| 1 | SUB HEAD-I (WIRING) |
| 2 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. (Group B) |
| 3 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (i) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 4 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (ii) 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 5 | SUB-HEAD-II (FITTING AND ACCESSORIES) |
| 6 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, “C” curve including connections, painting etc. as required. |
| 7 | Supply, installation, testing and commissioning of 20 watt LED tube fittings comprises of extruded channel in thermally conductive material ,high translucent serrated milky white diffusers used to get glare free and smooth light distribution, efficiency :100lm/w and LED tube directly on ceiling/ wallincluding connection with 1.5 sq. mm FRLS PVC insulated copperconductor single core cable etc as required. |
| 8 | Supplying,Installation, testing and commissioning of heavy duty exhaust fan, metalic body 230V,300 mmsweep,single phase including making the hole to suit the size of the above fan, making good the damage i/c P/F louver and shutter complete with frame for exhaust fan of size connections,testing and commissioning etc as required. |
| 9 | Supply, installation, testing and commissioning of 10 watt LED tube fittings comprises of extruded channel in thermally conductive material ,high translucent serrated milky white diffusers used to get glare free and smooth light distribution, efficiency :100lm/w and LED tube directly on ceiling/ wallincluding connection with 1.5 sq. mm FRLS PVC insulated copperconductor single core cable etc as required. |
| 10 | Providing and fixing of 12 watt surface mounted LED fitting square/Round directly on ceiling/ wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. . |
| 11 | Providing and fixing of 50 watt LED flood light made up of pressure die cast aluminium housing with toughened glass and high power LEDs and secondary lenses with IP66 protection, system efficiency >110/120LPW, 10KV SPDversion to be ordered separatelyincluding connection, testing commissioning etc as required. |
| 12 | Providing and fixing of electric storage water heater of 25 ltr of 2 KW ,240 Volt ,50 HZ i/c fasteners with nut, bolts, washers and connection pipe with connection, testing commissioning etc as required . |
| 13 | SITC of 1.5 Tonhot and cold Air conditioner220 Volt , 50 Hz ,copper winding including all accessories with 4KVA stablizer etc as required |
| 14 | SUB-HEAD-III (MCBs & DBs) |
| 15 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) (6 way, Double door) |
| 16 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (Single pole ) |
| 17 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (Double pole ) |
| 18 | SUB-HEAD-IV (EARTHING) |
| 19 | Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 20 | Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. |
| 21 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required |
| 22 | SUB-HEAD-VII (PANELING AND CABLELING) |
| 23 | SITC of various sizes water protected outdoor (Water proof)huttype compartmentalized type double door cubical panelboth side opening havingdepth up to 450 mmsuitable for 415 Volt, 3 phases, 50 Hz made out of 2mm thick CRCA sheet with required hardware duly painted with powder coated .Panel having separate detachable gland plate, angle iron base frame made out of 50mmx50mmx5mm angle iron of suitable size of the feeder pillar (minimum height 60cm), hinged door, both side opening with locking arrangement, earth bar/stud, led pilot light for phase indicator (R,Y,B) on top, 200A/415V 4 strip aluminum bus bar duly PVC sleeved, connection inter–connection with 25% extra current carrying capacity busbars to MCCBs spreader links and with solid copper conductor cable 10 sqmm/ solid aluminium rodfor connection toMCBs and heavy duty connectors of required current carrying capacity to be fixed back side including incoming/Outgoing cables connection for three and single phaseMCBs where as required, testing on loadand marking of location for incoming and out going distribution i/c grouting the legs in existing floor with 1:3:6 cement concrete foundation and dsimantling the existing panel, incoming/outgoing cable connections etc complete as required i/c dismentling the existing feeder pillar and UG cable. (Panel should beas per design &drawing approved by Engg in charge).LED light min 5 watt with on/off switch to be provided in the panel. |
| 24 | Supplying and laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of alluminume armoured 3.5 x 35 sqmm direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. |
| 25 | Supplying and laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of alluminume armoured 2 x 25 sqmm direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. |
| 26 | Supplying and Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of alluminume armoured 2 x 25 sqmm in the existing RCC/ HUME/ METAL pipe as required. |
| 27 | Supplying and Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of alluminume armoured 3.5 x 35 sqmm in the existing RCC/ HUME/ METAL pipe as required.. |
| 28 | Supplying and laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of alluminume armoured 2 x 16 sqmm direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. |
| 29 | Supplying and Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of alluminume armoured 2 x 16 sqmm in the existing RCC/ HUME/ METAL pipe as required. |