| 1 | Special repair of ETP Plant inside OCFS Factory. |
| 2 | Excavating in trenches n.exe.1.5m wide and n.exe.1.5m in depth for foundation and getting out soft/loose soil |
| 3 | M&L broken brick hardcoreof gauge n.exc.63 mm, deposited, spreaded and levelled in layers n.exc. 15cmthick watered and rammedto a true surface. |
| 4 | M&L cement conerete in foundation, filling and mass concrete TypeC2 1:3:6(40mm stone aggregate). |
| 5 | M&L brick work with sub class \"A\"bricksstraight or curved on planexc. 6mmean radius built in1:4 mix cement mortar. |
| 6 | M&L for providing cementconcreteType B1, 1:2:4( 20mm stone aggregate)in coping of wall etc. |
| 7 | Providing 100 mm Cement concretetype B-0, 1:2:4 (12.5mm graded aggregate) finishing cement concrete surface even and smooth without using extra cement concrete. |
| 8 | Rendering 12mm thick cement plaster in 1:4 mix cement mortar on walls. |
| 9 | M&L of Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steelpins, etc. as directed. |
| 10 | Demolation of reinforced cement concrete any descreption. |
| 11 | Form work to curved side of retaining walls,vertical or to batter with fair finished surface of concrete. |
| 12 | Formwork to curved sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter rough finished surfaces of concrete. |
| 13 | M&L of Reinforced cement concrete type B-1 1:2:4 (20mm graded aggregate) Walls, retaining walls, basement walls, ballast walls and the like; any thickness; above top of footings; including attached pilaster and buttresses. |
| 14 | Providing RCC type B-1 1:2:4 (20 mm graded aggregate) in foundation including rafts footing foundation beams plinth beam bases for column etc. |
| 15 | M&L M.S. Bars 10 mm dia or over, cut to lenth, bent to shape and binding with M.S. wire as required/directed . (TMT bars). |
| 16 | M&LMild steel bars 6mm dia to 8mm dia, cut to length,bent to shap required, including cranking,bending and binding with mild steel wire (annealed) not less then 0.9mm dia.(TMT bars). |
| 17 | Preparation of new surface of wall and apply two coat of cement paint as specified. M&L complete. |
| 18 | Preparation of old surface of wall and apply two coat of cement paint as specified. M&L complete. |