| 1 | Supply,Installation of 2 Modular box outerFrame with cover plate in existing concealed modular box. |
| 2 | Supply,Installation of 3 Modular box outerFrame with cover plate in existing concealed modular box. |
| 3 | Supply,Installation of 6 Modular box outerFrame with cover plate in existing concealed modular box. |
| 4 | Supply,Installation, Testing and Commissioning of 6 AOne way Switch in existing concealed modular box . |
| 5 | Supply,Installation, Testing and Commissioning of 6 A/10A Switch in existing concealed modular box . |
| 6 | Supply,Installation, Testing and Commissioning of 16 AOne way Switch with indication in existing concealed modular box . |
| 7 | Supply,Installation, Testing and Commissioning of 2 Module ceiling fan regulator-120 W, in existing concealed modular box . |
| 8 | Supply,Installation, Testing and Commissioning of 20A/25A AC Starter switch with start and stop in existing concealed modular box . |
| 9 | Supply, Installation, Testing and Commissioning of AC controller with 24 hours timer and 25 A Contactor with bypass option. |
| 10 | Supply,Installation, Testing and Commissioning of 32A/40A industrial area socket with DP MCB of suitable rating along with mounting box and plug top. |
| 11 | Supply, Installation of Flexible SS Conduit |
| 12 | Supply, Installation of Flexible PVC Conduit |
| 13 | Supply, Installation of 25 x 12 mm Casing Capping |
| 14 | Supply, Installation of Ceiling Rose |
| 15 | Supply, Installation of Dummy platesof 1 Module |
| 16 | Supply, Installation of Dummy platesof 2 Module |
| 17 | Supply,Installation, Testing and Commissioning of 6/16A 3-pin Socket outlets in existing concealed modular box |
| 18 | Supply,Installation, Testing and Commissioning of 6/16A 3-pin Socket with IP 66 rating outlets in existing concealed modular box/surface mounted |
| 19 | Supply,Installation, Testing and Commissioning of 25A 3-pin Socket outlets in existing concealed modular box |
| 20 | Supply, installation,Testing and Commissioning of 10A ,10kA, Type C SP MCB in existing distibution boards |
| 21 | Supply, installation Testing and Commissioning of 16 A ,10kA, Type C SP MCB in existing distibution boards |
| 22 | Supply, installation Testing and Commissioningof 25 A, 10kA, Type CSP MCBin existing distibution boards |
| 23 | Supply, installation Testing and Commissioning of 63 A ,10 kA, Type C 4P MCB,in existing distibution boards |
| 24 | Supply, installation Testing and Commissioning of 32 A ,10 kA, Type C 4P MCB,in existing distibution boards |
| 25 | Supply, installation Testing and Commissioning of 25 A ,10 kA, Type C 4P MCB,in existing distibution boards |
| 26 | Supply, installation Testing and Commissioning of 63 A ,10 kA, Type D 4P MCB,in existing distibution boards |
| 27 | Supply, installation Testing and Commissioning of 40 A ,10 kA, Type D 4P MCB,in existing distibution boards |
| 28 | Supply, installation Testing and Commissioning of 25 A ,10 kA, Type C DP MCB,in existing distibution boards |
| 29 | Supply, installation Testing and Commissioning of 16 A ,10 kA, Type C DP MCB,in existing distibution boards |
| 30 | Supply, installation Testing and Commissioning of 40 A 4P RCCB-30mAin existing distibution boards |
| 31 | Supply, installation Testing and Commissioning of 32 A 4P RCCB-30mAin existing distibution boards |
| 32 | Supply, installation Testing and Commissioning of 25 A 4P RCCB-30mAin existing distibution boards |
| 33 | Supply, installation Testing and Commissioning of 63 A DP RCCB-30mA,in existing distibution boards |
| 34 | Supply, installation Testing and Commissioning of 25 A DP RCCB-30mA,in existing distibution boards |
| 35 | Supply, installation Testing and Commissioning of 16 A DP RCCB-30mA,in existing distibution boards |
| 36 | Supply, installation Testing and Commissioning of 4 kV, 40 kA,4PType 2 Surge diverter, in existing distibution boards |
| 37 | Supply,Installation, Testing and Commissioning of 24 Way DB surface mount |
| 38 | Supply, Installlation of 8 SWG copperconductor for earthing |
| 39 | Supply,Installation, of PVC conduit of 25 mm Dia and necessary accessories like bends, junction boxesetc. |
| 40 | Supply,Installation of DLP PVC Trunking of minimum 85*50mm with all the necessary accessories like bends, flat junctions, flat angles, internal angles,external angles,wall crossing accessory etc |
| 41 | Supply, installation and testing of Circuit wiring with 2.5 sq.mm. Copper wire from DB to Switchboard of average length 30 m |
| 42 | Supply, installation and testing of AC Point Wiring with 4 Sq.mm. copperwirefrom DB to the AC control and looping to the socket, average length 25 m |
| 43 | Supply, installation and testing of Primary Power Point Wiring with 2.5 sq.mm. copperwirefrom DB to Power point of average length 30m. |
| 44 | Supply, installation and testing of Secondary power point wiring with 2.5 sq.mm. copperwire ( Located in a separate box) of average length 5 m. |
| 45 | Supply, installation and testing of Primary Light/Fan Point (including security/Area lighting) Wiring with 2.5 sq.mm. copper wire r, average length 30m |
| 46 | Supply, installation and testing of Secondary Light point wiring with 1.5 sq.mm. Copperwire of average length 10m. |
| 47 | Supply, Installation, Testing and commissioning of 1200mm Sweep,Ceiling Fan with downrod and support wire |
| 48 | Supply, Installation, Testing and commissioning of 200mm sweep, Metalic Body BodyExhaust fan with louvers |
| 49 | Supply, Installation, Testing and commissioning of 300 mm sweep, Heavy duty metallic Exhaust fan with louvers |
| 50 | Supply, Installation, Testing and commissioning of 400mm sweep,Wall mounted Fan |
| 51 | Supply, Installation ofHeavy duty double D-Hook with fastener for ceiling. |
| 52 | Supply, Installation, Testing and Commissioning of minimum 40W(minimum 4000 lumen and 100 lumen/watt) LED lighting fixture, Recess mounted( 2 feet x 2 feet) |
| 53 | Supply, Installation, Testing and Commissioning of minimum 40W(minimum 4000 lumen and 100 lumen/watt) LED lighting fixture, Surface mounted( 2 feet x 2 feet) |
| 54 | Supply, Installation, Testing and Commissioning of minimum 18W(minimum 1800 lumen and 100 lumen/watt) LED lighting fixture Surface mounted downlight , Circular shape |
| 55 | Supply, Installation, Testing and Commissioning of minimum 18W(minimum 100 lumen/watt)LED lighting fixture , Recess mounted, Circular shape |
| 56 | Supply, Installation, Testing and Commissioning of minimum 20W(minimum 100 lumen/watt) LEDbatten lighting fixture |
| 57 | Supply, Installation, Testing and Commissioning of minimum 10W(minimum 1000 lumen and 100 lumen/watt) LED batten lighting fixture |
| 58 | Supply, Installation, Testing and Commissioning of minimum 40W(Minimum 100 lumen/watt) LED, IP66,Out doorlighting fixture including the MS mounting bracketon wall / Structure for area lighting/ security lighting. |
| 59 | Supply, Installation, Testing and Commissioning of minimum 42W(minimum 100 lumen/watt) clean room LED lighting fixture Recess mounted(2 feet x 2 feet) |
| 60 | Supply, Installation, Testing and Commissioning of Surface Mounted minimum 20W(minimum 100 lumen/watt).LEDlights.(1 feetX1 feet) |
| 61 | Supply, Installation, Testing and Commissioning of PIR Motion Sensor |
| 62 | Supply, Installation, Testing and Commissioning ofExtension of existing Ti panel ofL&T panel with 6 feeders(1 No.-400 A,4P Motorised MCCB, 1 No- 400A,4P MCCB,1 No- 250A Motorised 4P MCCB,1 No-250A 4P MCCB,1 No- 100 A,4P MCCB) |
| 63 | Supply, Installation, Testing and Commissioning ofNew LT Panel with 2 incomers(1 No. 320A MCCB, 1No. 200A MCCB with 1Nobus coupler & interlocks ) and outgoing feeders(5 No. 100 A MCCB, 7 No. 63A MCCB,3 No. 40A MCCB) , 2 nos of1 pahse 6/16Asocket and plug withcontrol of 2P MCB&RCCB for ON/OFF.Bus bar should be copper including earthing , 2mm thick ness of CRCA sheetouter frame. LED indicationfor phaseR,Y & Bof Incoming & out going feedrs. Emergency stopto be provided, double door to be provided Panel control wiring should be copper2.5 sqmm- FRSLS. |
| 64 | Supply, installation, testing and commissioing of LT cables of 3.5 C x 240 sq mm, 1100V grade,XLPE extruded insulation, aluminium conductor, with FRLS sheath, round armoured cable The cable to be installed on cable tray, underground, cable trenches, pit, hume pipe. While installation of cable in cable trenches, lifting of MS cover plate /concrete cover over trenches is included in scope of work |
| 65 | Supply, installation, testing and commissioing of LT cables of 4 corex 25 sq.mm,1100V graderound armoured cable with Copper conductor,with FRLS sheath The cable to be installed on cable tray, underground, cable trenches, pit, hume pipe. While installation of cable in cable trenches, lifting of MS cover plate /concrete cover over trenches is included in scope of work. |
| 66 | Supply, installation, testing and commissioning of end termination with double compression brass gland and Heavy duty long barrel crimping type copper lugsof 3.5 C X240 Sq. mm Aluminium Conductorfor all cores |
| 67 | Supply, installation, testing and commissioning of end termination with double compression brass gland and Heavy duty long barrel crimping type copper lugs 4 C X 25 Sq. mm Copper Conductorfor all cores |
| 68 | Supply & installationof 450 mm wide ,GI ladder cable tray( thickness 2.5 mm, height 100mm) to carry power cables, & control cablesincluding bends, tees, crosses, Elbows, accessories( hot dipped GI) like nuts, bolts, couplers etcand two run 50 mmX6mmGI-Flat/strip( hot dipped GI) along the cable tray for equipment/ system earthing |
| 69 | Supply & installationof 150 mm wide ,GI ladder cable tray( thickness 2.5 mm, height 100mm) to carry power cables, & control cablesincluding bends, tees, crosses, Elbows, accessories( hot dipped GI) like nuts, bolts, couplers etcand two run 50 mmX6mmGI-Flat/strip( hot dipped GI) along the cable tray for equipment/ system earthing |
| 70 | Brick Protection of LT cable |
| 71 | Cable Route Marker |
| 72 | Provision of Earth pit withCopper plate(600mm x 600mmx 6mm)as per IS: 3043.earth excavation min. to a depth of 3 mtrfrom ground levelin all types of soilsfor supply & laying of electrode including charcoal, salt, brick masonary chamber, white wash,cast iron hinged cover & testing of earth resistance values,marking earth resistance values on the earth pit chamber. |
| 73 | Supply & Installation oftwo run 50mm x 6mm GI Flat/strip(hot dipped GI)for panel/system earthing and interconnection of earth pits |
| 74 | Supply, Installation, Testing and Commissioning of7.5kVA or above, on-line, double conversion UPS with 30 min Battery backup, external SMF batteries, battery rack and necessary cables. Warranty: Minimum Two year OEM warranty shall be applied for both UPS and batteries. |
| 75 | Earth excavation and Back fillingalltype of soilfor cable trench for laying of cables&disposal of excess earth as directed by Engineer-in-Charge . |
| 76 | Manual earth excavation & back fillingsoilfor cable trench for laying of cables |
| 77 | Hard Rock Cutting |
| 78 | Supply, Installation of 150mm dia NP2 type hume pipes. |
| 79 | Supply, Installation ofof MS Support |
| 80 | Supply, Installationof Photo Luminiscent Signages for Toilet, Exit, Staircase,etc.Board Thickness 3 mm |
| 81 | Providing and fixing Grid SystemFalse Ceiling using GYPROC- 595 x 595 x 15 mm thickCelotex- Pin Narrow Reaveal edge Model Ceiling Tiles (White color, Light Reflectance of >82% LR 1, NRC of 0.55, Fire performance of class 1, Thermal conductivity of 0.057 w/mk ) GI 600mm x 600mm Blot Slot grid ceiling system manufactured by M/s Saint-Gobain Gyproc India Limited, Consisting of main Tee of size 15 x 40 mm at every 1200 mm c/c and cross tee of size 15 x 40 mm at every 600 mm c/c and sub-cross tee of size 15 mm x 40 mm at 1200 mm c/c and wall angle of size 19 x 22 mm fixed to periphery of the wall and the above grid is suspended from the soffit with the help of soffit cleat, Rawl plug, and GI wire rod of 4mm dia with galvanized spring level clips at 1200mm centers complete all as per specification, drawing and as directed by Engineer-in-charge |
| 82 | 24 core Optical Fibre Cable (OFC): Supply, Installation, testing and commissioning of 24 Core, Single Mode, Multitube, Gelly filled,PVC insulated, Armoured, Optical Fibre Cable (OFC). Preferred makes: Legrand/ Belden/ Tyco - AMP/ CommScope |
| 83 | Light Interface Unit (LIU): Supply, Installation, testing and commissioning of 12 duplex port (LC) fully loaded,Rack mount Light Interface Unit (LIU) with all accessories. Fully loaded includes 12 Nos. duplex adapters, 24 Nos. of OFC pigtails with LC connector and fiber tray. |
| 84 | Splicing of Optical Fiber:Splicing of Single mode Optical Fiber per core |
| 85 | Supply & installationof Single mode, LC-LC, Optical Fiber patch cord of 3 meter length. |
| 86 | Network Rack (Size: 12U): Supply and installation of 12U heigh wall mounted Network rack with accessories (a) hinged glass door (b) cable manager (c) light (d) cooling fan (e) four outlet power distribution box. |
| 87 | CAT6 patch panel: Supply and installation of 24 port RJ-45, CAT6 loaded patch panel. Installation includes mounting in network rack, termination of Cat -6 UTP cable in all ports. |
| 88 | Cat-6 UTP cable: Supply, installation,testing and commissioning of Cat-6 UTP cable. Installation of cable shall be in PVC conduit and surface/ concealed conduit. |
| 89 | Supply & installation of Cat 6 UTP patch cords of Length: 1 meter |
| 90 | Supply & installation of Cat 6 UTP patch cords of Length: 3 meter |
| 91 | Two pair Telephone cable: Supply, installation, testing and commissioning of 0.5mm annealed bare copper conductor, two pair with PVC insulated telephone cable.Installation of cable shall be in surface/ concealed conduit. |
| 92 | 50 Pair Telephone Cable: Supply, Installation, termination, Testing and commissioning of 50 Pair, 0.5 mm dia Armoured Jelly filled Telephone cable annealed bare copper conductor,solid polyethylene insulated and sheathed as per technical specification. Cable shall be laid in under ground or trench /on wall or structure.Brick protectionto be provided to the under ground cable as per technical specifications & Cable shall be clamped on wall/structure , necessary accessires shall be in the scope of installation . |
| 93 | 200 pair Telephone juction box:Supply,Installation, Testing and Commissioning of 200 pair Telephone Junction box with steel frame for Krone terminal strip ( 20 nos. Of 10 Pair strips), cable entry on top and bottom (2 each) with glands and MS Powder coated box with hinge door and lock. |
| 94 | RJ45 Computer Socket module: Supply and installation of RJ45 Cat 6 Computer socket single module suitable for installing in standard modular boxes. |
| 95 | RJ11Telephone Socket module: Supply and installation of RJ11 single module suitable for installing in standard modular boxes. |
| 96 | Supply & installation ofFrame and support plate for moudlar boxes: Frame and support plate of Single outlet (single module) as per site requirement. |
| 97 | Supply & installation of Frame and support plate for moudlar boxes: Frame and support plate of Dual outlet (Two module) as per site requirement. |
| 98 | 48 Port Gigbit Ethernet Switch: Supply, Installation, testing and commissioning of 48 x 10/100/1000 base-T ports, 4 x 100/1000 Base-T/SFP combo ports, manageable switch.Warranty: Minimum One year OEM warranty. |
| 99 | 24 Port PoE Switch: Supply, installation, testing and commissioning of 24 x10/100/1000 Mbps Ethernet PoE ports +2 x 100/1000 Mbps Base-T/SFP combo ports (RJ45/SFP). Warranty: Minimum One year OEM warranty. |
| 100 | SFP Transceiver module: 1000 base -LX Single mode,1310 nm, 10K range,hot pluggable,SFP Transciever with duplex LC connector. Warranty: Minimum One year OEM warranty. |
| 101 | IP PoE Bullet Cameras (Out door): Supply, Installation, testing and commissioning of 2 MP, weather proof, PoE, IR, with 3.6/4.0 mm lense IP Bullet camera with support of H.265 or better compression with extended bracket of minimum 500mm length. Warranty: Warranty: Minimum One year OEM warranty IP 66 protection. |
| 102 | IP PoE Bullet Cameras (Indoor): Supply, Installation, testing and commissioning of 2 MP, weather proof, PoE, IR, with 3.6/4.0 mm lense IP Bullet camera with support of H.265 or better compression . Warranty: Warranty: Minimum One year OEM warranty. |
| 103 | IP PoE Dome Cameras (Indoor): Supply, Installation, testing and commissioning of 2 MP,PoE, IR, with 3.6/4.0 mm lense IP Dome camera with support of H.265 or better compression with extended bracket of minimum 500mm length. Warranty: Minimum One year OEM warranty. |
| 104 | Network Video Recorder: Supply, Installation, testing and commissioning of Network Video Recorder (NVR) :32 Channel with support for H.265 or better Compression, Minimun support for 4 hard disk bay (each bay supporting upto minimum 8 TB), Video output Port: 1 x HDMI, Keyboard and mouse. NVR shall also support standard features of CCTV monitoring such as video recording, motion detection, video backupetc. and all standard formats of video. Warranty: Minimum One year OEM warranty shall be applied. |
| 105 | Survilance Hard disk: Supply, Installation, testing and commissioning of 6 TB Survilancehard disksupportingabove supplied NVR. Warranty: Minimum One year OEM warranty shall be applied. |
| 106 | 32\" LED Monitor: 32\" LED, HD monitor suitable for above NVR with 1XHDMI, 1xVGA ports.Warranty: Minimum One year OEM warranty shall be applied. |
| 107 | Supply and laying of 40mm Dia HDPE pipe with ISImark suitable forlaying armoured Optical Fibre Cable. |