| 1 | Supply, laying, jointing, commissioning and testing XLPEinsulated screened PVC bedded, armoured,heavy duty underground electric cable in replacement with stranded aluminium conductor 1100 volts grade confirming to IS-7098 (Part-I-1988) laid in trenches/ducts/wall / floor / pipes/ poles including cable glands and aluminium lugsof appropriate size, PVC sleeve etcincluding dismantling of old LT UG cables complete all as directed by Enginner in -Charge for following sizes . Make :- Havells / Gloster / Finolex / Polycab |
| 2 | 300 sq mm 3.5 core . |
| 3 | 240 sq mm 3.5 core |
| 4 | 185 Sqmm 3.5 core |
| 5 | 150 sq mm 3.5 core |
| 6 | 95 sq mm 3.5 core |
| 7 | 70 sq mm 3.5 core |
| 8 | 50 sq mm 3.5 core . |
| 9 | 35 sq mm 3.5 core |
| 10 | 25 sq mm 3.5 core |
| 11 | 16 sq mm 4 core |
| 12 | NOTE :- Earth work , bricks , riddled earth , GI pipe for protection of cable will be measured & paid under under relevant items of schdule . |
| 13 | Supply and errect in vertical position Steel tubular swaged poles,type 410 SP- 31 (09 mtr long) in replacement with 300mm x 300mmx6mm mild steel plate continiusly welded to pole, final taper plug, bolts,nuts and screws and making holes as per requirementall as specified including factory painted with two coats ofblack bituminous paint internally through out and externally for embeded portion and applying one coat fo red oxide primer, making 05 Nos strip each 30 cmhigh with super enamel paint ( Black and yellow) from ground level / coping upto 1.5 m, painting with two coats of aluminium paint for the remaning height complete all as specified and directed.Note :- PCC in foundation, copping, excavation and earth work shall be measured and paid separately under relevent items of sch. |
| 14 | M & L in replacement Earthing complete with galvanized steel earth plate electrode 60 cm x 60cmx6 mm thick, buried directly in ground vertically (earth pit not less than 2.25 m deep below ground level) with top edge of the earth plate not less than 1.5m below ground level , connected to 32x6 mm GI stripas earthling lead by means blots and nuts check nuts and washers of galvanized iron and connected to main switch board including watering arrangement with PCC chamber , MS funnel, wire gauge.CI cover with frame , 50 MM dia GI pipe light grade for protection of wire/strip etc including necessary excavation in any type of strata , returning, fillingremoval of soil outside MD land ,filling ofcharcoal andsalt complete all as shown in electrical plate No. 3 of MES Sch Part I , connected to Earthing test point all as specified and directed on testing on completion. |
| 15 | M&L for cleaning of MES electric supply installations/campus by surface dressing or trimming of natural ground to remove small unequalities not exc 15 cm deep (including removing vegetation/ shrubs/brush wood/under growth) and carrying away the rubbish to a distance of not exc 50 mtr away complete at an interval of every 30 daysforthe various sub stations. Note: Spray of herbsitedeemed included in quoted rate. |
| 16 | Decarbonizing of LT indoor/outdoor Panel/feeder pillar box any type removing unserviceable MCCBs, burnt busbars, unserviceable indicator lamps, unserviceable Ammeter,unserviceable Volt meter , replacing burnt, damaged bus bar of any size and fixing proper hanging front and rear openings, welding of hinges including welding of brokieng MS sheet using extra sheetsreplace burnt thimbles with new existing size thimbles replacing with new MCCB,incluidng dismantling the existing connected cables and re-connecting the same cables complete all as specified and directedby Engr -in- charge. Note : (i)MCCBs,Bus bars,indicator lamps,Ammeter, Volt meter, will be measured & paid separately as supply only . |
| 17 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation of poles stays laying of electric cables, pipes etc and getting out in soft/loose soil complete all as specified and directed. |
| 18 | Ditto item no 6 but in hard/dense soil. |
| 19 | Removing excavated material soil to a distance not exceeding 50m and depositing where directed at a level not exceeding1.5m above the starting point complete all as specified and directed |
| 20 | Returning, filling in,including spreading, levelling watering and well ramming in layers not exceeding25cm in soft/loose soil complete all as specified and directed. |
| 21 | M & L for riddled earth forcushioning to under ground electric cable including spreading , levelling and hand punning complete all as directed.Note - Punned thickness shall only be measured & paid . |
| 22 | M& L for road cutting / foot path and making good with PCC 1:3:6 TYPE C-2 ( using 40 mm graded stone aggregate ) of 150 mm |
| 23 | Supply and laying un-reinforced precast concrete cable cover LV, Type I, flat, size 250mm x 150mm x 40mmfor Under ground cable all as specified and directed. |
| 24 | Supply and laying GI tubes light grade, galvanized, 40 mm borein repair ,laid in trenches or under floor or fixed with poles/walls for protection of electric cable all as directed |
| 25 | Ditto item no -13 but 80 mmm bore. |
| 26 | M & L for Plain cement concrete (PCC) type C21:3:6 using 40mm graded aggregate stone for making foundation of Pole/stay assembly |
| 27 | M&L for Plaincement concrete (PCC) type C11:3:6 using 20mm graded aggregate stone for making copings of Poles etc including dismantling the old coping from poles. |
| 28 | Supply only straight through joint kit , heat shrinkable type suitable for LT UG electric cable 1100 volts grade of size25 to 50Sqmm 3.5/4 core cable complete all as directed . |
| 29 | Supply only straight through joint kit , heat shrinkable type suitable for LT UG electric cable 1100 volts gradeof size from 70up to 120 sq mm3.5/4 core cable complete all as directed . |
| 30 | Supply only straight through joint kit , heat shrinkable type suitable for LT UG electric cable 1100 volts grade of sizefrom 150 to 185 sq mm 3.5/4 core cable complete all as directed . |
| 31 | Supply only straight through joint kit , heat shrinkable type suitable for LT UG electric cable 1100 volts grade of sizefrom 240 to 300 sq mm 3.5/4 core cable complete all as directed . |
| 32 | Taking down old Flood Light of any type/capacity from any height and Supply and Fix LED Floodlight fitting of capacity 250 wattsmade up of pressure die cast aluminium housing with toughned glass and high power LED\"s and secondary lenses, having system efficacy greated than 110 lumen per watts with surge protection device included. The luminaries shall be totally enclosed dust and water proof with minimum IP -66 protection pre wired up to connector including 2.5 sq mm PVC insulated copper cable for making connection (upto 9 mtr length), complete all as specified and directed by Engr-in-charge.Make :- Halonix/Crompton/Benlo/Havells. |
| 33 | All as per Item No - 21 above but of capacity 500 WattsMake :- Halonix/Crompton/Benlo/Havells. |
| 34 | S&Fin repairs Junction box of size not less then 400x300x190mm, made of high quality thermo plastic polystyrene, weather proof, dust, jet water proof, chemical, acid corrosion, impact, insulated & shock proof IP 66 / 67 for outdoor Installation with internallly embedded gasket (PUR) including the box fitted with connector 8 way 40 Amps 01 No including Emlex stud type TB 4 Nos incoming / outcoming cable at controlled with MCB SP 6 Amps 01 No & enclosed along pole including fixing with steel tubular poles with two Nos FI clamps 25mmx3mm withnuts, bolts and washers complete and making connection with 1.5 sqmm copper conductor unsheathed FRLS PVC insulated 3 core from junction box to security lights fittings duly laid inside the streel tubular pole and bracket. complete all as specified and directed by Engineer-in-Charge.Note : (40 mm bore GI pipe light grade, 3 core 1.5 sqmm cable and GI brackets will be measured separately . Make :- Sintex Cat Part No. GSJB-4030 or equivalent in Indokop / HenselNote :- Cost of flat iron clamp is deemed to include in unit rate of this items. |
| 35 | Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint. |
| 36 | Supply, install testing and commissioning in replacement factory madeout door typeLT panel board of size not less than 1.5 mtrX1mtrX0.450 mtr, 440 volts , 3 phase , 4 wire system with powder coating providedto make it dust /vermin proo,f manufactured from CPRI approved manufacturer, The panel shall be made with 3.15 mm thick CRCA sheet for outer shell and inner shell made out of 1.6 mm thick CRCAsheet,double door with front openable with locking arrangement, provision of threaded earthing stud at bottom, inner shell be compartmentalized, front openable single door system lockable. Inner shell completely vermin proof and to accommodate incoming/outgoing MCCBs, MCBs, and TPN aluminium bus and extension links. Aluminium bus bar of capacity 400 Amps- 4Nos,including neutral duly insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size/rating of epoxy resininsulator all housed in suitable bus bar chamber.All control wires shall be as per the OEM recommendations and shall be properly bunched,tied, ferrulled for proper indentification and crimped with adequate size of lugs andprovision and fixing of Voltmeter,Ammeter with built in selector switch, CTs of suitable ratio, and pilot indication lamps completealong with provision of necessary cable entry/exit boxes for all incoming and out going cables with suitable size of cable glands etc. Computer cut shelf adhesive vinyl danger notice plate having conventional symbol of bone & skull be provided. The panel shall consists of following accessories:- |
| 37 | Note : (i) Electrical connection from switchgear to bus bar would be through copper strips of suitable size.(ii) The internal electrical connection for measuring instruments would be through multi-stranded PVC insulated copper conductor cables of suitable size.(iii) The termination of incoming and outgoing cable into and from switchgear would be through properly crimped aluminumlugs of suitable rating incommensurate with that of switchgear.(iv)Cable glands would be provided for incoming & out going cables in panels.(v)The cost of fixing of the panel on suitable PCC (1:3:6) type C-1(using 20 mm graded black trap/basalt/granite stone aggregates) foundation as directed by Engineer-in-Charge is deemed to be included in the quoted rates by the contractor for the above item.(vi)The panel is to be fixed with Angle Iron Frame of size 50x50x6mm with bottam of panel having minimum 60cm height from existing ground/floor level. |
| 38 | Aluminium bus bar strips with proper colour code -04 No, 300 A cap, insulator, nuts bolts etc complete. |
| 39 | Indicator Lamp-01 Set (Set of three) |
| 40 | IncommerMCCB 4P250Amp, 415V, 36 KA Ics = 100 Icu Adjustable type - 01 No |
| 41 | Outgoing, MCCB 4P125amp, 415V, 25 KAIcs = 100 Icu Adjustable type - 04 No |
| 42 | MCBTPN 32A,10KA B CURVE - 01 Nos for Street light panel |
| 43 | Digital Voltmeter 0-500 Vand Digital Ampmeter0-400 A.with selector switich Make-Legrand/Minilac |
| 44 | Connection with Aluminium bus bar strip duly insulated with coloured sleeves /stranded copper cable of suitable size with thimbles. |
| 45 | Supply, install testing and commissioning in replacement factory madeout door typeLT panel board of size not less than 1.5 mtrX1.2mtrX0.450 mtr, 440 volts , 3 phase , 4 wire system with powder coating providedto make it dust /vermin proo,f manufactured from CPRI approved manufacturer, The panel shall be made with 3.15 mm thick CRCA sheet for outer shell and inner shell made out of 1.6 mm thick CRCAsheet,double door with front openable with locking arrangement, provision of threaded earthing stud at bottom, inner shell be compartmentalized, front openable single door system lockable. Inner shell completely vermin proof and to accommodate incoming/outgoing MCCBs, MCBs, and TPN aluminium bus and extension links. Aluminium bus bar of capacity 500 Amps- 4Nos,including neutral duly insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size/rating of epoxy resininsulator all housed in suitable bus bar chamber.All control wires shall be as per the OEM recommendations and shall be properly bunched,tied, ferrulled for proper indentification and crimped with adequate size of lugs andprovision and fixing of Voltmeter,Ammeter with built in selector switch, CTs of suitable ratio, and pilot indication lamps completealong with provision of necessary cable entry/exit boxes for all incoming and out going cables with suitable size of cable glands etc. Computer cut shelf adhesive vinyl danger notice plate having conventional symbol of bone & skull be provided. The panel shall consists of following accessories:- |
| 46 | Note : (i) Electrical connection from switchgear to bus bar would be through copper strips of suitable size.(ii) The internal electrical connection for measuring instruments would be through multi-stranded PVC insulated copper conductor cables of suitable size.(iii) The termination of incoming and outgoing cable into and from switchgear would be through properly crimped aluminumlugs of suitable rating incommensurate with that of switchgear.(iv)Cable glands would be provided for incoming & out going cables in panels.(v)The cost of fixing of the panel on suitable PCC (1:3:6) type C-1(using 20 mm graded black trap/basalt/granite stone aggregates) foundation as directed by Engineer-in-Charge is deemed to be included in the quoted rates by the contractor for the above item.(vi)The panel is to be fixed with Angle Iron Frame of size 50x50x6mm with bottam of panel having minimum 60cm height from existing ground/floor level. |
| 47 | Aluminium bus bar strips with proper colour code -04 No, 500 A cap, insulator, nuts bolts etc complete. |
| 48 | Indicator Lamp-01 Set (Set of three) |
| 49 | IncommerMCCB 4P400Amp, 415V, 36 KA Ics = 100 Icu Adjustable type - 01 No |
| 50 | Outgoing, MCCB 4P250amp, 415V, 25 KAIcs = 100 Icu Adjustable type - 01 No |
| 51 | Outgoing, MCCB 4P160amp, 415V, 25 KAIcs = 100 Icu Adjustable type - 01 No |
| 52 | Outgoing, MCCB 4P63amp, 415V, 16 KAIcs = 100 Icu Adjustable type - 05 No (for Bldg Panels BDTC area) |
| 53 | MCBTPN 32A,10KA B CURVE - 01 Nos for Street light panel |
| 54 | Digital Voltmeter 0-500 Vand Digital Ampmeter0-500A.with selector switich Make-Legrand/Minilac |
| 55 | Connection with Aluminium bus bar strip duly insulated with coloured sleeves /stranded copper cable of suitable size with thimbles. |