| 1 | The work of safe carriage of the following material with loading/unloading from store centre Darshan Nagar to site of work. (Approx. Distance 0 to 60 Km.) |
| 2 | ST Pole 11 Mtr. long |
| 3 | PCC Pole 8.5 Mtr. Long |
| 4 | ACSR Rabbit Conductor |
| 5 | 11 KV XLPE Cable 3x185 sqmm |
| 6 | 11 KV Cable Jointing Kit Outdoor 3x185 sqmm |
| 7 | 11 KV Cable Jointing Kit Staight Through 3x185 sqmm |
| 8 | L.T. XLPE Cable1x630 sqmm |
| 9 | Transformer 400 KVA |
| 10 | Other Line material i.e. cross arm / conductor / pin insulator / stay / earthing/cable Box etc. except A.B Cable. |
| 11 | Dragging of ST/PCC Pole as per RESPO Norms. |
| 12 | Fabrication and Erection of Double Pole Support on ST/PCC Pole including grouting with 1:4:8 ratio Cement, sand & Brick Ballast& including digging of pit and fixing of all accessories clamp & earthing as per RESPoNorms.(Cost of clamps borne by contractor) |
| 13 | Fabrication and Erection of Single Pole Support on ST/PCC Pole including grouting with 1:4:8 ratio Cement, sand & Brick Ballast& including digging of pit and fixing of all accessories clamp & earthing as per RESPoNorms.(Cost of clamps borne by contractor) |
| 14 | Stringing, Sagging, binding and jumpering of ACSR Rabbit Conductor as per RESSPO Norms |
| 15 | Grouting and Binding of Stay in 1:4:8 ratio with cement, sand and brick ballast including cost of all grouting materials as per RESSPO Norms |
| 16 | Earthing of Poles as per RESPO Norms |
| 17 | Shifting of 63 KVA Transformer |
| 18 | Mounting of 400 KVA Transformer as per RESPO Norms |
| 19 | Laying of underground 11 KV 3x185 sq mm XLPE Cablein Normal Soil by digging of trench 1050 mm deep, 750 mm wide including supply of required material as fine sand, Ist class bricks as per norms. (All the material will be supplied by the contractor except 11 KV XLPE cable) |
| 20 | Hanaging,Hosting & clamping of G.I. Pipe, channel, nut & Bolt 3x185 mm2 XLPE 11 KV cable as per RESSPO Norms (cost of all accessories will be borne by contractor) |
| 21 | Installation of Heat Shrinkable Type cable jointing kits Outdoor end Termination suitable for 11 KV XLPEcable 3x185 mm2 confirming to IS ESI-09-13-IS-13573 of 1992 amendment I&II VDE-0278 of latest version there of if any. ( Jointing Kit supplied by Dept.) |
| 22 | Installation of Heat Shrinkable Type cable jointing kits Staight Through end Termination suitable for 11 KV XLPEcable 3x185 mm2 confirming to IS ESI-09-13-IS-13573 of 1992 amendment I&II VDE-0278 of latest version there of if any. ( Jointing Kit supplied by Dept.) |
| 23 | Connection of L.T. XLPE Cable |
| 24 | Providing of Trolly with Fencing |
| 25 | Supply and Laying of G.I. Pipe 6\"\" dia |