Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 26-03-2025 | second Call | Date | 30-03-2025 |
| Sl. No. | Item Description |
| 1 | SUB ESTIMATE NO.1 Plastic Waste Storage Cage |
| 2 | Item No.1: Providing and fixing crimped with G.I. mesh and size 20mmx20mm 10 guage to iron angle frame including welding crimp mesh to angle frame and steel flat, fixing the frame in its original position and oil painting etc. complete (excluding cost of structural steel. |
| 3 | Item No.2:Providing and fixing corrugated galvanised iron sheets of 0.63 mm thick (24B.W.G.) for roofing without wind tiles including fastening with galvanised iron screws and bolts, lead and bitumen washers as per drawing etc. complete. (Weight of 5.5 kg/sq.m.). |
| 4 | Item No.3: Providing structural steel work in trusses, other similar trussed purlins and members with all bracing, gusset plates etc. as per detailed designs and drawings or as directed including cutting, fabricating, hoisting, erecting fixing in position, Making riveted /bolted/welded connection and one coat of anticorrosive paint and over it 2 coats of oil painting approved quality and shade etc. complete. |
| 5 | SUB ESTIMATE NO.2.Leach Pit with Inlet Chember-5KLD |
| 6 | Item No 5: Excavation for foundation/pipe trenches in earth, soils of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A-1/259) |
| 7 | Item No 6:Excavation for foundation/pipe trenches in hard murum and boulders, W.B.M. road including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A-3/259) |
| 8 | Item No 7:Excavation for foundation/pipe trenches in soft rock and old cement and lime masonry foundation asphalt road including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking as directed by Engineer-in- charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A-4/259) |
| 9 | Item No.8 : Providing and laying in situ Cement Concrete M-15 of trap/ granite/quartzite/gneiss metal for foundation and bedding including bailing out water, form work, compaction, curing, etc. complete. (Cement 5.90 bags/cum) Spec. No. - Bd E/1 Page No. 287 and B-7, Page No. 38 (PCC-M- 150) |
| 10 | Item No.8 : Providing second class Burnt Brick masonry with conventional/ 1.S. type bricks in cement mortar 1:4 including scaffolding, racking out joints and watering etc. in pillar of rectangular shapes as shown in the drawings or as directed complete |
| 11 | Item No.9:Providing internal cement plaster 12 mm thick in single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete. |
| 12 | Item No.9:Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap/granite/quartzite/gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete, (Excluding reinforcement and structural steel). With fully automatic microprocessor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan Mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 13 | Item No.9:Providing and fixing in position steel bar reinforcement of various diameters for RCC piles, caps, footings, foundations, slabs, beams, columns, canopies, staircases, newels, chajjas, lintels, pardies, copings, fins, arches, etc. as per detailed designs, drawings and schedules; including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required, etc. complete (including cost of binding wire). (Bd-F-17/306)(B Tor Steel) |
| 14 | Item No.9:Providing and fixing in position steel fibre reinforced concrete (S.F.R.C.) frame and covers of approved make including loading, unloading, transportation, all taxes, etc. complete as directed by Engineer in charge (20 tonnes capacity). |
| 15 | Item No.9:Providing and supplying in standard lengths ISI mark rigid unplasticised PVC pipes suitable for potable water with solvent cement joints including cost of couplers, as per IS specification no. 4985/1988 excluding GST levied by GOI and GOM in all respect, including transportation, freight charges, inspection charges, loading, unloading, conveyance to the departmental stores and stacking the same in closed shed duly protected from sun rays and rains including cost of jointing material i.e. solvent cement, etc. complete (selffit type to be jointed with cement solvent).capacity). |
| 16 | SUB ESTIMATE NO.3. 50 KLD STP based on CAMUS Technology |
| 17 | Excavation for foundation / pipe trenches in earth, soils of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A-1/259) |
| 18 | 0.0 to 1.5 m |
| 19 | 1.5 to 3.0 m |
| 20 | 3.0 to 4.5 m |
| 21 | 4.5 to 6.0 m |
| 22 | Excavation for foundation / pipe trenches in hard murum and boulders, W.B.M. road including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A-3/259) |
| 23 | 0.0 to 1.5 m |
| 24 | 1.5 to 3.0 m |
| 25 | 3.0 to 4.5 m |
| 26 | 4.5 to 6.0 m |
| 27 | Excavation for foundation / pipe trenches in soft rock and old cement and lime masonry foundation asphalt road including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A-4/259) |
| 28 | 0.0 to 1.5 m |
| 29 | 1.5 to 3.0 m |
| 30 | 3.0 to 4.5 m |
| 31 | 4.5 to 6.0 m |
| 32 | Excavation for foundation / pipe trenches in hard rock and concrete road by chiselling, wedging, line drilling by mechanical means or by all means other than blasting including trimming and levelling the bed, removing the excavated material upto a distance of 50 metres beyond the area and lifts as below, stacking as directed by Engineer-in-charge, normal dewatering, excluding backfilling, etc. complete by all means. (Bd-A-6/259) |
| 33 | 0.0 to 1.5 m |
| 34 | 1.5 to 3.0 m |
| 35 | 3.0 to 4.5 m |
| 36 | 4.5 to 6.0 m |
| 37 | Providing dry trap/ granite/ quartzite/ gneiss, rubble stone soling in 15 cm to 20 cm thick layers including hand packing and compacting, etc. complete. (Bd-A-12/264) |
| 38 | Providing and laying in situ Cement Concrete M-15 of trap/granite / quartzite / gneiss metal for foundation and bedding including bailing out water, form work, compaction, curing, etc. complete. (Cement 5.90 bags / cum) Spec. No. - Bd E /1 Page No. 287 and B-7, Page No. 38 |
| 39 | Providing and laying in situ Cement Concrete of trap/ granite/quartzite / gneiss metal for RCC work in foundation like raft, grillage, strip foundation and footing of RCC columns and steel stanchions including normal dewatering, form work, compaction, finishing and curing, etc. complete. (By weigh batching and mix design for M250 and M-300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement) (RCC M-300 ) |
| 40 | Providing and casting in situ C.C. of trap / granite/ quartzite/gneiss metal of approved quality for RCC works as per detailed drawings and designs or as directed by Engineer-in-charge including normal dewatering, centering, forrn work, compaction, finishing the formed surfaces with C.M. 1:3 of sufficient minimun thickness to give a smooth and even surface wherever necessary or roughening if special finish is to be provided and curing, etc. complete. (By weigh batching and mix design for M-250 and M-300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement (RCC M-300 ) |
| 41 | Providing and casting in situ C.C. of trap/granite/ quartzite/gneiss metal of approved quality for RCC works as per detailed drawings and designs or as directed by Engineer-in-charge including normal dewatering, centering, form work, compaction, finishing the formed surfaces with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface wherever necessary or roughening if special finish is to be provided and curing, etc. complete. (By weigh batching and mix design for M-250 and M-300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement)RCC M-300 |
| 42 | Providing and casting in situ C.C. of trap / granite/ quartzite/gneiss metal of approved quality for RCC works as per detailed drawings and designs or as directed by Engineer-in-charge including normal dewatering, centering, form work, compaction, finishing the formed surfaces with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface wherever necessary or roughening if special finish is to be provided and curing, etc. complete. (By weigh batching and mix design for M-250 and M-300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement)RCC M-300 |
| 43 | Providing and fixing in position steel bar reinforcement of various diameters for RCC piles, caps, footings, foundations, slabs, beams, columns, canopies, staircases, newels, chajjas, lintels, pardies, copings, fins, arches, etc. as per detailed designs, drawings and schedules; including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required, etc. complete (including cost of binding wire). (Bd-F-17/306) c) Corrosion Resistant Steel (Fe 500) |
| 44 | Providing and fixing mild steel grill work for windows/ ventilators of 20 Kg/Sqm. As per drawings including necessary welding and painting with one coat of anticorrosive paint and two coats of oil painting, etc. complete. (Bd-U-1/537) |
| 45 | Providing rough cast cement plaster externally in two coats to concrete, brick or stone masonry surfaces in all positions with base coat of 12 to 15 mm thick in C.M. 1:4 and rough cast treatment 12 mm thick in proportion 1:11 / 2:3 including scaffolding and fourteen days curing complete. |
| 46 | Providing and applying white-wash in two coats on old/ new plastered or masonry surfaces and asbestos cement sheets including scaffolding and preparing the surface by brushing and brooming down etc. complete. |
| 47 | Providing and applying colour-wash of approved colour and shade in one coat to new surface including scaffolding, brushing and brooming down (excluding base coats of white wash) etc. complete. |
| 48 | Dewatering the excavated trenches and pools of water in the building trenches / pipeline trenches, well works by using pumps and other devices including disposing off water to safe distance as directed by Engineer-in-charge (including cost of machinery, labour, fuel), etc. complete. |
| 49 | Refilling the trenches with available excavated stuff with soft material first over pipeline and then hard material in 15 cm layers with all leads and lifts including consolidation, surcharging, etc. complete. |
| 50 | Transportation as per STATEMENT VI Including loading, unloading and stackingEarth (4.8 Curn) lead 15 Km |
| 51 | Electromechnical ItemsScreen (Manual) of size 1.6 m length x 0.5 m width of SS 304 MOC and Manual hand rake for cleaning screen of SS handle 1 m in length and cleaning area of 6 nos 5 mm SS rod of total length 200 mm straight and 50 mm of 90 degree bend. |
| 52 | Submersibe Pump Providing, erecting and giving test of submersible pump set conforming to IS 8034 and motor conforming to IS 9283, with water proof winding. Pump shall be suitable for various delivery head and discharge with stainless steel shaft. Motor suitable for working on 415 V ± 10%, 3 Ph, 50 Hz A.C. Supply, with cable guard, thrust carbon/fiber bearing to withstand entire hydraulic thrust. The pump set shall be suitable for direct coupling, with suitable suction strainer. Pump should have suitable discharge out let as per manufacturer\"s design. Antithrust stream lined non return valve shall be provided with the pump. 3 m submersible copper conductor cable in single / double run and 2 pairs of suitable size erection clamp 10 mm thick shall be provided with each pump. 1.5 HP |
| 53 | Raw Sewage PumpSupplying Non-clog Submersible Pump suitable for sewage/ Liquid waste application with standard MOC and given duty points as below1 HP (Up to 9000 LPH) |
| 54 | NaOCI Chlorinator Pump Diaphragm Type / peristaltic type / Solenoid Max Flow Rate Upto 10LPH Power Source Electric Phase Single Material PP/PTFE (Teflon) Voltage 230 Volt Frequency 50Hz Mixing Tank of 100 Ltrs capacity- 1 No Dosing Pump-2 Nos |
| 55 | Control PanelDesigning, Supplying, Installing, commissioning & testing of PLC Panel.Including PLC with CPU & Power supply unit, power supplyb cables interfacing cards, interfacing cables, wireless modules with 25% extra quantity of all accessories. |
| 56 | Supplying and erecting Fully Automatic Star Delta starter to operate squirrel cage induction motor working on 380-440 Volt, 3 phase, 50 Hz with no volt coil, over load element, and ON-OFF push buttons, with necessary material and connected to supply, etc complete. Starter with original sheet steel encloser.> 7.5 HP & Up to 12.5 HP |
| 57 | Main power supply cable 3 core PVC insulated, PVC sheathed copper conductor flat submersible cable Supplying and erecting, Flat flexible submersible cable with, Copper Conductor, PVC insulated, and PVC sheathed.3 core 16 sq mm |
| 58 | Power cables Aluminium conductor 4 Core, XLPE/PVC insulated & armoured cable Supplying and erecting, XLPE/PVC insulated, armoured cable 1100 V grade with ISI mark Four core, solid/ stranded aluminium conductor with 6 mm thick 25 mm width M.S. spacer with G.I. Earth wire 6 sq mm, complete erected on wall / on pole with 25 X 3 mm M.S. clamps or in provided trench in an approved manner. 4 Core 6 sq mm |
| 59 | Control Panel Copper conductor PVC insulated, Unarmoured control cableSupplying and erecting Un-armoured control cable with ISI mark stranded / solid copper conductor 1.1 kV grade complete erected on wall / panel or in provided trench in an approved manner. 4 core 2.5 sq mm |
| 60 | Providing and supplying in standard lengths ISI mark Rigid unplasticised PVC pipes suitable for potablewater with solvent cement joints including cost of couplers, as per IS specification no. 4985/1988 excluding GST levied by GOI and GOM in all respect, including transportation, freight charges, inspection charges, loading, unloading, conveyance to the departmental stores and stacking the same in closed shed duly protected from sun rays and rains including cost of jointing material i.e. solvent cement, etc. complete (selffit type to be jointed with cement solvent). |
| 61 | 1) 10% of cost of pipes shall be considered for cost of PVC specials for estimate purpose only. 2) One coupler and required cement solvent shall be provided with each full length pipe cost of which is included in rates below. |
| 62 | Item No.37:Raw Sewage pump to CAMUS DistributionMain header 75 mm. 10 kg/sq.cm |
| 63 | PVC Specials- 10% |
| 64 | Item No.38:Distribution63 mm. 10 kg/Sq.cm |
| 65 | PVC Specials- 10% |
| 66 | Item No.39:CAMUS collection Main header75 mm. 10 kg/Sq.cm |
| 67 | PVC Specials- 10% |
| 68 | Item No.40:collection tributory63 mm.10 kg/Sq.cm |
| 69 | PVC Specials- 10% |
| 70 | Item No.41:CAMUS distribution63 mm. 10 Kg/Sq.cm |
| 71 | PVC Specials- 10% |
| 72 | Item No.42:Labour |
| 73 | Plumber |
| 74 | Helper |
| 75 | Providing double flange sluice valve confirming for IS- 14846 including worn gear arrangements as per test pressure, stainless steel spindle, caps, including inspection charges, transportation upto departmental store, unloading, stacking excluding GST levied by GOI & GOM in all respect etc.complete.Sluice valves - PN-1 (Without by pass) Raw Sewage pump 80 mm. |
| 76 | Providing and supplying ISI mark CI D/F reflux valves (non-return valves) of following dia including railway freight, inspection charges, unloading from railway wagon, loading into truck, transportation upto departmental stores, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. complete. Reflux valves as per 1.S.5312 Part I (1984) Without by pass arrangement-PN-1Raw Sewage pump 80 mm. |
| 77 | Bio media Items Providing, laying, spreading in layers stone aggregates of specific size as a Bio- media filter material as specified and directed by technology provider including all labour, material, loading, unloading, transportation, upto 15 Km. lead, placing the bio media in bio reactor including all taxes and duties such as royalty...etc. completeSupplying crushed metal 60 to 80 mm of trap/granite/quartzite/gneiss stone metal at the site including conveying & stacking. 15 Km Lead. Also Laying into Bio Mound Tank as directed by Vision Earthcare Pvt Ltd. |
| 78 | Supplying crushed metal 20mm of trap/granite/quartzite/gneiss stone metal at the site including conveying & stacking. 15 Km Lead. Also Laying into Bio Mound Tank as directed by Vision Earthcare Pvt Ltd. |
| 79 | Supplying 40 to 60mm of Hard Murrum at the site including cleaning and laying into Bio Mounds as directed by Vision Earthcare Pvt Ltd |
| 80 | Providing and fixing Jute Kanthan (Tarat) sceen to the scaffolding for external guniting as directed including removing the work is over etc.complete |
| 81 | Excavating the ground to required depth up to 30 CM, removing and conveying unwanted stuff to required distance as directed, filling fresh garden soil and manure in excavated area 3:1 proportion to a height 30CM mixing garden soil and manure slowly leveling watering on previous night, planting well rooted shrubs 0.5 m or as directed and mentaining till well established by watering wedding string replacing etc complete. |
| 82 | Supply, Installation and Testing of Tube Settler Packing |
| 83 | Providing supplying culture Catalyst & On site demostration as per the M/s Vision Earthcare Pvt Ltd all as specified including MOU with technology expert M/s Vision Earthcare Pvt Ltd CAMUS Patent No 414339 Technology Consultancy Charges (General Arranagement and Hydraulic Flow Diagram-Design and Drawings), CAMUS Cultures, CAMUS Catalyst, Maharashtra GO No. Serial No 2017/Sch No351/UDD-33 1 dated 27 Feb 2018 |
| 84 | SUB ESTIMATE NO. 250 KLD STP based on CAMUS Technology |
| 85 | Excavation for foundation / pipe trenches in earth, soils of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A-1/259) |
| 86 | 0.0 to 1.5 m |
| 87 | 1.5 to 3.0 m |
| 88 | 3.0 to 4.5 m |
| 89 | 4.5 to 6.0 m |
| 90 | Excavation for foundation / pipe trenches in hard murum and boulders, W.B.M. road including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A-3/259) |
| 91 | 0.0 to 1.5 m |
| 92 | 1.5 to 3.0 m |
| 93 | 3.0 to 4.5 m |
| 94 | 4.5 to 6.0 m |
| 95 | Excavation for foundation / pipe trenches in soft rock and old cement and lime masonry foundation asphalt road including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A-4/259) |
| 96 | 0.0 to 1.5 m |
| 97 | 1.5 to 3.0 m |
| 98 | 3.0 to 4.5 m |
| 99 | 4.5 to 6.0 m |
| 100 | Excavation for foundation / pipe trenches in hard rock and concrete road by chiselling, wedging, line drilling by mechanical means or by all means other than blasting including trimming and levelling the bed, removing the excavated material upto a distance of 50 metres beyond the area and lifts as below, stacking as directed by Engineer-in-charge, normal dewatering, excluding backfilling, etc. complete by all means. (Bd-A-6/259) |
| 101 | 0.0 to 1.5 m |
| 102 | 1.5 to 3.0 m |
| 103 | 3.0 to 4.5 m |
| 104 | 4.5 to 6.0 m |
| 105 | Providing dry trap/ granite/ quartzite/ gneiss, rubble stone soling in 15 cm to 20 cm thick layers including hand packing and compacting, etc. complete. (Bd-A-12/264) |
| 106 | Providing and laying in situ Cement Concrete M-15 of trap/granite / quartzite / gneiss metal for foundation and bedding including bailing out water, form work, compaction, curing, etc. complete. (Cement 5.90 bags / cum) Spec. No. - Bd E /1 Page No. 287 and B-7, Page No. 38 |
| 107 | Providing and laying in situ Cement Concrete of trap/ granite/quartzite / gneiss metal for RCC work in foundation like raft, grillage, strip foundation and footing of RCC columns and steel stanchions including normal dewatering, form work, compaction, finishing and curing, etc. complete. (By weigh batching and mix design for M250 and M-300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement) (RCC M-300 ) |
| 108 | Providing and casting in situ C.C. of trap / granite/ quartzite/gneiss metal of approved quality for RCC works as per detailed drawings and designs or as directed by Engineer-in-charge including normal dewatering, centering, forrn work, compaction, finishing the formed surfaces with C.M. 1:3 of sufficient minimun thickness to give a smooth and even surface wherever necessary or roughening if special finish is to be provided and curing, etc. complete. (By weigh batching and mix design for M-250 and M-300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement (RCC M-300 ) |
| 109 | Providing and casting in situ C.C. of trap/granite/ quartzite/gneiss metal of approved quality for RCC works as per detailed drawings and designs or as directed by Engineer-in-charge including normal dewatering, centering, form work, compaction, finishing the formed surfaces with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface wherever necessary or roughening if special finish is to be provided and curing, etc. complete. (By weigh batching and mix design for M-250 and M-300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement)RCC M-300 |
| 110 | Providing and casting in situ C.C. of trap / granite/ quartzite/gneiss metal of approved quality for RCC works as per detailed drawings and designs or as directed by Engineer-in-charge including normal dewatering, centering, form work, compaction, finishing the formed surfaces with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface wherever necessary or roughening if special finish is to be provided and curing, etc. complete. (By weigh batching and mix design for M-250 and M-300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement)RCC M-300 |
| 111 | Providing and fixing in position steel bar reinforcement of various diameters for RCC piles, caps, footings, foundations, slabs, beams, columns, canopies, staircases, newels, chajjas, lintels, pardies, copings, fins, arches, etc. as per detailed designs, drawings and schedules; including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required, etc. complete (including cost of binding wire). (Bd-F-17/306) c) Corrosion Resistant Steel (Fe 500) |
| 112 | Providing and fixing mild steel grill work for windows/ ventilators of 20 Kg/Sqm. As per drawings including necessary welding and painting with one coat of anticorrosive paint and two coats of oil painting, etc. complete. (Bd-U-1/537) |
| 113 | Providing rough cast cement plaster externally in two coats to concrete, brick or stone masonry surfaces in all positions with base coat of 12 to 15 mm thick in C.M. 1:4 and rough cast treatment 12 mm thick in proportion 1:11 / 2:3 including scaffolding and fourteen days curing complete. |
| 114 | Providing and applying white-wash in two coats on old/ new plastered or masonry surfaces and asbestos cement sheets including scaffolding and preparing the surface by brushing and brooming down etc. complete. |
| 115 | Providing and applying colour-wash of approved colour and shade in one coat to new surface including scaffolding, brushing and brooming down (excluding base coats of white wash) etc. complete. |
| 116 | Dewatering the excavated trenches and pools of water in the building trenches / pipeline trenches, well works by using pumps and other devices including disposing off water to safe distance as directed by Engineer-in-charge (including cost of machinery, labour, fuel), etc. complete. |
| 117 | Refilling the trenches with available excavated stuff with soft material first over pipeline and then hard material in 15 cm layers with all leads and lifts including consolidation, surcharging, etc. complete. |
| 118 | Transportation as per STATEMENT VI Including loading, unloading and stackingEarth (4.8 Curn) lead 15 Km |
| 119 | Electromechnical ItemsScreen (Manual) of size 1.6 m length x 0.5 m width of SS 304 MOC and Manual hand rake for cleaning screen of SS handle 1 m in length and cleaning area of 6 nos 5 mm SS rod of total length 200 mm straight and 50 mm of 90 degree bend. |
| 120 | Grit Pump Supplying Non-clog Submersible Pump suitable for sewage/ Liquid waste application with standard MOC and given duty points as below1 HP (Up to 9000 LPH) |
| 121 | Raw Sewage PumpSupplying Non-clog Submersible Pump suitable for sewage/ Liquid waste application with standard MOC and given duty points as below1 HP (Up to 9000 LPH) |
| 122 | NaOCI Chlorinator Pump Diaphragm Type / peristaltic type / Solenoid Max Flow Rate Upto 10LPH Power Source Electric Phase Single Material PP/PTFE (Teflon) Voltage 230 Volt Frequency 50Hz Mixing Tank of 100 Ltrs capacity- 1 No Dosing Pump-2 Nos |
| 123 | Control PanelDesigning, Supplying, Installing, commissioning & testing of PLC Panel.Including PLC with CPU & Power supply unit, power supplyb cables interfacing cards, interfacing cables, wireless modules with 25% extra quantity of all accessories. |
| 124 | Supplying and erecting Fully Automatic Star Delta starter to operate squirrel cage induction motor working on 380-440 Volt, 3 phase, 50 Hz with no volt coil, over load element, and ON-OFF push buttons, with necessary material and connected to supply, etc complete. Starter with original sheet steel encloser.> 7.5 HP & Up to 12.5 HP |
| 125 | Main power supply cable 3 core PVC insulated, PVC sheathed copper conductor flat submersible cable Supplying and erecting, Flat flexible submersible cable with, Copper Conductor, PVC insulated, and PVC sheathed.3 core 16 sq mm |
| 126 | Power cables Aluminium conductor 4 Core, XLPE/PVC insulated & armoured cable Supplying and erecting, XLPE/PVC insulated, armoured cable 1100 V grade with ISI mark Four core, solid/ stranded aluminium conductor with 6 mm thick 25 mm width M.S. spacer with G.I. Earth wire 6 sq mm, complete erected on wall / on pole with 25 X 3 mm M.S. clamps or in provided trench in an approved manner. 4 Core 6 sq mm |
| 127 | Control Panel Copper conductor PVC insulated, Unarmoured control cableSupplying and erecting Un-armoured control cable with ISI mark stranded / solid copper conductor 1.1 kV grade complete erected on wall / panel or in provided trench in an approved manner. 4 core 2.5 sq mm |
| 128 | Providing and supplying in standard lengths ISI mark Rigid unplasticised PVC pipes suitable for potablewater with solvent cement joints including cost of couplers, as per IS specification no. 4985/1988 excluding GST levied by GOI and GOM in all respect, including transportation, freight charges, inspection charges, loading, unloading, conveyance to the departmental stores and stacking the same in closed shed duly protected from sun rays and rains including cost of jointing material i.e. solvent cement, etc. complete (selffit type to be jointed with cement solvent). |
| 129 | 1) 10% of cost of pipes shall be considered for cost of PVC specials for estimate purpose only. 2) One coupler and required cement solvent shall be provided with each full length pipe cost of which is included in rates below. |
| 130 | Item No.37:Raw Sewage pump to CAMUS DistributionMain header 75 mm. 10 kg/sq.cm |
| 131 | PVC Specials- 10% |
| 132 | Item No.38:Distribution63 mm. 10 kg/Sq.cm |
| 133 | PVC Specials- 10% |
| 134 | Item No.39:CAMUS collection Main header75 mm. 10 kg/Sq.cm |
| 135 | PVC Specials- 10% |
| 136 | Item No.40:collection tributory63 mm.10 kg/Sq.cm |
| 137 | PVC Specials- 10% |
| 138 | Item No.41:CAMUS distribution63 mm. 10 Kg/Sq.cm |
| 139 | PVC Specials- 10% |
| 140 | Item No.42:Labour |
| 141 | Plumber |
| 142 | Helper |
| 143 | Providing double flange sluice valve confirming for IS- 14846 including worn gear arrangements as per test pressure, stainless steel spindle, caps, including inspection charges, transportation upto departmental store, unloading, stacking excluding GST levied by GOI & GOM in all respect etc.complete. Sluice valves - PN-1 (Without by pass) Raw Sewage pump 80 mm. |
| 144 | Providing and supplying ISI mark CI D/F reflux valves (non-return valves) of following dia including railway freight, inspection charges, unloading from railway wagon, loading into truck, transportation upto departmental stores, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. complete. Reflux valves as per 1.S.5312 Part I (1984) Without by pass arrangement-PN-1Raw Sewage pump 80 mm. |
| 145 | Bio media Items Providing, laying, spreading in layers stone aggregates of specific size as a Bio- media filter material as specified and directed by technology provider including all labour, material, loading, unloading, transportation, upto 15 Km. lead, placing the bio media in bio reactor including all taxes and duties such as royalty...etc. completeSupplying crushed metal 60 to 80 mm of trap/granite/quartzite/gneiss stone metal at the site including conveying & stacking. 15 Km Lead. Also Laying into Bio Mound Tank as directed by Vision Earthcare Pvt Ltd. |
| 146 | Supplying crushed metal 20mm of trap/granite/quartzite/gneiss stone metal at the site including conveying & stacking. 15 Km Lead. Also Laying into Bio Mound Tank as directed by Vision Earthcare Pvt Ltd. |
| 147 | Supplying 40 to 60mm of Hard Murrum at the site including cleaning and laying into Bio Mounds as directed by Vision Earthcare Pvt Ltd |
| 148 | Providing and fixing Jute Kanthan (Tarat) sceen to the scaffolding for external guniting as directed including removing the work is over etc.complete |
| 149 | Excavating the ground to required depth up to 30 CM, removing and conveying unwanted stuff to required distance as directed, filling fresh garden soil and manure in excavated area 3:1 proportion to a height 30CM mixing garden soil and manure slowly leveling watering on previous night, planting well rooted shrubs 0.5 m or as directed and mentaining till well established by watering wedding string replacing etc complete. |
| 150 | Supply, Installation and Testing of Tube Settler Packing |
| 151 | Providing supplying culture Catalyst & On site demostration as per the M/s Vision Earthcare Pvt Ltd all as specified including MOU with technology expert M/s Vision Earthcare Pvt Ltd CAMUS Patent No 414339 Technology Consultancy Charges (General Arranagement and Hydraulic Flow Diagram-Design and Drawings), CAMUS Cultures, CAMUS Catalyst, Maharashtra GO No. Serial No 2017/Sch No351/UDD-33 1 dated 27 Feb 2018 |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail