Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 10-04-2025 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 17-04-2025 |
| Sl. No. | Item Description |
| 1 | M&L for taking down unserviceable geyser of 25 Ltr capacity from existing position by disconnecting Elect/ water connectioions, from any position, locations and replacing the following unserviceable parts as mentioned below: - |
| 2 | (i) S&F in repairs thermostat suitable for 25 ltr storage type Vertical water heater ISI mark as per existing one complete all as specified and directed. |
| 3 | (ii) S&F in repairs LED indication lamp suitable for Geysers in roud/ rectangular shape complete all as specified and directed. |
| 4 | (iii) S&F in repairs Geyser assembly suitable to fix thermostat, heating elements as of the existng size suitable for 25 ltr capacity geyser including suitable washers, clamps with bolts & nuts suitable for 06/09 hole complete all as specified and directed. |
| 5 | (iv) S&F in repairs fusible plug suitable for 25 ltr capacity Geysers as per existing complete all as specified and directed. |
| 6 | (v) Taking down unserviceable bottom/ top cover plates (2 half) and S&F with new bottom/ top cover plates with machine coloumns of Geyser 25 ltr capacity complete all as specified and directed. |
| 7 | (vi) S&F in repairs steel water tank suitable for 25 ltr capacity water heater vertical type as per existing model and size complete all as specified and directed. |
| 8 | (vii) S&F safety plug suitable for 25 ltr capacity vertical type water heater as per existing model/ make complete all as specified and directed. |
| 9 | (viii) S&F in replacement of M S heavy duty fabricated frame suitable for holding water tank of 25 ltr capacity geyser, as per sample and existng shape and size including suitable hole for mounting the Geyser complete all as specified and directed.Note: Sample can be taken for the geyser by the contractor from concerned JE E/M sub division before quoting the rate. |
| 10 | (ix) S&F in replacement heating element 2 KW triangle type suitable for 25 ltr capacity vertical type water heater ISI mark. Make: Theeta complete all as per existing one and as directed. |
| 11 | (x) S&F glass wool heat insulation superior quality suitable for geyser ofCapacity 25/35/50 ltr complete all as directed. |
| 12 | (xi) S&F outer cover in replacement suitable for 25 ltr capacity vertical water heater as per existing model heavy duty complete all as specified and directed. |
| 13 | (xii) Supply only nuts, bolts, washers suitable of existing size and model suitable for fixing of Geyser assembly with geyser tank complete. |
| 14 | (xiii) S&F PVC connection mesh type for HOT/ cold water supply 2\" long heavy duty ISI mark as per sample complete all as specified and directed. |
| 15 | M&L for point wiring complete with stranded copper conductor 4 Sqmm size (Nominal area) PVC insulated unsheathed FRLScable 1100 volts grade confirming to IS: 694 drawn in and including medium grade concealed PVC conduit confirming toISI marked not less than 25mm dia with concealed sunk-in pressed steel terminal boxes of required size not less than 1.2 mm thick factory made and painted with stove enamelled black paint top cover 2.80 mm thick plastic laminated sheet of required colour fixed with brass screwes and cup washers including single core stranded copper conductor 4 Sqmm PVC insulated unsheathed cable as earth wire to common earth and connected to earth dolly drawn in same concealed conduit complete all as specified for one 6 pin socket outlet two in one 16/6 Amps on an independent board. (for geysers point)Note : 1)Rates are deemed to be included for chases of conduit and sunking for boxes cutting and making holes in wall/floor for passing in or through conduit. No Extra payment will be done on this account |
| 16 | -Ditto- but with cable 2.5 Sqmm and earth continuity conductor of 2.5 Sqmm stranded copper unsheathed complete all as specified and as directed. Note : 1)Rates are deemed to be included for chases of conduit and sunking for boxes cutting and making holes in wall/floor for passing in or through conduit. No Extra payment will be done on this account |
| 17 | Supply and fixing switch socket combination 5 Amps/16 Amps, 5 in 1, flush type in replacement all as specified and directed at site. |
| 18 | Supply and fixing in replacement of MCB signle pole 6-32 Amps 230 volts \"C\" series complete all as specified and as directed. |
| 19 | Supply & fix in replacement of SPN enclosure with two pin and earth plug and socket complete with one SP MCB 20 Amps complete all as specified and directed by Engineer-in-Charge. |
| 20 | Supply and fixing in repairs stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc as required all as specified and directed at site. |
| 21 | S&F submain wiring withunsheathed multi-stranded FRLS Grade copper conductor cable 1100 volts grade drawn through in and including PVC rigid conduit medium grade of not less than 25mm dia with conduit accessories and concealed in wall/surface of ceiling for two runs of 6 Sqmm single core HR Grade and one run of 6 Sqmm PVC insulated copper conductor for earth continuity wire between main DB to Sub main DB complete all as specified and as directed.Note :- Two run of single core cable with one run of earth continuity conductor and PVC conduit and accessories will be measured as one length including cutting chasing in wall complete.Note 1: Rates are deemed to be included for chases of conduit and sunking for boxes cutting and making holes in wall/floor for passing in or through conduit. |
| 22 | S&F submain wiring withunsheathed multi-stranded FRLS Grade copper conductor cable 1100 volts grade drawn through in and including PVC rigid conduit medium grade of not less than 25mm dia with conduit accessories and concealed in wall/surface of ceiling for two runs of 4 Sqmm single core HR Grade and one run of 4 Sqmm PVC insulated copper conductor for earth continuity wire between main DB to Sub main DB complete all as specified and as directed.Note :- Two run of single core cable with one run of earth continuity conductor and PVC conduit and accessories will be measured as one length including cutting chasing in wall complete.Note 1: Rates are deemed to be included for chases of conduit and sunking for boxes cutting and making holes in wall/floor for passing in or through conduit. |
| 23 | S&F cable copper flexible 3 Core cicular type 2.5 sqmm heavy duty complete all as specified and directed. |
| 24 | S&F cable copper flexible 3 Core cicular type 4 sqmm heavy duty complete all as specified and directed. |
| 25 | Supply and fixingball bearing suitable for ceiling fan,wall mounted fan, exhaust fan, pedestal fan of same size as that of existing defective one complete all as specified and as directed. |
| 26 | Supply and fixing bush bearing suitable for ceiling fan,wall mounted fan,exhaust fan and pedestal fans complete all as specified and as directed. |
| 27 | M&L for repairing of fan stator sheet as required complete as specified and directed by Engr-in-charge |
| 28 | S&F screws as per sample for fixing of fan blades with fan stator complete all as specified and as directed by Engr-in-charge. |
| 29 | M&L for Cleaning and preparing the surfaces of ceiling fan removing the grease, carbon dust over the fans and painting with one coat of synthetic enamel paint of approved colour with brush painting and writing MES number on the fan all as directed by Engineer-in-Charge. |
| 30 | M&L for Rewinding the stator complete with super enamelled bare copper conductor with the same size and number of turns as that of the old one,insulating, varnishing and pre heating for the following :- |
| 31 | Ceiling fan 1200mm/1400mm sweep |
| 32 | Exhaust fan 200mm / 300 mm sweep |
| 33 | Exhaust fan above 450mm sweep |
| 34 | S&F Cotter Pin/Split Pin Ceiling fan Bush |
| 35 | S&F Down Rod |
| 36 | S&F Ceiling fan cycle |
| 37 | M&L for Removing the damaged and corroded exhaust fan louvers and replacement with new louvers of following sizes:- |
| 38 | Exhaust fan 200mm upto 300mm sweep |
| 39 | Exhaust fan above 300mm upto 450mm sweep |
| 40 | M&L for Removing the damaged , corroded exhaust fan blades and replaced with new blades of size:- |
| 41 | Exhaust fan 150/200mm / 250mm sweep as per sample |
| 42 | Exhaust fan above 300mm / 450mm sweep |
| 43 | Material and labour for shifting & fixing of old serviceable exhaust fan and makingcircular opening by cutting stone wallin any size and shapecomplete with i PCC (1:2:4) B0 12.5mm graded aggregate and grouting 04 Nos bolts of size not less than 10mm dia and 100mm long with nut & washer and making good to distrubed surface..(Note:- Neccessary support in high rise building (ground floor to third floor)forworking from out side shall be deemed inclusive). |
| 44 | Material and labour for Shifting & fixing ceiling fan with down rod including necessary holes, nuts and bolts, pin as directed by Engineer-In-charge. |
| 45 | Material and labour for fixing fan down rod 15mm dia 2 ft long including necessary holes, nuts and bolts, pin in replacment of old u/s down rod as per site requirement all as directed by Engineer-In-charge. |
| 46 | Material and labour for fixing fan canopy in replacment of old broken u/s canopy as per site requirement all as directed by Engineer-In-charge. |
| 47 | S&F ceiling fan blades suitable for 1200 mm sweep ceiling fan as per samplein replacment of old broken u/s ceiling fan blade as per site requirement all as directed by Engineer-In-charge. |
| 48 | Taking down ceiling fan (C/F of any size/make), cleaning its dust properly oiling and hanging the same back to its original position including connecting the wire to ceiling rose etc complete after completing the wiring all as specified and as directed by Engr-in-Charge.Note :- (i) The spares like cotter pin, nuts & bolts, rubber bush & hooks etc defective/damage deemedto be replaced and make the ceiling fans functional. The rates quoted for the same deemed to be included for the above job. |
| 49 | Taking down exhaust fan and re-connecting up including provision of cable from ceiling rose to exhaust fan after cleaning all dust complete all as specified and as directed.Note :- (i) The spares like nuts & bolts etc defective/damage deemed to be replaced and make thefans functional. The rates quoted for the same deemed to be included for the above job. |
| 50 | Supply & fixcapacitor of 2.5 mfd complete all as specified and directed. |
| 51 | -Ditto- but 3.15mfd complete all as specified and directed. |
| 52 | -Ditto- but 4.0 mfd complete all as specified and directed. |
| 53 | Supply & fixcapacitor of 0.85/1.00 mfd complete all as specified and directed. |
| 54 | Supply and fixing Rigid non-metallic 20 Dia in mm PVC conduit exclusive of boxes (junction/terminal) but inclusive all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. complete all as specified and as directed. |
| 55 | Suply and fixing and connecting flexible copper twisted twin core of size 23/.00076 complete all as specified and directed by Engineer-in-Charge. |
| 56 | S & F heavy dutyPVC cable1100 volts grade , insulated aluminium multi stranded conductor, twin core wire of size 4 sqmm complete all as specified and as directed. |
| 57 | S & Fheavy duty PVCcable , 1100 volts grade insulated aluminium multi stranded conductor, twin core wire of size 6 sqmm complete all as specified and as directed. |
| 58 | Supply and fixingrubber shackle complete with bolt, nut, split pin complete all as specified and as directed. |
| 59 | Material and labour for fixing plastic body exhaust fan blades for 250 mm sweep in replacment of old u/s platic body exhaust fan blade as per site requirement all as directed by Engineer-In-charge. |
| 60 | Material and labour for fixing fan motor with venitilated plastic cap suitable for plastic body exhaust fan for 250 mm sweep in replacment of old u/s motor of exhaust fan all per site requirement all as directed by Engineer-In-charge. |
| 61 | Supply and fixing surface mounting frame less panel, square in shape, ABS housing and PC diffuser, inbuilt driver, 12 Watts complete all as directed. |
| 62 | S&F in replacement plastic frame suitable for 250 mm sweep ventilation fan as per existing make/ model complete all as specified and directed by engr-in-charge. |
| 63 | S&F in replacement plastic frame suitable for 200 mm sweep ventilation fan as per existing make/ model complete all as specified and directed by engr-in-charge. |
| 64 | S&F ventilation fan motor suitable for 300 mm sweep metal fans having double ball bearing, heavyduty motor suitable for existing make/model complete all as specified and directed by engr-in-charge. |
| 65 | S&F ceiling fan 1250mm sweep, aerodyanamic profile blades for silent operation with high twist angles leading to high air delivery, rust free re-inforced ABS blades, dust and mark resistant caoting pearl white Stealth Air complete all as specified and directed. |
| 66 | S & Fplug top 16 Amps, 240 volts complete all as specified and as directed. |
| 67 | Supply and fixing inrepair modular stepped type fan regulator,suitable for 02/01 module complete all as specified and directed. |
| 68 | SOLAR WATER HEATER |
| 69 | M&L for removal and un-installation of existing solar leaked tank from the system and refixing after necessary repair to make it serviceable in all respect. |
| 70 | S&F, installation, testing and commissioning of new steel solar water heater tank of 200 litres capacity complete in replacement of existing unsserviceable/leaked solar tank with insulation and inlet and outlet connection for 6 Nosaccn and over flow pipes including all GI fittings i.e GI Socket, Elbow, Union, Plug, rubber gasket etc as required at site complete all as specified and directed. |
| 71 | M&L De-scaling of existing solar flat plate collector brazing where ever required, all fittings and gaskets in place complete all as directed. |
| 72 | S&F insulationof existing hot water line with 9mm Nitrile insulation for better performace of the solar water heater complete all as directed. |
| 73 | SITC for fresh hose pipe for the solar water heaer system from solar water tank to collectors complete all as directed. |
| 74 | Repair/Replacement of electrical back up heating element 3 KW suitable for Solar heating system including electrical connection with DB and all accessories required for smooth functioning electrical backup complete all as specified and directed. |
| 75 | M&L for submain wiring in PVC conduit 2 x 6 Sqmm and 1 x 6 Sqmm as earth wire copper conductor multistanded, as PVC conduit not less than 20mm dia complete all as specified and directed. |
| 76 | INT WIRING |
| 77 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixtures and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking into credit and making good disturbed surfaces of walls, floors etc all as directed. |
| 78 | M&L for point wiring complete with 1.5 Sqmm 1100 volts grade single core FRLS PVC insulated unsheathed cable with multi stranded copper conductor as per IS732 (1989)drawnthrough and including PVC casing & capping of suitablesizeon walls/ ceiling etc and including provn of 1.5 sqmm PVC insulated Multistranded copper cable asearth continuity conductor connected to common earth dolly including 1.22 mm thick pressed steel terminal boxes of suitable thickness, 3mm thicklaminated sheet cover to house switch/regulators etc for all as specified and directed. |
| 79 | (a) One fan/light /bell point controlled by one switch/bell push |
| 80 | (b) One switch socket outlet 5 Amps on independent board |
| 81 | (c) One socket outlet 5 Amps on the same board |
| 82 | All as per Item No 53 here-in-before but with 2.5 SqmmPVC insulated multistranded copper conductor cable including 2.5 sqmm PVC insulated copper cable asearth continuity conductorfor one switch socket outlet 15 Amps on independent board all as directed. |
| 83 | All as per Item No 53 here-in- before but with 4 Sqmm PVC insulatedmultistranded copper conductor with 4 sqmm cable as earth continuity conductor forPower Socket on independent board all as directed. |
| 84 | M&L for point wiring complete with 1.5 Sqmmsingle core FRLS PVC insulated unsheathed cable 1100 V grade multi stranded copper conductor as per IS732 (1989)drawn through non metallic rigid PVC conduit and accessories in surface of walls/ceilings/concealedin wall including 1.5 Sqmm dia multistranded copper cable as earth continuity conductor connected to common earth dolly, including 1.22 mm thick pressed steel terminal boxes of suitable thickness, 3 mm thicklaminated sheet cover to house switch/regulators etc all as specified and directed. |
| 85 | (a) One fan/light /bell point controlled by one switch/bell push |
| 86 | (b) One switch socket outlet 5 Amps on independent board |
| 87 | (c) One socket outlet 5 Amps on the same board |
| 88 | All as per Item No 56 here-in-before but with 2.5 SqmmPVC insulated multistranded copper conductor cable including 2.5 sqmm PVC insulated copper cable asearth continuity conductorfor one switch socket outlet 15 Amps on independent board all as directed. |
| 89 | All as per Item No 56here-in- before but with 4 Sqmm PVC insulated multistranded copper conductor with 4sqmm cable as earth continuity conductor for power Socket on independent board on the existing/new PVC surface conduit all as directed. |
| 90 | M&L for sub main wiring but using two single core multistrandedPVC insulated copper conductor FRLS Cable of size 4 sqmm 1100 volt grade drawn into PVC Cassing capping of suitable size including 4.0 sqmm. PVC multi standard copper conductor FRLS cable in green colour for continious earthing including chislling/cutting of wall, floor, making hole through wall & making good disturbed surfaces of wall/floor/ceiling to match with existing surface including taking down old unserviceable/burnt wiring of any type or size all as directed by Engr-in-Charge..Note: Two single core cable, earth wire and PVC conduitshall be measured as one length. |
| 91 | Ditto item no 59 Above but of 6 Sqmm size wire. |
| 92 | Supply and fixing in repair ceiling rose surface bakelite with three terminals complete including taking down rusted metal box and necessary platering work and finish with existing wall paint all as specified and directed. |
| 93 | Supply and fixing in repairs switch piano type one way 6 Amps flush type ,240 voltAC all as specified and directed. |
| 94 | Supply and fixing in repairssocket outlet 2 in1,3 pin 5 Amps all as specified and directed. |
| 95 | Supply and fixing in repairs switch socket combination(SSC)2 in 1, 3 pin, 5Ampsflush type ,240voltAC with gang box all as specified and directed. |
| 96 | Supply and fixing in repairs switch piano type 16 Amps flush type ,240voltAC all as specified and directed. |
| 97 | Supply and fixing in repairs socket outlet 2 in 1, 3/ 5 pin16 Amps flush type all as specified and directed. |
| 98 | Supply and fixing in repairs switch socket combination(SSC)2 in 1, 3/5 pin, 16 Ampsflush type ,240voltAC with gang box all as specified and directed. |
| 99 | Supply and fixing in repairs Bell push, flush type, 6 Amp flush type ,240voltAC all as specified and directed. |
| 100 | Supply and fixing in repairsswitch piano type two way 6 Amps flush type ,240 voltAC all as specified and directed. |
| 101 | Supply and fixing in repairs Bell push, Modular type, 6 Amp flush type ,240 voltAC all as specified and directed. |
| 102 | Supply and fixing in repair modular switch 1 way 6A 1 module complete all as specified and directed. |
| 103 | Supply and fixing inrepair modular switch 2 way 6A 1module complete all as specified and directed. |
| 104 | Supply and fixing inrepair modular socket 6A2/3 pin combined 2 module complete all as specified and directed. |
| 105 | Supply and fixing inrepair modular socket 6A /16A2/3 pin combined 2 module complete all as specified and directed. |
| 106 | Supply and fixing inrepair modular stepped type fan regulator,suitable for BLDC fan (any make 01 module complete all as specified and directed. |
| 107 | S & Fix in repairstepped type electronic fan regulator 80/100 watt ,240 voltflush type on the existing phenolic laminated sheet complete all as directed. |
| 108 | Supply andfix in repairelectric bell Ding Dong,AC 230 volts complete all as specified and directed. |
| 109 | S/F Lamp holders insulated body card grip pattern suitable for batten/angular including taking down old unserviceable complete all as specified. |
| 110 | Supply and fixing in repairModular white cover plate with frame 1module complete all as specified and directed. |
| 111 | Supply and fixing in repair Modular white cover plate with frame 2 module complete all as specified and directed. |
| 112 | Supply and fixing in repair Modular white cover plate with frame 3 module complete all as specified and directed. |
| 113 | Supply and fixing in repairModular white cover plate with frame 4 module complete all as specified and directed. |
| 114 | Supply and fixing in repairModular white cover plate with frame 6 module complete all as specified and directed. |
| 115 | Supply and fixing in repair Modular white cover plate with frame 8 module complete all as specified and directed. |
| 116 | Supply and fixing in repair metal flush box 1/2 modulecomplete all as specified and directed. |
| 117 | Supply and fixing in repair metal flush box 3 modulecomplete all as specified and directed. |
| 118 | Supply and fixing in repair metal flush box 4 modulecomplete all as specified and directed. |
| 119 | Supply and fixing in repair metal flush box 6 modulecomplete all as specified and directed. |
| 120 | S&F domestic surface mounting 1 gang box for fixing of socket outlet and switches complete all as specified and directed. |
| 121 | S&F domestic surface mounting 2 gang box for fixing of socket outlet and switches complete all as specified and directed. |
| 122 | S&F domestic surface mounting 3 gang box for fixing of socket outlet and switches complete all as specified and directed. |
| 123 | S&F domestic surface mounting 5 gang box for fixing of socket outlet and switches complete all as specified and directed. |
| 124 | S&F domestic surface mounting 4 gang box for fixing of socket outlet and switches complete all as specified and directed. |
| 125 | S&F domestic surface mounting 6 gang box for fixing of socket outlet and switches complete all as specified and directed. |
| 126 | S&F domestic surface mounting 8 gang box for fixing of socket outlet and switches complete all as specified and directed. |
| 127 | S & F sheet metal enclosures for double door distribution boardfactory made duly painted 12 way SPN and neutral 240 v with 200 amps rated bus bar , suitable for fixing MCB /Isolators all as specified. |
| 128 | S & F sheet metal enclosures for double door distribution boardfactory made duly painted 8 way SPN and neutral 240 v with 200 amps rated bus bar , suitable for fixing MCB /Isolators all as specified. |
| 129 | S & F sheet metal enclosures for double door distribution boardfactory made duly painted 4 way SPN and neutral 240 v with 200 amps rated bus bar , suitable for fixing MCB /Isolators all as specified |
| 130 | S & F sheet metal enclosures for double door distribution boardfactory made duly painted 4 way TPN and neutral 415Vwith 200 amps rated bus bar , suitable for fixing MCB /Isolators complete all as specified and directed. |
| 131 | S & F MCCB 125 Amps,4 pole, Breaking capacity 16 KA, 415 V adjustable type all as specified of capacity complete all as directed. |
| 132 | S & F MCCB 100 Amps,4 pole, Breaking capacity 16 KA, 415 V adjustable type all as specified of capacity complete all as specified and directed. |
| 133 | Supply and fixingminiature circuit breaker (MCB) of single poles and current carrying capacity 6 to 32 AMP240V, 10 KA \"C\" curve , in the MCB DB Complete with connection testing and commissioning. |
| 134 | Ditto same as item no 102 butSPN 32 Amps |
| 135 | Ditto same as item no 102 butSPN 40 Amps. |
| 136 | Ditto same as item no 102 butTPN 63Amps. |
| 137 | Taking down old unserviceablefitting and S & F wall mounted extruded aluminium housing high quality indoor batten LED tube light fitting 20 watt colour temperature 6500 K (4\" long) lumen 2000 -3000, PF> 0.9, THD less 15%diffused connecting with three core flexible copper wire from connecto to ceiling rose/angle holder as per existing site requirement as directed by Engr-in-charge. |
| 138 | Ditto item no -106 above but 10 Watt( 2\" long) complete all as specified and directed by Engr-in-Charge. |
| 139 | Taking down old unserviceablefitting S & F Recess mounting LED flat panel light fitting 36 watt,2 x 2 , 600mm x 600 mm size with efficient LEDslumen 2000 -3000, PF> 0.9, THD less 15% including taking down unserviceable fitting of any type and make all as specified and directed. |
| 140 | M & L for repair and replace of unserviceable LED driver suitable for 36/40 watt LED panel light fitting 2 x 2 size on siteall as specified and directed by Engr-in-Charge. |
| 141 | Taking down old unserviceable Bldg security light S&F fix high efficent LED building security light30 watt , 230 V ,lumen 2000 -3000, PF> 0.9, THD less 10%,made of pressutre cast aluminuim housing with high power LEDs, lens and touughned glass IP 66 connecting with three core flexible copper wire from connecto to ceiling rose complete all as specified and directed by Engr-in-Charge. |
| 142 | S & F in repair bracket for mounting building security lightmade out of 40 mm dia Light Grade GI pipe bend inanglewith holding MS clampstwo nos each bracket ox size 25x3 mm includingscrewetc for fixing all as specidfied and directed by Engr in charge |
| 143 | M & L for earthing complete in repairs with galvansihed steel earth plate electrode 600 mm x 600 mm x 6.3 mm thick buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of plate not less than 1.5 m below normal ground level connected to 4.0 mm dia galvansihed earth lead wire by means of nuts bolts check nuts and GI washers includingPCC pit in PCC 1:2:4 type B-1 RCC cover 20 mm dia (medium grade) GI watering pipe with funnel wire mesh and protection pipe of GI of suitbale size upto 7.5 mtr length including charcoal black cotton soil as required at site to achieve the earthing result and common salt, excavation earth work etc in any type of starta complete all as shown in electrical plate No 3 as specified, GI wire suitable size and length for continuity earth wire from test point to main distribution Board and all as directed. (Note:(i) Rate for achieving required depth by compressor machine if required is deemed included in item unit rate. (ii) After earthing contractor should test the earth value and submit register for earth resistance result to Engr-in-Charge. ) |
| 144 | S&Fcopper flexible wire Single Core cicular type 1.0 sqmm heavy duty complete all as specified and directed. |
| 145 | S&F copper flexible wire Single Core cicular type 2.5 sqmm heavy duty complete all as specified and directed. |
| 146 | S&Fcopper flexiblewire Single Core cicular type 4 sqmm heavy duty complete all as specified and directed. |
| 147 | S&F copper flexible wire Single Core cicular type 6 sqmm heavy duty complete all as specified and directed. |
| 148 | S & F LED Bulbs of 07 watts including taking down complete all as specified and directed |
| 149 | S & F LED Bulbs of 09 watts including taking down complete all as specified and directed |
| 150 | Supply and fixing in replacement of defected/unsvl electronic meters temper proof LCD display with polycarbonate cover 230 V, 10-60Amp, accuracy class-I 50Hz, conforming to IS 13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWH complete all as specified and as directed. |
| 151 | Supply and fixing in replacement of three phase defected/unsvl electronic meters temper proof LCD display with polycarbonate cover 415 V, 10-60Amp, accuracy class-I 50Hz, conforming to IS 13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWH complete all as specified and as directed. |
| 152 | Excavation in trenches n exc 1.5 wide and n exc 1.5 m in depth for foundation etc or for laying cable etc n exc 10 Sqm on plan and n exc 1.5m in depth and getting out in soft/loose soil complete all as specified and as directed. |
| 153 | Returning filling in including spreading, leveling, watering and well ramming in layersexc 25 cm thick complete all as specified and as directed. |
| 154 | Removal of excavated material/surplus soil to a distance n exc 50m and depositing where directed at a level n exc 1.5m above the starting point complete all as specified and as directed. |
| 155 | Supply and filling river sand in trenches including spreading for cushioning of LT UG cable complete all as specified and as dirceted.Note : Punned down thickness shall be measured and paid . |
| 156 | M&L for sub class ‘B’ bricks old sizelaid flat dry in trenches over cable, across the direction of cable complete all as specified & directed . |
| 157 | Supply, laying and testing in replacement of cable XLPE insulated screened, PVC bedded galvanized steel strip or wire armoured electric power cable (heavy duty) with aluminium conductor 1100 Volts grade cross sectional area 3.5 core x 95 Sq mm. complete all as directed. Note : Provision of suitable double crimpped lugs and glands shall deemed to be included in quoted rates. |
| 158 | Ditto all as per item No 126 described here in before but 3.5 core 70 sqmm |
| 159 | Ditto all as per item No 126 described here in before but 3.5 core 50 sqmm |
| 160 | Ditto all as per item No 126 described here in before but 3.5 core 35 sqmm |
| 161 | Ditto all as per item No 126 described here in before but 4 core 25 sqmm |
| 162 | Ditto all as per item No 126 described here in before but 4 core 16 sqmm |
| 163 | Ditto all as per item No 126 described here in before but 2 core 10 sqmm |
| 164 | Taking up or down CI Pipesincluding all fittings such as spigot and socket ends, bends, belows tee etc laid complete in trenches all as specififed of sizes :- |
| 165 | (a) 80mm bore |
| 166 | (b) 100mm bore |
| 167 | (c ) 150mm bore, |
| 168 | (d) 200mm bore |
| 169 | Supply, Laying and Testing of cast iron pipes with spigot and socket ends and centrifugally cast class LA, in any length, laid in trenches complete all as specified and directed of followingsizes :- |
| 170 | (a)80mm bore |
| 171 | (b) 100mm bore |
| 172 | (c ) 150mm bore |
| 173 | (d)200mm bore |
| 174 | Laying,refixingand Testing of Oldcast iron pipes with , in any length, laid in trenches complete all as specified and directed of followingsizes :- |
| 175 | (a)80mm bore |
| 176 | (b) 100mm bore |
| 177 | (c ) 150mm bore |
| 178 | (d)200mm bore |
| 179 | Taking up or down steel tubing and connectionsincluding all fittings such asbends, belows tee, unions, sockets etc laid complete in trenches all as specififed of sizes :- |
| 180 | (a) 15mm bore |
| 181 | (b) 20mm bore |
| 182 | (c ) 25mm bore |
| 183 | (d) 40mm bore |
| 184 | (e) 50mm bore |
| 185 | (f)80mm bore |
| 186 | (g) 100mm bore |
| 187 | S & F in repair steel tubing and connectionsincluding all fittings such asbends, belows tee, unions, sockets etc laid complete in trenches all as specififed of sizes :- |
| 188 | (a) 15mm bore |
| 189 | (b) 20mm bore |
| 190 | (c ) 25mm bore |
| 191 | (d) 40mm bore |
| 192 | (e) 50mm bore |
| 193 | (f)80mm bore |
| 194 | (g) 100mm bore |
| 195 | Laying & refixingonly in repair steel tubing and connectionsincluding all fittings such asbends, belows tee, unions, sockets etc laid complete in trenches all as specififed of sizes :- |
| 196 | (a) 15mm bore |
| 197 | (b) 20mm bore |
| 198 | (c ) 25mm bore |
| 199 | (d) 40mm bore |
| 200 | (e) 50mm bore |
| 201 | (f)80mm bore |
| 202 | (g) 100mm bore |
| 203 | S & F in replacement Gun metal Gate valvewith iron wheel headscrewed both ends complete all as specified and as directed by the Engineer-in-Chargeof sizes :- |
| 204 | (a) 40 mm dia |
| 205 | (b)50 mm dia |
| 206 | (c ) 20 mm dia |
| 207 | (d)25 mm dia |
| 208 | S & Fcheck valve heavy duty of gun metal both end threaded and leaf spring loaded vertical typeincluding removing unserviceable foot valvefrom the suction pipe of the pump setcompleteall as specified and directed by Engr in chargeof following sizes:- |
| 209 | (a) 100 mm dia |
| 210 | (b) 80 mmm dia |
| 211 | (c) 50 mm dia |
| 212 | S & F in replacementCI non return valve completeall as specified and directed by Engr in charge of following sizes :- . |
| 213 | a) 150 mm dia |
| 214 | b) 100 mm dia |
| 215 | c ) 80 mmm dia |
| 216 | d) 50 mm dia |
| 217 | M & L for Cutting existing CI orsteel tubing of any sizefor alterations or additions and screwing all as specified and directed by Engg-in-charge |
| 218 | Demolition of existing valve pit and M&L for construction of valve pit consisisting of 230mm thick, old size brick masonry wall in cement mortar (1:6), PCC (1:4:8) type D2, using 40mm graded stone aggregete as in fondation, PCC (1:2:4) type B1, using 20mm graded stone aggregete in coping/bed, finished even and smooth, rendering 15mm thick in cement mortar (1:6) internally and 10mm thick in cement mortar (1:4) externally, finished even and smooth without using extra cement incuding three coats of white wash and earth work in any type of soil and including 3mm thick MS sheet cover fixed on 40mmx40mmx6mm thick angle iron frame ambeded in PCC coping with locking arrangement and mild steel hold fast & handle and duly painted with two coats of synthetic enamel paint over one coat of primer etc. complete all as shown on drawing NO TD/2004/26 Sh 1/1 to 1/3 and as specified and directed for the following sizes:- |
| 219 | (a) 900mm x 750mm x 900mm |
| 220 | (b) 900mm x 600mm x 1000mm |
| 221 | S & F in replacement Cast Iron sluice valve, class PN- 1.6 with flanged and drilled ends any pattern including necessary jointing and jointing materials complete (with rubber gaskets, bolts and nuts etc) completeall as specified and directed by Engr in charge includingtaking down the oldworn out sluice valve completeall as specified and directed by Engr in charge for the following sizes :- |
| 222 | (a) 150 mm dia |
| 223 | (b) 100 mm dia |
| 224 | (c ) 80 mm dia |
| 225 | M&L for earthling complete with galvanised iron earth plate electrode of the size 600 mm x 600 mm x 6 mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of earth plate not less than 1.5 mtr below normal ground level connected to galvanised iron strip 32 x 6 mm by means of bolts ,nuts.chuck nuts and washers of galvanised iron or .steel watering pipe of 20 mm bore , galvanised iron medium grade of 40 mm bore galvanised iron light grade of earth wire protection including all excavation earth work in any type of soil ,PCC pit with RCC pit cover , charcoal,salt,funnel complete all as shown in electrical plate No-3 of SSR Part-I & Testing on completion. Note: Quoted rates shall be including for earth strip with protection pipe upto 7.5 mtr length. |
| 226 | M&L for rectification of defective run lead joing by burning out lead joint in position including recovering lead and making new lead joint all as specified including bailing out water coming from defective joints by means of electric/diesel driven pump set, testing of the joint under full working pressure for the following CI Pipe lines all as directed by Engineer-in-charge. |
| 227 | (a) 80 mm |
| 228 | (b) 100 mm |
| 229 | ( c ) 150mm |
| 230 | (d) 200 mm |
| 231 | M&L for rectification of defective rubber gasket flanged joints including replacing rubber gasket, bolts, nuts and washers for the following CI/MS pipe line. |
| 232 | (a)200/150 mm dia |
| 233 | (b)100/80 mm dia |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy