Tender For Proposed Mgps Works Of 100 Bedded Icu (Air Conditioning Work) At Gsvm Medical College Kanpur. - Wiring For Light Point/Fan Point /Exhaust Fan Point /Call Bell/Sodium Point With 1.50 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable I, kanpur-Uttar Pradesh

Uttar Pradesh Projects Corporation Limited has published Tender For Proposed Mgps Works Of 100 Bedded Icu (Air Conditioning Work) At Gsvm Medical College Kanpur. - Wiring For Light Point/Fan Point /Exhaust Fan Point /Call Bell/Sodium Point With 1.50 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable I. Submission Date for this Tender is 26-03-2025. Medical Gas System Tenders in kanpur Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

48353135
Tender For Proposed Mgps Works Of 100 Bedded Icu (Air Conditioning Work) At Gsvm Medical College Kanpur. - Wiring For Light Point/Fan Point /Exhaust Fan Point /Call Bell/Sodium Point With 1.50 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable I
Open Tender
Indian
Uttar Pradesh
Kanpur
26-03-2025

Tender Details

Tender For Proposed Mgps Works Of 100 Bedded Icu (Air Conditioning Work) At Gsvm Medical College Kanpur. - Wiring for light point/fan point /exhaust fan point /call bell/Sodium point with 1.50 Sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium classPVC conduit,with modular switch, modular plate, suitable G I box and earthing the point with 1.50 sq. mm FRLS PVC insulated copper conductor single core etc. as required. 3 Wiring for Circuit/Submain wiring along with earth wire with the Following size FRLS PVC insulated copper conductor single core cable in surface / recessed medium classPVC conduit as required. 2 x 1.5 sq. mm + 1 x 1.5 sq. mm earth wire 4 Wiring for light / power plug with 2 x 4.00 sq. mmFRLS PVC insulated copper conductor single core cable in surface / recessed medium classPVC conduit, along with 1 No. 4.00 sq. mm FRLS PVC insulated copper conductor single core for loop earthing as required. 5 Supplying and fixing 5 A to 32 A rating, 250 / 415 V, 10 Ka, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. required.Single pole 6 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1010 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required. (a) Upto 35.00 sq. mm 7 (b) Above 185.00 sq. mm & Upto 400 sq.mm 8 Earthing with G I earth pipe 4.5 mtr. Long 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipeetc. with charcoal / coke and salt as required. 9 Providing and fixing 25 mm x 5 mm G I strip on surface or in recess for connections etc. as required. 10 Supply and fixing of 36 Watt to 46 Watt indoor Recess mounting LED Square Fitting for Armstrong Ceiling having Powder coated die cast aluminium housing body with extended heat sink and diffuser of Special Polycarbonate meterial and driver set complete in all respect. CAT-AAA 11 Supply & fixing of LED Tube Light with Metal heavy dutyBox type batten Light fitting 1 x 22 watt suitable for up to 1 x 22 watt LED Polycarbonate tube light complete including tube etc suitable for both surface & surface complete in all respects.(CAT: AAA) 12 S/F of sheet steel enclosure surface/Flush mounting fitted with 30 Amp 2 pin and earth metal clad scraping earth plug and socket complete in all respect. as directed at site by Engineer in chardge. Cat-A 13 S/F of surface/Flush mounting 4 ways V TPN distribution board with additional door without DPX3 160 MCCB complete in all respect, as directed at site by Engineer in charge. Cat.-B 14 S/F of 100 Amp 4 pole MCCB (16 KA) Thermal Magnetic release Cat - B 15 S/F of 40 Amp. SPMCB (10KA) C Curve 16 S/F ofCu Lugs & Gland complete in all respect. 17 Supply and Insttalation of Window A.C. suitable for opration of AC supply 230 volt and a bettery oprated remote.2 Ton 5 star rating Make: O General 18 Providing & Instalation of 5 KVA voltage stabilizers with range of 110-280 V of standard make V-Gaurd, Luminuos, stambh. 19 Supply and errection of factory fabricated and wired metal clad dust and vermin proof floor mounting M.S. Channel Base with bottom and top cable entreis Electrical control panel with TPN MCCBs (Four pole 25 KA with thermal magnatic release) switches complete and instrument chamber etc. complete in all respects. Theinstrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters(KVA, P.F.,KW etc.) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above instulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides. The MCCBs shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc.The job includes the grounting of the board as per directuons of Engineer-in-Charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubicle type switch board shall be cat A & B only.Incoming- 400 Amp MCCB = 01 No.Outgoing- 100 Amp MCCB = 04 No. 20 Supply of Al. Armoured Cable 35 sq.mm x 3½ core. 21 Supply of Al. Armoured Cable 120 sq.mm x 3½ core. 22 SITC of u PVC piping complete with fittings ,supports as per specifications and duly insulated with 6mm thick closed cell nitrile rubber insulationMake -Kisan,Prakash,supreme,prince32 mm dia 23 SITC of 25 mm x 5mm GI strip from earthelectrode directly in the ground as required complete in all respect (UPPWD SOR: 2018, 717) 24 S/F of 6 SWG GI wire for earthing 25 Providing and laying of electrical power supply from DB to outdoor unit with 6mm cable (with PVC conduit and 2x6mm+1x6mm cable with earth wire complete with labour and material. 26 Supply and fixing of 200 Amp 3 pole MCCB (25KA) Thermal Magnetic release SOR CAT A 1021 (M) 27 Supply and fixing surface/Flush mounting 12 ways SPN distribution board with additional metal door without MCB complete in all respect, as Direct by Engineer in Charge. SOR CAT A 1025 (A) 28 Supply and fixing of 6 Amp. To 32 Amp. DP MCB (10 KA) C Curve. CAT A 1009 29 Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750mm below ground level over a cushion of 75mm thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. 30 Supply and fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respect. The armouring of the cable shall be properly connected with the earth as per direction of Engineer-Incharge. 31 Supply and fixing of plain or pin type copper tin plated cable socket (lug) SOR 504 (F) 32 Direct Expansion air-conditioners with inverter technologySupply & installation of split /direct Expansion air-conditioners suitable for opertain on A/C supply single phase 50 Hz 230V olts with hermetically sealed compresoor with air cooled condenser with DC inverter technology, motor capacitor and start run capacitors, relay and over load protector internal unit, with one indoor and one outdoor unit. the condenser unit witll be placed outside the room on the terrace to avoid noise including standard lenght of suitable size coppere tubing covered with insulation tube. (High wall chorded/cordless) suitable capacity 3 core sheathed/PVC copper cable and battery operated wireless remote unit. 33 Providing & Instalation of 5 KVA voltage stabilizers with range of 110-280 V of standard make V-Gaurd, Luminuos, stambh. 34 SITC of outdoor units with MS Structure etc as per direction by Eng.-in-charge. 35 Coper piping for split AC 36 Supply and fixing Indoor to out door cable 37 SITC of u PVC piping complete with fittings ,supports as per specifications and duly insulated with 6mm thick closed cell nitrile rubber insulationMake - Kisan,Prakash,supreme,prince32 mm dia 38 SITC of 25 mm x 5mm GI strip from earthelectrode directly in the ground as required complete in all respect (UPPWD SOR: 2018, 717) 39 S/F of 6 SWG GI wire for earthing 40 Providing and laying of electrical power supply from DB to outdoor unit with 6mm cable (with PVC conduit and 2x6mm+1x6mm cable with earth wire complete with labour and material. 41 Supply and fixing of 200 Amp 3 pole MCCB (25KA) Thermal Magnetic release SOR CAT A 1021 (M) 42 Supply and fixing surface/Flush mounting 12 ways SPN distribution board with additional metal door without MCB complete in all respect, as Direct by Engineer in Charge. SOR CAT A 1025 (A) 43 Supply and fixing of 6 Amp. To 32 Amp. DP MCB (10 KA) C Curve. CAT A 1009 44 Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750mm below ground level over a cushion of 75mm thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. 45 Supply and fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respect. The armouring of the cable shall be properly connected with the earth as per direction of Engineer-Incharge. 46 Supply and fixing of plain or pin type copper tin plated cable socket (lug) SOR 504 (F) 47 Direct Expansion air-conditioners with inverter technologySupply & installation of split /direct Expansion air-conditioners suitable for opertain on A/C supply single phase 50 Hz 230V olts with hermetically sealed compresoor with air cooled condenser with DC inverter technology, motor capacitor and start run capacitors, relay and over load protector internal unit, with one indoor and one outdoor unit. the condenser unit witll be placed outside the room on the terrace to avoid noise including standard lenght of suitable size coppere tubing covered with insulation tube. (High wall chorded/cordless) suitable capacity 3 core sheathed/PVC copper cable and battery operated wireless remote unit. 48 Providing & Instalation of 5 KVA voltage stabilizers with range of 110-280 V of standard make V-Gaurd, Luminuos, stambh. 49 SITC of outdoor units with MS Structure etc as per direction by Eng.-in-charge. 50 Coper piping for split AC 51 Supply and fixing Indoor to out door cable 52 GST Extra as per applicable

Key Value

Document Fees
INR 5900 /-
EMD
INR 77000.0 /-
Tender Value
Refer document