| 1 | Excavation in post holes (or similar holes) each n exc 0.5cum getting out returning filling in and ramming earth or broken rubble mixed with earth around in layers n exc 25cm ,in hard and dense soil complete all as specified and directed. |
| 2 | M&L for MSwork as in post and struts in fencing incl embedding in concrete and cutting tops to shape as directed ,drilling holes notching for wire etc and similar works confriming to Fe 290 Gde E-165complete all as specified and directed. |
| 3 | M&L PCC 1:3:6(Type C-2 40mm graded aggregate) as in foundation complete all as specified and directed. |
| 4 | S&F Mild steel flat iron work as in bands, staps supports or stays for rain water ventilating pipes, including bolts, if required hooks , heay , for large gates hookand pintel hinges plain angle cleats confirming to Fe-290 Gde E-165 complete all as specified and directed. |
| 5 | Supply only chain link fencing mild steel galvanised fencing, weight not less than 3.9kg/sqm and 100 mm opening complete all as specified and directed. |
| 6 | Fixing only chain link fencing including line wires any mess, size and type to any type of stander, rails, straining bolts etc including provn of binding wires complete all as specified and directed. |
| 7 | S&F MS roundbars 12mm dia and over, cut to length,bent to shape required, including crankinbending spirally for hooping for columns, hooking ends and binding with and icl mildsteel wire annealed not less than0.9mm dia or securing with clips quality conforming to grade FE-410 complete all as specified and directed. |
| 8 | S&F galvanised, 2 strend steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacing and straing and fixing to any type of strand rails etc. complete all as specified and directed. |
| 9 | M&L for two coats of synthetics enamel paint on steel surfaces over one coat of red oxide primer including preparation of new steel surfaces complete all as specified and directed. |
| 10 | M&L for on surfaces of any description, n.exc 10cm in width or girth when unconnected with other painting or when painted in a different tintcomplete all as specified and directed. |
| 11 | Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion making good disturbed ground complete all as specified and directed. |
| 12 | Concertina coil: 1000 mm Dia/56 Loops/2.5 mm core wire.Coil Diameter: 1000 mm.Type of Strip: Heavy Galvanized (IS 1730).Type of Core wire: Heavy Galvanized (IS 280-2006). Core wire Diameter: 2.50 mm Dia.Zinc Coating to Strip: Minimum 200 GSM/Sqmm. Zine Coating on wire:Minimum 275 GSM/Sqmm (IS 6745-1972 reaffirmed 2006).Tensile Strength of wire: 1400-1500 N/Sq.mm. Weight: 6-8 kg (+ 5%).Number of Loops: 56.Blade Length: 22 mm.Barb Profile: Medium Blade (MBBT).Distance Between Barb:35 mm. Stretchable length: 6-8mtrs, Type of clip: Hardened Steelin Galvanized steel. complete all as specified and directed by Engr-in- Charge. |
| 13 | Concertina coil: 600 mm Dia/56 Loops/2.5 mm core wire.Coil Diameter: 600 mm.Type of Strip: Heavy Galvanized (IS 1730).Type of Core wire: Heavy Galvanized (IS 280-2006). Core wire Diameter: 2.50 mm Dia.Zinc Coating to Strip: Minimum 200 GSM/Sqmm. Zine Coating on wire:Minimum 275 GSM/Sqmm (IS 6745-1972 reaffirmed 2006).Tensile Strength of wire: 1400-1500 N/Sq.mm. Weight: 6-8 kg (+ 5%).Number of Loops: 56.Blade Length: 22 mm.Barb Profile: Medium Blade (MBBT).Distance Between Barb:35 mm. Stretchable length: 6-8mtrs, Type of clip: Hardened Steelin Galvanized steel. all as speciified and directed by Engr-in- Charge. |
| 14 | Supply and Fixing/installation of M.S sliding gate made up of M.S Hollow section and M.S sheet as per the provided design finised with one coat of redoxide priming, S.S wheel for sliding Gate (02x in each panel),Roller assembly with all rollers, H.T Roller Shafts, heavy duty ball bearings, mounting assembly and mounting cove,SD (AC Sliding gate motor) :SD 1010 Kit include 1 motor with control box, 2 magnetic limit switch, 1 base plate for installation, 1 pair release keys, 2 wireless remote, 1 manual switch, 1 pair photocell,Gear rack-12 mm, 12mmx1 meter galvanised steet rack with 3 stud,Motor installation charges (Commissioning and testing complete at site) complete all as specified and directedby Engineer-in-Charge |
| 15 | Surface excavation in soft and loose soil n.exc 30 cm deep and averaging 15 cm and getting out complete all as specified and directed by Engineer-in-Charge. |
| 16 | M&L for Brickwork with fly ash bricks old size bricks, straight or curved on plan to anyradius in half brick thick walls, built in CM 1:4 complete all as specified and directed by Engineer-in-Charge. |
| 17 | M & L for PCC (1:2:4) (Nominal mix) Type B-1 using 20mm graded stone aggregate for coping as in benching incl weathering slightly rounded, chamfered angles and finishing exposed surfaces even and smooth incl necessary formwork complete all as specified and directed by Engineer-in-Charge. |
| 18 | Hardcore of broken stone or boulders gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and as directed by Engineer-in-charge. |
| 19 | M&L forCement concrete type D2, 1:4:8 (40 graded crushed stone aggregate) as sub base for path, foundation, filling and mass concrete complete all as specified and as directed by Engineer-in-charge. |
| 20 | M&L for 75mm thick PCC 1:3:6, type C-2 using 40mm graded aggregate as in paving to floor and works complete all as specified and as directed by Engineer-in-charge. |
| 21 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in any kind of soil ,complete all as specified and directedNote : Manual excavation to be done. During excavation if any damage occured to existing cable any type/ water pipe line, it will be contractor responsibilty to get it repair and make functional by providing jointing kit etc without any extra cost. Contractor has to repair it within 24 hrs so that essential service can not be effected due to such damage complete all as specified and as directed by Engineer-in-charge. |
| 22 | Removing surplus excavated material from site not exceeding 50 mtrs from starting point and depositing where directed at level not exceeding 1.5 mtr above the starting pointall as specified and directed. |
| 23 | Returning filling in soft/loose soil, including, spreading levelling watering and well ramming in layers not exc. 25 cm complete all as specified and directed. |
| 24 | M&L providing sand cushioning with a layer of clean, dry, fine sand for protection of electric cable laid in trenches/ducts, punned down to desired thickness complete all as specified and directed.(Note: For payment purposes only punned down thickness of sand shall be measured ) |
| 25 | M & L for laying old size sub class ‘B’brick for PVC/ XLPE underground cable protection in trench,layedin the manner that width of brick to be peperndicular to the axis of cable ,over LT under ground cable complete all as specified and directed. |
| 26 | Material & labour for cutting of the bituminous/ Masti type road 60 cm depth and 45cm width for laying of LT cable and making good disturbed surfaces by filling with the existing materials to match with the existing road in all respect complete all as specified and directed.(Note: The tenderer shall verify the layers of road before quoting the rates in consultation with Eng-in-Charge, No claims of the tenderer shall be entertained in this regard at later stage.) |
| 27 | Material and labour for 40 mm dia galvanized iron tube light grade for cable protection, supporting to poles, plinth protections, road crossing, trenches, footpath etc, complete all as specified and directed including clamps, nut, bolt and washers. |
| 28 | Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured,3½ core with reduced neutral conductors (3½ core), nominal cross sectional area of main conductor 35 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed. |
| 29 | All as per item No 28 above but of size 16 sq mm 4 core |
| 30 | S & F LED street lights nominal power 70 Watt,operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen output of minimum 8400, lumen efficacy of minimum 120 lumens per watt, built-in integrated electronic LED driver, output open /short circuit protection, phase to phase protection, over voltage protection, surge voltage protection upto 4 KVs, protection grade IP 66, CRI greater than 80%, CW available CCT of 5700K, power factor of minimum 0.95, pressure die-cast aluminium alloy housing with polyester powder coated metallic silver finish after phosphochromate treatment, life span of minimum 50000 working hours with IK10 and L70including fixing at any height and including wiring using three core PVC insulated, PVC sheathed, flexible stranded copper conductor FR-LSH cables suitable for outdoor use, 1.5 sqmm as per IS 694: 2010 including taking out unserviceable complete all as specified and as directed. |
| 31 | Supply and fixing swaged & welded MS steel tubular poles, overall length 10.5 metre long incl 1.5 m moulded brecket double sided,complete specification as per 410-SP-31 ofIS: 2713-1980 complete with cast iron base plate, final taper plug, pole cap, bolts/nuts, screws/washes, painting, foundation with two coats of black bituminous paint through out internally and externally upto planting depth and two coasts of black and yellow alternate strips 30 cm each upto 1.2 mtr from the ground level. The remaining external position shall be painted with two coat of aluminium paint and one coat of cement based paint on PCC copping of pole including numbering of pole with black syenthic paint/ Stricker complete all as specified and as directed by Engr-in-Charge. |
| 32 | Supply,fixing, Installation , Testing and commissioning of LT Bus BarFeeder Piller Box outdoor type having provision of double door openings into two halves with rubber beadings cubicaltype ofsize 1.00x0.75x0.40 Mtr as directed by the manufacturer, made out of 3.15 mm CRCA sheet compartmentalized with rubber beadings, angle iron 40 x 40 x 5 mm shall be used for making legs/ frame, duly painted with powder coated internally and externally, including provn of Aluminium Busbar 400 Amps, including MCCB 100 A , 16 KA 3 Pole -01 No as incomer and MCCB 63 A, 16 kA MCCB - 2 nos as outgoing, timer switch for lighting control based on sunrise/sunset timings by lattitude/longitude settings and suitable insulators ,cable glands of required size as per site requirement for LT Cable entry. Including PCC Platform of suitable size PCC 1:2:4 all as directed by the Engineer-in-charge. |
| 33 | Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less\"than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point , including testing complete all as specified and as directed by Engr-in-Charge. |
| 34 | M&L for FRLS wiring in existing locatation for circuit alongwith earth wire 2 x 2.5 sqmm + 1 x 2.5 Sqmm copper cable PVC insulated multistranded from junction box to fitting connecting box etc.complete all as specified and as directed by Engr-in-Charge. (Two run of 2.5 Sqmm wire+01 Run of 2.5 Sqmm wire considered as one unit) |
| 35 | Supply and fixing digital timer switch with outdoor type weather proof IP66 enclosure, for auto on/off operation of street/garden light, 110-240 V AC having 25 ON/OFF operation complete with all accessories,making suitable fixing arrangement on pole complete all as specified and directed by Enge-in-Charge. |
| 36 | M&L for polycarbonate3 phase busbar system pole junction Box dust, weatherrain guarded IP66 cable entry and exit arrrangement with closing arrangementof size 255x355x122 mm with housing of 04 Nos 100 Amps aluminium bus bar fixed on porcelain insulator and connected of cables with lugs, nut bolts and washer including 06-16 Amps MCB SPN, \"C\" Curve all as specified and as directed. |