| 1 | Supplying of PVC insulated, PVC sheathed / XLPE aluminium conductor armoured under groundpower cable of 1.1 KV gradeconforming to IS 1554 part-I/7098(part-I) 1998 with up to date amendments of the following sizes. |
| 2 | 2 X 10 Sqmm |
| 3 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on wall surface as required. |
| 4 | upto 35 Sq.mm (Clamped with 1 mm thick saddle) |
| 5 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required but excluding sand cushioning and protective covering. |
| 6 | upto 35 Sq.mm |
| 7 | Supplying and fixing of light class G.l. pipe of 50 mm dia. (nominal) 3 metres length along the pole/wall for protection of under ground cable as required. |
| 8 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. |
| 9 | upto 35 Sq.mm |
| 10 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 11 | Group C |
| 12 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 13 | 8 way, Double door |
| 14 | 6 way, Double door |
| 15 | 4 way, Double door |
| 16 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 17 | Single Pole |
| 18 | Single Pole and neutral |
| 19 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 20 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 21 | Supply, installation, testing and commissioning of 1200mm sweep, BEE 5 star rated, ceiling fan with Brushless Direct Current(BLDC)Motor, class of insulation:B, 3 nos blades, 30 cm long down rod, 2 nos canopies, shackle kit, safety rope, copper winding, Power factor not less than 0.9, service value(CMM/W) minimum 6.85, Air delivery minimum 215CMM ,350RPM (tolerance as per IS:374-2019), THD less than 10% remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut, bolts,washers, temperature rise =75 degree C(max) , insulation resistance more than 2 mega ohm , suitable for 230V, 50 Hz single phase AC supply, earthing etc complete as required. |
| 22 | Supplying, installation, testing and commissioning of 1200 mm 20W LED Aluminium LTT8-20 tube with extruded Al body, PC diffuser (single side connection) and inbuilt driver with efficacy min of 100 lumens/W along with Highly robust Industrial Box type(not compact type) luminaire suitable for single T8 LED Tube and also dismantling the existing tube including giving connections etc., at the site of work.(NABL certified as per ISO/IEC specification) |
| 23 | Supplying and fixing two modular stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc as required |
| 24 | Supplying of 300 mm sweep, min. of 1350 RPM speed, min. of 1160 CMM air delivery Heavy Duty exhaust fan with Sturdy metal body with metal blades & Metal louvers for protection from birds and foreign matter etc., as required at the site of work. |
| 25 | Installing of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning,etc as required. Upto 450 mm sweep |
| 26 | Supplying, installation, Testing and commissioning of 70W LED Street light fitting including Inbuilt electronic LED driver (SMPS based constant current supply) with lower THD, Output Open / Short Circuit protection, Phase to Phase protection, Over Voltage protection, Surge Voltage protection & other safety test as per IS 15885 Part-2/Sec 13 and BIS comply made up of pressure die cast alluminium housing with toughened glass with inbuilt surge protection device and fixing on wall/truss/pole with suitable clamps and nut bolts including dismantling existing fitting and giving connection etc., at site of work as required.(ISI certified )( IP66 protection, Efficacy ≥110/120 LPW) |
| 27 | Supplying and fixing of Hot press moulded SMC junction Box of size 140x140x95 mm with 6A SP MCB, 2/4 way strip connector including testing commissioning etc. as reqd. |
| 28 | Supplying and drawing of 1.5 Sq.mm,three core PVC insulated and FRLS PVC Round Sheathed, Copper Conductor (flexible) industrial cable, 1100 Volts, conforming to IS: 694 in the existing surface/ recessed steel/ PVC conduit as required. |
| 29 | Supplying and fixing of 32 mm dia X 1.00 metres long G.I. pipe (medium class) bracket for mounting of all type of street light fitting on pole / wall / structure including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint as required. |
| 30 | Supplying and fixing 20A ,240V, SPN industrial type socket outlet with 2 pole and earth, metal enclosed plugtop along with 20A\"C\" curve,SPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc as required |
| 31 | Supplying and fixing 30A ,415V, TPN industrial type socket outlet with 4 pole and earth, metal enclosed plugtop along with 30A\"C\" curve,TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc as required |
| 32 | Dismantling of existing main board, sub-main boards, switch boards, MS Conduit Boxes, GI Wires, GI boxes, switchgears, old HPSV Fittings etc., including shifting to depot stores as required. |
| 33 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 34 | 2X10 sq. mm (19mm) |
| 35 | Dismantling of pole/ street light standard/strut embedded in brick ballast foundation etc as required |
| 36 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : |
| 37 | Two or more coats on old work |
| 38 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. |
| 39 | 12 Module (200mmX150mm) |
| 40 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 41 | 5/6 A switch |
| 42 | 3 pin 5/6A socket outlet |
| 43 | Supplying and fixing of 32 mm dia X 2.00 metres long G.I. pipe (medium class) bracket for mounting of all type of street light fitting on pole / wall / structure including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint as required. |
| 44 | Credit Items |
| 45 | Dismantled DBs and switchgears etc |
| 46 | Dismantled iron electric poles |