Tender For Supply, Installation, Testing, Commissioning And Maintenance Of Hybrid Lan, & Ups Wiring In Various Th, Dh, Gh Across Kerala Under E-Health Project, Thiruvananthapuram-Kerala

Kerala State Electricity Board has published Tender For Supply, Installation, Testing, Commissioning And Maintenance Of Hybrid Lan, & Ups Wiring In Various Th, Dh, Gh Across Kerala Under E-Health Project. Submission Date for this Tender is 24-04-2025. Networking Equipments Tenders in Thiruvananthapuram Kerala. Bidders can get complete Tender details and download the document.




Tender Notice

48480578
Corrigendum : Tender For Supply, Installation, Testing, Commissioning And Maintenance Of Hybrid Lan, & Ups Wiring In Various Th, Dh, Gh Across Kerala Under E-Health Project
Open Tender
Indian
Kerala
Thiruvananthapuram
24-04-2025

Tender Details

Supply, Installation, Testing, Commissioning and Maintenance of Hybrid LAN, & UPS wiring in Various TH, DH, GH across Kerala Under e-Health Project --- 1 Outdoor O. F. Cable 6 Core SM 2 24 Port Fully loaded LIU Rack mountable 3 6 Port Fully loaded LIU Rack mountable 4 LC to SC Patch cord. SM 5 Cat6 4 Pair UTP Cable: 23 AWG 6 Cat 6 STP Out door Cable 7 Cat6 Information outlet 8 Face plate Singlex.- Cat6 9 3 x 3 Surface mount box for Cat6 Outlet 10 Cat6 patch cord,3 mtr 11 Cat6 patch cord, 1 mtr 12 Cat6 patch panel 24 port Fully Loaded 13 27U Floormount Rack with Accessories 14 9U Wallmount Rack with Accessories 15 6U Wallmount Rack with Accessories 16 Supply of Cable Route Marker with Angle Iron Leg 2 ft with painting 17 Supply of 25mm ISI PVC Conduit- Ivory 18 Supply of 32 mm HDPE Pipe 19 100X50 DLP Trunking with accessories 20 50X50 DLP Trunking with accessories 21 1.5/ 2 GI Pipe ISI Approved 22 3/ 3.5 GI Pipe ISI Approved 23 Router with 2x GE Enabled WAN (1000/100/10 Base T) with 2 RJ 45 with all acessories with 5 year 24X7 support 24 12 port Fully Managed Core Switch with all acessories with 5 year 24X7 support 25 Fully Managed 24 Port Network Switch with minimum 4* 1G SFP+ Uplink with 5 year 24X7 support pack 26 L2 Fully Managed 8 Port PoE Network Switch with minimum 2*1G SFP+ Uplink with 5 year 24X7 support pack 27 1G SFP Module(SM) 28 1G Copper Module 29 Supply of the following 1100V, Aluminium Cable, XLPE / AYFY in the existing cable trenches/cable trays /pipes/ etc. including supply and fixing of necessary clamping materials.2 X 16 Sq.mm , 415 V 30 4 X 16 Sq.mm , 415 V 31 Supply of all materials for termination of the following PVC insulated Armoured Aluminium LT cables (AYFY/A2XFY) using single compression type cadmium plated brass cable glands , Copper crimped type cable lugs, cable identification tags and including gland earthing using copper conductor of adequate size,Al-Cu strip for termination of cables etc.2 X 16 Sq.mm , 415 V 32 4 X 16 Sq.mm , 415 V 33 Supply of 63A Phase Selector 34 Supply of 4 way double door TPN VDB 35 Supply of 3 Pole Enclosure 36 Supply of 2 Pole Enclosure 37 Supply of 12 way SP DB 38 Supply of 8 way SP DB 39 Supply of 4 way SP DB 40 Supply of 2 PoleIsolator40A 41 Supply of 2 Pole ELCB 40A 100ma Leakage 42 Supply of 4 Pole 63A MCCB 43 Supply of 4 Pole 40A MCCB 44 Supply of 4 Pole 63A MCB 45 Supply of 3 Pole 63A MCB 46 Supply of 4 Pole 40A MCB 47 Supply of 3 Pole 40A MCB 48 Supply of 2 Pole MCB 40A 49 Supply of 1 Pole MCB 40A 50 Supply of 1 Pole MCB 25A 51 Supply of 1 Pole MCB 16A 52 Supply of 1 Pole MCB 6A 53 Supply of 1 nos of 10sq mmPVC insulated Copper Wire 54 Supply of 1 nos of 6sq mmPVC insulated Copper Wire 55 Supply of4 sq mmPVC insulated Copper Wire 56 Supply of 2 nos of 2.5 sq mm and 1 nos of 1.5 sq mm PVC insulated Copper Wire 57 Supply of10 SWG Bare Copper 58 Supply of 3 nos 6Asocket controlled by 2 switch 59 Supply of 2 nos of 6A socket controlled by 1switch 60 Supply of 1 nos of 6A socket controlled by 1switch 61 Supply of 1 nos of 16A socket controlled by 1switch 62 Supply of 20 mm PVC Conduit accessories 63 Supply of Exhaust Fan - 12 64 Supply of All materials for Plate(Galvanised Iron) Earthing as per IS-3043-1987 65 Supply of GI/Cu earthing conductors inclusive of providing earthing terminations and bracing of the terminations using necessary clamps, screws and bolts, PVC sleeves, etc. 25x6 Cu strip 66 Laying of OF Cable through PVC Conduit/ HDPE Pipe 67 Laying of OF Cable through GI Pole using stay wire 68 Splicing of OFC 69 Termination of LIU 70 Laying of 4 Pair UTP Cable Cat6 /STP 71 Fixing and termination of Information outlet with SMB- Cat6 72 Fixing and port termination of patch panel- Cat 6 73 Fixing & Dressing of Floormount Rack 74 Fixing & Dressing of wallmount Rack 75 Laying of 100X50 DLP trunking 76 Laying of 50X50 DLP trunking 77 Laying of 25 MM PVC Conduit 78 Laying charge for GI Pipe 79 Fixing of Access point 80 Digging, Laying of HDPE/Water Pipe in Hard Soil / Tar-Road / Concrete Excavation/Trenching, Baked-Brick- Layering, Refilling & Restoration/Resurfacing, upto 600mm depth.(For laying of UTP/OFC) 81 Fixing of Cable Route Marker 82 Laying of the following 1100V, Aluminium Cable, XLPE / AYFY in the existing cable trenches/cable trays /pipes/ etc. including supply and fixing of necessary clamping materials.2 X 16 Sq.mm , 415 V 83 4 X 16 Sq.mm , 415 V 84 Termination of all materials and termination of the following PVC insulated Armoured Aluminium LT cables (AYFY/A2XFY) using single compression type cadmium plated brass cable glands , Copper crimped type cable lugs, cable identification tags and including gland earthing using copper conductor of adequate size,Al-Cu strip for termination of cables etc. 2 X 16 Sq.mm , 415 V 85 4 X 16 Sq.mm , 415 V 86 Fixing of 63A phase selector 87 Fixing of 4 way double door TPNVDB 88 Fixing of 3 Pole Enclosure 89 Fixing of 2 Pole Enclosure 90 Fixing of 12 way SP DB 91 Fixing of 8 way SP DB 92 Fixing of 4 way SP DB 93 Fixing of 2 PoleIsolator40A 94 Fixing of 2 Pole ELCB 40A 100ma Leakage 95 Fixing of 4 Pole MCCB 63A 96 Fixing of 4 Pole MCB 40A 97 Fixing of 4 Pole MCB 63A 98 Fixing of 3 Pole MCB 63A 99 Fixing of 4 Pole MCB 40A 100 Fixing of 3 Pole MCB 40A 101 Supply of 2 Pole MCB 40A 102 Fixing of 1 Pole MCB 40A 103 Fixing of 1 Pole MCB 25A 104 Fixing of 1 Pole MCB 16A 105 Fixing of 1 Pole MCB 6A 106 Laying of 1 nos of 10 sq mmPVC insulated Copper Wire 107 Laying of 1 nos of 6sq mmPVC insulated Copper Wire 108 Laying of 1 nos of 4 sq mmPVC insulated Copper Wire 109 Laying of 2 nos of 2.5 sq mm and 1 nos of 1.5 sq mm PVC insulated Copper Wire 110 Laying of 2 X 10 SWG Bare Copper 111 Fixing of 3 nos 6Asocket controlled by 3 switch 112 Fixing of 2 nos 6Asocket controlled by 2 switch 113 Fixing of 1 nos of 6A socket controlled by 1switch 114 Fixing of 1 nos of 16A socket controlled by 1switch 115 Laying of 20 MM PVC Conduit accessories 116 Fixing of Exhaust Fan - 12 117 Fixing of All materials for Plate(Galvanised Iron) Earthing as per IS-3043-1987

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 19-04-2025 date 1 corrigendum Date 24-04-2025

Key Value

Document Fees
INR 7500 /-
EMD
INR 100000.0 /-
Tender Value
Refer document