| 1 | S&F IN REPAIR Air termination, single pointed aluminium rod 12mm dia and 300mm long, with and including taking out existing old unserviceable air termination rod of any description, complete all as specified. |
| 2 | S&F IN REPAIR Air termination, single pointed copper rod 12mm dia and 300mm long, with and including taking out existing old unserviceable air termination rod of any description, complete all as specified. |
| 3 | S&F IN REPAIR Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screwincluding taking out existing old unserviceable test point of any description, complete all as specified and as directed. |
| 4 | S&F IN REPAIR Aluminium strip 25mm x 3.15mm with saddles and fixing screws etc., for roof conductors and down conductors above ground, with and including taking out existing old unserviceable strip of any description, complete all as specified and as directed. |
| 5 | S&F IN REPAIR Copper strip 25mm x 3.15mm with proceline insulator and fixing screws etc., for roof conductors and down conductors above ground, with and including taking out existing old unserviceable strip of any description, complete all as specified and as directed. |
| 6 | S&F IN REPAIR Aluminium strip 32mm x 6mm with saddles and fixing screws etc., for roof conductors and down conductors above ground, with and including taking out existing old unserviceable strip of any description, complete all as specified and as directed. |
| 7 | S&F IN REPAIR Copper strip 32mm x 6mm with proceline insulator and fixing screws etc., for roof conductors and down conductors above ground, with and including taking out existing old unserviceable strip of any description, complete all as specified and as directed. |
| 8 | M&L for Copper strip size 20mm x 3mm as earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe through wall /floor / roof or fixed to poles or any other indicated situation for loop earthing etc. as required, with and including taking out existing old unserviceable strip of any description, complete all as specified and as directed.Note:- (i) Excavation & earth work shall be measured and paid separately under relevant items in this BOQ.(ii) Cutting holes in the wall and making good with cement plaster / mortar along with distemper / white wash is deemed to be included in the rate quoted.(iii) Cost of Insulators required for fixing of strip including nuts and bolts is also included in the unit rate quoted. |
| 9 | All all as per Serial Item No. 8 here in before but for Galvanised Iron Strip of size 25mm x 4mm. |
| 10 | All all as per Serial Item No. 8 here in before but for Galvanised Iron Strip of size 32mm x 6mm. |
| 11 | All all as per Serial Item No. 8 here in before but for Aluminium Strip of size 25mm x 3mm. |
| 12 | S&F IN REPAIR Epoxy based insulator 40mm height for fixing GI strip/copper strip on wall / ceiling / floor / poles etc., including taking out existing old unservicable insulator of any description, complete all as specified and as directed.Note: This item is considered for replacement of insulators other than those catered for unit rate of serial item No. 5&7 here-in-before. |
| 13 | S&F IN REPAIR High density polyethylene (HDPE) pipe of 40mm bore dia, pressure rating 6 kgf/cm2 laid in trenches with and including tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc., complete all as specified and as directed. |
| 14 | S&F IN REPAIR Galvanised steel tube 40mm bore medium grade with all fittings, laid in trenches / fixed to walls/poles with suitable clamps, nuts, bolts etc for passing of earth continuity conductor including necessary welding where required, complete all as specified and as directed. |
| 15 | S&F IN REPAIR Galvanised steel tube 25mm bore medium grade with all fittings, laid in trenches / fixed to walls/poles with suitable clamps, nuts, bolts etc for passing of earth continuity conductor including necessary welding where required, complete all as specified and as directed. |
| 16 | S&F IN REPAIR Galvanised steel tube 20mm bore medium grade with all fittings, laid in trenches / fixed to walls/poles with suitable clamps, nuts, bolts etc for passing of earth continuity conductor including necessary welding where required, complete all as specified and as directed. |
| 17 | S&F IN REPAIR Galvanised steel tube 15mm bore medium grade with all fittings, laid in trenches / fixed to walls/poles with suitable clamps, nuts, bolts etc for passing of earth continuity conductor including necessary welding where required, complete all as specified and as directed. |
| 18 | Taking down / out existing copper / GI strip as earth continuity conductor fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles etc,with and including straightening the twisted / bent up portion of strip and re-fixing in position, with required welding / soldering of earth continuity conductor, complete all as specified and as directed. |
| 19 | M&L forEarthing complete with GI earth plate electrode 600mm x 600mm x 6mm thick, burried directly in ground in vertical position, earth pit not less than 2.25 Metre deep below GL with top edge of the plate not less than 1.5 Metre below GL connetced with GI earthing strip of size 25mm x 4mm by means of nuts, bolts, check nuts and washers made of GI or steel earthing lead protected by GI pipe 40mm bore (medium grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore GI pipe (light grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessaryexcavation & earth work, returning filling and removal of surplus earth upto a distance not exceeding 50 Mtr etc all as shown on electrical plate No. 3 ofMES Schedule Part-I complete to obtain less than 1 Ohm earth resistance, fiaxed in repairsincluding taking out existing old unservicable earthing materials of any description, complete all as specified and as directed..NOTE : Cost of this items includes the scope of earth work charcoal, salt, PCC, RCC pit cover and GI strip upto 7.5metre. |
| 20 | All all as per Serial Item No. 19 here in before but for earthing with GI Strip of size 32mm x 6mm. |
| 21 | All all as per Serial Item No. 19 here in before but for earthing with GI Earth Lead Wire of size 4mm dia. |
| 22 | M&L for Earthing complete with copper earth plate of size 600mm x 600mm x 3.15mm thick, burried directly in ground in vertical position, earth pit not less than 2.25Mtr deep below GL with top edge of the plate not less than 1.5Mtr below GL with copper earthing strip of size 20mm x 3mm thick by means of brazing between copper strip and earth plate min 45cm in vertical length, jointing copper strip by brazing, protecting copper stripwith GI pipe 40mm bore (medium grade) up to GL and 40mm dia HDPE pipe up to test point, funnel with 20mm bore GI (light grade) pipe, wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) up to 90cm all around earth plate & filled with 60cm thick Tibba sand and 2nd layer with 30cm of Magnesium sulphate powder (compact thickness ), 3rd layer with tibba sand up to GL, with concrete earth pit in PCC (1:3:6) type C-1, 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways & handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exc 50Mtr, all as shown on electrical plate No. 3 ofMES Schedule Part-I, complete to obtain less than 2Ohm earth resistance value, cincluding taking out existing old u/s materials of any description, complete all as specified and as directed. NOTE : Electrical Plate No. 3 referred above is mainly for earth chamber & cost shall includes the scope of making test point terminal block complete. |
| 23 | S&F IN REPAIR PVC insulated multistranded copper conductor cable of size 10 sqmm single core 1100 volts grade, with and including copper lugs/thimbles on both side fixed from common Earth point to neutral point at main switch / earth dolly with nuts, bolts, washers, including taking out existing old u/s cable of any description, complete all as specified and as directed. |
| 24 | M&L forBrazing of copperearth continuity conductor of size 32mmx6mm / 25mmx3mm including cleaning the conductor and replacement of nuts, bolts for better earthing and connectivity and fixing at its original position complete all as specified and as directed. Note: Contractor shall make arrangements of gas cylinder and T&P for brazing and cost is deemed to be included in the unit rate. |
| 25 | M&L for testing of copper / GI earthing by 3 Pole Fall of potential method at scattered area under GE office by pouring water and adding charcoal & salt solution on required intervals to maintain earth resistance as required complete, submitting individual earth resistance results, carrying out earth test of individual earth, complete all as specified and as directed. Note: (i) Cost of tools and materials required to perform the test is deemed to be included in the rate quoted.(ii) Contractor will arrange water bowser for watering at his own end.(iii) Water shall be issued for filling from MES Pump House.(iv) This item will not be operated in Monsoon period.(v) Funnel, bucket for pouring of water shall be arranged by the contractor at his own soured.(vi) Necessary Earth work & excavation and Common salt & charcoal shall be measured and paid separately.(vii) Contractor shall submit user certificate duly signed by JE, Engineer-in-Charge and User before claiming payment. |
| 26 | Supply only Common salt as approved by Engineer-in-Charge, complete all as specified. |
| 27 | Supply only Charcoal dust / breeze as approved by Engineer-in-Charge, complete all as specified. |
| 28 | Excavation in trenches not exceeding 1.5m wide and not exceeding 10 Sq.m on plan area and not exceeding 1.5m deep in soft/loose soil, for foundation etc., or for laying of cable/ GI Pipe, shafts, wells, cesspits, manholes, pier holes, etc., complete all as specified. |
| 29 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick of excavated soil, as in soft/loose soil, complete all as specified. Note: A deduction of 10% shall be made from total computed volume of filling to cater in bulk irrespective of machinery used for ramming. |
| 30 | Removal of excavated material [Soil] to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point, complete all as specified. |
| 31 | M&L for Testing of existing seriviceable earthing located at diffierent locations after disconnecting from test point by using suitable earth tester, measuring the earth values in ohms and writing the values on earth chamber in bold white colour letters not exc 2cm height on the black back ground such as tested on, due date of testing eg-EP No-01, ER- Ohms& Date of testing : DD/MM/YYYY and recording of test results in prescribed format, complete all as specified and as directed.Note:- (i)The test results shall be kept on record duly signed by contractor, JE/EM and user concerned.(ii) This item shall be not be operated for earthings considered against item No. 25 here in before. |
| 32 | M&L for Repair to Earth pit chamber of size 300mm x 300 mm (internal dimensions) and wall thickness 120mm with PCC 1:3:6 type C-1 using 20mm graded stone aggregate with and including replacing RCC cover 50mm thick in cement concrete 1:2:4 type B-1 reinforced with 8mm dia MS round bars @ 15 cm c/c both ways and external finishes, complete all as specified andas directed. |
| 33 | S&F IN REPAIR Precast RCC earth pit cover of size 540mm x 540mm x 50mm in cement concrete 1:2:4 type B-1 duly reinforced with 8mm dia MS round bars @ 15 cm c/c both ways including MS handle, complete all as specified and as directed. |
| 34 | M&L for Painting to earthing chamber with two coats of synthetic enamel paint in red / yellow colour and writing letters in bold black colour letters 1.5cm height such as \"Chem Pit-1, Conventional Pit-5\" etc., as directed by Engineer-in-Charge, complete all as specified andas directed. |
| 35 | M&L for Circuit / Sub main wiring with two runs of 1.5Sqmm PVC FRLSH insulated copper conductor cable, single core multi stranded 1100Volt along with one run of 1.5Sqmm as earth wire, drawn through and including rigid PVC conduit of suitable size (minimum 20mm dia), concealed /surface type, medium grade as per IS 9537 (Part 1-1983) with conduit accessories, including taking down old submain wiring of any type, complete all as specified and as directed. Note: Two runs of cable, one run of earth wire and one run of conduit shall be measured as one unit. |
| 36 | M&L for Circuit / Sub main wiring with two runs of 2.5Sqmm PVC FRLSH insulated copper conductor cable, single core multi stranded 1100Volt along with one run of 2.5Sqmm as earth wire, drawn through and including rigid PVC conduit of suitable size (minimum 20mm dia), concealed /surface type, medium grade as per IS 9537 (Part 1-1983) with conduit accessories, including taking down old submain wiring of any type, complete all as specified and as directed. Note: Two runs of cable, one run of earth wire and one run of conduit shall be measured as one unit. |
| 37 | M&L for Circuit / Sub main wiring with two runs of 4.0Sqmm PVC FRLSH insulated copper conductor cable, single core multi stranded 1100Volt along with one run of 4.0Sqmm as earth wire, drawn through and including rigid PVC conduit of suitable size (minimum 20mm dia), concealed /surface type, medium grade as per IS 9537 (Part 1-1983) with conduit accessories, including taking down old submain wiring of any type, complete all as specified and as directed. Note: Two runs of cable, one run of earth wire and one run of conduit shall be measured as one unit. |
| 38 | S&F LED Street light fitting 25Watt, 230volts, >100lum/W, beam angle of ǿ 120°, AC outdoor type with high Pressure Die Cast aluminium Housing and heat resistant toughened glass with frame complete with LED lamp, driver with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection, surge protection 10KV with all accessories, including taking down old u/s SV/MV type street light fitting from pole of any description, complete all as specified and as directed. |
| 39 | S&F LED Street light fitting 35Watt, 230volts, >100lum/W, beam angle of ǿ 120°, AC outdoor type with high Pressure Die Cast aluminium Housing and heat resistant toughened glass with frame complete with LED lamp, driver with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection, surge protection 10KV with all accessories, including taking down old u/s SV/MV type street light fitting from pole of any description, complete all as specified and as directed. |
| 40 | S&F IN REPAIR, Factory made epoxy powder coated sheet metal enclosure for DBs (Fixed flush to the wall), SPN, 415 volt, 4Way, double door, IP-42 protection with 200 Amp rated copper bus bar 415Volt, and 1.5 Sq. mm copper PVC sheathed cable for earth continuity and suitable for having MCB’s, complete all as specified. |
| 41 | S&F IN REPAIR MCB SPN 40 to 63Amp, 10kA, 230Volt, C curve with necessary connecting up in MCB DB, testing and commissioning, complete all as specified and as directed. |
| 42 | S&F IN REPAIR MCB SP 10 to 32Amp, 10kA, 230Volt, C curve with necessary connecting up in MCB DB, testing and commissioning, complete all as specified and as directed. |
| 43 | S&F IN REPAIR LED light fitting 1X10watt, surface mounted type, Oval bulk head edge-lit LED fitting, high brightness LEDs 6000K, 220Volt, >100 lum/W, PF>0.95, AC decorative box type with driver, holder, including LED lamp, fixed on wooden board with sunmica top, and connecting up with three core flexible copper conductor cable of suitable size from ceiling rose, complete all as specified. Make: Cat No. LBHP - 10 - CDL of CG / Cat No. ENDURA RUGBY NEO N-IP65 of Havells or Equivalent make as specified here -in-after |
| 44 | S&F IN REPAIR LED Post Top lantern 20Watt, 230 volts, >100lum/W, with decorative post top for beam angle of ǿ 360°, AC outdoor type with high Pressure Die Cast aluminum Housing and heat resistant toughened glass with frame complete with LED lamp, driver with impact and corrosion resistant complete with IP 65/66 protection, complete all as specified and as directed. Make: Cat Part No. LHDC11126099 of Havells or Equivalent make as specified here-in-after. |
| 45 | S&F IN REPAIR LED Post Top lantern 40Watt, 230 volts, >100lum/W, with decorative post top for beam angle of ǿ 360°, AC outdoor type with high Pressure Die Cast aluminum Housing and heat resistant toughened glass with frame complete with LED lamp, driver with impact and corrosion resistant complete with IP 65/66 protection, complete all as specified and as directed. Make: Cat Part No. LP02-501-XXX-57-XX of Wipro or Equivalent make as specified here-in-after. |
| 46 | S&F IN REPAIR Bollard light LED type 09Watt, 230 volts, >100lum/W, with decorative aluminium bollard with integrated driver with decorative cylindrical / rectangular shape, out door type with LED lamp, driver with impact and corrosion resistant complete with IP 65/66 protection, complete all as specified and as directed. Make: Cat Part No. CRLA11008HP57-05 of Wipro or Equivalent make as specified here-in-after. |
| 47 | M&Lfor Checking / inspection of non functional / non working geyser any capacity / make in existing location for identifying the defects/faults in geyser/wiring/fault from DB etc all as per complaint obtained from MES service centre, complete all as specified and as directed.Notes :-(i) All defects notified shall be recorded in pucca bound register and shall be certified by the Engineer-in-charge.(ii) TheContracor shall provide the complaint slip containing 100 pages in duplicate (in single colour) of size 5 inch x 8 inch properly binded and printed with their Firm Name and Telephone numbers as per sample and directed by Engr-in-Charge. |
| 48 | S&F in repair Gun metal check valve / non return valve 15 mm dia suitable for Geyser of any make/capacity . complete all as specified and as directed. |
| 49 | S&F in repair Gun metal check valve / non return valve 20mm dia suitable for Geyser of any make/capacity . complete all as specified and as directed. |
| 50 | S&F in repair Gun metal check valve / non return valve 25mm dia suitable for Geyser of any make/capacity . complete all as specified and as directed. |
| 51 | S&F in repair Pressure Release valve 15mm dia suitable for Geyser of any make/capacity, complete all as specified and as directed. |
| 52 | S&F in repair Pressure Release valve 20mm dia suitable for Geyser of any make/capacity, complete all as specified and as directed. |
| 53 | S&F in repair Geyser Heating Element 2000 watts, suitable for Geyser of any make/capacity, complete all as specified and as directed. |
| 54 | S&F in repair Geyser Heating Element 1500 watts, suitable for Geyser of any make/capacity, complete all as specified and as directed. |
| 55 | S&F in repair Thermostat suitable for geyser of capacity 25 to 50 litres and range 25 to 75 degree centigrade and cut off at 70 degree centigrade, complete all as specified and as directed. |
| 56 | S&F IN REPAIR FRLSH PVC insulated sheathed, multi standard, copper conductor cable of size 3.0 core x 2.5Sqmm, 1100 volts grade and multi stranded 1100 Volt grade confirming to IS 694: 1977, for electric connection, complete all as specified and as directed. |
| 57 | S&F IN REPAIR FRLSH PVC insulated sheathed, multi standard, copper conductor cable of size 3.0 core x 4.0Sqmm, 1100 volts grade and multi stranded 1100 Volt grade confirming to IS 694: 1977, for electric connection, complete all as specified and as directed. |
| 58 | S&F IN REPAIR Indicator lamp square/ round/ rectangular type, green/ red, suitable for geysers of25/ 50 litres capacity, complete all as specified and as directed. |
| 59 | S&F IN REPAIR Heating plate assembly with water inlet & outlet, rubber gasket, nuts and bolts and washers of required size suitable for 50 Litre Capacity Geyser of any type and make, complete all as specified and as directed. |
| 60 | S&F IN REPAIR Heating plate assembly with water inlet & outlet, rubber gasket, nuts and bolts and washers of required size suitable for 25 Litre Capacity Geyser of any type and make, complete all as specified and as directed. |
| 61 | S&F IN REPAIR Glass wool of stdard qualityfor geyser vessel of any size and capacity of 25 Litres, complete all as specified and as directed. |
| 62 | S&F IN REPAIR Glass wool of stdard qualityfor geyser vessel of any size and capacity of 50 Litres, complete all as specified and as directed. |
| 63 | S&F IN REPAIR Mild steel holding / anchor bolts and nuts machine made of size 10cm to 15cm long and dia of bolt 10mm to 15mm, complete all as specified and as directed. Note :- Anchor bolt shall be grouted with hammer drill only. |
| 64 | S&F IN REPAIR Dead nut / Safety plug of brass as per sample suitable for Geyser of any capacity/makecomplete all as specified and as directed. |
| 65 | S&F IN REPAIR Inner copper tank of geyser capacity 25 litres of any type and make to match the existing size, gaugeand shape of inner tank of Geyser installed at sitecomplete all as specified and as directed. |
| 66 | S&F IN REPAIR Inner copper tank of geyser capacity 50 litres of any type and make to match the existing size, gaugeand shape of inner tank of Geyser installed at sitecomplete all as specified and as directed. |
| 67 | S&F IN REPAIR Outer tank of geyser made out of aluminium sheet of existing gauge, shape suitable for inner tank 25 litres capacity geyser of any make complete all as specified and as directed. |
| 68 | S&F IN REPAIR Outer tank of geyser made out of aluminium sheet of existing gauge, shape suitable for inner tank 50 litres capacity geyser of any make complete all as specified and as directed. |
| 69 | S&F IN REPAIR Socket outlet (enclosure type) suitable for geyser of any type and capacity, complete all as specified and as directed. |
| 70 | S&F IN REPAIR Metal plug top 15/16Amp (enclosure type) suitable for geyser of any type and capacity, complete all as specified and as directed. |
| 71 | S&F IN REPAIR Hot water PVC connection of 15mm bore heavy duty, length upto 45cm with brass nut joints and washers at both endscomplete all as specified and as directed. |
| 72 | S&F IN REPAIR PVC connection, 15mm dia 600mm long with brass nuts suitable for hot/ cold water supply complete all as specified and as directed. |
| 73 | S&F IN REPAIR Sheet metal enclosure with socket plug top and MCBs single pole and neutral enclosure with a 2 pin and earth plug and socket complete with one SPNMCB of 20 Amp rating 240Volt, complete all as specified and as directed. |
| 74 | M&Lfor Soldering / brazing / welding work to stop leakage and other job connected work be required in connection with making geyser functional, complete all as specified and as directed. |
| 75 | S&F IN REPAIR Bottom split inspection cover for geyser of capacity 25 litres of any make & model, complete all as specified and as directed. |
| 76 | S&F IN REPAIR Bottom split inspection cover for geyser of capacity 50 litres of any make & model, complete all as specified and as directed. |
| 77 | S&F IN REPAIR 16mm outer dia CPVC pipes SDR 11 and Plain CPVC SDR 11 Fittings, fixed to walls / ceiling or laying in floors, complete all as specified andas directed. |
| 78 | S&F IN REPAIR 20mm outer dia CPVC pipes SDR 11 and Plain CPVC SDR 11 Fittings, fixed to walls / ceiling or laying in floors, complete all as specified andas directed. |
| 79 | S&F IN REPAIR Fancy type Stop valve of 15 mm dia, cast copper alloy, chromium plated, screwed down, high pressure, with crutch or butterfly handle, screwed down, high pressure, screwed both ends for iron pipe, complete all as specified and as directed. |
| 80 | S&F IN REPAIR Fancy type Stop valve of 20 mm dia, cast copper alloy, chromium plated, screwed down, high pressure, with crutch or butterfly handle, screwed down, high pressure, screwed both ends for iron pipe, complete all as specified and as directed. |
| 81 | S&F IN REPAIR Fancy type Bib tap of 15mm dia cast copper alloy, chromium plated, screwed down, high pressure, with crutch or butterfly handle, screwed down, high pressure,, screwed both ends for iron pipe,complete all as specified andas directed. |
| 82 | S&F IN REPAIR Fancy type Bib tap of 20mm dia cast copper alloy, chromium plated, screwed down, high pressure, with crutch or butterfly handle, screwed down, high pressure,, screwed both ends for iron pipe,complete all as specified andas directed. |
| 83 | S&F Electric water heater, storage type ABS complete with shock proofbody andmild steel with glass lined coating inner tank and Glass lined coated incoloy heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostat, NRV, connector piece etcfixed to wall with suitable bolts and nuts duly grouted including re-connecting the electrical and water supply connection and testing, complete all as specified and as directed. |
| 84 | S&F Electric water heater, storage type ABS complete with shock proofbody andmild steel with glass lined coating inner tank and Glass lined coated incoloy heating element upto 2 KW capacity 50 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostat, NRV, connector piece etcfixed to wall with suitable bolts and nuts duly grouted including re-connecting the electrical and water supply connection and testing, complete all as specified and as directed. |
| 85 | Taking down carefully storage type electric water heater (geyser) of any type and make, 25/ 50 litres capacity including disconnecting all electrical and water supply connections, carrying out all necessary servicing such as de-scaling the inner container, heating element etc., with and including diluted hydrochloric acid andcleaning thoroughly, filling the inner container with water and arresting the leakage by bracing, welding, re-assembling the geyser, fixed to wall with suitable bolts and nuts duly grouted including re-connecting the electrical and water supply connections and testing, complete all as specified and as directed. |
| 86 | M&L for Spray painting with two coats of synthetic enamel paint of approved colour over a coat of primer to geysers of capacity 25 litres including complete removal of existing paint and necessary preparation of surfaces and writing the MES number 25mm size with black enamel paint, complete all as specified and as directed. |
| 87 | M&L for Spray painting with two coats of synthetic enamel paint of approved colour over a coat of primer to geysers of capacity 50 litres including complete removal of existing paint and necessary preparation of surfaces and writing the MES number 25mm size with black enamel paint, complete all as specified and as directed. |
| 88 | S&F uPVC pipes of pressure rating 10 kgf/cm2 of size 15mm bore dia, laid in trench or fixed on walls, ceilings or in floors including taking down old unserviceable UPVC pipe of any description, complete all as specified and as directed. |
| 89 | S&F IN REPAIR 500 litres capacity Rotational moulded polyethylene (HDPE) water storage tanks, \"ISI\" marked, cylindrical, vertical with closed top conformingto IS 12701-1989 having two layers wall construction with manhole lid and suitable locking arrangement including making holes for inlet, outlet and over flow pipes, hoisted, fixed in position and testing complete including Dismantling water tanksof any description from the existing staging/ Building after disconnecting and dismantling of all existing pipe line connections carefully, complete all as specified and as directed. |
| 90 | All as per Serial Item No. 89 here in before but for 1000 liters tank capacity. |
| 91 | All as per Serial Item No. 89 here in before but for 2000 liters tank capacity. |
| 92 | S&F IN REPAIR PVC water Tank cover (ISI MARKED) of any capacity with hinges, clamps, bolt pin etc., complete all as specified and as directed. |
| 93 | S&F IN REPAIR 20mm dia PTMT ball valves high pressure (minimum weight 210 grams) with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed, complete all as specified and directed. |
| 94 | S&F IN REPAIR 25mm dia PTMT ball valves high pressure (minimum weight 210 grams) with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed, complete all as specified and directed. |
| 95 | S&F IN REPAIR Solar heating element 3000Watt suitable for any type or size and make of solar heater, complete all as specified and directed. |
| 96 | M&L for Testing, servicing, inspecting of solar water heater of 100 TO 500 Litres per day capacity flat plate collector heat exchanger type installed in RMS / CDO WING /VASANT BLOCK/ cook houses make it functional including replacement of defective nuts, bolts, clamps, other minor parts and spare parts complete at any height or position including one coat of painting for complete setcomplete all as specified and as directed..Note: (i) Spare parts will be measured and paid separately under relevent items in this BOQ. (II) Servicing will be carried out by authorised company technician of concerned make only |
| 97 | Supply only solar heat exchanger make up water tank suitable for 100 TO 500 LPD solar water heater.complete all as specified and as directed.. |
| 98 | Supply only Toughned glass panel 5 mm thick of size 2m x 1mcomplete all as specified and as directed. |
| 99 | Supply Only PVC hose pipe of 20 mm dia not less than 2 m length from panel to water tank and vice versa at any height or position complete all as specified and as directed. |
| 100 | Supply onlysolar water geyser heat exchange tubes of measurement 2100mmx58mm, complete all as specified and as directed. |