| 1 | Demolition of cement concrete un reinforced in ground floors and paving of any position and any thickness thickness below or above GL complete all as specified and directed. |
| 2 | Demolition of reinforced cement concrete any description and in any position and any thickness complete all as specified and directed. |
| 3 | Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed. |
| 4 | M&L for brick work with kiln burnt bricks (old size) built in CM (1:6) using sub class \"B\" bricks straight or curved on plan exceeding 6 meter mean radius complete all as specified and directed. |
| 5 | M&L for Brickwork with old size subclass \"B\" bricks, straight or curved on plan in half brick thick wall built in CM 1:4 complete all as specified and directed. |
| 6 | Taking down cement plaster on brick work or stone walls, etc incl raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed. |
| 7 | M&L for rendering 15 mm thick on fair faces ofbrick work or concrete surfaces in CM 1:6 and finished even and smooth with out using extra cement, etccomplete all as specified and directed. |
| 8 | M&L two coat cement plaster ,first coat 10 mm thick CM 1:6 and second coat cement plaster 5mm thick in CM 1:4 with WPC @ 200 ml per 50 kg bag of cement ,finished even and smooth without using extra cment. ( WPC will be paid seperately under respective item),etc complete all as specified and directed. |
| 9 | M&L Rendering 5 mm thick on fair faces ofconcrete surfaces in CM (1:4) in finished even and smooth without using extra cement in ceiling complete all as specified and directed. |
| 10 | Supply only liquid water proofing compound complete all as specified and directed. |
| 11 | M&L for Applying three coats of white wash on newly plastered onwall surface including preparation of new surface complete all as specified and directed. |
| 12 | M&L for Two coat of white wash on old decorated surface of walls including preparation of old surface i.ebrooming down with steel wire brushes scraping downmoulds moss and efflorescent salts and treating oil and greasy spots, removing of nails, making good holes , craks etc and washing floors, cleaning glass , joinery , electric fitting, etccomplete all as specified and directed. |
| 13 | M & L forapplyingtwo coatsexterior emulsion ( Ace paint or equivalent) over one coat of exterior primerincludingpreparation of surfaces of new walls etc complete all as specified and directed. |
| 14 | M & L for complete removal of existing treatment and applyingtwo coatsexterior emulsion ( Ace paint or equivalent) over one coat of exterior primeron old surfaces of walls etc complete all as specified and directed. |
| 15 | M&L for for complete removal of existing treatment and applying two coats ofWhite wash onold ceiling surfaces and ceilingsurfaces complete all as specified and directed. |
| 16 | M&L three coats of White wash on newly plaster surface of ceiling including preparation of newly surface complete all as specified and directed. |
| 17 | S&F for Mild steel TMT bars 10mm dia, and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends & binding with & including mild steel wire (annealed) not less than 0.9mmdia or securing with clips qualitycomplete all as specified and directed. |
| 18 | S&F for Mild steel TMT bars 6mm to 8 mm dia cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends & binding with & including mild steel wire (annealed) not less than 0.9mmdia or securing with clips quality complete all as specified and directed. |
| 19 | M&L RCC 1:1.5:3 (nominal mix) type B-0 using 12.5 mm graded stone aggregate as in landing, cooking platforms, shelves and the like complete all as specified and directed. |
| 20 | Use and waste of formwork to soffits of suspended slabs, landings, shelves and similar work n exc 200mm thick horizondal or sloping complete all as specified and directed. |
| 21 | M&L cement concrete 1 : 3 :6 type C-2 using 40mm graded stone aggregate as in plinth protection 75mm thick finishing cement concrete surfaces even & smooth without using extra cement including filling of joints with bituminous compound complete all as specified and directed. |
| 22 | Taking down chowkhat or frame (without taking off shutter from the frame)not exceeding 1.5 Square Metre each , removing from the site including Cutting holes exc 150 Sq.cm but n.exc 400 Sq.cm in super facia area into or through brick walls built in cement mortar and making good in cement mortar 1:3 or cement concrete 1:2:4 type B-l as required complete all as specified and as directed. |
| 23 | Taking down chowkhat or frame (without taking off shutter from the frame) exceeding 1.5 sqm and not exc 4.00 sqm each , removing from the site Including Cutting holes exc 150 Sq.cm but n.exc 400 Sq.cm in super facia area into or through brick walls built in cementmortar and making good in cement mortar 1:3 or cement concrete 1:2:4 type B-l as required complete all as specified and as directed. |
| 24 | S&F Solid PVC door frame of size 50mmX47mm made out of 5mm thick moulded single side prelam PVC sheet used instead of plain colour PVC sheet (edges will be painted to match with prelam sheet) reinforced with MS square tube, suppling & fixing in opening as per specification complete all as specified and directed. |
| 25 | S&F factory made solid PVC mouldeddoor shutter with wood free EPS , 28 to 30mm thick (stiles),with 5 mm thick moulded prelam PVC sheet on the front face & 5 mm thick prelam PVC sheet on back face, centre core 18- 20 mm thick will be PVC battern supplying & fixing in frame at site complete all as specified and directed. |
| 26 | S&F 100 mm butt hinges extruded aluminium alloy with galvanised mild steel hinges pin, anodised and fixed complete all as specified and directed. |
| 27 | S&F 150 mm long aluminium handles fabricated type anodised etc all as specified complete all as specified and directed. |
| 28 | S&F 150 mm Aluminium anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed. |
| 29 | S&F in repair stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed. |
| 30 | M&L for preparation of old steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enameled paint over a coat of red oxide all as specified and directed. |
| 31 | S&F 3 mm thick sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane including hacking out old broken glass (any thickness, size,quality or description) from wooden / steel frames glazed with oil putty or fixed with beadscomplete all as specified and directed. |
| 32 | S&F for 3 mm thickFigured glass, pin head type and glazing with oil putty in squares n exc 0.5 sq. m in each pane including hacking out old broken glass (any thickness, size,quality or description) from wooden / steel frames glazed with oil putty or fixed with beadscomplete all as specified and directed. |
| 33 | S&F Mild steel door shutter with MS angle iron shutters frame 35 mm X 35 mm X 5 mm in two panel covered with 1.25 mm thick MS plain black sheet welded to shutter with 2 Nos sliding door bolt of 16 mm dia300 mm long with locking arrangement, 2 Nos of tower bolt of200 mm long including MS angle iron frame 40 mm x40 mmx 5 mm as in chowkhat with 6 Nos hold fast of flat iron 30 mm X5 mm ,200 mm long with bottom flat iron of size 30mmx5mm, diagonally bracing of 30 mmX5 mm and 100 mm size4 Nosbutt hinges including necessary cutting, welding, binding as required with two coats of synthetic enamel paint over a coat of red oxide primer including preparation of new steel surfaces complete all as specifiedand as directed.[Single shutters of approx width 0.7 to 1.2 m andht 1.9 to 2.10 M.] |
| 34 | Dismantling of floor, hearth or wall tiles / terrazo/ kota stone /granite including cement mortar bedding and rubbish off the premises, complete all as specified and directed. |
| 35 | M&L 25mm thick PCC 1:2:4 type B-0using 12.5 mm graded stone aggregate as in sub base of floor complete all as specified and directed. |
| 36 | M&L for plain cement concrete 1:4:8 type D2 using 40mm graded stone aggregate as in foundation filling and mass concrete etc complete all as specified and directed |
| 37 | M&L Non skid ceramic coloured tiles 7 to 8mm mm thick (Square/ rectrangular) area of each tiles exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc over and including 15 mm thick cement screed bed in CM 1:6. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed. |
| 38 | Material & labour for glazed ceramic tiles of size600x 300 x 7mm thick,(joint free (rectified))coloured, on vertical surfaces such as skirting/dado etc, set and jointed in neat cement slurry and pointed in white/ coloured cement to match overand including 15 mm thick rendering in CM 1:4 complete all as specified and directed. |
| 39 | M & L for granite stone 16-18 mm thick machine cut, bedding & jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including cutting and polishing type over and including 10mm thick screed bed in CM 1:4 as in kitchen platform and rounding of edges of stone slab all as specified and directed |
| 40 | S&F GI tubing 15 mm bore medium grade with all fittings fixed to walls and ceilings or laid in floors including taking down 15 mm diaGI tubing and connections complete all as specified and directed |
| 41 | S&F 20 mm outer dia of CPVC pipes SDR 11& Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors incl fittings and the holes in walls and floors shall be made by drilling with drill or jumper and not by dismantling the brick/ concrete. After fixing holes shall be made good with CM 1:3 properly complete including taking down 15 mm diaGI tubing and connections complete all as specified and directed. |
| 42 | Cutting chases for concealed water tubing or concealed conduit wiring etc. and making good, cutting n exc 10cm girth. pinning in, making good to facings where required and pointing in CM 1:3 on stone walls complete all as specified and directed. |
| 43 | S&Fin repair 15mm bore CP fancy type brass bib taps chromium plated cast copper alloy with crutch or butterfly handlescrewed down,screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed. |
| 44 | S&F in repair 15mm bore angle cock CP fancy type chromium plated with butter fly handle, screwed down,high pressure for iron pipes or for unions fixed in repairs complete all as specified and directed. |
| 45 | S&F in repairs 2 way bib cock with single knob15mm dia chromium plated, cast copper alloy complete all as specified and directed. |
| 46 | S&F in repairs health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in positioncomplete all as specified and directed. |
| 47 | Supply and fixed in repair stopvalve , 15mm dia, cast copper alloy,CP fancy type with long shank and cup Concealed type ,screwd down, high pressure ,screwed both ends for iron pipes or for unions and fixed in pipe complete all as specified and directed. |
| 48 | S&F in repair 125 mm size brass chormium plated shower rose with long body including fixing to steel pipe or union complete all as specified complete all as specified and directed. |
| 49 | S&F in repairvitreous china squatting pan \"Orrisa pattern\" size 580x440mmwhitewith integral foot rests any pattern including provn of cement concrete bedding and making connection with & including \"P\" or \"S\" Trap, etccomplete all as specified and directed complete all as specified and directed. |
| 50 | S&F in repair Vitreous China wash down water closet pan (pedestal pattern) s trap and all fittings , white including white seat cover complete all as specified and directed. |
| 51 | S&F in repair vitreous china WHB snow white countersunk oval shape of size 520x450x200 mmincluding S&F C.P pillar tap swan neck fancy type (quarter turn)01 No 15mm bore, CP waste coupling, 32mm dia and PVC waste pipe 32mm dia and PVC connection 450mm long high pressure complete all as specified and directed. |
| 52 | S&F in repairs Vitreous China bowl urinal half stall type white (min.), with grating & union for discharge pipe including flush pipe and waste pipe complete all as specified and directed. |
| 53 | S&F in repair PVC low level flushing cisternof 10 Ltr capacity, dual (5 Ltr/10 Ltr) valve less including flushing pipe bend PVC bend, PVC connection etc. complete all as specified and directed. |
| 54 | S&Fin repairs purposely moulded looking mirror 5 mm thick glass fixed with studs complete all as specified and directed. |
| 55 | S&F in repair CP tubular towel rail 600mm long between flanges, 20mm dia, D typeetc complete all as specified and directed. |
| 56 | S&F in repair CP Soap dish, chromium plated fixed to wall with brass chromium plated screw and wooden/ plastic plug etc complete all as specified and directed. |
| 57 | S&F in repair PVC (SWR) Pipe single socketed in any length with adhesivejointlaid infloor or fixed to wallwith clamps for 110mm diacomplete all as specified and directed. |
| 58 | S&F in repair PVC (SWR) Pipe single socketed in any length with adhesive joints laid infloor for or fixed to wall with clamps 75mm diacomplete all as specified and directed. |
| 59 | S&F in repair PVC Bends any radius 110mm dia provided with access doorcomplete all as specified and directed. |
| 60 | S&F in repair PVC Bends any redius 75mm dia provided with axcess door complete all as specified and directed. |
| 61 | S&F in repair PVC (SWR) Junction single T equal or unequal 110mm dia provided with access door complete all as specified and directed. |
| 62 | S&F in repair PVC (SWR) Junction double T equal or unequal 110mm dia provided with access door complete all as specified and directed. |
| 63 | S&F in repair PVC (SWR) Junction single T equal or unequal 75mm dia provided with access door complete all as specified and directed. |
| 64 | S&F in repair PVC (SWR) Junction double T equal or unequal 75mm dia provided with access door complete all as specified and directed. |
| 65 | S&F in repairPVC vent cowl 110mm diacomplete all as specified and directed. |
| 66 | S&F in repairfor75mm outlet dia PVC (SWR) floor trap, plain with grating including jointing with solvent cementcomplete all as specified and directed. |
| 67 | M&L for precast reinforced cement concrete 1:1.5:3 type B-0 using 12.5 mm graded stone aggregate as in cover slab of manhole set in cement mortar 1:4 including demolition of existing broken cover slabs complete all as specified and directed. |
| 68 | Treatment for sunken portion is as follows :-(i) Demolition of lean concrete and other type of filling in sunken portion & cleaned the sunken portion incl vertical wall surface complete as directed. (ii) M&L for providing 12 mm dia holes of 40mm deep @200mm c/c at junction of beams and columns as co-ordinal points for inserting/pouring cement slurry with dr fixit grouting compound by pressure grouting for sunken floors of toilet , includind sealing the holes with CM 1:3, all as specified and as directed by Engr-in-Charge. (iii) M&L for water proofing plaster for sunken portionin CM 1:3, 20 mm thick in two coats with water proofing compound @ 200 ml per 50 kg bag of cement and finishing the surface even and smooth without using extra cement.(iv) M&L for applying two coats of Dr fixit compound suitable for sunkun treatment as per manufacturer instructions over vertical surfaces and floors of sunken of toilet including cleaning of surfaces.(v) M&L for PCC 1:4:8 type D2 using 40 mm graded stone aggregate as in filling (sunken portion). etc.(vi) M&L for PCC 1:2:4 type B-0 using 12.50 mm graded stone aggregate, mixed with WPC @ 200 ml per 50 kg bag of cement , as sub base, 75mm thick on top.Note :- above includes (a) Test again of water tightness by pounding for 72 hours & rectify defects if any till total elimination of defect.(b) The sunken portion shall be tested for leakage / seepage / dampness by pounding with water for 72 hours. In case any defect is noticed the portion shall be grouted with Dr fixit suitable chemical & tested again. The process of grouting and testing shall be repeated till leakage / seepage / dampness is eliminated (c) Horizontalflat area to be measered complete all as specified and directed. |
| 69 | Taking down copper/aluminium point wiring (light fan, socket or power) complete including fittings such as switch,sockets, c/rose, lamp holders, tube light fittings, sketch fitting , wooden boards, bell push, call bell, MCBs & regulators etc & making good to disturbed surfaces & matching with the existing colour of wall floor etc. |
| 70 | M&L for concealed point wiring with 1.5 Sqmm FRLS PVC insulated, unsheathed, copper conductor stranded 1100 volt grade cable in & incl PVC rigid conduit medium grade of size not less than 20 mm dia ISI marked ivory white with all accessories such as tee, bend, joint cover etc/square TW Mica Top blocks at junction for batten holders, ceiling rose etc screws, gutti/roul plugs PVC all as per site requirement including MS sunken boxes made out of ms sheet and PVC laminated hylem/Anchor ISI marked top cover 3.0 mm thick for mounting of switches/sockets regulator etc and PVC insulated & unsheathed 1100 volt grade copper conductor, stranded 1.5 sqmm cable as continuous earth lead complete all as specified and colour coding of cables such as Phase-Red, Neutral-Black and Earth-Green complete all as specified and directed.Note: cutting of walls (brick or stone), making good disturbed surface of wall in CM 1:3 and painting with existing colour & specifications is deemed to include in the quoted rate. |
| 71 | For one light, fanpoint controlled by one switch |
| 72 | All as per item No 70.00 here in before but for power point wiring usingwith 2.5 sqmm FRLS PVC insulated , unsheathed, copper conductor stranded 1100 volt grade cable and 2.5 sqmm PVC insulated ,unsheathed, copper conductor stranded 1100 volt grade cable as continuous earth lead complete all as specified and colour coding of cables such as Phase-Red, Neutral-Black and Earth-Greencomplete all as specified and directed. |
| 73 | S&F switch piano type flush, single pole, one way,15 Amp 230 Volt complete all as specified and directed. |
| 74 | S&F socket outlet 2 in 1, 6 pin, 5/15 Amp ,flush type universal shuttered 230 Volt complete all as specified and directed. |
| 75 | S&F ceiling rose, surface backlite, 63.5x48 mm three terminal complete all as specified and directed. |
| 76 | S&F lamp holder modular type insulated with back plate suitable for Angle/Batten fitting with9 Watt LED bulb complete all as specified and directed. |
| 77 | S&F testing and commissioning of MCB SP 6-40 Amp 240 Volt 10 KA capacity having C-curve characteristics connected with suitable lugs complete all as specified and directed. |
| 78 | All as per item No. 76.00 but SPN 32- 63 Amps, 240 V complete all as specified and directed. |
| 79 | S&F sheet metal enclosure for DB double door, IP-43 when MCBs to be used SPN, 4 way, 240 V with 200 Amps rated bus bar incl TW board of suitable size complete all as specified and directed.Note: cutting of walls (brick or stone), making good disturbed surface of wall in CM 1:3 and painting with existing colour & specifications is deemed to include in the quoted rate. |
| 80 | Taking down and refixing/connecting exhaustfan with and including painting complete all as specified and directed. |
| 81 | S&F LED 20 wattfitting for surface mounted luminaires batten with extrued PVC housing and robust long life corresion resistance impact proof surface mounting IP66 Lumanires PChousing in opeal finish cover with high brightness complete all as specified and directed. |
| 82 | M&L for concealed sub main wiring with 2 single core PVC insulated, unsheathed copper conductor stranded 1100 volt grade cable of size 4 sqmm (FRLS) drawn in and incl PVC rigid conduit medium grade of size not less than 20 mm dia ISI marked ivory white with all accessories such as tee, bend, joint cover etc PVC insulated, unsheathed copper conductor stranded 1100 volt grade cable of size4 sqmm (FRLS) cable as continuous earth lead complete all as specified and colour coding of cables such as Phase-Red, Neutral-Black and Earth-Green. Note:-(i) Making good disturbed surface of wall in CM 1:3 and painting with existing colour & specifications is deemed to include in the quoted rate.(ii)Two runs of single core for main current and one run of single core for earth continuity conductor & one run of PVC Casing-n-caping shall be measured as one unit length. |
| 83 | Taking down existing geyser and refixing of electric water heater (Geyser) ISI marked 25 Ltrs capacityAC 230V, 5 star rating Branded heavy duty automatic cutoff and including electric connection lead of suitable size and length and all accessories, grouting of nut bolt/fastner on wall and making good disturbed surface complete all as specified and directed. |
| 84 | S&F exhaust fan 300mm sweep metalbody incl Lovers complete incl making holes in any constucioncomplete all as specified and directed. |
| 85 | M&L for provn of earthing complete with MS galvanized earth plate electrode 600x600x6 mm thick buried directly in ground ( earth pit not less than 2.25 M deep below normal GL) with top edge of plate not less than 1.5 M below normal ground level connected to galvanized earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of CI or steel incl excavation, PCC (1:3:6) type C-1 chamber with CI cover 10 mm thick, 15 mm dia light grade , GI protection pipe, funnel with wire mesh, watering pipe of size 20 mm dia, medium grade, lugs, main earthing lead upto main switch/DB incl charcoal dust, salt etc all as shown in electrical plate No. 3 of SSR part-I 2020 specification complete all as specified and directed.. |