| 1 | Demolition of cement concrete in ground floor / paving not exceeding 15Cm thick below or above GL unreinforced complete all as specified . |
| 2 | M&L PCC 1 : 2 :4 type B-2 (using40 mm graded stone aggregate) 100 mm thick for sub base / floorand finished with even and fair / rough as per ground reqirementcomplete all as specified and direced. |
| 3 | 75mm thick cement Concrete 1:4:8 type D-2 using 40mm graded crushed stone aggregates as in floor/sub base and finished even and fair complete,all as specified and directed. |
| 4 | Dismantling floor, hearth or wall tiling any description and thickness including cement mortar bedding (but not backing) and removing rubbish off the premises. |
| 5 | M&L cement concrete tile 30CM x 30CM x 20-25mm thick with grey cement and pigment set, jointed and pointed in neat cement slurry in floors over and including cement mortar bedding 20mm thick in CM 1 : 4, complete all as specified and directed. |
| 6 | M & L for sand filling 50 mm under floors or in foundations including watering and consolidation as required complete all as specified and directed. |
| 7 | M&Lfor Machine pressed precast concrete inter locking paver blocks of any shape andsize conforming to IS 15658- 2006of 60 mm thick M-35 grade with grey cement andpigment with glosey finish andincluding removing the existing paver blocksincluding rem oving of debries out side MD land complete all as specified and directed.. |
| 8 | Demolition of brick work built in cement mortar including all quoins, cornices , concrete coping etc on brickwork complete all as specified and directed. |
| 9 | M & L for brick work in sub class \"B\" Bricks old size, straight or curved on plan exc 6m mean radius, built in cement mortar 1:4, complete all as specified and directed. |
| 10 | M&L for Brick work with sub class-\"B\" Bricks, straight or curved on plan exc 6m mean radius built in CM (1:6) Complete all as specified and directed. |
| 11 | M&L for pre-cast cement concrete1:3:6 ,type C1 using 20mm graded stone aggregate as in solid block masonry exc.100mm width and built in CM(1:4) all as specified and directed. |
| 12 | M&L for walling or random rubble , uncoursed well bonded, bedded and solidly, hearted built in CM 1:6etc complete all as specified and directed. |
| 13 | All as per item No. 12 above but except stones including removal of mortar, cleaning with water etc complete all as specified and as directed by the engineer-in-charge.Note : Old stone obtained under Item above shall be re-used under the subject items |
| 14 | Taking down cement or cement lime plaster any description on brick or stone wall etc including racking out joints hacking for keyscrbbing down with water completed all as specified and directed. |
| 15 | Material and Labour for rendering 15 mm thick cement plaster in CM (1:4) on fair faces of brick work or concrete surfaces and finished with 5 mm thickplaster, both coats to be mixed with water proofing compound @ 2% by weight of cement or as per manufacturers instructions complete all as specified & directed.(Note :- Supply only water proofing compound shall be measured and paid separately). |
| 16 | M&L for two coats of cement base paint over one coat of primer on new surface of wall including preparation of surface complete all as specified and directed. |
| 17 | M&L for onecoat of cement basewash on old surface of wall including preparation of surface complete all as specified and directed. |
| 18 | Demolition ofcement concrete reinforced of any description and in any position not otherwise specifically provided for complete all as specified and directed. |
| 19 | M&LRCC 1 : 2 : 4 type B-0(using 12.5mm graded stone aggregate) Slabs supported on walls,beams and columns in floors,roofs, landings, balconies, canopies, deck slabs and inshelves and the likesla betc complete all as specified and directed. |
| 20 | M&L RCC1 : 2 : 4 type B-1 (using 20mm graded aggregate) for cover slab MHincluding necessary form workand set in cment mortar 1 : 4,complete all as specified and directed. |
| 21 | M&L form work to sides & soffit of roof beams / top beams rough finished surface of concrete complete all as specified. |
| 22 | Supply and fix TMT bar 10mm dia and over, cut to length, bent to shape required including cranking bending, spirally or hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed confirmed to Fe 410-0 complete all as specified and directed. |
| 23 | Supply and fix TMT bar 6 to8mm dia, cut to length, bent to shape required including cranking bending, spirally or hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed confirmed to Fe 410-0 complete all as specified and directed. |
| 24 | Demolition and breaking up 150mm drain pipes (Salt glazed ware, AC or reinforced concrete) set in cement mortar including bed concrete and removal of debris including sludge if any and side MD land complete. |
| 25 | Demolition and breaking up 200mm drain pipes (Salt glazed ware, AC or reinforced concrete) set in cement mortar including bed concrete and removal of debris including sludge if any and side MD land complete. |
| 26 | Exavating intrenches in Hard / dense soil n. exe 1.5 m wide and n. exe 1.5 m in depth, for foundation etc or for shafts, wells, cess pits, man holes, pier holes etc n exe 10 sq m on plan n exe 1.5 m depth and getting out complete all as specified and directed |
| 27 | Exavating intrenches in Hard / dense soil n. exe 1.5 m wide and n. exe 3 m in depth, for foundation etc or for shafts, wells, cess pits, man holes, pier holes etc n exe 10 sq m on plan n exe 1.5 m depth and getting out complete all as specified and directed |
| 28 | M & L for cement concrete 1:4:8 type D-2, using 40 mm graded stone aggregate as in foundation complete all as specified and directed. |
| 29 | M&Lreinforced concrete pipes class NP2200 mm laid and jointed complete with collar all as specified and directed, |
| 30 | M&L for PCC 1:3:6 type C2 (using 40mm graded stone aggregate) as in bed to drain pipes 200mm dia including packing under and haunching against the sides of pipes after they are laid and tested all as specified |
| 31 | M&L salt glazed stone ware drain pipes of 150 mm internal dia laid in trenches and jointed in CM 1:1 complete all as specified |
| 32 | M&L for PCC 1:3:6 type C2 (using 40mm graded stone aggregate) as in bed to drain pipes 150mm dia including packing under and haunching against the sides of pipes after they are laid and tested all as specified |
| 33 | Returning, filling in, including spreading, levelling, watering and well raming in layer not exe 25cm complete as specified and directed. |
| 34 | Removing exavated material ourside MD land exe 1.50km but n. exe 5km and depositing where directed complete as specified and directed. |
| 35 | Dismantling of posts or struts (wood, steel or RCC ) any section including taking out embeded portion and making good distrubed ground on concrete , brick work, masonry etc and removingof demolished materials out side MD land complete all as specified and directed. |
| 36 | M&L PCC (1:2:4) type B1 (20mm graded aggrgate) as in coping, lintel bands , hold fast, string courses, water troughs and the likeetc.including weatheing, slightly rounded or chamfered angles, throating, necessary form work complete as specified and directed. |
| 37 | Dismantling of fencing wire mesh any type and size complete all as specified and directed. |
| 38 | Excavation in post holes (or similar holes) each n exc 0.5 cum and getting out, returning filling in and ramming earth or broken rubble mixed with earth around, in layers n exc 25cm, watering and removing surplus soil to a distance n exc 50m and making good surface in hard / dense soil complete all as specified and directed. |
| 39 | M&L for cement concrete type C-2 , 1 : 3 : 6 (using 40mm graded stone aggregate) in foundation and filling concrete for columns, fencing posts etc complete all as specified and directed. |
| 40 | S& F Mild steel angle iron cut to shape as directed drilling holes notching for wire as in posts and struts in fencing ,Framed work such as grills, gratings, etc.including all necessary cutting and welding etc and for similar work complete all as specified. |
| 41 | S&F for mild steel screw bolts (machine cut) with hexagonal or square heads at one end and srewed the other or screwed both ends each screwed end to be fitted wth washers and one hexagonal or square nut, not exceeding 5 cm long and diameter of neck 5 to 10mm complete all as specified and directed. |
| 42 | M&LPVC coatedchain link fencing, sizen exc 40mm x 40mm The dia of GI wire shall be 2.5mm to 3mm and thickness of PVC shall be 1mm to 1.5mm fixed to the posts complete all as specified and directed. |
| 43 | Cutting into existing man holes for connecting new drains of 150mm dia pipe and making good two pipes and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B1 and finished and reforming benching as required complete all as specified and directed. |
| 44 | Cutting into existing man holes for connecting new drain of 200mm dia pipe and making good two pipes and rendering, cutting out existing benching for and forming branch channel(1/2 round or 3/4 section) in cement concrete 1:2:4 type B1 and finished and reforming benching as required complete all as specified and directed. |
| 45 | Demolition of cement concreteof any description and in any position not otherwise spcifically provided for complete all as specified and directed. |
| 46 | Desitting/desludging completely area drain n.exc 30cm wide of any description including removing and refixing of cover slab & making good if any with same specification and removing of silt/sludge outside MD land, all as directed. |
| 47 | All as per item No. 46 above but for upto 450mm wide drain. |
| 48 | All as per item No. 46 above but for upto 600mm wide drain. |
| 49 | Dismantling wrought iron or mild steel work of any description specifically provided for gates, staircase railings, framed truss etc complete all as specified and directed. |
| 50 | M&L Mild framed works such as angles, tees , channels, etc as in fenching posts large and small gates and grills , gratings and chainlink fenching etc, including hanging gates in pillar with proper pintle hinges, stops, hand made sliding bolts ,etc complete all as specified and directed.. |
| 51 | S&F in repairsof Galvanised 2 strand steel barbed wire 2.24 mm dia barbed with 2mm dia barbs at 75mm spacing and fixing to any of standard rails straining bolts, includig securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins etc as directed |
| 52 | Restraining & resecuringof Galvanised 2 strand steel barbed wire 2.24 mm dia barbed with 2mm dia barbs at 75mm spacing and fixing to any of standard rails straining bolts, includig securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins etc as directed |
| 53 | S&Fin repairs of razer type concenrtina coil,9SWG hot galvanisedspring tensile wire 145 to 150 newton per square mm, zinc coating 250-300 gram per sqm ,dia of coil when unstretched 610mm minmumno of coils 10 per RM after laying hot dip galvanised razer ribbon tape of size 0.50 mm thick 19mm wide before wrapping of central corewire fixed with 1.66mm thick GI clips 25 nos per running meter and special nut bolts ,hold \"z\" coil together and extrra two rows parrel wire of 10 gauge complete all as specified and directed by the EIC and Dismantling of razer type concertina coil with two parallel rows of wire remove of the debris outside MD land complete all as specified and directed by EIC |
| 54 | Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings all as specified and directed |
| 55 | Dismantling wrought iron or mild steel work of any description not otherwise provided for all as specified and directed. |
| 56 | S&F Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel, post or flat sections) including distance pieces, cleats etc. Fe-410- W(Gde-E-250) quality-B including distance pieces, cleats plate etc incl required welding as per relevent IS complete all as specified and directed. |
| 57 | S&F rolled mild steel work in plates (plain or chequered) channels, square cut or notched (ordinary and countersunk) forming holes, without any attachment, Fe 410-W (Gde-E-250) quality-B, complete all as specified and directed. |
| 58 | M&L for Preparation of new steel surfaces of any des-cription, over 10cm in width or grith, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer. |
| 59 | M&L for preparation of old decorated steel surfaces ofany description not other wise described over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed. |
| 60 | S&F Pre- painted galvalume aluminum zinc coating GI basedorrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified |
| 61 | Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specifie |
| 62 | M&L Rotational moulded polyethylene water storage tanks (Cylindrical verticval with closed top) hoisted & fixed in position in repairs incl dismantling all as specified of 500 ltrs capacity complete all as specified and directed.. |
| 63 | M&L Rotational moulded polyethylene water storage tanks (Cylindrical verticval with closed top) hoisted & fixed in position in repairs all as specified of 1000 ltrs capacity complete all as specified and directed.. |
| 64 | S&F in repairsSteel rolling shutters1.25mm thick lath, with out ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer, erected in position as indicated complete gear operated type with bevel gear box and crank handle. |
| 65 | M&L Safety lever locks mild steel with 4 levers for rolling shutters |
| 66 | M&L Ball bearing for rolling shutters complete all as specified and directed. |
| 67 | Taking up or down steel tubing 15mm bore of pipe and connectionsincluding cleaning for refixing etc as required complete all as specified and directed.. |
| 68 | M&L tubes medium grade galvanised, with all fittings and fixed complete to walls or ceiling or laid in floors 15mm bore dia. |
| 69 | Taking up or down steel tubing with connectionsfor cleaning for refixing or removing to store yard complete of bore 25 mm complete all as specified. |
| 70 | S&F Supplying and laying of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified. of nomina Outer diameter of pipes25 mm complete all as specified. |
| 71 | M&L preparation of new concrete surfaces, andapplying two coats of synthetic enamel pain over one coat of primer etc , complete all as specified and directed. |
| 72 | M&L preparation of old concrete surfaces, and applying one coat of synthetic enamel paint, complete all as specified and directed. |
| 73 | Deduct Credit for Demolished/ Dismantled material Rs. (-) 85,415.00 (Minus) as listed in Schedule of CreditNote1: Tenderers will not quote against this item being a tentative amount to be considered to arrive at the \"Contract Sum\"Note 2:- The tenderer must keep in mind when quoting rates against items out in multiple store house having height 4 mts to 7 mts. Necessary scaffolding and saftey measures required during execution of work are including in this items. |