| 1 | ClearingandGrubbingRoadLand.(Clearingand grubbingroadlandincludinguprootingrankvegetation, grass,bushes,shrubs,saplingsand treesgirth upto 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable materialtobeusedorauctioneduptoaleadof1000 meters including removal and disposal of top organic soil not exceeding 150 mm in thickness.)(ii) By Mechanical Means by Dozer(A) In area of light jungle |
| 2 | Excavation in Soil byManual Means. (Excavation for roadway in soil using manual means including loading in truck for carrying of cut earth to embankment site with all lifts and lead upto1000 meters as per relevant clauses of section 300). |
| 3 | Construction of Embankment with Material Deposited from Roadway Cutting (Construction of embankmentwithapprovedmaterialshavingeffective CBR >5(unlessspecifiedotherwiseincontract) depositedatsitefromroadwaycuttingandexcavation from drain and foundation of other structures graded and compactedtomeetrequirementoftable300-2)asper clause 305. |
| 4 | EmbankmentConstructionwithMaterialObtained fromBorrowPits(Constructionofembankmentwith approved material / selected soil having effective CBR > 5 ( unless specified otherwise in contract ) obtained from borrowpitswithallliftsandleads,transportingtosite, spreading,gradingtorequiredslopeandcompactingto meet requirement of table 300-2) as per clause 305. |
| 5 | ConstructionofSub-gradewithMaterialObtained from Borrow Pits (Construction of sub-grade with approved material / selected soil having effective CBR > 8 ( unless specified otherwise in contract ) obtained from borrowpitswithalllifts&leads,transportingtosite, spreading,gradingtorequiredslopeandcompactedto meet requirement of table No. 300-2) as per clause 305. |
| 6 | ConstructionofSub-gradewithMaterialObtained from Borrow Pits (Construction of sub-grade with approved material / selected soil having effective CBR > 8 ( unless specified otherwise in contract ) obtained from borrowpitswithalllifts&leads,transportingtosite, spreading,gradingtorequiredslopeandcompactedto meet requirement of table No. 300-2) as per clause 305. |
| 7 | Granular Sub-base with Close Graded Material (Table:- 400-1)(A) PlantMixMethodwithMechanicallycrushedstone only (Construction of granular sub-base by providing close gradedMaterial,mixinginamechanicalmixplantat OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per clause 401 )(iii) for grading-III Material |
| 8 | WetMixMacadam/Interlockinglayerlayingusing by Grader (Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material withwateratOMCin mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver in sub- base / basecourseonwellpreparedsurfaceandcompacting with vibratory roller to achieve the desired density.) as per |
| 9 | DenseGradedBituminousMacadam(Providingand laying dense graded bituminous macadam with 120 -200 TPHhighercapacityBatchTypeHMPusingcrushed aggregates of specified grading, premixed with bituminousbinderVG-40byweightoftotalmixand filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control tothe requiredgrade,level andalignment,rolling with smooth wheeled,vibratoryandtandemrollerstoachievethe desiredcompactionasperMoRTHspecificationclause No. 505 & 112 complete in all respects)(A) With sensor paver finisher(ii) for Grading II (26.5mm nominal size bitumen content minimum 4.50%) |
| 10 | Bituminous Concrete (Providing and laying bituminous concretewith120-200TPHhighercapacityBatchType HotMixPlantusingcrushedaggregatesofspecified grading,premixedwithbituminousbinderVG-40and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control tothe requiredgrade,level andalignment,rolling with smooth wheeled,vibratoryandtandemrollerstoachievethe desiredcompactionasperMORTHspecificationclause No. 507 & 112 complete in all respects)(A) With sensor paver finisher(iii) forGrading-II(13.2mmnominalsize)withbitumen minimum 5.4 % |
| 11 | Prime Coat over WMM/WBM (Providing and applying primer coat with bitumen emulsion or cutback bitumen on preparedsurfaceofgranularBaseincludingclearingof roadsurfaceandsprayingprimerattherateof0.85 kg/sqm using mechanical means as per clause 502 & 112) (i) with bitumen emulsion (SS-1, grade confirming to IS:8887) @0.85 kg/sqm |
| 12 | Tack coat (Providing and applying tack coat with bitumenemulsionRS-1,gradeconfirmingtoIS:8887 using emulsion pressure distributor on the prepared bituminoussurfacecleanedwithmechanicalbroom)as per clause 503 & 112.(i) on Bituminous surfaces @ 0.25 kg per sqm |
| 13 | on Granular surfaces treated with primer @ 0.30 kg per sqm |
| 14 | Granular Shoulders (Construction of granular shoulder at top 150mm of earthen shoulder shall be well graded mix of at least 30% of granular sub-base material of grading-III as per clause 401 and moorum/gravel or soil and combination having soaked CBR value of not less than 30%. The granular layer shall be compacted to at least 98% of mix dry density of material as determined as per IS:2720 (Part-B)) |
| 15 | Road Marking with Hot Applied Thermoplastic CompoundwithReflectorisingGlassBeadson Bituminous Surface (Providing and laying of hot applied thermoplasticcompound2.5mmthickincluding reflectorisingglassbeads@250gmspersqmarea, thickness of 2.5 mm is exclusive of surface applied glass beadsasperIRC:35.Thefinishedsurfacetobelevel, uniform and free from streaks and holes.) |
| 16 | KiloMeterStone(Reinforcedcementconcrete M15gradekilometerstoneof standarddesign asper IRC:8-1980,fixinginpositionincludingpaintingand printing etc)(i) 5th kilometre stone (precast) |
| 17 | (ii) Ordinary kilometer stone |
| 18 | (iii) Hectometer stone |
| 19 | Boundary pillar (Reinforced cement concrete M15 grade boundary pillars of standard design as per IRC:25-1967, fixed in position including finishing and lettering but excluding painting) |
| 20 | Providing & Fixing Delineator made of M.S. Hollow Rectangular Pipe (Conforming to IS: 4923) of cross section 100 mm x 80 mm, thickness 4mm, of 1.10 meter length. The top of the hollow pipe, welded and closed with 16 gauge M.S. Sheet. The height of the Delineator above ground level should be between 0.8 meter and 0.9 meter and 0.20 to 0.30 m below ground. The bottom of the delineator should be provided with holdfast of length 15cm on each side. Delineator should be painted with coat of Zinc Chromate stoving Prime and two coats of Black Stove Enamel (Oven Baked) paint with 3nos. 15 cm bands of white Retro-reflective Sheeting of Engineering Grade pasted around the pipe and 2 Nos. High intensity Grade Retro-reflective Sheeting of size 8 cm x 10cm pasted on the top of each side of Delineator and treated With HLVA & fixing the same in M-15 grade concrete block of size 45x43x30cms including transportation etc. complete. The construction and placement of the delineator must be as per IRC: 79. |
| 21 | Retro- reflectorised Traffic signs (Providing and fixing ofretro-reflectorisedcautionary,mandatoryand informatory sign as per IRC :67 made of retro- reflective type sheeting and vide clause 801.3, 2mm thick aluminium sheeting, 3mm/4mm thick Aluminum composite material sheet depending on the size of the sign fixedoverbacksupportframeofmin40x40x5mm Angle mounted on a mild steel circular pipe 65 NB ,3.2 mmthicknnessfirmlyfixedtothegroundbymeansof properlydesignedfoundationwithM15gradecement concrete 45 cm x 45cm x60 cm,60 cm below ground levelasperapproveddrawingandpaintingall components of the signs and supports as per clause 7.2 of IRC:67 )MadeofClass-CMicroPrismatic GradeSheeting of Type-XI (for National Highways and State Highways)(ii) 90 cm equilateral triangle |
| 22 | (xiv) 120 cm high octagon |
| 23 | (vi) 90 cm circular |
| 24 | (xii) 60 cm x 45 cm rectangular |
| 25 | Direction and Place Identification signs with size more than 0.9 sqm size board. (Providing and erecting direction and place identification retro- reflectorised sign as per IRC :67 made of retro- reflective type sheeting and videclause 801.3,fixedoveraluminumsheeting,2mm thick with area exceeding0.9 sqm fixed over back support frame of min 35 x 35 x 3mm Angle mounted on a mild steel circular pipe 65 NB firmly fixed to the ground bymeansofproperlydesignedfoundationwithM15 gradecementconcrete45cmx45cmx60cm,60cm below ground level as per approved drawing)(A) MadeofClass-CMicroPrismatic GradeSheeting of Type-XI (for National Highways and State Highways) |
| 26 | Providing and fixing Raised Pavement Markers made of polycarbonate ABS moulded body and reflective panelswithmicroprismaticlenscapableofproviding total internal reflection of the light entering the lens face and shall support a load of 16000 Kg tested in accordance to ASTM D 4280 type H and complying to specifications ofcategory AofMORT&H (RW/NH-33023/10/97-DO IIIDtd. 11.06.1997). The pavement markers will be auto moulded by dual polymer shanksand mustcomply with alltheMoRT&Hspecifications.Theheight,widthand lengthshallnotexceed50mm,100mmand100mm respectivelyandwithminimumreflectiveareaof13 Sq.cm. on each side and slope to the base shall be 35 +/-5 degree.Thestrengthofdetachmentoftheintegrated cylindrical shanks (of diameter not less than 19 +/- 2 mm and height not less than 30 +/- 2 mm) from the body is to be a minimum value of 500 kgf. Fixing will be by drilling holesonroadfortheshankstogoinside,withoutnails andusingepoxyresinbasedadhesiveandcompleteas directed by the Engineer-in-charge. |
| 27 | Metal Beam Crash Barrier(A) Type-A, \"W\" : Metal Beam Crash Barrier (Providing and erecting a \"W\" metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 70 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre, 1.8 m high, 1.1 m below ground/road level firmly fixed to the ground by means of foundation with M-15 grade cement concrete 30 x 30 x 110 cm, all steel parts and fitments to be galvanised by hot dip process, all fittings to conform to IS:1367 and IS:1364, metal beam rail to be fixed on the vertical post with a spacer of channel section 150 x 75 x 5 mm, 330 mm long complete as per clause 811.3) |
| 28 | Repair and Rehabilitation of structures including diversion as per specification and as per instruction given by Engineer in charge complete. |
| 29 | Street Lighting (Providing and erecting street light mounted on a steel circular hollow pole of standard specifications for street lighting, 9 m high spaced 40 m apart, 1.8 m overhang on both sides if fixed in the median and on one side if fixed on the footpath, fitted with Sodium vapour lamp/LED lamp and fixed firmly in concrete foundation M-15, providing 2 coats of alluminium paint over steel pole etc. complete.)(ii) For fixing in Footpath (single arm and single lamp on single pole) |
| 30 | Length of Triangular Earthen Drain (0.600 m Width)(i) Excavation for Drain Work |
| 31 | Length of Trapezoidal Earthen Drain (1.00 m Width)(ii) Excavation for Drain Work |
| 32 | Double row for two utility service across the road |
| 33 | Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.)(I) Ordinary soil(B) Mechanical Means (i) Depth upto 3 m |
| 34 | Plain/Reinforced cement concrete in open foundation complete as per drawing and technical specifications(A) PCC Grade M15(Case - I) With Batching Plant, Transit Mixer and Concrete Pump |
| 35 | Plain/Reinforced cement concrete in sub- structure complete as per drawing and technical specifications(F) RCC Grade M25(i) Height upto 5mWith Batching Plant, Transit Mixer and Concrete Pump |
| 36 | Supplying, fitting and placing HYSD bar reinforcement in sub-structure complete as per drawing and technical specifications |
| 37 | Providing and laying of Filter media with granular materials/stone crushed aggregates satisfying the requirements laid down in clause 2504.2.2. of MoRTH specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment, wing wall and return wall to the full height compacted to a firm condition complete as per drawing and Technical Specification. |
| 38 | Providing weep holes in Brick masonry/ Plain/Reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing foce. Complete as per drawing and Technical specifications |
| 39 | Dismantling DismantlingDismantling of Structures (Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, includingT&P and scaffolding wherever necessary, sorting1) Wearing Course |
| 40 | 2) HPC |
| 41 | 3) Cushion |
| 42 | 4) Head Wall |
| 43 | Site Clearance Clearing Grass and Removal of Rubbish (Clearing grass and removal of rubbish up to adistance of 50 metres outside the periphery of thearea) |
| 44 | Excavation Work Excavation for Structures (Earth work inexcavation of foundation of structures as perdrawing and technical specification, including setting out, construction of shoring and bracing,removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling withapproved material.) |
| 45 | Filter MediaFilter MediaProviding and laying of Filter media withgranular materials/stone crushed aggregatessatisfying the requirements laid down in clause 2504.2.2. of MoRTH specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment, wing wall and return wall to the full height compacted to a firm condition complete as per drawing and Technical Specification.Side Walls |
| 46 | Plain/Reinforced Cement Concrete in OpenFoundation complete as per Drawing and TechnicalSpecifications M15 gradePCC- M15 levelling course |
| 47 | PCC M15 Grade leveling course below approach slab complete as per drawing and Technical specification approach slab |
| 48 | Reinforced cement concrete approach slab withRCC grade M-30 including reinforcement andformwork complete as per standard drawing ofMoRTH and Technical specification. |
| 49 | Plain/Reinforced Cement Concrete for wall & slab etc. complete as per Drawing and Technical Specifications. M-35 |
| 50 | HYSD bar reinforcement Supplying, fitting and placing HYSD bar reinforcement in sub-structure complete as per drawing and technical specifications Box Portion |
| 51 | Expansion joints Strip Seal Expansion Joint (Providing and laying of a strip seal expansion joint catering to maximum horizontal movement upto 70 mm, complete as per approved drawings and standard specifications tobe installed by the manufacturer/supplier or theirauthorised representative ensuring compliance tothe manufacturer\"s instructions for installation.) |
| 52 | Providing and laying Cement concrete wearingcoat M-30 grade including reinforcement completeas per drawing and Technical Specifications Wearing Course (75 mm thick) Wearing Course (75 mm thick) |
| 53 | Providing weep holes in Brick masonry/Plain/Reinforced concrete abutment, wing wall/ return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V:20H towards drawing foce. Complete as per drawing and Technical Specifications Weep holesWeep holesi) Side walls of BOXii) Retaining walls |
| 54 | Drainage Spouts complete as per drawing and Technical specification Drainage Spouts |
| 55 | Providing and laying Pitching Stone/Boulder onslopes laid over prepared filter media includingboulder apron laid dry in front of toe ofembankment complete as per drawing andTechnical specifications as per clause 2504. |
| 56 | Providing and laying Filter material underneathpitching in slopes complete as per drawing and Technical specification including trimming of slopesto proper profile and preparation of bed and as per clause 2504. |
| 57 | Providing and laying Flooring complete as perdrawing and Technical specifications laid overcement concrete bedding.i) For Down Stream Side (5m Long)ii) For Up Stream Side (3m Long) |
| 58 | Flexible Apron :Construction of flexible apron 1 m thick comprising of loose stone boulders weighing not less than 40 kg beyond curtain walli) For Down Stream Side (6m Long)ii) For Up Stream Side (3m Long) |
| 59 | Crash Barriers (Reinforced Cement ConcreteCrash Barrier (Provision of an Reinforced cementconcrete crash barrier at the edges of the road,approaches to bridge structures and medians,constructed with M-25 grade concrete with HYSDreinforcement conforming to IRC:21 and dowel bars 25 mm dia, 450 mm long at expansion joints filled with pre-moulded asphalt filler board, keyed to the concrete crash barrier structure on which it is built and installed as per design given in the enclosure to MOST circular No. RW/NH - 33022/1/94-DO III dated 24 June 1994 as per dimensions in the approved drawing and atlocations directed by the Engineer, all as specified) |
| 60 | Curtain wall complete as per drawing and Technical specification- PCC Grade M15 |
| 61 | Construction of Sub-grade with Material Obtained from Borrow Pits (Construction of sub-grade with approved material / selected soil having effective CBR > 8 ( unless specified otherwise in contract ) obtained from borrow pits with all lifts & leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of tableNo. 300-2) as per clause 305. |
| 62 | Granular Sub-base with Close Graded Material(Table:- 400-1Plant Mix Method withMechanically crushed stone only(Construction of granular sub-base by providing close graded Material, mixing in amechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per clause 401 ) for grading- II Material |
| 63 | RCC pipe NP-4 1000 Dia. |
| 64 | Plain/Reinforced Cement Concrete for wall & slab etc. complete as per Drawing and Technical Specifications.RCC M35 For Retaining wall-With Batching Plant, Transit Mixer and Concrete Pump |
| 65 | Supplying, fitting and placing HYSD bar reinforcement in sub-structure complete as per drawing and technical specifications |