| 1 | Comprehensive routine maintenance of Window / Split type ACs units of 1.0 / 1.5 / 2.0 TR capacity units of different makes installedat various locations at NCC Bhawan, Asha Kiran, Pension office, Circle office, Sub Division office, Mukarba Chowk, Delhi,i/c repairing / replacement of remote, capacitor running type, all types of defective parts, gun metal taps, electronic parts ,float valve assembly excluding topping up of refrigerant in compressor, refrigeration pipe, PCB for indoor/outdoor complete as per terms and conditions, and timing as per direction of Engineer -in- charge & wherever reqd. (Note:- i) During the period of Summer Season & duration as specified by the Engineer-in-Charge ii) Maintaining of Complaints will be recorded by the agency in the AC Task/Complaint register) (150 Units X 8 Months = 1200 Units) |
| 2 | Comprehensive running maintenance of capacity of 100/150 litres different makes water cooler units installed at various locations at NCC Bhawan, Asha Kiran, Pension office, Circle office, Sub Division office, Mukarba Chowk, Delhi including repairing/ replacement of condenser motor, compressor & all type of defective parts such as Gun metal taps, float valve assembly, Supplying and charging of refrigerant gas in case of leakage including condenser coil & cooling coil etc complete as per terms & conditions attached. To depute following staff : a) Water Cooler Mechanic - 1 No. (9:00 AM to 6:00 PM) b) Khallasi - 1 No. (9:00 AM to 6:00 PM) 30 x 8 months = 240 Units for 8 months |
| 3 | Complete servicing of WTAC/STAC/unit of different capacity including dismantling the AC from its existing position at various locations/grill/window cutting, washing with High pressure water spray electric machine coil cleaning with D- Scaling Chemical, drying with air blower ,oiling, greasing, of blower fans cleaning of evaporative and condensing coil with suitable chemical like coil cleaner, as required in its existing position complete as per direction of Engineer -in- charge & wherever reqd.a) Window type AC unit/Split type AC of 1.5 TR / 2.0 TR / 3.0 TR capacity |
| 4 | b) Water coolers of capacities 100/150 Ltrs |
| 5 | Replacement of printed circuitassembly (PCB) of the Existing indoor Unit Split/WTAC AC 1.5/2.0 TR Complete with connection & Testing etc. as required at sidein the machine as per requirement & approval of the Engineer-in-Charge. (Dismantled material shall be retained by the contractor) |
| 6 | Replacement of printed circuit assembly (PCB) of the Existing Outdoor Unit Split AC/WTAC 1.5/2.0 TR with connection & Testing etc. as required at sidein the machine as per requirement & approval of the Engineer-in-Charge. (Dismantled material shall be retained by the contractor) |
| 7 | Repairing of PCB card of 1.5/2 TR capacity WTAC/split type AC unit having following capacity after dismantling the defective card from AC unit & refixing the same i/c connections of electrical wires/cables & thimbles connection, testing & commissioning etc. complete as required. |
| 8 | Supplying & charging of Refrigerant gas (R-22/32/refrigerant suitable as per requirement of AC unit) in the following type capacity AC units i/c leakage testing removing the leakage, pressure testing, flushing the complete system, vacuumizing and gas charging complete as required. (Note:- Quantity of gas filled shall be entered in Consumption Register maintained by the agency)a) In 1.5 TR STAC capacity |
| 9 | b) In 2.0 TR STAC capacity |
| 10 | Supplying & Fixing of hard drawn copper suction and discharge refrigeration pipe of size 5/8\"and 3/8\" suitable for 2 TR STAC duly insulated by nitrile rubber, covered with MS pipe for safety of the pipe along with necessary support, clamps, brackets as required as per site requirement. |
| 11 | Supplying & Fixing of hard drawn copper suction and discharge refrigeration pipe of size 1/2\"and 1/4\" suitable for 1.5 TR STAC duly insulated by nitrile rubber, covererd with MS pipe for safety of the pipe along with necessary support,clamps,brackets as required as per site requirement. |
| 12 | Supplying of following accessories for the existing 1.5 TR/ 2 TR. capacity WTAC / STAC unit, using existing man power for replacement on day to day maintenance work:a) 15 Amp 3 Pin plug Top (ISI Marked) |
| 13 | b) 3 core PVC insulated PVC sheathed copper wire 2.5 Sq.mm copper flexible |
| 14 | Supplying , Installation , testing and commissioning of 2.0 Tr Capacity Outdoor Unit inverter / non inverter STAC suitable for operation on 230V , 50Hz Single phase AC Supply , Capable of performing cooling , complete with condenser coil , compressor , valve set fitting etc complete as reqd. |
| 15 | Supplying and replacement of following parts including removal of un-serveceable part, electrical connections & re-installation the same, testing, commissioning etc. as required. (Labour & gas charges already included in below mentioned item.)a) Rotary Compressor 1.5 Ton |
| 16 | b)Rotary Compressor 2 Ton |
| 17 | c) Reciprocating compressor 1.5 Ton |
| 18 | d) Reciprocating compressor 2.0 Ton |
| 19 | e) Outdoorfanmotor 1.5 Ton |
| 20 | f) Out door fan motor 2 Ton |
| 21 | g) Indoor fan motor 1.5 Ton |
| 22 | i) Cooling coil copper - 1.5 Ton for WTAC/STAC |
| 23 | j) Condenser coil copper- 1.5/2.00 ton for WTAC/STAC |
| 24 | k) AC Indoor Unit |
| 25 | l) Remote Control + PCB Kit |
| 26 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, “C” curve including connections, painting etc. as required. |
| 27 | Dismantling of existing suitable 1.5 TR/2.0 TR capacity WTAC unit & both indoor & outdoor in case of STAC etc. with equipments complete as reqd. |
| 28 | Re-Installation of STAC Unit existing suitable 1.5 TR/2.0 TR capacity STAC unit & both indoor & outdoor in case of STAC etc. with equipments complete as reqd. |
| 29 | Credit of buy back of dismantled materialsa) Copper Pipe/Cables |
| 30 | b) AC Outdoor Unit inverter/non inverter |
| 31 | c) Plug Top |
| 32 | a) Rotary Compressor 1.5 Ton |
| 33 | b)Rotary Compressor 2 Ton |
| 34 | c) Reciprocating compressor 1.5 Ton |
| 35 | d) Reciprocating compressor 2.0 Ton |
| 36 | e) Outdoorfanmotor 1.5 Ton |
| 37 | f) Out door fan motor 2 Ton |
| 38 | g) Indoor fan motor 1.5 Ton |
| 39 | i) Cooling coil copper - 1.5 Ton for WTAC/STAC |
| 40 | j) Condenser coil copper- 1.5/2.00 ton for WTAC/STAC |
| 41 | k) AC Indoor Unit |