| 1 | BSR ITEMS (Rates are Based on PWD Electrical), AS PER BSR 2022 |
| 2 | Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC, UTP (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable as per latest ammendments of ANSI/TIA/EIA-568 , The copper conductors should be balanced twisted in pairs, seperated by a cross-member fluted pair divider & protected byPVC Jacket. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies up to 250 Mhz. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack &ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . |
| 3 | S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along withISI marked (IS:3419-1988) accessories as requiredinrecessincludingcutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR |
| 4 | 25 mm |
| 5 | 32 mm |
| 6 | Providing & Fixing of ISO certified company made virgin material PVC trunking system as per PWD specification for electrical Works, with double lock feature for cable management including finishing accessories like corners, tees, adjustable angles, junction etc. as required . The trunking system shall have adaptable system for modular type RJ 45 data socket/ wiring accessories/ power sockets and shall be covered with peal off plastic cover. OEM shall have submit NABL accrediated /CPET lab test reports before execution & All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR . |
| 7 | 32mm X 20mm |
| 8 | Supply and Installation of unsheilded/360 degree sheilded Information outlets made of high impact plastic body with ABS, FR Grade halogen free material with provision for protection against dust in jack, suitable for Cat 6/6A application complying to latest ammendments, According. to Cat. 6/6A channel, It should support channel as well as components requirements of Cat.6/6A standards at frequencies of up to 250 to 500 Mhz. Cat 6/6A unshielded/shielded Jack should be suitable to terminate 4 pair, 23/24 AWG solid/stranded wire diameters, using 100 Ohm unshielded/shielded balance twisted pair cable, the jack should have tooless/impact termination on reliable copper tin plated Insulation displacement contact, with easy lock mechanism, It supports IEC 60603-7-4 and complied with ANSI/TIA/EIA 568 C.2 standard. jack should be RJ11,RJ12 & RJ45 compatible. Should support Ethernet 1.2 Gb/s ATM,Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP) Specifications in existing modular/MS Boxes along with necessory connections as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . |
| 9 | Cat 6, Un-sheilded Information Outlet |
| 10 | Supply & fixing of square Faceplate for Flush / Surface Mount Information Outlets Single/Dual or Quad Aperture ,material should bePC+ABS body, Suitable for RJ45 unshielded/shielded connection modules. Should match with I. O. OEM. Dimensions should be 86mm X 86mm as required complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . |
| 11 | Single Aperture |
| 12 | Providing & Fixing of Wiring Accessories OEM fabricated following size virgin materialUPVCmodular boxes on surface suitable for modular accessories as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . |
| 13 | 1-2-3 Module |
| 14 | Supply , Installation and Testing of 4 pair, 100 Ohm impedance, Cat 6/6A /Class E/Ea patch cords should be constructed of minimum 23/24 AWG, stranded bare Copper cable with FRPVC/LSZH Jacket, with an enhanced performance by factory moulded RJ45 connectors with strain relief boots as per ANSI/TIA/EIA 568-C.2 suitable for Cat 6/6A application complying to latest ammendments Category 6/6A Standards, According. to TIA568C.2, ISO/IEC 11801, EN 50173, IEC 60603-7-51, EN 60603-7, IEEE 802.3an minimum requirement for 1G BASE-T to 10G BASE-T performance. Patch cords shall be straight thru cable compatible with both T568-A and T568-B wiring schemes, should support IEEE 802.3af / IEEE 802.3at for POE applications, Minimum 750 to 1000 mating cycles in plug contacts for long durability, Should support Ethernet 10GBASE-T, 1.2 Gb/s ATM, Token ring 4/16, Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP).All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . |
| 15 | 1 Mtr |
| 16 | 2 Mtr |
| 17 | Supply, Installation, Testing and Comissioning of Rack mounted 19\" 1U, Cat6 24 Port loaded, 1.5-1.6 MM CRS chasis, powder coated, sheet steel, made of plastic (ABS), Modular Patch Panelswith Rear Cable management system and mounting hardware to mount the patch panel. Should have port identification numbers printed/engraved on front of the panel. Etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . |
| 18 | Modular Patch Panel Loaded with Cat -6 I/O |
| 19 | Supply & Installation of IP-20 & IK-08 , UL ListedWall mounted Double Section Communication enclosure (Rack) made from powder coated (60 to 80 Micron) CRCA sheet, front sturdy sheet steel frame folded from one piece and welded with minimum 5mm toughened glass door,Vertical Mounting Rail 1.6 MM with \"U\"Marking , with All round protective channel on the door aperture, lock integrated on front door, top and bottom cover with cable entry provision with gland plates, integrated side walls, 2 pair of 19\" angles with wall mounting provision on wall. Accessories like: 1 No of 19\" 1U Horizontal Cable manager, 1 No of 90 cfm 230V AC Fan with 1 mts long cable, mounting hardware , 1 No of 19\" 1U, mountable socket strips with 5 nos of 5A universal sockets with 2 mts long power chord for supplying power to switches, fans etc along with earth continuity kit, indicator, moulded power supply cable. fixing on wall with Suitable Anchor fastneretc as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . |
| 20 | 15 U Rack with Width 600 mm & Depth 400 mm + 100 mm |
| 21 | Supply, Drawing and Testing, of stranded Single mode (9/125 µm) glass optic fiber cable, as per latest ammendments of TIA/EIA 568/ISO/IEC, construction of LSZH outer sheath cable, cable should be used for LAN and WAN back bones, . With its LSZH sheathing these cables should be ideal for indoor/outdoorinstallations in existing MS/PVC /HDPE Conduits/ slotted channels with ferruling at both ends for identification complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . |
| 22 | 6 fiber |
| 23 | Supply, Installation, OTDR Testing & Fusion Splicing of Fiber Singlemode Pigtail (9/125 µm (OS1/OS2) made of glass fiber optic, with semi-tight buffer PA/PBT, Ø 0.9 mm, yellow, singlemode G652.D (9/125 µm (OS1, OS2), should have length of min 1.5m, should be fitted at one end with any one type of single ST/E-2000/SC/LC/MT-RJ/PC type connector in acc. withIEC 61754-20, Should be delta IL < 0.2 dB after 500 mating cycles, It should be Zirconia (ceramic) ferrule with a PC polished endface geometry connector qualified in acc. with IEC 61753-1 for category U (uncontrolled environment). and qualified in acc. with IEC 61753-1, Performance acc. to IEC 61753-1 (Table A.12) as per latest ammendments of TIA/EIA 569B.3, Standard Specification as per requirments.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . |
| 24 | Supply, Installation, & Testing of 19\" 1U Rack Mounted/ surface mounted aluminum/ CRCA 1.2mm powder coated, Singlemode glass Fiber Optic Cable Patch panel/LIU loaded with flangless/screwable duplex adapters for ST/E-2000/SC/LC/MT-RJ/PC type, It should have easy removable Top plate with push buttons, there should be a splice tray installed in the Patch panel/LIU which can handle the fiber cores, splice tray should be PC+ABS material, it should include accessories like mounting hardware, gormetts, heat shrink tubes/sleevs, screws, nuts to install the panel for rack/wallmount applications as per requirment complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . |
| 25 | 12 Ports |
| 26 | Supply, Installation, & Testing of Indoor duplex Singlemode patch cord (9/125 μm (OS1/OS2) made of glass fiber optic with LSZH jacket, F8 2.0x4.1 mm, yellow, singlemode G652.D (9/125 μm (OS1, OS2) Mounted on both sides with ST/E-2000/SC/LC/MT-RJ/PC type Duplex connectors in acc. with IEC 61754-20. Zirconia (ceramic) ferrule with a PC polished endface geometry, connectors should be tuned in accordance with IEC 61755-3-1 and qualified in acc. with IEC 61753-1 for category U (uncontrolled environment, duplex clip and white plastic dust cover, should comply to delta IL < 0.2 dB after 500 mating cycles, there should be an optional Visual coding, mechanical coding and lock protection on the patch cords which can be added on later stage. patch cords\"s performance should be acc. to IEC 61753-1 (Table A.12) as per latest ammendments of TIA/EIA 569B.3, as per requirements.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR . |
| 27 | Single Mode Patch Cord 3 Mtr. |
| 28 | Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR |
| 29 | 3x 1.5 sq.mm |
| 30 | 3 x 2.5 sq.mm |
| 31 | Providing & Fixing offollowing size mounting grid plates with cover plates made from fire retardent UV established high performance engineering plastic suitable for all universal metal boxes for front installation & removal direct fit type complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . |
| 32 | 6 Module |
| 33 | 8 Module |
| 34 | Providing & Fixing of Wiring Accessories OEM fabricated following size virgin materialUPVCmodular boxes on surface suitable for modular accessories as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . |
| 35 | 6-8 Module |
| 36 | Providing & Fixing of modular type switch/ bell push duly ISI marked (IS :3854) with CM/L no. printed and made out of unbreakable and fire retardant vergin UV Stabilized Polycarbonatewith brass terminals and captive screws & silver alloy contact tipwith IP-20 rating ,minimum width ofswitch toggle( PUSH PART ) should not less then 20mm,includingall as per pre approved by Engineer in charge,making connections, testing etc. as required. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR |
| 37 | 10 A one way switch |
| 38 | 16 A one way switch With LedIndicator |
| 39 | Providing & Fixing of modular type lockable feature socket dulymade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating , includingall as per pre approved by Engineer in charge,making connections, testing etc. as required. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR |
| 40 | 6 A3/5 pin shuttered socket |
| 41 | 6/16 Ashuttered socket |
| 42 | Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (fordouble door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR |
| 43 | Metal door (single phase) IK-09 and IP-43 with Metal end box |
| 44 | 8 Way (8+2) |
| 45 | Metal door (Three phase) IK-09 and IP-43with Metal end box |
| 46 | 6 Way |
| 47 | Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947- 2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR |
| 48 | Single pole MCB (With B/C curve tripping Characteristics) |
| 49 | 6 A to 32 A rating |
| 50 | Four pole MCB (With B/C curve tripping Characteristics) |
| 51 | 40 A rating |
| 52 | Providing & Fixing of 240/415 V factory fitted RCBO with overload, short-circuit and earth leakage protectionwith ISI marked (IS12640-2)/ conforming to IEC 61009-1, breaking capacity 10 KA,provision for pad lock, min. Electrical operation 10,000 upto 63 A rating , minimum phase termination capacity of 35sq.mm. , IP 20 contact protection with existing distribution board / sheetincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR |
| 53 | Two pole 100/300mA sensitivity |
| 54 | 6A-32 A rating |
| 55 | Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR |
| 56 | 4 x 6.0 sq.mm |
| 57 | NON-BSR ITEMS |
| 58 | Supply, Installation, Testing & Commssioning of Layer 2 Managed 24-Port Gigabit Smart Managed Switch along with 24 x 10/100/1000BASE-T ports 4 x Gigabit RJ45/SFP Combo ports Advanced L2 switching and security features L2+ Static Routing along withL2 features, including IGMP snooping, port mirroring, Spanning Tree Protocol (STP), and Link Aggregation Control Protocol (LACP) in respect to approved make - Dlink / Cisco / Avaya |
| 59 | Supply, Installation, Testing & Commssioning of 10-Port Gigabit Smart Managed PoE Switch having 8 x 10/100/1000BASE-T PoE ports 2 x Gigabit SFP ports, Advanced L2 switching and security features, L2+ Static Routinmanagement user interface with 130W PoE budget having Layer 2 Features 8K or 16K MAC address table, IEEE 802.1D STP, 802.1w RSTP, and 802.1s MSTP, Loopback detection Supports IEEE 802.3ad Link Aggregationin respect to approved make - Dlink / Cisco / Avaya |
| 60 | Supply, Installation, Testing & Commissioning of Single Mode Gigabit SFP Modules Small Form factor Pluggable (SFP) Multi-Source Agreement (MSA) specification compliant IEEE 802.3z standard, Hot pluggable, TTL signal detect indicator along with Metal enclosure reduces EMI in respect to approved make - Dlink / Cisco / Avaya |
| 61 | Supply, Installation Testing & Commissioning of 10 KVA Online UPS,I>0.99 I/P PowerFactor, 160-280 VAC I/P Voltage Range @ rated Load, 46-54 HZ I/P frequecy, 0 to 40 Degree Operation Tem, upto 93% Double Conversion Efficiency, 192V DC Voltage, Automatic bypass (inbuilt), LCD Display showing UPS parameters, AUDIBLE ALARM: Mains Failure alarm, Low Battery alarm, UPS warning, Overload, Fault & Bypass mode,with 26 ah x 16 nosSMF Batteries, O/P Voltage: 230 V, DURING MAINS -VOLTAGE VARIATION (Static):+/-1% (Should not be more than specified values), OVER LOADING: upto 130% for 05 minutes & upto 110 % for 10 min, UPS should be GenSet Compatible, ISO 9001, ISO 45001 and ISO 14001 Certification, BIS (In name of UPS OEM), ROHS, Type Test Report of the Product Series, MS Rack Required in respect to approved make - Numeric/APC/Emerson |
| 62 | Supply, Installation, Testing & Commissioning of 65\" Network & Wifi Enabled LED with Diagonal Size 65\" Panel Type VA Resolution 3,840 x 2,160, Brightness (Typical) 300 nit Contrast Ratio 4,000 : 1 Viewing Angle (H/V) 178°/178°, having operating system Crystal processor 4K, HDMI 2.0 (3), USB 2.0 x 2 RJ 45 & Wifi Enabled, BIS/UL Certified with linux based OEM owned operating system in respect to approved make - Barco/ Samsung BE65 / Christie |
| 63 | Supply, Installation, Testing & Commissioning of Local Fabricated Outdoor casing for Protection & with required mounts to hang from MS angles with fabrications as required |
| 64 | Supply, Installation, Testing & Commissioning of 32\" indoor Network & Wifi Enabled LED with Diagonal Size 32\" Panel Type VA Resolution 1920X1080 Pixel Pitch (HxV)0.36375 x 0.36375 (mm) (AUO) Brightness (Typical) 440 nit Contrast Ratio 5,000 : 1 Viewing Angle (H/V) 178°/178°, H-Scanning Frequency 30 ~ 81kHZ kHz (HDMI), V-Scanning Frequency 48 ~ 75HZ kHz (DP) Maximum Pixel Frequency 148.5MHz MHz, HDMI In 3, USB, 2, RS232 In & Out, RJ 45 & Wifi Enabled, BIS/UL Certified with linux based OEM owned operating system in respect to approved make - Barco/ Samsung QM32C / Christie |
| 65 | Supply, Installation, Tesing & Commissioning of Token Dispensing Machine along with Integrated Auto Cutter Thermal Printer 60 Meter Thermal Paper Roll Capacity Micro Controller with, API Integration, Series wise Token Slip Dispensing, Wired and wireless operations Midnight Reset, Heavy duty Auto cutter Thermal Printer Configurable up to 4 services. Dynamic Print Settings Android App, Browser Based Operations, Summary report in single print, MS Enclosure With EPOXY Based, Powder Coated Paint, Power supply 230 v Printer specifications Classic Print speed :230 mm/s Interface :serial +USB along with 10 numbers of paper rolls -- Make -Netsol IT |
| 66 | Supply, Installation, Testing & Commissioning of WI FI ACCESS POINT with Indoor, dual radio, 5GHz and 2.4GHz 802.11ax 2x2 MIMO Up to 256 associated client devices per radio with • 802.11b: Direct-sequence spread-spectrum (DSSS) Orthogonal frequency-division multiplexing (OFDM) • 802.11ax: Orthogonal frequency-division multiple access (OFDMA) with up to 8 resource units, along with 802.11n/ac packet aggregation:A-MPDU, A-MSDUConfigurable in increments of 0.5 dBm along with • Auto-sensing link speed (10/100/1000BASE-T) and MDI/MDX • POE-PD: 48Vdc (nominal) 802.3af/at POE (class 3 or 4) • 802.3az Energy Efficient Ethernet (EEE) along with Visual indictors (two multi-color LEDs forSystem and radio status in respect to approved make - ARUBA AP-505 |
| 67 | Supply, Installation, Testing & Commissioning of label printer with Printing Method, Thermal Line Printing – Direct, Thermal & Thermal Transfer, Resolution 203 DPI, Print Speed, Max. 150 mm/s, Print width Max 108 mm, CPU 32 bit RISC CPU, Interface USB + serial Paper Sensor, Transmission sensor removable, Reflection sensor removable 1D Barcode, Code 3 of 9, UPCA,UPCE, Interleaved 2 of 5, Code 128,EAN 13, EAN 8, HBIC39 code with check out,codabar industry CODE 25,storage and transportation code, UPC2,UPC5, Code 93, UCC/EAN, Matrix 25, Postnet code, etc in respect to approved make - Make TVS LP 46 NEO |