Three phase 415 V 50Hz motors size More than 110 kW up to 132 kW as per Part C scope of work Total quantity 1 is equal to 1 Nos for.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - RR Site unit 3 and 4; Rewinding of Three phase 415 V 50Hz motors 1. Rewinding of Three phase, 415 V, 50Hz, motors of less than 1.1kW rating as per Part-A, Scope of work. (Total quantity 1 is equal to 12 Nos. for two years). Price/Qty. 1 2. Rewinding of Three phase, 415 V, 50Hz, motors of more than 1.1 kW up to 2.2 kW rating as per Part-A scope of work (Total quantity 1 is equal to 12 Nos. for two years). Price/Qty. 1 3. Rewinding of Three phase, 415 V, 50Hz, motors of more than 2.2 kW up to 5.5 kW rating as per Part-A scope of work (Total quantity 1 is equal to 10 Nos. for two years). Price/Qty. 1 4. Rewinding of Three phase, 415 V, 50Hz, motors of more than 5.5 kW up to 11 kW rating as per Part-A scope of work (Total quantity 1 is equal to 08 Nos. for two years). Price/Qty. 1 5. Rewinding of Three phase, 415 V, 50Hz, motors of more than 11 kW up to 22 kW rating as per Part-A scope of work (Total quantity 1 is equal to 05 Nos. for two years). Price/Qty. 1 6. Rewinding of Three phase, 415 V, 50Hz, motors of more than 22 kW up to 55 kW rating as per Part-A scope of work (Total quantity 1 is equal to 05 Nos. for two years). Price/Qty. 1 7. Rewinding of Three phase, 415 V, 50Hz, motors of more than 55 kW up to 75 kW rating as per Part-A scope of work (Total quantity 1 is equal to 02 Nos. for two years). Price/Qty. 1 8. Rewinding of Three phase, 415 V, 50Hz, motors of more than 75 kW up to 90 kW rating as per Part-A scope of work (Total quantity 1 is equal to 02 Nos. for two years). Price/Qty. 1 9. Rewinding of Three phase, 415 V, 50Hz, motors of more than 90 kW up to 110 kW rating as per Part-A scope of work (Total quantity 1 is equal to 01 Nos. for two years). Price/Qty. 1 10. Rewinding of Three phase, 415 V, 50Hz, motors of more than 110 kW up to 132 kW rating as per Part-A scope of work (Total quantity 1 is equal to 02 Nos. for two years). Price/Qty. 1 11. Rewinding of Three phase, 415 V, 50Hz, motors of more than 132 kW up to 140 kW rating as per Part-A scope of work (Total quantity 1 is equal to 01 Nos. for two years). Price/Qty. 1 12. Rewinding of Three phase, 415 V, 50Hz, motors of more than 140 kW up to 180 kW rating as per Part-A scope of work (Total quantity 1 is equal to 02 Nos. for two years). Price/Qty. 1 13. Rewinding of Three phase, 415 V, 50Hz, Submersible pump motors up to 2.5 kW rating as per Part-A scope of work (Total quantity 1 is equal to 06 Nos. for two years). Price/Qty. 1 14. Rewinding of Three phase, 415 V, 50Hz, Submersible pump motors more than 2.5 kW up to 5.5 kW rating as per Part-A scope of work (Total quantity 1 is equal to 06 Nos. for two years). Price/Qty. 1 15. Rewinding of Three phase, 415 V, 50Hz, Submersible pump motors more than 5.5 kW up to 11 kW rating as per Part-A scope of work (Total quantity 1 is equal to 03 Nos. for two years). Price/Qty. 1 16. Rewinding of Three phase, 415 V, 50Hz, Submersible pump motors more than 11 kW up to 15 kW rating as per Part-A scope of work (Total quantity 1 is equal to 01 Nos. for two years). Price/Qty. 1 17. Rewinding of Three phase, 415 V, 50Hz, Submersible pump motors more than 15 kW up to 37 kW rating as per Part-A scope of work (Total quantity 1 is equal to 01 Nos. for two years). Price/Qty. 1 18. Rewinding of Single phase, 230 V, 50Hz, motors of Ceiling fan 1200 mm sweep as per Part-A, Scope of work. (Total quantity 1 is equal to 75 Nos. for two years). Price19. Rewinding of Single phase, 230 V, 50Hz, motors of Pedestal fan/ wall mounted fan/ Exhaust fan up to 450 mm sweep as per Part-A, Scope of work. (Total quantity 1 is equal to 150 Nos. for two years). Price/Qty 1 20. Rewinding of Single phase, 230 V, 50Hz, motors of Exhaust fan/cooler fan above 400 mm sweep as per Part-A, Scope of work. (Total quantity 1 is equal to 50 Nos. for two years). Price/Qty 1 21. Rewinding of Self-starter motor, 24V, DC, Type 10TH-232-C suitable for greave diesel engine, Model -64DX-Mark-II as per Part-A, Scope of work. (Total quantity 1 is equal to 04 Nos. for two years). Price/Qty 1 22. Rewinding of 2000 VA Control Transformer as per Part-A, Scope of work. (Total quantity 1 is equal to 02 Nos. for two years). Price/Qty 1 23. Rewinding of 1000 VA Control Transformer as per Part-A, Scope of work. (Total quantity 1 is equal to 02 Nos. for two years). Price/Qty 1 24. Rewinding of 500 VA Control Transformer as per Part-A, Scope of work. (Total quantity 1 is equal to 02 Nos. for two years). Price/Qty 1 25. Rewinding of control coil 415V, Diameter up to 300MM including bobbin as per Part-A, Scope of work. (Total quantity 1 is equal to 02 Nos. for two years). Price/Qty 1 26. Rewinding of Single phase, 230 V, 50Hz, Submersible pump motors up to 1.5 kW rating as per Part-A scope of work (Total quantity 1 is equal to 02 Nos. for two years). Price/Qty 1 27. Supply and installation of Shaft for Ceiling fan/pedestal fans as per Part-A scope of work (Total quantity 1 is equal to 25 Nos. for two years). Price/Qty 1 28. Supply and installation of Gun metal bushes as per Part-A scope of work (Total quantity 1 is equal to 25 Nos. for two years). Price/Qty 1 29. Repair of hot spot in Three phase, 415 V, 50Hz, motors up to 1.5 kW rating as per Part-B scope of work (Total quantity 1 is equal to 02 Nos. for two years). Price/Qty 1 30. Repair of hot spot in Three phase, 415 V, 50Hz, motors of more than 1.5 kW up to 7.5 kW rating as per Part-B scope of work (Total quantity 1 is equal to 02 Nos. for two years). Price/Qty 1 31. Repair of hot spot in Three phase, 415 V, 50Hz, motors of more than 7.5 kW up to 22 kW rating as per Part-B scope of work (Total quantity 1 is equal to 01 Nos. for two years). Price/Qty 1 32. Repair of hot spot in Three phase, 415 V, 50Hz, motors of more than 22 kW up to 45 kW rating as per Part-B scope of work (Total quantity 1 is equal to 01 Nos. for two years). Price/Qty 1 33. Repair of hot spot in Three phase, 415 V, 50Hz, motors of more than 45 kW up to 90 kW rating as per Part-B scope of work (Total quantity 1 is equal to 01 Nos. for two years). Price/Qty 1 34. Repair of hot spot in Three phase, 415 V, 50Hz, motors of more than 90 kW up to 180kW rating as per Part-B scope of work (Total quantity 1 is equal to 01 Nos. for two years). Price/Qty 1 35. Removal of hot-spot by dismantling of total stampings in Three phase, 415 V, 50Hz, motors up to 22 kW rating as per Part-B scope of work (Total quantity 1 is equal to 25 per cm for two years). Price/Qty 1 36. Removal of hot-spot by dismantling of total stampings in Three phase, 415 V, 50Hz, motors of more than 22 kW up to 45 kW rating as per Part-B scope of work (Total quantity 1 is equal to 25 per cm for two years). Price/Qty 1 37. Removal of hot-spot by dismantling of total stampings in Three phase, 415 V, 50Hz, motors of more than 45 kW up to 90 kW rating as per Part-B scope of work (Total quantity 1 is equal to 40 per cm for two years). Price/Qty 1 38. Removal of hot-spot by dismantling of total stampings in Three phase, 415 V, 50Hz, motors of more than 90 kW up to 180 kW rating as per Part-B scope of work (Total quantity 1 is equal to 40 per cm for two years). Price/Qty 1 39. Re-metalizing of shaft using TAFA arc technique after preparation of surface and machining to proper size up to 1.5 kW motor as per Part-B scope of work (Total quantity 1 is equal to 15 Nos. for two years). 40. Re-metalizing of shaft using TAFA arc technique after preparation of surface and machining to proper size more than 1.5kW up to 7.5 kW motor as per Part- B scope of work (Total quantity 1 is equal to 15 Nos. for two years). Price/Qty 1 41. Re-metalizing of shaft using TAFA arc technique after preparation of surface and machining to proper size more than 7.5 kW up to 15kW motor as per Part-B scope of work (Total quantity 1 is equal to 10 Nos. for two years). Price/Qty 1 42. Re-metalizing of shaft using TAFA arc technique after preparation of surface and machining to proper size more than 15 up to 45 kW motor as per Part-B scope of work (Total quantity 1 is equal to 10 Nos. for two years). Price/Qty 1 43. Re-metalizing of shaft using TAFA arc technique after preparation of surface and machining to proper size more than 45kW up to 90 kW motor as per Part-B scope of work (Total quantity 1 is equal to 5 Nos. for two years). Price/Qty 1 44. Re-metalizing of shaft using TAFA arc technique after preparation of surface and machining to proper size more than 90kW to 180kW motor as per Part-B scope of work (Total quantity 1 is equal to 5 Nos. for two years). Price/Qty 1 45. Re-metalizing of end covers using TAFA arc technique after preparation of surface and machining to proper size up to 1.5 kW motor as per Part-B scope of work (Total quantity 1 is equal to 15 Nos. for two years). Price/Qty 1 46. Re-metalizing of end covers using TAFA arc technique after preparation of surface and machining to proper size more than 1.5 kW up to 7.5 kW motor as per Part-B scope of work (Total quantity 1 is equal to 15 Nos. for two years). Price/Qty 1 47. Re-metalizing of end covers using TAFA arc technique after preparation of surface and machining to proper size more than 7.5 kW to 15kW motor as per Part-B scope of work (Total quantity 1 is equal to 12 Nos. for two years). Price/Qty 1 48. Re-metalizing of end covers using TAFA arc technique after preparation of surface and machining to proper size more than 15 kW up to 45 kW motor as per Part-B scope of work (Total quantity 1 is equal to 12 Nos. for two years). Price/Qty 1 49. Re-metalizing of end covers using TAFA arc technique after preparation of surface and machining to proper size more than 45kW up to 90 kW motor as per Part-B scope of work (Total quantity 1 is equal to 5 Nos. for two years). Price/Qty 1 50. Re-metalizing of end covers using TAFA arc technique after preparation of surface and machining to proper size more than 90 kW to 180kW motor as per Part-B scope of work (Total quantity 1 is equal to 5 Nos. for two years). Price/Qty 1 51. Replacement of PVC cooling fan for motors size up to 1.5 kW as per Part-B scope of work (Total quantity 1 is equal to 8 Nos. for two years). Price/Qty 1 52. Replacement of PVC cooling fan for motors size more than 1.5kW up to 7.5 kW as per Part-B scope of work (Total quantity 1 is equal to 8 Nos. for two years). Price/Qty 1 53. Replacement of PVC cooling fan for motors size more than 7.5kW unto 15kW as per Part-B scope of work (Total quantity 1 is equal to 8 Nos. for two years). Price/Qty 1 54. Replacement of PVC cooling fan for motors size more than 15kW up to 45kW as per Part-B scope of work (Total quantity 1 is equal to 8 Nos. for two years). Price/Qty 1 55. Dynamic balancing of rotor with 2.5microns accuracy size more than 1kg up to 4 kg as per Part-B scope of work (Total quantity 1 is equal to 2 Nos. for two years). Price/Qty 1 56. Dynamic balancing of rotor with 2.5microns accuracy size more than 4 kg up to 16 kg as per Part-B scope of work (Total quantity 1 is equal to 5 Nos. for two years). Price/Qty 1 57. Dynamic balancing of rotor with 2.5microns accuracy size more than 16 kg up to 48 kg as per Part-B scope of work (Total quantity 1 is equal to 5 Nos. for two years). Price/Qty 1 58. Dynamic balancing of rotor with 2.5microns accuracy size more than 48 kg up to 96 kg as per Part-B scope of work (Total quantity 1 is equal to 5 Nos. for two years). Price/Qty 1 59. Dynamic balancing of rotor with 2.5microns accuracy size more than 96 kg up to 192 kg as per Part-B scope of work (Total quantity 1 is equal to 2 Nos. for two years). 60. Dynamic balancing of rotor with 2.5microns accuracy size more than 192 kg up to 378 kg as per Part-B scope of work (Total quantity 1 is equal to 2 Nos. for two years). Price/Qty 1 61. Dynamic balancing of rotor with 2.5microns accuracy size more than 378 kg up to 500 kg as per Part-B scope of work (Total quantity 1 is equal to 1 Nos. for two years). Price/Qty 1 62. Dynamic balancing of rotor with 2.5microns accuracy size more than 500 kg up to 1000 kg as per Part-B scope of work (Total quantity 1 is equal to 1 Nos. for two years). Price/Qty 1 63. Dynamic balancing of rotor with 2.5microns accuracy size more than 1000 kg up to 1500 kg as per Part-B scope of work (Total quantity 1 is equal to 1 Nos. for two years). Price/Qty 1 64. Dynamic balancing of rotor with 2.5microns accuracy size more than 1500 kg up to 3000 kg as per Part-B scope of work (Total quantity 1 is equal to 1 Nos. for two years). Price/Qty 1 65. Supply and installation of terminal plate/ terminal studs with insulators (One quantity includes terminal studs for all three phases) size up to 1.5kW as per Part-B scope of work (Total quantity 1 is equal to 2 Nos. for two years). Price/Qty 1 66. Supply and installation of terminal plate/ terminal studs with insulators (One quantity includes terminal studs for all three phases) size more than 1.5kW up to 7.5kW as per Part-B scope of work (Total quantity 1 is equal to 2 Nos. for two years). Price/Qty 1 67. Supply and installation of terminal plate/ terminal studs with insulators (One quantity includes terminal studs for all three phases) size more than 7.5kW up to 15kW as per Part-B scope of work (Total quantity 1 is equal to 2 Nos. for two years). Price/Qty 1 68. Supply and installation of terminal plate/ terminal studs with insulators (One quantity includes terminal studs for all three phases) size more than 15kW up to 45kW as per Part-B scope of work (Total quantity 1 is equal to 2 Nos. for two years). Price/Qty 1 69. Supply and installation of terminal plate/ terminal studs with insulators (One quantity includes terminal studs for all three phases) size more than 45kW up to 90kW as per Part-B scope of work (Total quantity 1 is equal to 2 Nos. for two years). Price/Qty 1 70. Supply and installation of terminal plate/ terminal studs with insulators (One quantity includes terminal studs for all three phases) size more than 90kW up to 180kW as per Part-B scope of work (Total quantity 1 is equal to 2 Nos. for two years). Price/Qty 1 71. Removing of shaft, making of new shaft & refitting of shaft with key way. (Material used shall be same as original and material is in contractor scope) size up to 1.5 kW as per Part-B scope of work (Total quantity 1 is equal to 1 Nos. for two years). Price/Qty 1 72. Removing of shaft, making of new shaft & refitting of shaft with key way. (Material used shall be same as original and material is in contractor scope) size more than 1.5kW up to 7.5 kW as per Part-B scope of work (Total quantity 1 is equal to 1 Nos. for two years). Price/Qty 1 73. Removing of shaft, making of new shaft & refitting of shaft with key way. (Material used shall be same as original and material is in contractor scope) size more than 7.5kW to 15kW as per Part-B scope of work (Total quantity 1 is equal to 1 Nos. for two years). Price/Qty 1 74. Removing of shaft, making of new shaft & refitting of shaft with key way. (Material used shall be same as original and material is in contractor scope) size more than 15kW to 45 kW as per Part-B scope of work (Total quantity 1 is equal to 1 Nos. for two years). Price/Qty 1 75. Making of end cover including , machining, drilling and threading etc. to size up to 1.5 kW ( Material cast iron for above end cover is in contractor scope) as per Part-B scope of work (Total quantity 1 is equal to 1 Nos. for two years). 76. Making of end cover including , machining, drilling and threading etc. to size more than 1.5kW up to 7.5 kW ( Material cast iron for above end cover is in contractor scope) as per Part-B scope of work (Total quantity 1 is equal to 1 Nos. for two years). Price/Qty 1 77. Making of end cover including , machining, drilling and threading etc. to size more than 7.5kW up to 15kW ( Material cast iron for above end cover is in contractor scope) as per Part-B scope of work (Total quantity 1 is equal to 1 Nos. for two years). Price/Qty 1 78. Making of end cover including , machining, drilling and threading etc. to size more than 15kW up to 45kW (Material cast iron for above end cover is in contractor scope) as per Part-B scope of work (Total quantity 1 is equal to 1 Nos. for two years). Price/Qty 1 79. Making of end cover including , machining, drilling and threading etc. to size more than 45kW up to 90kW ( Material cast iron for above end cover is in contractor scope) as per Part-B scope of work (Total quantity 1 is equal to 1 Nos. for two years). Price/Qty 1 80. Making of end cover including , machining, drilling and threading etc. to size more than 90kW up to 180kW ( Material cast iron for above end cover is in contractor scope) as per Part-B scope of work (Total quantity 1 is equal to 1 Nos. for two years). Price/Qty 1 81. Making of cooling fan including , machining, keyway & key hub: (Excluding material) size up to 1.5 kW as per Part-B scope of work (Total quantity 1 is equal to 2 Nos. for two years). Price/Qty 1 82. Making of cooling fan including , machining, keyway & key hub: (Excluding material) size more than 1.5kW up to 7.5 kW as per Part-B scope of work (Total quantity 1 is equal to 2 Nos. for two years). Price/Qty 1 83. Making of cooling fan including , machining, keyway & key hub: (Excluding material) size more than 7.5kW up to 15kW as per Part-B scope of work (Total quantity 1 is equal to 2 Nos. for two years). Price/Qty 1 84. Making of cooling fan including , machining, keyway & key hub: (Excluding material) size more than 15kW up to 45kW as per Part-B scope of work (Total quantity 1 is equal to 2 Nos. for two years). Price/Qty 1 85. Making of cooling fan including , machining, keyway & key hub: (Excluding material) size more than 45kW up to 90kW as per Part-B scope of work (Total quantity 1 is equal to 1 Nos. for two years). Price/Qty 1 86. Making of cooling fan including , machining, keyway & key hub: (Excluding material) size more than 90kW up to 180kW as per Part-B scope of work (Total quantity 1 is equal to 1 Nos. for two years). Price/Qty 1 87. Material cost iron for making of cooling fan, end cover as per Part-B scope of work (Total quantity 1 is equal to 100 Kg for two years). Price/Qty 1 88. Providing & fixing of bearing plates with material (Same as original) size up to 1.5 kW as per Part-B scope of work (Total quantity 1 is equal to 2 Nos. for two years). Price/Qty 1 89. Providing & fixing of bearing plates with material (Same as original) size more than 1.5kW up to 7.5 kW as per Part-B scope of work (Total quantity 1 is equal to 2 Nos. for two years). Price/Qty 1 90. Providing & fixing of bearing plates with material (Same as original) size more than 7.5kW up to 15kW as per Part-B scope of work (Total quantity 1 is equal to 2 Nos. for two years). Price/Qty 1 91. Providing & fixing of bearing plates with material (Same as original) size more than 15Kw up to 45kW as per Part-B scope of work (Total quantity 1 is equal to 2 Nos. for two years). Price/Qty 1 92. Providing & fixing of bearing plates with material (Same as original) size more than 45kW up to 90kW as per Part-B scope of work (Total quantity 1 is equal to 1 Nos. for two years). Price/Qty 1 93. Providing & fixing of bearing plates with material (Same as original) size more than 90kW up to 180kW as per Part-B scope of work (Total quantity 1 is equal to 1 Nos. for two years). 94. Providing and fixing of bearing locks (duly machined threaded & drilled) with material (Same as original) size up to 15kW as per Part-B scope of work (Total quantity 1 is equal to 2 Nos. for two years). Price/Qty 1 95. Providing and fixing of bearing locks (duly machined threaded & drilled) with material (Same as original) size more than 15kW up to 45kW as per Part-B scope of work (Total quantity 1 is equal to 2 Nos. for two years). Price/Qty 1 96. Providing and fixing of bearing locks (duly machined threaded & drilled) with material (Same as original) size more than 45kW up to 90kW as per Part-B scope of work (Total quantity 1 is equal to 1 Nos. for two years). Price/Qty 1 97. Providing and fixing of bearing locks (duly machined threaded & drilled) with material (Same as original) size more than 90kW to 180kW as per Part-B scope of work (Total quantity 1 is equal to 1 Nos. for two years). Price/Qty 1 98. Providing & fixing of foundation legs including machining, drilling & levelling etc. (Material shall be in contractor scope) size up to 1.5 kW as per Part-B scope of work (Total quantity 1 is equal to 1 Nos. for two years). Price/Qty 1 99. Providing & fixing of foundation legs including machining, drilling & levelling etc. (Material shall be in contractor scope) size more than 1.5kW up to 7.5 kW as per Part-B scope of work (Total quantity 1 is equal to 1 Nos. for two years). Price/Qty 1 100. Providing & fixing of foundation legs including machining, drilling & levelling etc. (Material shall be in contractor scope) size more than 7.5kW up to 15kW as per Part-B scope of work (Total quantity 1 is equal to 1 Nos. for two years). Price/Qty 1 101. Providing & fixing of foundation legs including machining, drilling & levelling etc. (Material shall be in contractor scope) size more than 15 up to 45kW as per Part-B scope of work (Total quantity 1 is equal to 1 Nos. for two years). Price/Qty 1 102. Dismantling and refitting without varnish and baking size up to 1.5 kW as per Part-B scope of work (Total quantity 1 is equal to 2 Nos. for two years). Price/Qty 1 103. Dismantling and refitting without varnish and baking size more than 1.5kW up to 7.5kW as per Part-B scope of work (Total quantity 1 is equal to 2 Nos. for two years). Price/Qty 1 104. Dismantling and refitting without varnish and baking size more than 7.5kW up to 15kW as per Part-B scope of work (Total quantity 1 is equal to 2 Nos. for two years). Price/Qty 1 105. Dismantling and refitting without varnish and baking size more than 15kW up to 45kW as per Part-B scope of work (Total quantity 1 is equal to 2 Nos. for two years). Price/Qty 1 106. Dismantling and refitting without varnish and baking size more than 45kW up to 90kW as per Part-B scope of work (Total quantity 1 is equal to 1 Nos. for two years). Price/Qty 1 107. Dismantling and refitting without varnish and baking size more than 90kW up to 180kW as per Part-B scope of work (Total quantity 1 is equal to 1 Nos. for two years). Price/Qty 1 108. Dismantling and refitting with varnish and baking size up to 1.5 kW as per Part- B scope of work (Total quantity 1 is equal to 5 Nos. for two years). Price/Qty 1 109. Dismantling and refitting with varnish and baking size more than 1.5kW up to 7.5kW as per Part-B scope of work (Total quantity 1 is equal to 5 Nos. for two years). Price/Qty 1 110. Dismantling and refitting with varnish and baking size more than 7.5kW up to 15kW as per Part-B scope of work (Total quantity 1 is equal to 3 Nos. for two years). Price/Qty 1 111. Dismantling and refitting with varnish and baking size more than 15kW up to 45kW as per Part-B scope of work (Total quantity 1 is equal to 3 Nos. for two years). Price/Qty 1 112. Dismantling and refitting with varnish and baking size more than 45kW up to 90kW as per Part-B scope of work (Total quantity 1 is equal to 2 Nos. for two years). Price/Qty 1 113. Dismantling and refitting with varnish and baking size more than 90kW up to 180kW as per Part-B scope of work (Total quantity 1 is equal to 3 Nos. for two years). 114. Providing & Fixing of oil seal size less than 1.1 kW as per Part-B scope of work (Total quantity 1 is equal to 5 Nos. for two years). Price/Qty 1 115. Providing & Fixing of oil seal size 1.1 kW to 2.2 kW as per Part-B scope of work (Total quantity 1 is equal to 5 Nos. for two years). Price/Qty 1 116. Providing & Fixing of oil seal size more than 2.2 kW up to 5.5 kW as per Part- B scope of work (Total quantity 1 is equal to 5 Nos. for two years). Price/Qty 1 117. Providing & Fixing of oil seal size more than 5.5 kW up to 15 kW as per Part-B scope of work (Total quantity 1 is equal to 5 Nos. for two years). Price/Qty 1 118. Providing & Fixing of oil seal size more than 15kW up to 30kW as per Part-B scope of work (Total quantity 1 is equal to 5 Nos. for two years). Price/Qty 1 119. Providing & Fixing of Space Heater size More than 30 up to 45kW as per Part- B scope of work (Total quantity 1 is equal to 2 Nos. for two years). Price/Qty 1 120. Providing & Fixing of Space Heater size More than 45kW up to 90kW as per Part-B scope of work (Total quantity 1 is equal to 2 Nos. for two years). Price/Qty 1 121. Providing & Fixing of Space Heater size More than 90kW up to 180kW as per Part-B scope of work (Total quantity 1 is equal to 2 Nos. for two years). Price/Qty 1 122. Providing of SKF make Bearing 6203 ZZ as per Part-B scope of work (Total quantity 1 is equal to 10 Nos. for two years). Price/Qty 1 123. Providing of SKF make Bearing 6204 ZZ as per Part-B scope of work (Total quantity 1 is equal to 10 Nos. for two years). Price/Qty 1 124. Providing of SKF make Bearing 6205 ZZ as per Part-B scope of work (Total quantity 1 is equal to 10 Nos. for two years). Price/Qty 1 125. Providing of SKF make Bearing 6206 ZZ as per Part-B scope of work (Total quantity 1 is equal to 10 Nos. for two years). Price/Qty 1 126. Providing of SKF make Bearing 6208 ZZ as per Part-B scope of work (Total quantity 1 is equal to 10 Nos. for two years). Price/Qty 1 127. Providing of SKF make Bearing 6209 ZZ as per Part-B scope of work (Total quantity 1 is equal to 10 Nos. for two years). Price/Qty 1 128. Providing of SKF make Bearing 6310 ZZ as per Part-B scope of work (Total quantity 1 is equal to 10 Nos. for two years). Price/Qty 1 129. Providing of SKF make Bearing 6312 as per Part-B scope of work (Total quantity 1 is equal to 10 Nos. for two years). Price/Qty 1 130. Providing of SKF make Bearing 6312 ZZ as per Part-B scope of work (Total quantity 1 is equal to 10 Nos. for two years). Price/Qty 1 131. Providing of SKF make Bearing 6313-C3 as per Part-B scope of work (Total quantity 1 is equal to 10 Nos. for two years). Price/Qty 1 132. Rewinding of Three phase, 415 V, 50Hz, motors size more than 75 kW up to 90 kW as per Part-C scope of work (Total quantity 1 is equal to 1 Nos. for two years). Price/Qty 1 133. Rewinding of Three phase, 415 V, 50Hz, motors size More than 90 kW up to 110 kW as per Part-C scope of work (Total quantity 1 is equal to 1 Nos. for two years). Price/Qty 1 134. Rewinding of Three phase, 415 V , 50Hz, motors size More than 110 kW up to 132 kW as per Part-C scope of work (Total quantity 1 is equal to 1 Nos. for two years). Price/Qty 1 135. Rewinding of Three phase, 415 V, 50Hz, motors size More than 132 kW up to 140 kW as per Part-C scope of work (Total quantity 1 is equal to 1 Nos. for two years). Price/Qty 1 136. Rewinding of Three phase, 415 V, 50Hz, windings motors size More than 140 kW up to 180 kW as per Part-C scope of work (Total quantity 1 is equal to Total Quantity : 1

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 26-04-2025 02-05-2025

Key Value

Document Fees
Refer document
EMD
INR 156240.0 /-
Tender Value
INR 78.12 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail