| 1 | Taking down cement plaster on brick or stone walls etc incl raking out joints, hacking for key scrubbing down with water etc, complete all as specified and as directed. |
| 2 | Demolition of brick work or stone masonary built in cement mortar including all quoins arches pillars etc all as directed but excluding ashlar facings, dressed stone work and precast concrete articles, complete all as specified and as directed. |
| 3 | Demolition of cement concrete (reinforced) in any position andany thickness (below or above ground level), complete all as specified and as directed. |
| 4 | Demolition of cement concrete (un-reinforced) in ground floors and pavings any thickness (below or above ground level), complete all as specified and as directed. |
| 5 | M&L for rendering 10mm thick on fair faces of brick work or concrete surfaces finished even and smooth with using extra cement in cement mortar (1:4), complete all as specified and as directed. |
| 6 | M&L for dubbing out average 10mm thick in cement mortar 1:4 on irregular face of walls (when specifically ordered in writing), complete all as specified and as directed. |
| 7 | M&L for Rendering 15 mm thick on stone masonry surfaces or surface other than fair face of brick-work or on one side of lathing finished even and smooth with using extra cement in cement mortar 1:4, complete all as specified and as directed. |
| 8 | M&L for preparation of newly or previously untreated surfaces and finishing wall surfaceswith Acrylic Smooth exterior paint of required shade(Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm), complete all as specified and as directed. |
| 9 | M&L for complete removal of existing treatment on old wall surfaces & Finishing walls with Acrylic Smooth exterior paint of required shadeNew work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) new surfaces or old decorated surfaces, complete all as specified and as directed. |
| 10 | Preparation of old surfaces and applying one coat of cement base paint on walls surfaces /weather boardings, complete all as specified and as directed. |
| 11 | M&L for complete removal of existing treatment of surfaces and applying two coats of cement base paint on walls surfaces/weather boardings etc, complete all as specified and as directed. |
| 12 | M&L for cement concrete type D-2 1:4:8 (using 40mm graded aggregate) as in foundations, filling and mass concrete, complete all as specified and as directed. |
| 13 | M&L for brick work with sub class ‘B’ bricks straight or curved on plan n.exceeding 6m mean radius built in CM 1:4, complete all as specified and as directed. |
| 14 | M&L for walling or random rubble,uncoursed well bounded bedded and solidly hearted, built in cement mortar 1:6, complete all as specified and as directed. |
| 15 | M&L for providing cement concrete 1:2:4 type, B-1 (using 20mm graded crushed stone aggregate) as in coping, benching including all necessary form work, complete all as specified and as directed. |
| 16 | M&L for RCC (nominal mix) Type B-1 1:2:4 (20mm graded aggregate) as in Beams, cantilevers, bressummers, lintels over 1.5m span, complete all as specified and as directed. |
| 17 | M&L for precast cement concrete type B-0 1:2:4 (12.50mm graded aggregate)louvres and jallies, 25mm thick (measured solid), including all mouldings but excluding frame set in cement mortar 1:4, complete all as specified and as directed. |
| 18 | M&L Providing Precast cement concrete Type B-1 1:2:4 (using 20 mm graded crushed stone aggregate) in ladings, cover slabs (for manholes etc.) chullah hoods, chajjas, water throughs, mangers, shelves and similar articals with plain faces set in CM 1:6, complete all as specified and as directed. |
| 19 | M&L TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and ncluding mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and as directed. |
| 20 | Dismantling trellis work (Jafri) (One way), including taking as under of battens in trellis (posts and rails measuredseparately), complete all as specified and as directed. |
| 21 | Dismantling posts or struts (wood, steel or R.C.C.) embeded in cement concrete any section, including taking out embedded portion and making good disturbed ground, complete all as specified and as directed. |
| 22 | M&L for cement concrete type C-2 1:3:6 (using 40mm graded aggregate) as in foundations, filling and mass concrete, complete all as specified and as directed. |
| 23 | M&L second class soft wood clean sawn as in scantling in framed and fixed work etc, complete all as specified and as directed. |
| 24 | S&F 2nd class softwood 35mm x 10mm laths (fixed straight or diagonally) in two way trellis work with 50mm spaces in the clear, including 75mm x 50 mm fillet (notched to take ends of laths) all round and fixed, complete all as specified and as directed. |
| 25 | M&L forpreparation of newly or previously untreated woodensurfaces of any description, not otherwise described, over 10cm width or girth, applying two coatof synthetic enamel paint over a coat of pink primer, complete all as specified and as directed. |
| 26 | M&L forpreparation of old woodensurfaces of any description, not otherwise described, over 10cm width or girth, applying two coatof synthetic enamel paint, complete all as specified and as directed. |
| 27 | S&F Stainless steel 304 Grade railing top & bottom 40x40mm and horizontal 40x40mm centre to centre spacing 150mm and height upto 0.80m above GL including baluster 0.60m c/c complete including connected works rquired for fixing in floor PCC type B-1. 1:2:4 and making good of damage/ disturbed area and incl dismantling existing railing. Design and pattern as approved by Engr-in-Charge, complete all as specified and as directed. |
| 28 | M&L for 75mm thick cement concrete type C-2, 1:3:6 (40mm graded agrregate) as insub base of floors, finished even and fair over well/rammed/compacted earth, complete all as specified and as directed. |
| 29 | M&L for60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand, complete all as specified and as directed. |
| 30 | S & F Chequered cement concrete tiles 30 cm x 30 cm x 25 mm thick, with grey cement and pigments, set, jointed and pointed in neat cement slurry in floors including screed bed 15mm thick comple in CM 1:4, complete all as specified and as directed. |
| 31 | M&L for providing cement concrete type B-1, 1:2:4 (20mm graded aggregate) as in roof kerbs or mud stop, rounded or chamfered on edges, complete all as specified and as directed. |
| 32 | S&F mild steel posts & struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire etc. flat iron fillets for securing wire mesh etc including MS bars for tightning chain link necessary drilling bolting reveting etc. & similar work, fence with all nut & bolts complete conforming to Fe- 410 - or Fe-310-0, complete all as specified and as directed. |
| 33 | S&F Welded steel wire meshfebric fixed complete to steel members. Weight per sqm exc 4.00 Kg, complete all as specified and as directed. |
| 34 | S&F in repairs galvanized two strand steel barbed wire 2.24mm dia barbed with 2.00mm dia barbs at 75mm spacing and straining and fixing to any type of standard rail straining bolts incl. securing or tying at crossing with and provision of galvanized mild steel wire staples or steel pin etc, complete all as specified and as directed. (Each line of wire to be measured)complete all as specified and directed. |
| 35 | S&Fpre-painted galvalume aluminium zinc coataing GI based profilesteel sheet 0.50 mm thick of any colour having tnsile strength of 550 MPA as in roof covering/cladding to wall,fixed with self tappping screw incl dismantling, complete all as specified and as directed. |
| 36 | S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws incl dismantling, complete all as specified and as directed. |
| 37 | S&F galvanised,corrugated mild steel sheeting 0.63 mm thick with two corrugations side lap, fixed with coach screw and washers in roofs, walls etc incl dismantling, complete all as specified and as directed. |
| 38 | S&F 80 mm plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings(length and girth as fixed) with grade of zinc coating 120 gm incl dismantling, complete all as specified and as directed. |
| 39 | Preparation of old painted galvaniised surfaces (on CGI/PGI roof sheet)of any description not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint, complete all as specified and as directed. |
| 40 | Dismantling floor hearth wall tilling including cement mortar bedding, removing serviceable tiles to store and rubbish of f the permishes, complete all as specified and as directed. |
| 41 | M & L for glazed ceramic tiles in vertical surface 600x300x10 mm thick colour and design (as approved) in vertical surfaceand jointed in neat cement slurry and pointed in whiter or colour cement to match the colour of tiles over 15 mm thick cement plaster using CM (1:4) .complete all as specified and as directed. |
| 42 | M&L for 20mm thick granite (of any type) work (table rubbed and polished) for wall lining (veneering to wall) 12mm thick in cement mortar (1:3) and pointing with white cement (1:2) using marble dust with admixture ofpigment to match with shade of granite, complete all as specified and as directed. |
| 43 | Desludging of septic tank and manholes and capacity , size and depth including disposal of waste water and sludge through machanically/Using honey sucker machine and dividely store in covered container ert complete and removing the sludge in covered van/trolly out side the deffence land and taking off the manhole cover and placing in the same position after taking out sludge and covering pit minimum 30cm thick layer of earth work etc all as directed NOTES :- The unit rate for desludging usingHoney sucker Machine including hiring rate form any sources, Its operator , Hose required ( at least 50 mtr ) and Fuel etc. per trip of truck i e 3.0 to 4.05 Cum and the cost of dewatering shall also be included in the unit rate . Dewatering pit excavated in the unit area by contractor concern will liaise with the sources of honey Sucker Machine and during working any defects raised contractor will be responsible in all respect, complete all as specified and as directed. |
| 44 | Taking out silt ,liquid water sludge in solid/semi solid sae from septic tank /sump of any capacity , depth and size manually and removing the same to a distance of exe250m but not exc 500 m including depositing the sludge excavation in any type of soil with covering by earth over it and leaving the septic tank/sump clean etc, complete all as specified and as directed. |
| 45 | M&L Cleaning of blockage of sewage lines , manholes of any dia & any depth in any situation by way of cleaning of manholes sewage as well as rodding to and fro flushing with watering in sewage lines between seccessive manholes and keeping the systen functional connecting from floor traps , water closerts , soil waste and vent pipes , gully traps upto final drop/outlet into septic tanks / central sewage system by removing all blockages of any description in any situations manually or mechanically including cleaning of blockage of vents/solid/waste RWPof any description and any dia at Baramulla Garrison by employing daily one sweeper with helper along with required T&P complete all as specified and directed by Engr-in -charge |
| 46 | Demolition of brick masonary , stonemasonary etc built in cement mortar of any description including excavation and removal where ever required for embeded portion, complete all as specified and as directed. |
| 47 | Demolition of concrete in ground floor and pavings not exc 15 cm thickness (below or above ground level), complete all as specified and as directed. |
| 48 | M & L for PCC (1:4:8) type D2 ( using 40 mm aggregate ) as in mass concrete, complete all as specified and as directed. |
| 49 | M&L for brick work with sub class \"B brick (old size) straight or curved on plan exceeding 6 mtr mean radius built in CM 1:6, complete all as specified and as directed. |
| 50 | Demolition Concrete of any description and in any position not otherwise specifically provide for Cement concrete (unreinforced), complete all as specified and as directed. |
| 51 | M&L for pcc (1:2:4) type B1(using 20 mm grade aggregate ) as in copings etc including all necessaryform work, complete all as specified and as directed. |
| 52 | M&L for rendering 15 mm thick in CM 1:4 over brick or concrete surfaces finished even & smooth without using extra cement, complete all as specified and as directed. |
| 53 | Demolition and breaking up drain pipe 75/100 mm dia (AC, saltglazed, PVC or RCC pipes ) set in cement mortar or any description incl Excn of Earthwork, RFR, removal and making good, complete all as specified and as directed. |
| 54 | M&L for pcc (1:4:8) type D-1(using 40 mm grade aggregate ) as in bed to drain pipes including packing under and haunching against the side of pipes after these are laid tested for 150 mm bore of pipes, complete all as specified and as directed. |
| 55 | S&F 150 mmreinforced concrete pipes , class NP2 laid and jointed complete with collars, complete all as specified and as directed. |
| 56 | S&F in repairs 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints , laid in trenches or in floors fixed complete using PVC solvent and necessary testing etc, complete all as specified and as directed. |
| 57 | S&F in repairs 110mm bore PVC (SWR) bend/Tee etc, complete all as specified and as directed. |
| 58 | S&F in repairs 75 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints , laid in trenches or in floors fixed complete using PVC solvent and necessary testing etc, complete all as specified and as directed. |
| 59 | S&F in repairs 75mm bore PVC (SWR) bend/Tee etc, complete all as specified and as directed. |
| 60 | M&L for pre-cast reinforced cement concrete type B1(using 20 mm grade aggrigate ) set in cement mortar 1:6in landings cover slab (for manhole/ drain cover ) etc, complete all as specified and as directed. |
| 61 | M&L TMT bars 10mm dia and over cut to length , bend to shape required including cranking , bending spirally for hookings for cols ,hoking ends and binding with and including mild (aneeled) not less than 0.9 mm dia, complete all as specified and as directed. |
| 62 | M&L for providing and laying 80mm thick factorymade chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory ompaction by using plate vibrator, filling he joints with fine sand and cutting of paver block as per required size and attern, finishing and sweeping extra sand, complete all as specified and as directed. |
| 63 | S & F Chequered cement concrete tiles 30 cm x 30 cm x 25 mm thick, with grey cement and pigments, set, jointed and pointed in neat cement slurry in floors including screed bed 15mm thick comple in CM 1:4, complete all as specified and as directed. |
| 64 | M&L for providing cement concrete type B-1, 1:2:4 (20mm graded aggregate) as in roof kerbs or mud stop, rounded or chamfered on edges, complete all as specified and as directed. |
| 65 | Note:- Schedule of credit Rs 37,210.00 will be deducted from total amount quoted while accepting the bid. Details of schedule of credit is given in tender documents. |