Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Earth work in bulk excavation by mechanical means (hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge. |
| 2 | All Kind Of Soil @60% |
| 3 | Ordinary Rock@ 20% |
| 4 | Hard Rock (Blasting prohibited ) @20% |
| 5 | Earth work in excavation by mechanical means (hydraulic excavator) in trenches forfoundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts,wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sidesand ramming of bottoms lift upto 1.5 m, including getting out excavated earth anddisposal of surplus excavated earth as directed, within a lead of 50 metres. All kinds of soil |
| 6 | All Kind Of Soil @60% |
| 7 | Ordinary Rock@ 20% |
| 8 | Hard Rock (Blasting prohibited ) @20% |
| 9 | Extra for every additional lift of 1.5 m or part thereof in excavation/banking excavated or stacked material :All kinds of soil : |
| 10 | All Kind Of Soil @60% |
| 11 | Ordinary or hard rock @ 40% |
| 12 | Earth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 min width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides andramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth asdirected for lead up to 25 meter fromcutting edgein All kinds of soil. |
| 13 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) |
| 14 | Providing and laying in position cement concrete of specified grade including curing butexcluding the cost of centring and shuttering. All work upto plinth level with:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) with 20 % plums. |
| 15 | Providing and laying cement concrete in Protection walls, return walls, walls (any thickness)including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses,string or lacing courses, parapets, coping, bed blocks, anchors blocks, plain window sills,fillets etc upto floor V level, including curing but excluding the cost of centring, shutteringand finishing with1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) with 20% Boulders including necessary weep holes. |
| 16 | Providing and laying damp-proof Course 50 mm thick with cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) and curing complete. |
| 17 | Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size). |
| 18 | Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts upto floor five level including curing but excluding cost of centering shuttering, finishing and reinforcement with1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size). |
| 19 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size). |
| 20 | Providing and laying in position machine batched and machine mixed design mix M-25grade cement concrete for reinforced cement concrete work, using cement content as perapproved design mix, including pumping of concrete to site of laying but excluding thecost of centering, shuttering, finishing and reinforcement, including admixtures inrecommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in charge. Note: - Cement in this item is @ 330 kg/ cum. Excess or less cement used as per design mix iscontent considered payable or recoverable separately. All works upto plinth level |
| 21 | Providing and laying in position machine batched and machine mixed design mix M-25grade cement concrete for reinforced cement concrete work, using cement content as perapproved design mix, including pumping of concrete to site of laying but excluding thecost of centering, shuttering, finishing and reinforcement, including admixtures inrecommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in charge. Note: - Cement in this item is @ 330 kg/ cum. Excess or less cement used as per design mix iscontent considered payable or recoverable separately. All works above plinth level upto floor V level |
| 22 | Add or deduct for using more or less cement in the items of design mix over and above thespecified cement content therein. |
| 23 | Reinforcement for RCC works including straightening, cutting, bending, placing in position and binding all complete all work up to plinth level and above plinth level , Thermo-Mechanically Treated bars of grade Fe-500D or more., |
| 24 | Centering and shuttering including strutting, propping, etc and removal of form work for foundations , footings ,bases of columns, etc. |
| 25 | Centering and shuttering including strutting, propping, etc and removal of form work for Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. |
| 26 | Centering and shuttering including strutting, propping, etc and removal of form work for columns ,pillars ,piers etc. |
| 27 | Centering and shuttering including strutting, propping, etc and removal of form for suspended floors,roofs,landings,balconies and access platforms, stairs and spiral stairs cases. |
| 28 | Centering and shuttering including strutting, propping, etc and removal of form for lintels, beams , girders , bressumers and cantilevers all complete. |
| 29 | Centering and shuttering including strutting, propping, etc and removal of form for Stairs (excluding landings) except spiral staircases. |
| 30 | Centering and shuttering including strutting, propping, etc and removal of form for edges of slabs.(under 20 cm) |
| 31 | Brick work with common burnt clay (non-modular) bricks of class designation 7.5 infoundation and plinth including curing in : in Cement mortar 1:4 ( 1 cement : 4 coarse sand). |
| 32 | Brick work with common burnt clay (Non-Modular) bricks of class designation 7.5 in foundation and plinth including curing complete in Cement mortar 1:6 ( 1 cement : 6 coarse sand). |
| 33 | Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level. |
| 34 | Half brick masonry with common burnt clay (non-modular) bricks of class designation 7.5 in foundations and plinth including curing in : Cement mortar 1:3 ( 1 cement: 3 coarse sand). |
| 35 | Extra for half Brick masonry in superstructure above plinth level upto floor V level. |
| 36 | 12mm Cement plaster of mix: 1 : 6 ( 1 cement : 6 fine sand), |
| 37 | 15mm Cement plaster on the rough side of single or half brick wall of mix: 1:6 ( 1 cement : 6 fine sand ) |
| 38 | 6mm cement plaster to ceiling of mix 1 : 3 (1 cement: 3 fine sand). |
| 39 | 15mm Cement plaster finished with a floating coat of neat cement of mix1 : 3 ( 1 cement : 3 fine sand) (septic tank/sump tank). |
| 40 | Add for plaster drip course/grooves in plastered surface or moulding to R.C.C. projections |
| 41 | Making of Groove 12mmx10mm between brick and RCC |
| 42 | Cement concrete flooring 1:2:4 (1cement: 2 coarse sand: 4 graded stoneaggregate) includingcuring complete, but excluding the cost of nosing of steps etc.complete, 40mm thick with 20 mm nominal size stone aggregate. |
| 43 | Flooring with marble stone of specified thickness as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thickbase of cement mortar 1:4 (1 cement:4 coarse sand) laid and jointed with grey cement slurry including rubbing, polishing and curing complete with Makrana White Second quality 18mm |
| 44 | Providing and laying rectified Glazed Ceramic floor tiles of size300x300 mm or more (thickness to be specified by the manufacturer), of1st quality conforming to IS : 15622, of approved make, laid on 20 mmthick cement mortar 1:4 (1Cement : 4 Coarse sand), including groutingthe joints with white cement and matching pigments etc., complete.In all colours, shades, except White, Ivory, Fume Red Brown. |
| 45 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shadesexcept burgundy, bottle green, black ofsize 300x450mmas approved by Engineer- in-Charge, inskirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement :3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointingin white cement mixed with pigment of matching shade complete. |
| 46 | Providing and laying Mat finishedGranite stone flooring in required design and patterns, in linear as well as curvilinear portionsincluding steps risers, treads landing etc. of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. 11.68.1 Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. |
| 47 | Providing edge moulding to 18 mm/16 mm thick marble stone counters, Vanities etc.including machine polishing to edge to give high gloss finish etc. complete as per designapproved by Engineer-in-Charge. Granite Work |
| 48 | Providing and fixing gang saw cut, mirror polished, premoulded and prepolished, machinecut for kitchen platforms, vanity counters, window sills, facias and similar locations, ofrequired size, approved shade, colour and texture laid over 20 mm thick base cementmortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed withmatching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing toedges to give high gloss finish etc. complete at all levels.Granite of any colour or shade (Area of slab over 0.5 sqm) 16mm thick |
| 49 | Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixed with dash fastener of required dia. and size including necessary filling up of gaps at junctions i.e, at top, bottom and sides with required EPDM rubber / neoprene gasket felt etc. Aluminum sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminum snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge (glazing andpanellingto be paid for separately.) For fixed portion Powder coated aluminum (minimum thickness of powder coated 50 microns) |
| 50 | Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixed with dash fastener of required dia. and size including necessary filling up of gaps at junctions i.e, at top, bottom and sides with required EPDM rubber / neoprene gasket felt etc. Aluminum sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminum snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge (glazing, panelling and dash fasteners to be paid for separately.) For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required. ( Powder coated aluminum (minimum thickness of powder coated 50 microns) |
| 51 | Providing and fixing 12mm thick prelaminated particle board flat pressed three layer or graded wood particle board (conforming to IS: 12823 Grade-I type-II) in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-incharge Pre-laminated particle board with decorative lamination on both sides. |
| 52 | Providing and fixing glazing in aluminum door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc.complete as per the architectural drawings and the directions of engineer-in-charge.With float glass panes of 5.0 mm thickness (weight not less than 12.50 kg / sqm). |
| 53 | Providing and fixing fly proof wire gauze to windows, clerestory windows and doors with M.S Flat 15x3 mm and nuts and bolts complete Stainless steel (grade 304) wire gauze of 0.5mm dia wire and 1.4 mm aperture on both sides. |
| 54 | Providing and fixing Anodized aluminum grill (Anodized transparent or dyed to required shade according to IS: 1868 minimum anodic coating of Grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing windows frame with C.P. brass/stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved Anodized aluminum standard section around the opening, all complete as per requirement and direction of Engineer-in-charge. (only weight of grill to be measured for payment) |
| 55 | Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes channels, plates etc. including welding ,grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete ,including fixing the railing with necessary accessories and stainless steel dash fasteners, stainless steel bolts etc. of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 56 | Providing and fixing ISI marked oxidized M.S. sliding door bolts with nuts andscrews etc. complete : |
| 57 | 300 x 16 mm |
| 58 | Providing and fixing aluminum tower bolts ISI marked anodized (anodiccoating not less than grade AC 10 as per IS : 1868) transparent or dyed torequired colour or shade with necessary screws etc. complete : |
| 59 | 250x10 mm |
| 60 | 100x10 mm |
| 61 | Providing and fixing Aluminium hanging floordoor stopperISI marked anodized (anodic coating not less than grade AC 10 as per IS 1868 ) tranparent or dyed to required colour or shade with nuts and screwsetc. complete twin rubber stopper. |
| 62 | Providing and fixing aluminum handles ISI marked anodized (anodic coatingnot less than grade AC 10 as per IS: 1868) transparent or dyed to requiredcolour and shade with necessary screws etc. complete. |
| 63 | 125mm |
| 64 | 100mm |
| 65 | Providing and fixing bright finished brass hard drawn hooks and eyes 150 mm |
| 66 | Providing and fixing 1 mm thick M.S. steel door with frame of 40x40x6mm angle iron and 3mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer Using M.S. angles 40x40x6mm for diagonal braces. |
| 67 | Finishing with Deluxe multi surface paint system for interiors andexteriors using primer as per manufacturers’ specifications:Painting steel work with deluxe multi surface paint ofrequired shade to give an even shade. Two or more coats applied @0.90litre/10sqm over an under coat of primer applied @ 0.80litre/10sqm ofapproved brand and manufacture |
| 68 | Providing and applying white cement based putty of average thickness 2 mm of approved brand and manufacture over the plastered wall surface to prepare the surface even and smooth complete inclulding cost of material and carriage complete. |
| 69 | Distemper with oil bound washable distemper of approved brand and manufacture to give an even shade new work (two or more coats ) over and including priming coat with cement primer including all carriages and cost of materials involved. |
| 70 | Finishing walls with acrylic smooth exterior paint of required shade onNew work (Two or more coats applied @ 1.67 liter/10sqm over andincluding priming coat of exterior primer applied @ 2.20kg/10sqm) |
| 71 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot and cold water supply, including allCPVC plain and brass threaded fittings. This includes jointing of pipesand fittings with one step CPVC solvent cement and testing of jointscomplete as per direction of Engineer-in-charge. |
| 72 | Internal work-exposed on wall, including fixing the pipewith clamps at 1.00 meter spacing |
| 73 | 15mm nominal outer dia pipes. |
| 74 | 20mm nominal outer dia pipes. |
| 75 | 25mm nominal outer dia pipes. |
| 76 | Internal work Concealed fixing the pipe with clamps at1.00 meter spacing including cutting chases and making good thewall etc. |
| 77 | 15mm nominal outer dia pipes |
| 78 | 20mm nominal outer dia pipes. |
| 79 | External work including trenching, refilling etc. |
| 80 | 20mm nominal outer dia pipes |
| 81 | 25mm nominal outer dia pipes |
| 82 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps,including cutting and making good the walls etc.: medium |
| 83 | Internal work-exposed on wall, including fixing the pipewith clamps at 1.00 meter spacing |
| 84 | 15mm nominal outer dia pipes. |
| 85 | 20mm nominal outer dia pipes. |
| 86 | 25mm nominal outer dia pipes. |
| 87 | External work including trenching, refilling etc. medium |
| 88 | 20mm nominal outer dia pipes |
| 89 | 25mm nominal outer dia pipes |
| 90 | Providing and fixing on wall face un-plasticized Rigid PVC rainwater pipes conforming to IS: 13592 Type A including jointingwith seal ring conforming to IS: 5382 leaving 10 mm gap forthermal expansion. (i) Single socketed pipes 110 mm diametre. |
| 91 | Providing & fixing on wall face unplasticised- PVC mouldedfittings/ accessories for unplasticised rigid PVC rain water pipesconforming to IS: 13592 Type A, including jointing with seal ringconforming to IS 5382, leaving 10 mm gap for thermal expension(Make Supreme) Coupler 110mm. |
| 92 | Providing & fixing on wall face unplasticised- PVC mouldedfittings/ accessories for unplasticised rigid PVC rain waterpipes conforming to IS: 13592 Type A, including jointing withseal ring conforming to IS 5382, leaving 10 mm gap forthermal expension (Make Supreme) Single tee with door 110x110x110 mm. |
| 93 | Providing & fixing on wall face unplasticised- PVC mouldedfittings/ accessories for unplasticised rigid PVC rain water pipesconforming to IS: 13592 Type A, including jointing with seal ringconforming to IS 5382, leaving 10 mm gap for thermal expension(Make Supreme)Bend 87.5° 110 mm. |
| 94 | Providing & fixing PVC pipes 6 kg/ cm2 pressure excluding PVC fittings, jointing with adhesive/ seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion of approved make Supreme/ Finolex/ Astral or equivalent. |
| 95 | 110mm |
| 96 | 80mm |
| 97 | Providing and laying PVC accessories and fitting of approved make Supreme/ Finolex/ Astral or equivalent. |
| 98 | 110mm dia Door Tee |
| 99 | 110mm dia Plain Bend |
| 100 | 110mm Door Bend |
| 101 | 110mm dia Plain Tee |
| 102 | 80mm dia Door Bend |
| 103 | 80mm dia Door Tee |
| 104 | 80mm dia Plain Bend |
| 105 | 80mm dia Floor Trap. |
| 106 | 80mm dia Plain Tee |
| 107 | Providing and fixing 15 mm nominal bore C.P. brass long body bib cockof approved quality conforming to IS standards and weighing not lessthan 690 gms |
| 108 | Providing and fixing 15 mm nominal bore C.P. brass bib cock ofapproved quality conforming to IS : 8931 |
| 109 | Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:- (a) White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer. |
| 110 | Providing and fixing white vitreous china pedestal for wash basincompletely recessed at the back for the reception of pipes and fittings. |
| 111 | Providing and fixing 15 mm nominal bore C.P. brass angle valve forbasin mixer and geyser points of approved make conforming to IS : 8931 |
| 112 | Providing and fixing PTMT soap dish holder having length of 138mm,breadth 102mm, height of 75 mm with concealed fitting arrangements,weighing not less than 106 gms. |
| 113 | Providing and fixing un-plasticized P.V.C. connection pipe with PTMTnuts, collars and bush of approved quality and colour 15 mm nominal bore with 45 cm length. |
| 114 | Providing and fixing C.P. Brass extension nipple (size 15mmx50mm)of approved make and quality as per direction of Engineer-in-charge. |
| 115 | Providing and fixing C.P Cup. |
| 116 | Providing and fixing PTMT grating of approved quality and colour.Circular type.100 mm nominal dia. |
| 117 | Providing and fixing mirror of superior glass (of approved quality) and ofrequired shape and size with plastic moulded frame of approved makeand shade with 6 mm thick hard board backing. |
| 118 | Rectangular shape 453x357 mm |
| 119 | Providing and placing on terrace (at all floor levels) polyethylene waterstorage tank ISI : 12701 marked, with cover and suitable lockingarrangement and making necessary holes for inlet, outlet and overflowpipes but without fittings and the base support for tank. |
| 120 | Providing and fixing Stainless Steel A ISI304 (18/8) kitchen sink as perI.S. 13983 with C.I. brackets and stainless steel plug 40 mm, includingpainting of fittings and brackets, cutting and making good the wallswherever required : |
| 121 | Kitchen sink with drain board510x1040mm bowl depth 250mm |
| 122 | Kitchen sink without drain board. 610x510mm bowl depth 200mm |
| 123 | Extra for providing opening of required size and shape for wash basin/ kitchen sink in kitchen platform, vanity counters and similar location in marble/granite / stone work including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. |
| 124 | Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour:Waste coupling 38mm of 83 mm length and 77 mm breadthweighing not less than 60gms. |
| 125 | Providing and fixing PTMT Waste Pipefor wash basin and sink, of approved quality and colour: Flexible pipe 32 mm dia |
| 126 | Providing and fixing Ball Valve (brass) of approved quality,high or low pressure with plastic floats complete.25 mm |
| 127 | Providing and fixing Ball Valve (brass) of approved quality,high or low pressure with plastic floats complete. 20 mm |
| 128 | Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour |
| 129 | 20 mm nominal bore, weighing not less than 40gms |
| 130 | 25 mm nominal bore, weighing not less than 62gms |
| 131 | Providing and installation of electric water motor of Crumtum or equivalentmake having 01 H.P including all fitting complete. |
| 132 | Providing and laying integral cement based water proofing treatmentincluding preparation of surfaces as required for treatment of roofs,balconies, terraces etc consisting of following operations.a) Applying a slurry coat of neat cement using 2.75kg/sqm of cementadmixed with water proofing compound conforming to IS 2645 andapproved by Engineer-in-charge over the RCC Slab including adjoiningwalls upto 300mm height including cleaning the surface beforetreatment.b) Laying brick bats with mortar using broken bricks/ Brick Bats 25mmto 115mm size with 50% of Cement mortar 1:5 (1 Cement : 5 coarsesand) admixed with water proofing compound conforming to IS 2645and approved by Engineer-in-charge over 20mm thick layer of cementmortar of mix 1:5 (1 Cement : 5 coarse sand) admixed with waterproofing compound conforming to IS 2645 and approved by Engineerin-charge to required slope and treating similarly the adjoining wallsupto 300mm height including rounding of Junctions of walls and slabs) c) After two days of proper curing applying a second coat of cement slurry using 2.75kg/sqm of cement admixed with water proofingcompound conforming to IS 2645 and approved by Engineer-in-charge.d) finishing the surface with 20mm thick joint less cement mortar of mix1:4(1 cement: 4 coarse sand) admixed with water proofing compoundconforming to IS 2645 and approved by Engineer-in-charge includinglaying glass fibre cloth of approved quality in top layer of plaster andfinally finishing the surface with trowel with neat cement slurry and making pattern of 300x300mm/sq 3mm deep.e) The whole terrace so finished shall be flooded with water for aminimum period of two weeks for curing and for final test. All aboveoperations to be done in order and as directed and specified by Engineerin-charge. With average thickness of 120mm and minimum thickness atkhurra as 65 mm. |
| 133 | Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement: 3 fine sand) as per standard design. In 75x75mm deep chase. |
| 134 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron,finished with 12 mm cement plaster 1:3 (1 cement: 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. |
| 135 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth and curing complete incl cost of material and carriage complete. |
| 136 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m. |
| 137 | Chequerred terrazzo tiles 22mm thick with graded marble chips of size upto 6mm in floors, jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing, polishing and curing complete, on 20 mm thick bed of cement mortar 1:4 ( 1 cement : 4 coarse sand) .Light shade using white cement |
| 138 | Cement concrete flooring 1:2:4 (1cement: 2 coarse sand: 4 graded stoneaggregate) finished with a floating coat of neat cement including cementslurry and curing complete, but excluding the cost of nosing of steps etc. 40 mm thick with 20mm nominal size stone aggregate. complete(drain flooring). |
| 139 | Providing and fixing square- mouth S.W. gully trap class SP-1 completewith C.I. grating brick masonry chamber with water tight C.I. cover withframe of 300x300 mm size (inside) the weight of cover to be not lessthan 4.50 kg and frame to be not less than 2.70 kg as per standard design.180 x 150 mm size P type With common burnt clay F.P.S. (non modular) bricks of classdesignation 7.5 |
| 140 | Constructing brick masonry chamber for underground C.I. inspection chamber and bends with 75 class designation bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) , inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design :Inside dimensions 455x610 mm and 45 cm deep for singlepipe line. |
| 141 | Wiring for light point/ fan point/ exhaust fan point/ call bellpoint with 1.5 sq.mm FRLS PVC insulated copper conductorsingle core cable in surface / recessed medium class PVCconduit, with modular switch, modular plate, suitable GI boxand earthing the point with 1.5 sq.mm FRLS PVC insulatedcopper conductor single core cable etc. as required.Group C |
| 142 | Wiring for Light /Power Plug with 2 x 4 sq.mm FRLS PVC Insulated Copper Conductor single core cable in surface/Recessed medium class PVC Conduit along with 1 No. 4 sq.mm FRLS PVC Insulated copper conductor single core cable for loop earthing as required. |
| 143 | Wiring for Circuit/Submain Wiring along with earth Wire with the following Sizes of FRLSPVC insulated copper conductor,single core Cable in surface/Recessed medium class PVC conduit as required.2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 144 | supplying and fixing modular blanking plate on the existing modular plate and switch box excluding modular plate as required. |
| 145 | Supplying and Fixing suitable size G.I box with modular plate and cover in front on surface or in recess,including providing and fixing 6 pin 15/16amps modular socket outlet and 15/16 amps modular switch,connection,painting etc. as required. |
| 146 | Supplying and fixing suitable size GI box with modular plate andcover in front on surface or in recess, including providing andfixing 3 pin 5/6 A modular socket |
| 147 | Supplying and fixing 5 amps. to 32 amps.rating 240 volts \"C\" series, miniature circuit breaker of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single Pole |
| 148 | Triple pole |
| 149 | Supplying and fixing of following ways surface/ recessmounting, vertical type, 415 V, TPN MCB distribution board ofsheet steel, dust protected, duly powder painted, inclusive of200 A tinned copper bus bar, common neutral link, earth bar,din bar for mounting MCBs12 way (4 + 36), Double door |
| 150 | Providing and fixing following rating and breaking capacity andpole MCCB with thermomagnetic release and terminalspreaders in existing cubicle panel board including drilling holesin cubicle panel, making connections, etc. as required.100 A, 16 KA,TPMCCB |
| 151 | Supply and Fixing Single Pole Blanking Plate in the Existing MCB DB complete as Required. |
| 152 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thickincluding accessories, and providing masonry enclosure withcover plate having locking arrangement and watering pipe of2.7 metre long etc. with charcoal/ coke and salt as required. |
| 153 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metrebelow ground as strip earth electrode, including connection/terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nutbolt & spring washer spaced at 50mm) |
| 154 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I.pipe from earth electrode including connection with G.I. nut,bolt, spring, washer excavation and re-filling etc. as required. |
| 155 | Supply installation testing and commissioning of IP65 led Street Light 90 W +/- 5 Wcomplete with M.S/G.I Pipe(Duly Bracket embedded along with Parapet/Wall including complete connections as required .The P.F.>0.95 ,THD<10% ,CCT 5700K, CRI 80. The LED with Useful life of 50000 Hrs at L70. The Input voltage range shall be 150V to 265V. The Fixture should have In-built Surge Protection of 2.5kV Certification:- LM79 & LM80 test report should be from govt approved Inhouse NABL lab/ government of India authorised lab . |
| 156 | Supply installation testing and commissioning of IP:20 AluminiumBatten 40 W +- 1 W LED Surface Mounted 4 ft. with system lumen efficacy of 100 lm/W and P.F >0.9 THD <20% CCT 6500K,CRI 80 .The LED should have life of 50000 Burning Hours at L70.The inputvoltage shall be 150 V to 270 V.The fixture should have inbuit surge protection of 2KV.Certification-LM 79 and LM 80.The test report should be from Govt. Approved Lab/inhouse NABL Lab. |
| 157 | Supply,Installation,Testing and Commissioning 486 Cu.m/Hr. AC220-240Volts, 50 Hzexhaust fan made out ofMetal Body with inbuilt thermo cutoff Protection and Noise Level not exceeding 37 dBof Following Sizes including connection etc. complete as required .300 mm |
| 158 | Supply installation testing and commissioning of IP:20 AluminiumBatten 10W-12 W +- 1 W LED Surface Mounted 2 ft. with system lumen efficacy of 100 lm/W and P.F >0.9 THD <20% CCT 6500K,CRI 80 .The LED should have life of 50000 Burning Hours at L70.The inputvoltage shall be 150 V to 270 V.The fixture should have inbuit surge protection of 2KV.Certification-LM 79 and LM 80.The test report should be from Govt. Approved Lab/inhouse NABL Lab. |
| 159 | Supply installation testing and commissioning ofCeiling Fan 3 Star Rated with Voltage Range 90 V to 300 V,Min. Air Delivery 212 CMM,Service Value 5.3 Cu.m/min/watt,Aluminium Blades ,including wiring the down rods of standard length(Upto 45 cm)with 1.5 sq.mm FR PVC insulated,copper conductor,single core cable including providing and fixing phenolic laminated sheet cover on the Fan Box etc as Required. |
| 160 | Providing and fixing of lightning conductor finial, made of 25mm dia 300 mm long, G.I. tube, having single prong at top, with85 mm dia 6 mm thick G.I. base plate including holes etc.complete as required. |
| 161 | Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet orsurface of wall for lightning conductor complete asrequired.(For horizontal run) |
| 162 | Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet orsurface of wall for lightning conductor complete asrequired.(For vertical run) |
| 163 | Supplying and Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in groundin Existing DWC Pipe including excavation, sand cushioning, protective covering and refilling the trench etc as required.4.0 C X 16 Sq.mm A2XFY |
| 164 | 3.5 C X 35 Sq.mm A2XFY |
| 165 | Supply and Making end Termination with Brass Compression Gland and Aluminium Lugs for the Following Sizes of PVC insulated and PVC Sheathed/XLPE Aluminium Conductor Cable of 1.1 KV Grade as Required .4 X 16 sq. mm (28mm) |
| 166 | 3.5 C X 35 Sq.mm(32 mm) |
| 167 | Supplying and laying of following size DWC HDPE pipe ISI markedalong with all accessories like socket, bend, couplers etc.conforming to IS 14930, Part II complete with fitting and cutting,jointing etc.direct in ground (75 cm below ground level) includingexcavation and refilling the trench but excluding sand cushioningand protective covering etc., complete as required.63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 168 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Telephone socket outlet |
| 169 | TV antenna socket outlet |
| 170 | Computer Socket RJ45 Modular type |
| 171 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.1 or 2 Module (75mmX75mm) |
| 172 | Supplying and Fixing of Following sizes of PVC Conduit along with Accessories in surface/Recess including painting in case of surface conduit,cutting the wall and making good the same in case of recessed conduit as required.20 mm PVC Conduit |
| 173 | Supplying and drawing following pair 0.5 mm dia FRLS PVCinsulated annealed copper conductor, unarmored telephonecable in the existing surface/ recessed steel/ PVC conduit asrequired.2 Pair |
| 174 | Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mmsolid copper conductor PE insulated, shielded with fine tinnedcopper braid and protected with PVC sheath in the existingsurface/ recessed steel/ PVC conduit as required. |
| 175 | Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in theexisting surface/ recessed Steel/ PVC conduit as required.1 run of cable |
| 176 | Supply&Erectionoflockable12 Urackwith5Astripand twofanfordistribution,mountingofpatchpanels,hubs, switches etc,, complete as per specification and as desired by EIC. |
| 177 | Supply, installation, testing and commissioning of Junction Boxes/DB-10 Pairs with Original Krone module and Back Mount Frame and have Lock -n- key, complete in all respect as per specification and desired by EIC |
| 178 | Supplying, installation, testing & commissioning of maincontrol and indicating panel made out of 16 SWG MS sheetto accommodate the following items duly powder coated inapproved colour with louvers for ventilation, lockingarrangement, audio and visual indication for fire alarm andpublic address system, monitoring system includingconnections, interconnections etc complete as required.6 zone panel for fire alarm system100 watt amplifier racks suitable for operation on 230VAC/24V DC supply conforming to IEC-268-3 complete with all Talk back master station with LED PTT (press to talk) pushbutton for operation on 230V AC/24 V DC supply conformingto IEC-268 for simplex mode of operation/communicationsuitable for 20 Nos.talk back unit -1 set.Annoucement control desk suitable for selection of differentzones selectively and ON ALL CALL switch with visualindication etc., complete as required- 1 set.Amplifier change over switch for inter changing amplifier- 1 No.Monitor panel for loudspeaker complete output selectorON/OFF switch, fuse visual indications etc. complete asrequired- 1 No.Gooseneck microphone with stand and ON/OFF switch -1 No.Mains ON/OFF switch, fuse indication lamps, DC and ACvoltmeters & ammeters terminal blocks etc. complete asrequired -1 set.Battery charger trickle cum boost to take complete load offire alarm & PA system complete with all accessoriesincluding providing & fixing of 2 nos. 12 volt,30 AH eachsealed maintenance free batteries -1 set. |
| 179 | Supplying, installation, testing & commissioning ofSmokedetector operating at 54ºC/57ºC with rate of rise cum fixedtemperature (dual thermistor) type with mounting basecomplete with all connection etc. as required. |
| 180 | Supplying, installation, testing & commissioning fire alarmsounder with facility to make announcement, mounted in M.S.box (16 SWG) with hinged cover plate & suitable for operationwith amplifier i/c line matching transformer etc. complete asrequired. |
| 181 | Supplying, installation, testing & commissioning of manual callboxes of MS construction in surface/recess with stainless steelchain & hammer assembly complete with glass and push buttonetc. as required. |
| 182 | Supplying and drawing following sizes of FRLS PVC insulatedcopper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required2 x 1.5 sq. mm |
| 183 | Providing, laying, testing & commissioning of \"C\" class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges,tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :25 mm dia |
| 184 | 80 mm dia |
| 185 | 100 mm dia |
| 186 | Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required :Single headed Gunmetal |
| 187 | Supplying and fixing orifice plate made out of 6 mm thick Stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required. |
| 188 | Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :Gun Metal |
| 189 | Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red,conforming to IS 884 complete with the following as required.20 mm nominal internal dia water hose thermoplastic(Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle.Drum and brackets for fixing the equipmets on wall.Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.30m |
| 190 | Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required :2way - 100 mm dia M.S. Pipe |
| 191 | Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shadeas required. |
| 192 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 193 | Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required :Gun metal |
| 194 | Providing and fixing Weather proof hose cabinets for yard hydrant fabricated from 16 g MS sheet with full glass door and locking arrangement, suitable to accommodate one hydrant valve, 2 nos.15m long hose, 1 No branch pipe and one fireman\"s axe. The cabinet shall be painted with one coat of primer and finished stove enamelled \"Fire Red\", \"Fire Hose\" written on front including suitably mounted on a raised masonry platform as required. (Approx 0.75mx0.6 mx 0.25 m). |
| 195 | Providing and fixing standard fireman\"s axe with heavy insulated rubber handle conforming to IS: 926 complete. |
| 196 | Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump)(a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520b) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure,horiziontal foot mounted type with Class-\"F\" insulation,conforming to IS-325.(c) M.S.fabricated common base plate, coupling, couplingguard, foundation bolts etc.as required.(d) Suitable cement concrete foundation duly plasteredand with anti vibration pads.450 lpm at 35 m Head |
| 197 | Supplying,Installation,Testing and Commissioning of Cubical Type OutdoorLT Panel Board Suitable for 415 V 3 Phase 4 Wire 50 HZ AC Supply System including Incomers,Out Goings,Bus Bars etc. as required as per the Following Description.(IP:55) (Terrace Panel) .The successful tenderer shall take prior approval for the panel builder/fabricator alongwith G.A. drawing, wiring diagrams, single line diagrambefore start of fabrication of LT panel.Circuit breaker shall be capable of carrying the full load current defined for 50 degree Celsius without any derating.The Panel Builder Shall beCPRI /ERDA/ANY NABL ACCREDITED LAB approved.Refer SLD |
| 198 | INCOMERMCCB 63 A F.P 25 Kawith Adj. Thermal & Adj. magnetic release with Extendable ROH Icu=Ics=100% |
| 199 | Digital Metering Devices,comprising Voltmeter,Ammeter,Selector Switch,Indicating Lamps,C.T Set,Bus Bar(80 Amps ) and MCB Strip of suitable size as Required. |
| 200 | OUTGOINGSMPCB 19-25 A With STD. Magnetic Release |
| 201 | Power Contactor 40 A415 Volts, AC-3Duty |
| 202 | Start/Stop Push ButtonSize of wiring for CTS:- 2.5 sqmmSize of wiring for voltage sensing Metering :-4.0 Sq.mmSize of wiring of all push buttons, indicating lamps:-1.5 Sq.mmTypes of wires:-PVC insulated 1100Vgrade ,Multistrand copper conductor Flexible FR-LSHHinged Door Earthing:-Device mounted hinged doors connected to cubicles body by means of 2.5 sqmm.green copper flexible wire .The Complete Panel Shall be Made out of 2.0mm CRCA sheet including Frame/Partitions/Doors etc.Gland Plates to be 3.0 mm Thick. |
| 203 | Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :100 mm dia |
| 204 | 80 mm dia |
| 205 | Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :100mm dia |
| 206 | Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm diaholes with stainless steel flange.100mm dia |
| 207 | Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required. |
| 208 | Providing, installation, testing and commissioning of Pressure Guages |
| 209 | Supplying,Installation,Testing and Commissioningof CO2 Type Fire Extinguisher 4.5 Kg. Capacity ISI Mark(IS:15683)suitable for\"B\" and \"C\" class fires - inflammable liquids, gaseous fires like L.P.G. and acetylene, and electrical fires |
| 210 | Supplying,Installation,Testing and CommissioningofMAP 90 ABC Type Fire Extinguisher 4.0 Kg. Capacity ISI Mark(IS:15683)suitable for Class A/B/C Type Fires . |
| 211 | Carriage of material by mechanical transportation. |
| 212 | Sandaverage lead 50 Km By M.T. |
| 213 | Stone aggrigate40mm and aboveAverageLead 10.0 Km By M.T. |
| 214 | Stone agrigate below40mm. average Lead 10.0 KmBy mechenical means. |
| 215 | Bricks, average Lead 105 KmBy mechenical means. |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail