Tender For Annual Plan-Providing Pumpset And Electrification At Arivayal Dwss - Meenangadi Gp-Wayanad-General Electrical Work
Tender Value
1.11 Lakhs
Estimated cost
Bid Submission
20 Mar 2025
0 days left
EMD
2790
Bank guarantee accepted
Document Fee
555
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
meenangadi → Kerala
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Annual Plan-Providing Pumpset And Electrification At Arivayal Dwss - Meenangadi Gp-Wayanad-General Electrical Work
BOQ
| Sl. No. | Item Description |
| 1 | Electrical |
| 2 | OD438549/2024-2025:Supply, installation testing and commissioning of 5 HP Vertical open well submersible pump set 2880 rpm at rated voltage 3 phase 415V 50HZ AC supply at 16-74 Mtr head delivery size 50 mm or nearest size having 21.6 - 1.8 discharge and 4.5 LPS at 50 Mtrs head using leak proof materials as required and suspended on existing rope/steel rope including fixing G.I. / uPVC Column heavy duty Pipe for Submersible Pumps as delivery pipe connected one by one to the motor up to the bottom of the well using leak proof materials as required with necessary supports on both sides of the motor including giving connection as per the direction at site. (Texmo/CRI/Kirloskar/Deccan) |
| 3 | OD438548/2024-2025:Supply, Installation, Testing and Commisioning of DOL MUG Starter Panel for 5HP Submerssible motor comprising of Relay, LED Indicator, Voltmeter, Ammeter, Contactor, Capacitor etc as required. L&T |
| 4 | OD438544/2024-2025:Supply threading, laying and joining of 63 mm/nearest size Submersible Column/HDPE Pipe for submersible pump, approved make specials as delivery pipe using required leak proofing materials etc. as required. |
| 5 | 90.6.6.3:Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.4 sq mm |
| 6 | OD438538/2024-2025:Supply and providing 63 mm/nearest siz dia Gun Metal Non return valve (ISI) |
| 7 | OD438543/2024-2025:Supply and providing 63 mm/ nearest size dia Full way valve (ISI) |
| 8 | OD438546/2024-2025:Supply and providing 63 mm/nearest sizedia Flange set |
| 9 | OD438539/2024-2025:Supply and laying of 20mm or nearest size Nylon rope |
| 10 | OD438541/2024-2025:Supply and providing 63 mm/nearest sizestainless steel Hose Collar with hose clip |
| 11 | OD438547/2024-2025:Supply and fixing flat iron clamps made from 2 nos. 50x6 mm flat iron clamp of 50 mm with suitable size bolt and nut for fixing delivery pipe on the top of the well as required |
| 12 | 2.17:Supplying and fixing TP sheet steel enclosure on surface/ recess along with 16/25/32amps 415 volts \"C\" curve TP MCB complete with connections, testing and commissioning etc. as required. |
| 13 | 90.11.1.14:Supply and installation ofsheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43) |
| 14 | 2.13.1:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 15 | 2.15.2:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 16 | 2.10.4:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole |
| 17 | 2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole |
| 18 | 1.14.9:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required4 X 6 sq. mm + 2 X 6 sq. mm earth wire |
| 19 | OD438545/2024-2025:Supply and installation of dust and vermin proof Three-phase sintex motherboard (GS MB6535) 650*350*250 and to fix kseb meters, fuse unit, CTs, etc. as required including fixing it on the wall, making good the damages, color washing, etc. as required |
| 20 | OD438540/2024-2025:Supplying and fixing 32A, 2 way Neutral link mounted on DMC/SMC base with connection, in the existing meter board |
| 21 | OD438542/2024-2025:Supplying and fixing 32A, Bakelite HRC fuse with HRC fuse link with connection, in the existing meter board |
| 22 | 5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 23 | 5.13:Providing and laying earth connection from earth electrode with 4.00 mm dia copper wire in 15mm dia G.I. pipe from earth electrode including connection with copper thimble excavation and re-filling as required. |
| 24 | 5.17:Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required. |
| 25 | OD438561/2024-2025:Supply, providing and fixing 2 x 25 x 3mm GI strip test joint and providing 25x6mm brass nut and bolt etc. and connection as required for earthing system |
| 26 | OD438562/2024-2025:Supply, providing and fixing 25 x 3mm GI Strip earth lead from the test joint to earth plate |
| 27 | 1.21.3:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm |
AI Tender Summary
Tender Timeline
Mar 13, 2025
11:30 IST
Tender Published
Tender notice published.
CompletedMar 20, 2025
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedMar 22, 2025
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender