| 1 | 8.7 Dismantling |
| 2 | Dismantling the existing pole above 6 m height with brackets, clamps, insulators, stay from the c.c. foundation and making the site clear by refilling the pits with excavated materials and bringing it to the ground level. |
| 3 | Dismantling |
| 4 | Dismantling the existing cables of all types & size above 10 sq mm up to 50 sq.mm. |
| 5 | Hot Dipped Galvanized Poles & High-Mast (OH-HM) |
| 6 | Providing & erecting 9 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 155 mm A/F, top 70 mm A/F on provided foundation as per specification no. OH-PL/OPL |
| 7 | Providing and erecting galvanised 1000mm single arm sword type bracket with FRP dome and ball as per specification no. OH-PL/BKT |
| 8 | Outdoor Fittings (FG-ODF) |
| 9 | Supplying and erecting integrated LED street light fitting 120W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 13000 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT upto 6500K,THD<10%, p.f. >0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs at L70B50 including driver complete with minium 2 Years warranty as per specification No. FG-ODF/SL. |
| 10 | Excavation (CW-EXN) |
| 11 | Excavating Soft murum/Soft soil road by chiselling for preparing pit for poles stay or earth plates or for laying cables, pipes & clearing the site by removing debris & making the site good complete. |
| 12 | C.C. Foundation |
| 13 | Making cement concrete foundation in 1:3:6 cement concrete, (20 to 25) mm. stone metal duly plastered with necessary curing for complete. (pole muffing or any other purpose) |
| 14 | Making M-20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq.m at 1.5m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 9m & 10m high octagonal/conical GI pole). |
| 15 | Mini Feeder Pillar (SW-MFP)/ Street Light Control Panel (SW-STCP) |
| 16 | Supplying & erecting three phase, 415V, street light control panel upto the max load of 12kW, TPN MCB 63A, powder coated CRCA 14 SWG sheet, outdoor type, having IP54, IK10 protection suitable rating contactor, 24 hrs. astronomical time switch with minimum 5 years battery back up, auto/manual selector switch, ON/OFF push buttons, indicator lamps, control wiring, metering device, etc. for automatic operation with overcurrent, short circuit, earth fault protection on provided iron frame / CC foundation as per specification SW-STCP. |
| 17 | Plate, Pipe type Earthing (EA-EP) |
| 18 | Supplying, installing and testing earthing with galvanised iron earth plate size 60 x 60 x 0.6 cm complete with all accessories of GI materials & recording the results as per specification No. EA-EP |
| 19 | Supplying, installing and testing pipe type earthing with 40mm. dia. G.l. pipe or 20 mm dia. G.I. Rod complete with all accessories of GI materials & recording the results as per specification no. EA-EP |
| 20 | Accessories |
| 21 | Supplying and erecting GI strip of required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint in an approved manner with joints required as per specification no EA-EP. |
| 22 | LT - MCBs/ MCB Change Over Switch (SW-MCB) |
| 23 | Supplying, erecting & marking DP MCB 6 A to 32 A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-MCB |
| 24 | Bunch of Wires (WG-MA/BW) |
| 25 | Supplying & erecting mains with 3x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places as per specification no. WG-MA/BW |
| 26 | LT Cables (Aluminum) (CB-LT/AL) |
| 27 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable, 1100 V 4 core 16 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 28 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable, 1100 V 4 core 50 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 29 | Cable Enclosures (CB-CE) |
| 30 | Supplying & laying (including excavation) reinforced cement concrete pipe of NP-2 class of 150 mm diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete. |
| 31 | Supplying and laying (including excavation of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, complete. |
| 32 | Erecting & commissioning 9 Mtr.GI Octagonal pole on provided foundation including transportation from store to site of work. (Rate for Providing,erecting & commissioning as per PWD DSR 2023-24 = Rs 21847/- ; Therefore rate for only erection & commissioning = 10% of Rs.21847/-=Rs 2185/- |
| 33 | Erecting & commissioning 120 W LED Fitting on provided GI Octagonal Pole including transportation from store to site of work. (Rate for Providing,erecting & commissioning as per PWD DSR 2023-24 = Rs 9957/- ; Therefore rate for only erection & commissioning = 10% of Rs.9957/-=Rs 995/- |
| 34 | Erecting & commissioning 4 x 16 sq.mm XLPE aluminium conductor cable in provided trench through DWC pipe including transportation from store to site of work. (Rate for Providing,erecting & commissioning as per PWD DSR 2023-24 = Rs 215/- ; Therefore rate for only erection & commissioning = 10% of Rs.215/-=Rs 22/- |
| 35 | Credit for Dismantled Material |
| 36 | PVC armoured/unarmoured cables and wires (Aluminium) |
| 37 | PVC pipes/materials |
| 38 | Non-sealed transformer (SS-TR-NSL) |
| 39 | Supplying, installing, testing & commissioning 3 phase, 22/0.433 kV, 50 Hz., 100 kVA, Mineral oil immersed and naturally cooled outdoor type, aluminium wound Non-sealed transformer, delta/star connected with additional neutral brought out on load side, temperature rise should not exceed 40? by thermometer in oil and 45? by the resistance method in winding at full load rating, with HV tapping (with off load tap changer) off load +2.5 to -5 in steps of 2.5%, having 4 number of tap positions, with standard accessories complete with test certificate with losses below 499 Watts at 50% load, 1733 Watts at 100% load as per IS:1180(part 1) : 2014 with necessary permissions of Electrical Inspector, as per specification no SS- TR-NSL. |
| 40 | Cable Joints & End Termination Kits (HT Cables) (CB-JT/HT) |
| 41 | Providing and erecting Heat shrinkable outdoor termination kit for 11 kV (UE)/ 22 kV ( E ) XLPE HT cable 3x up to 95 sq. mm. with necessary material as per specification no. CB-JT/HT |
| 42 | Supplying & erecting DTC metering box for 100 KVA transformer with single core resin cast CTs and other relevent materals as per MSEDCL requirement in an approved manner |
| 43 | Plate, Pipe type Earthing (EA-EP) |
| 44 | Supplying, installing and testing earthing with galvanised iron earth plate size 60 x 60 x 0.6 cm complete with all accessories of GI materials & recording the results as per specification No. EA-EP |
| 45 | Accessories |
| 46 | Supplying and erecting GI strip of required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint in an approved manner with joints required as per specification no EA-EP. |
| 47 | HT Cables (CB-HT) |
| 48 | Supplying , erecting & terminating XLPE insulated galvanised steel formed wire armoured (strip) cable 22 kV(E), 3 x 95 sq. mm. aluminium conductor laid in provided trench / pipe as per specification no. CB-HT |
| 49 | Cable Enclosures (CB-CE) |
| 50 | Supplying & erecting G.I. pipe ‘A’ class 75 mm dia. for enclosing XLPE armoured cable on wall/pole as per specification no. CB-CE |
| 51 | Supplying & laying (including excavation) reinforced cement concrete pipe of NP-2 class of 150 mm diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete. |
| 52 | Supplying & laying (including excavation) half round reinforced cement concrete pipe of NP-2 class of 150 mm diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete. |
| 53 | Supplying & erecting inline cut point end pole D. P. Structure for 22/0.415 kV, 100 KVA Transformer with R.S.J. Pole 2 Nos. of size 100 x 116 mm x 11 Mtr. Long with suitable Distribution Box of C.R.C.A. Sheet 16 SWG (size 4 Sq. Mtr.) with 4 Pole MCCB 100 Amps as incomer & 6 Nos.100 Amps Kitkat for outing circuits. Transformer D.P. Structure includes the A. B. Switch 200 Amps, D.O. fuse Set & L.A. Set. 2 Nos. Top channel of size 100 mm x 50 mm for erection of A.B. Switch & 2 Nos. Base channel of size 100 mm x 50 x mm for erecting Transformer. Channel of size 75 x40 mm for erecting D.O. Fuse Set, L.A., A.B. Switch handle etc. Angle of size 50 x 50 x6 mm for erecting Distribution Box , Transformer Belt etc. as per drawing(min. 176 Kg. iron work ) with necessary clamps, Nut-bolts. Vee cross arm, top clip, insulators, stay etc. complete with caution board & barbed wire D.P. Structure shall be erected in c.c. foundation complete. |