| 1 | Replacement of Pumpsets and Electric panel, cable and deepening of various scheme in UWSS Gangapur City under Summer contingency |
| 2 | Supply&Installationof3phaseISImarkedsubmersiblemotorpumpsetof three star or better rating of BEEand as per IS: 8034-2018 (pump) and IS 9283- 2013(motor)orasamendeduptodateofapprovedmakeoffollowing duty conditionwithrequiredaccessoriesincludingmakingconnectionsuitablefor tubewell/DCB.Thejobincludesloweringof motorpump,installationof complete fitting & accessories, jointing of electrical cables up to switch board, testingofsubmersiblepumpsetandinterconnectionuptowatermains, complete in all respect. |
| 3 | 9.3KW (12.5 HP) & head above 120 mtr. |
| 4 | Supply and Fixing of electric control feeder panel comprising of suitable rating MCCB , fully automatic star-delta starter, over load relay,ampere meter with CTs, volt meter, phase preventer, suitable starting capacitors, phase indicators, lighting arrangement etc complete suitable for three phase pump set. The panel should have space for energy meter ( supplied by DISCOM).All these equipments shall be housed by panel box made out from 18 gauge M.S. Sheet with powder coating. Panel should be ofminimum size 900 x 600 x 450 mm with Stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg’s length 18\" and double door including in built locking system.The legs should be embedded in M-15 cement concrete plat form. The size of CC platform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level. The panel should have opening of suitable size in front of space for energy meter with glass for meter reading. The operation of panel should be suitable for on 440 Volt AC Supply. |
| 5 | Above 10 HP and up to 15 HP |
| 6 | Supply & Fixing of ISI marked three core PVC flat submersible cableas per IS 694:1990 or amended up to date and conductor as per class 5 of IS 8130:1980 including making connection etc. |
| 7 | 3 core 6.0 Sq.mm |
| 8 | Providing & Lowering in tube well ISI marked GI Pipe medium duty (“B\" class), SteeltubeasperIS:1239oramendeduptodateandzinccoatingasperIS 4736,threadedanddoubleflanged(welded)onbothendsandtwonumber 25x3mm MS flat welded on both ends between pipe & flange, rubber washer &nut bolts etc. complete in all respect. |
| 9 | 50 mm dia |
| 10 | Providing,lowering, aligning,fixingin positionin pipeline,CID/FSluicevalvesstraight and pocket less body passage of approved make of following Pressure rating & dia complete, confirming to IS:14846 (amended up to date) and of following specifications: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand wheel of Grey cast iron of IS:210/ FG200Stem - AISI- 410 ,Body Seat ring, Wedge facing ring & Bushes - LTB2/ SS, Face to face dimensions as per IS 14846/2000 (amended up to date) ,Epoxy ( Non-Toxic- suitable for drinking water) applied inside and outside,Flanges Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367/ CS/ galvanised steelInsertion rubber of black EPDM 6mm thick . Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work. |
| 11 | Manually Operated CI Sluice valve of Class PN-1.0 |
| 12 | 150 mm HW |
| 13 | 200 mm HW |
| 14 | De-jointingandremovingofalreadylaid CI/DIpipesoffollowing diameters in excavated trenches with care, without damaging pipes, CID joints, valves, specials etc. and other materials and then refilling of soil after de-laying and de-jointing of pipelines with proper compaction and disposing of all surplus soil as directed with in a lead of 30 mtr. This also include stacking the pipes with care and transporting the same to div./sub div. store or as directed by EIC with in the division. (Rates are Exclusive of Earth Work) |
| 15 | 200 mm |
| 16 | Laying, Jointing, Testing and Commissioningof Ductile Iron (DI) Pipes of any class in assorted length with specials, valves etc. including local handling and transportation from PHED store and then refilling of soil with proper compaction and disposing of all surplus soilas directed with in a lead of 30 mtr as per satisfaction of EIC. (Rates are Exclusive of Earth Work and jointing materials) |
| 17 | 200 mm |
| 18 | Providing, lowering, laying in trenches, aligning, fixing in position and jointingDuctileIron(DI)ISI markedK-7 gradeS&Spipesas per IS:8329-2000 (amendedup todate),withinternalcementmortar liningsuitable forpotablewaterwithrubberring (EPDM) jointsas perIS:5382-1985includingalltaxes(Centralandlocal), transportation and freight charges, inspection charges, loading/ unloadingcharges, includingcostoflabourandmaterial,specials (Tee,bendetc.)satisfactoryhydraulictesting,disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-charge. (excluding earth work)Note:Providingandfixingofallrequisitespecialsasperdrawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately. |
| 19 | 200 mm |
| 20 | Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches of required width and gradient for laying and jointing of pipe line including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 Mtr. including taking out the excavated soil, and then returning the soil as required in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and disposal of surplus excavated soil as directed within a lead of 50 Mtr. including required all safety provisions etc.:All kinds of soil |
| 21 | Deepening of existing tube well by DTH system beyond existing depth up to 100 mtr. and above in all type of rocks including flushing of tube well and obtaining sand free water. |
| 22 | Nominal bore 200 mm dia. |
| 23 | Providing, installation, testing and commissioning of Centrifugal Monoblock pump set conforming to IS 9079 , 2 pole motor operating at synchronised speed of 3000 RPM with requisite MOC impeller, priming funnel, cock, suitable flanges at suction and delivery side. Pump shall have common shaft for pump and motor. Motor shall be suitable for working on 415 V ± 10%, 3 Ph, 50 Hz A.C. Supply. Motor shall be TEFC type and Pump set shall be suitable for working at various discharge and head requirements as per scope of work. Pump shall be erected onC.C. foundation / cross channels / RSJ frame block with suitable foundation bolts grouted in C.C. foundation block etc. complete in all respect as perspecification, scope of work and direction of Engineer in Charge of following power rating, suitable for prescribed duty conditions mentioned in TD. |
| 24 | Centrifugal Monoblock Pump set (Double Stage) |
| 25 | 15.0 KW (20.0 HP) |
| 26 | STAR DELTA STARTER 15.0 KW (20.0 HP) : For 2 motors (1 W+ 1S) I/C- MCCB 100A TPN 25 KA With T/M Based Over Current & Short Circuit Protection (1), Spreaders (2),Extended Rotary Handle (1) , Analog Voltmeter 96*96mm ( 0-500V ) (1), Volt Selector Switch (1) , Analog Ammeter 96*96mm ( 0-60A ) (1), Amp. Selector Switch (1), C. T. 100/5A CL 1.0 5VA (3) , Indicating Lights ( Red-1, Yellow -1) (2), Indicating Lights ( Blue - 1 ) (1), Control MCB 6A SP 10 KA C Curve (3) and O/G- MCCB 63A TPN 25 KA With T/M Based Over Current & Short Circuit Protection (2), Power Cont 32A TP AC3 Duty(2), 2 NO+2 NC Aux. Block(2), Thermal Overload Relay (12- 18A )(2), Control MCB 6A SP 10 KA C Curve (2), Single Phase Priventer (2), Indicating Lights (Red- 1, Green - 1, Amber-1)(6), Push Button 22.5 ( Red - 1, Green - 1 )(4), Selector Switch 1 Pole, 2 Way (2), Capacitor 440VAC Heavy Duty MPP Type 7.5Kvar (2), S/D Timer(2) |
| 27 | 15.0 KW (20.0 HP) |
| 28 | Providing and fixing at site with necessary packing, Horizontal Centrifugal SplitCasting pumps with 4 pole induction motor operating at syncronised speed of speed 1500RPM as per IS 12615: 2011 or amended up to date , CI casing and casing ring, SS 316impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundationbolts, Cement concrete foundation etc. complete with all respect as per the specification andscope of work and direction of Engineer in Charge of following range of duty conditions.Note: Duty condition of required pump shall also be mentioned in BoQ. |
| 29 | Discharge 41 t0 50 LPS and head 61 to 70 M |
| 30 | SITC of Soft Starters with panel supplied by manufacturer conforming to applicable standards with logic inputs & outputs, relay outputs and analogue outputs, plug in IO connections, display of electrical parameters, state of load & operating time, RS 485 serial link for connections to Modbus. |
| 31 | 45 KW |