| 1 | Taking down old unserviceable point wiring, (light, fan, socket or power) complete including fittings & fixtures such as switch, ceiling rose, pendants, regulator, socket, etc., and making good the disturbed surfaceof wall, floors, ceiling etc to match with the existing including touch up of paint/white wash complete all as specified and as directed. |
| 2 | M & L for Point wiring with 1.5 Sq mm single core copper conductor FRLS PVC insulated unsheathed 1100 Volts multistranded drawn through PVC rigid conduit and its accessories of suitable size, heavy grade ISI marked concealed on walls /roof and MS pressed steel terminal boxes modular type of 1.0 mm thick of suitable size duly painted with red oxide metal primer including fixing/grouting sunken and making the adjacent surfaces smooth through POP work & painting as per site requirement incl provision of modular cover plates for mounting the switches / sockets/ regulators etc including running up of 1.5 Sq mm multistranded copper conductor FRLS PVC insulated cable as earth continuity conductor along with wiring and connecting to the common earth dolly for One light point controlled by one, one way switch 5 Amps complete all as specified and as directed.Make of Wires : Polycab / Havells / Finolex or equivalent |
| 3 | Description all as per Item No 2.00 above but for One Ceiling Fan / exhaust fan point controlled by one, one way switch and regulator complete all as specified and as directed. |
| 4 | Description all as per Item No 2.00 above but for One 3 pin 5 Amps switch socket outlet point controlled by one switch on the same board complete all as specified and as directed. |
| 5 | Description all as per Item No 2.00 above but for One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent board complete all as specified and as directed. |
| 6 | Description all as per Item No 2.00 above but for One bell point controlled by one bell push button 5 Amps complete all as specified and as directed. |
| 7 | Description all as per Item No 2.00 above but for One light point controlled by two, 2-way switches 5 Amps complete all as specified and as directed. |
| 8 | Description all as per item No 2 here in before butusing 2.5 Sqmm single core copper conductor cable of multistranded FRLS PVC insulated unsheathed 1100 volts grade for 5/15 Amps switch socket combination point incl running of2.5 Sqmm multistranded copper conductor FRLS PVC wire as earth continuity conductor along with wiring and connecting to the common eath dolly complete all as specified and as directed..Make of Wires : Polycab / Havells / Finolex or equivalent |
| 9 | M & L for Point wiring with 1.5 Sq mm copper conductor multistranded FRLS PVC insulated unsheathed 1100 Volts multistranded drawn through and including rigid PVC caping and casing surface type andaccessories of suitable size ISI marked and terminal boxes modular type of 1.0 mm thick of suitable size including fixing/grouting modular surface box as per site requirement incl provision of modular cover plates for mounting the switches / sockets/ regulators etc including running up of 1.5 Sq mm multistranded copper conductor FRLS PVC insulated cable as earth continuity conductor along with wiring and connecting to the common earth dolly for One light point controlled by one, one way switch 5 Amps complete all as specified and as directed.Make of Wires : Polycab / Havells / Finolex or equivalent |
| 10 | Description all as per Item No 4.00 above but for One Ceiling Fan / exhaust fan point controlled by one, one way switch and regulator complete all as specified and as directed. |
| 11 | Description all as per Item No 4.00 above but for One 3 pin 5 Amps switch socket outlet point controlled by one switch on the same board complete all as specified and as directed. |
| 12 | Description all as per Item No 4.00 above but for One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent boardcomplete all as specified and as directed. |
| 13 | Description all as per Item No 4.00 above but for One bell point controlled by one, one way bell push button 5 Amps complete all as specified and as directed. |
| 14 | Description all as per Item No 4.00 above but for One light point controlled by two, 2-way switches 5 Amps complete all as specified and as directed. |
| 15 | Description all as per item No 4 here in before butusing 2.5 Sqmm single core copper conductor cable of multistranded FRLS PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket cobmination point incl running of2.5 Sqmm copper conductor FRLS PVC wire as earth continuity conductor along with wiring and connecting to the common eath dolly complete all as specified and as directed.Make of Wires : Polycab / Havells / Finolex or equivalentMake of Casing Caping : Modi / Prince / Sudhakar / Prestoplast or equivalent |
| 16 | S & F Modular switch 1 way 6 A, 1 Module complete all as specified and as directed. |
| 17 | S & F Modular switch 1 way 16 A, 1 Module complete all as specified and as directed. |
| 18 | S & F Modular Socket 6A-2/3 pin combined 2 module complete all as specified and as directed. |
| 19 | S & F Modular Socket 6A/16-2/3 pin combined 2 module complete all as specified and as directed. |
| 20 | S & F Modular Fan step regulator, 80W-2 Module complete all as specified and as directed. |
| 21 | S & F Modular Bell Push 6 A, 1 Module complete all as specified and as directed. |
| 22 | S & F Modular switch 2way 6 A , 1 Module complete all as specified and as directed. |
| 23 | S & F ceiling rose three terminal surface bakelite type AC 50 Hz 230 volts of size 65 x 50 mm complete all as specified and as directed. |
| 24 | S & F in repairs Bell, Ding Dong AC 230 volts, single pole complete all as specified and as directed. |
| 25 | M & Lfor submain wiring withsingle core PVC insulated FRLS multistranded copper conductor cable of size 2 x 4.0 Sqmm drawing into and includingrigid non metallic PVC conduit, medium grade not less than 20mm dia ISI marked ivory colour with all conduit fittings and fixing accessories and 4.0 Sqmm FRLS multistranded copper conductor cable as continuous earth wire incl taking out old wire complete all as specified and as directed.Make of Wires : Polycab / Havells / Finolex or equivalentMake of Conduit & its accessories : Modi / Prince / Sudhakar / Prestoplast or equivalent |
| 26 | M & L for submain wiring withsingle core PVC insulated FRLS multistranded copper conductor cable of size 4 x 6.0 Sqmm drawing into and includingrigid non metallic PVC conduit, medium grade not less than 20mm dia ISI marked ivory colour with all conduit fittings and fixing accessories and 6.0 Sqmm FRLS multistranded copper conductor cable as continuous earth wire incl taking out old wire complete all as specified and as directed.Make of Wires : Polycab / Havells / Finolex or equivalentMake of Conduit & its accessories : Modi / Prince / Sudhakar / Prestoplast or equivalent |
| 27 | M & L for SPN enclosure with two pin and earth plug and socket with 240 volts 20 Amps SPNMCB including removal old unsv one complete all as specified and as directed. |
| 28 | S & F in replacement sheet metal enclosure MCBDBSPN8 way with 200 Amps rated bus bar 240 volts double door with magnetic locking system including refixing / fixing of incoming & outgoing MCBs and making smooth the wall surfaces complete all as specified and as directed.Make : L&T / Legrand / Havells or equivalent |
| 29 | S & F in replacement sheet metal enclosure vertical MCB DBTPN 4 way with 200 Amps rated bus bar 415 volts double door with magnetic locking system including refixing / fixing of incoming & outgoing MCBs and making smooth the wall surfaces complete all as specified and as directed.Make : L&T / Legrand / Havells or equivalent Note for Item No 18.00 & 19.00:- (i) New MCBs if required for replacement shall be measured and paid seperately under appropriate item as \"\"Supply only\"\" (s) of this schedule. However labour element involved in replacementis included in unit rate quoted against this Item. (ii)Rates for refixing old serviceable MCBs are deemed to be inclusive in above quoted rates. |
| 30 | Supply only MCB SP 6 to 32 Amps 240V 10 KA.\"C\" Series complete all as specified and as directed.Make : L&T / Legrand / Havells or equivalent |
| 31 | Description all as per Item No 20.00 above but MCB SPN 32 Amps 240V 10 KA.\"C\" Seriescomplete all as specified and as directed. |
| 32 | Description all as per Item No 20.00 above but MCB TP 32 Amps 415V 10 KA.\"C\" Series complete all as specified and as directed. |
| 33 | Description all as per Item No 20.00 above but MCB TPN 63 Amps 415V 16 KA.\"C\" Series complete all as specified and as directed. Note:- MCBs under item No 20.00 to 20.30 will have to suite upon with the base of the existing Panel / DB as per site requirement. |
| 34 | S & F in repairs switch piano single pole flush type 5 Amps, 230 volts including removal of existing unsv one complete all as specified and directed. |
| 35 | S & F in repairs switch socket combination flush type multipurpose 2/3 pin 5 Amps 2 in 1, 230 Voltsincluding removal of existing unsv one complete all as specified and as directed. |
| 36 | S & F in repairs switch socket combination 2 in 1 multipurpose 3/5 pin 5/15 Amps flush type universalincluding removal of existing unsv one complete all as specified and directed. |
| 37 | S & F in repairs stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as reqd.including removal of existing unsv one complete all as specified and as directed. |
| 38 | S & F in repairs Bell push, piano flush type, 5 Ampsincluding removal of existing unsv one complete all as specified and as directed.Note for Item Nos 21.00 to 25.00 :- (i)Make good of disturbed surface is deemed to be included in quoted rates.(ii) All wire connections in switch/socket/regulator/bell push is deemed to be included in the quoted rates. |
| 39 | S & F wall mounted LED 18/20 watts 6500 K with out put of 1800 lumens , boxtype (decorative) light fitting, 230 volts with extruded aluminium heat sink provided for efficient heat dissipation and intregrated electronic driverconnector block etc complete with all accessories internally pre wired andnecessary mounting arrangements, provision of new 3 core multistrandedcopper conductor of size 23/0.193 from ceiling rose to fitting with integral LED tube 4\" x 18 watts including removal old existing unsv tube light fitting complete all as specified and as directed.Make :- Philips, Wipro, Havells, Jaguar, CG |
| 40 | S & F Ultra bright LED Tubelight 18/20 watts 6500 K with out put of 1800 lumens(single side connection) with very high efficacy suitable for installation in existing tubelight G13 lamp holders to give glare free light with necessary wiring and removal old existing unsv tube from fitting complete all as specified and as directed. Make :-Bajaj Philips, Wipro, Havells, Syska, Jaguar, CG or equivalent |
| 41 | S & FEnergy saving new generation 10 watts LED bulk head fitting IP 65 luminaire with opal diffuser pre wired andnecessary mounting arrangements , provision of new 3 core multistrandedcopper conductor of size 23/0.193 from ceiling rose to fitting including LED bulb and removal old existing unsv tube light fitting complete all as specified and as directed.Make :-Bajaj, Philips, Wipro, Havells, Syska, Jaguar, CG or equivalent |
| 42 | S & F Surface mounting10 Watt LED Luminaries with epoxy white powder coated CRCA sheet steel housing with reeded translucent acrylic diffuser and1 x 10 Watt LED fittingincluding taking down old unserviceable fittings any type complete all as specified and as directed .Make : Bajaj, Philips, Wipro, Havells, Syska, Jaquar, CG or equivalent |
| 43 | Taking out the existing any typefittings on ceilings and S & F 36 Watt LED Luminaire suitable for 600x600mm modular ceiling grid including frame of suitable size of above LED light with high efficiency PMMA diffuser gives soft glare free light with available lumen output from 3600 total lumen.The 36 W system shall be operating at 220-240v AC supply having internal driver .IP20,surge protection 2KV ,ambient temperature -20 to 45 degree C, frequency 50 to 60 Hz ,The system efficacy must be between80-100 lumen /watt ,with 70% lumen maintenance upto 50000 Br Hrs with uniform visually comfortable light output at 150 degree beam spread , CRI minimum 80. PF should be greater than0.95 , THD < 10% . Indivisual LED\"s should not be visible for glare free output ,colour temperature 6500k complete all as specified and as directed. Make :-Bajaj, Philips, Wipro, Havells, Syska, Jaquar, CG or equivalent |
| 44 | Supply only LED Driver suitable for existing recess monted panel type 36 W LED light fittings complete all as specified and directed. Note :Drivers shall be techincally compatible for existing type of fittings & frame size shall be matched to existing fittings. |
| 45 | S & F Copper Cable conductor 1.5 Sqmm PVC round sheathed (flexible) cable complete all as specified and as directed. |
| 46 | S & F Copper Cable conductor 2.5 Sqmm PVC round sheathed (flexible) cable complete all as specified and as directed. |
| 47 | S & F Copper Cable conductor 4.0 Sqmm PVC round sheathed (flexible) cable complete all as specified and as directed. |
| 48 | S & F Rigid non-metallic PVC conduit/ casing caping of required size exclusive of boxes (junction/terminal) but inclusive of all tees, bends,elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. complete all as specified and as directed. |
| 49 | Taking down the Ceiling fans/ Exhaust fans of any model, size & sweep carefully from its original position and dismantlingmotor and over hauling complete by cleaning all dust / grease with kerosene or petrol, & replacement of unserviceable bearings, bushes, split pins and nut and bolts and applying new grease for bearings, reassembling the motor and fixing the blades, testing and refixing the same complete all as specified and as directed.Note : Any Parts required for replacement shall be measured and paid seperately under appropriate item as \"\"Supply only\"\" (s) of this schedule. However labour element involved in replacementis included in unit rate quoted against this Item.(ii). Any unforeseen minor repair and minor parts like MS Clamps, split pins, base frames, nuts, bolts etc that are not covered under Item No-35 (a) to (e) but required to complete the repair work / smooth functioning of Fan Motor shallbe deemed to be included with the unit rate .Transportation of Stator / Rotorparts for machining & rewinding, shaft / bushingfor machining , welding , turning at lathe shop at Port Blair are also deemed to be included with unit rate.(iii). Rewinding of stator / rotor of motor, any machine workwhere involved shall be measured and paid separetely against relevant item of this schedule. |
| 50 | Supply only following spares of ceiling / exhaust fan of any model, size & sweep to incorporate against each Item No-16 Schedule \"A\"here-in-above complete all as specifed & directed(a) Supply only ball bearing suitable for ceiling fan upto 1400 mm sweep complete all as specified and as directed. |
| 51 | (b) Supply only ball bearing suitable for Exhuast fan upto 450 mm sweep complete all as specified and as directed. |
| 52 | (c) Supply only rubber bush for C/fan complete all as specified and as directed. |
| 53 | (d)M&Lforrewinding the motor of ceiling Fan 1200mm/1400mm Sweep by unscrewing without damaging any parts, rewinding the same with fine quality of super enamelled copper winding wire of suitable size & Capacity including,varnishing,drying etc,andrefixingthe stator and rotor perfectly to rotate smoothly and connection alongwith fixing of 2.5 MFD fan capacitor complete including taking out burned unserviceable copper winding wirecomplete all as specified and as directed. |
| 54 | (e)M&Lforrewinding the motor of Exhaust Fan 300 / 450 mm Sweep by unscrewing without damaging any parts, rewinding the same with fine quality of super enamelled copper winding wire of suitable size & Capacity including,varnishing,drying etc,andrefixingthe stator and rotor perfectly to rotate smoothly and connection alongwith fixing of suitable fan capacitor complete including taking out burned unserviceable copper winding wirecomplete all as specified and as directed.Note for item 37.30 & 37.40:- Rates for incorporation of new fan capacitor of suitable capacities for smooth runing of fans are deemed to be inclusive in the quoted rates. |
| 55 | Supply only in repairs oil capacitor 2.5 MFD capacity including removal of unserviceable ones complete all as specified and directedMake : Tibcon / Epson / Havells or equivalent |
| 56 | Supply only in repairs oil capacitor 4 MFD capacity including removal of unserviceable ones complete all as specified and directedMake : Tibcon / Epson / Havells or equivalent |
| 57 | Taking down electric water heater (geyser) of any capacity from existing system, disconnected inlet and outlet water connection for leakage complaint and repair to water inner tank by means of brazing/welding etc. to arrest the leak and refixing the inner tank in outer shell with proper filling of glass wool as heat resistance material, suitable quantity,and refixing the geyser at its original location complete all as specified and as directed. |
| 58 | Supply & fix in repairs indicators of Geysers upto 50 ltrs. Capacity of any make, model & type complete all as specified and directed |
| 59 | Supply & fix in repairs safety valve plug made out brass metal with fusible lead, inner thread type suitable for existing geyser of any type, capacity & model complete all as specified and as directed. |
| 60 | S & F in repairs heating element for 1.5 KW rating as required at site including rubber washers (ISI marked), Triangular/round shape, with pocket for thermostat complete all as specified and as directed. |
| 61 | S & F in repairs heating element for 2.0 KW rating as required at site including rubber washers (ISI marked), Triangular/round shape, with pocket for thermostat complete all as specified and as directed. |
| 62 | S & F in repairs thermostat ISI marked suitable for the Geysers 25 ltrs. to 50 ltrs capacity,20 Amps, 240 Volts AC, adjustable type,210 mm long or nearest size as per sample complete all as specified and as directed. |
| 63 | S&F PVC connections 15 mm size with PTMT nuts of length 300 mm has inlet for cold water with brass nuts at both ends complete all as specified and as directed. |
| 64 | S&F PVC connections 15 mm size with PTMT nuts of length 300 mm with stainless steel wire has outlet for hot water with nuts at both ends complete all as specified and as directed. |