| 1 | Excavation in trenches in hard / dense soil not exceeding 1.5 mtr in depth and not exceeding 1.5 mtr wide and getting out including trimming of sides, for laying of cables & foundation of poles, stay assembly, complete all as specified and directed by Engr-in-Charge. |
| 2 | Returning filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm thick, complete all as specified and directed by Engr-in-Charge. |
| 3 | Removing excavated material to a distance not exc 50m and depositing where directed at a level not exc 1.5m above the starting point, complete all as specified and directed by Engr-in-Charge. |
| 4 | Taking out old unserviceable/serviceableun-reinforced concrete PCC cable covers from excavated trench all as directed by the Engineer-in-Charge. Note:- Serviceable un-reinforced concrete PCC cablecover kept in safe custody for reuse at site and unserviceable un-reinforced concrete PCC cable cover through in low lying area. |
| 5 | Laying only old reinforced PCC cable cover of any size as retrieved from serial item No- 04 above, complete allas directed by Engineer-in-Charge. |
| 6 | M&L for factory made un-reinforced pre cast concrete cable protection cover LV class type - I with size 250mm x 150mm x 40mm laid across the cable (i.e. width of cover along the length of cable) for UG cable protection on the top of the sand cushioning, complete all as specified and directed by Engr-in-Charge. |
| 7 | M&L for sand cushioning with layer of sand 8cm thick before laying of cable and 10cm after laying of cable in trenches complete all as directed and sand cover to UG cable, complete all as specified and directed by Engr-in-Charge.Note: Only punned thickness shall be measured and paid. |
| 8 | S&F galvanized iron pipe of 50 mm nominal dia light grade fixed to poles with clamps nuts, bolts and washers or laid under road crossing or fixed to wallincluding painting with two coats of aluminium paint over a coat of red oxide paint, complete all as specified and directed. Note : The cost of MS clamp, nut, bolt, washer and GI fittings etc shall be inclusive in the item rate. |
| 9 | Taking out old LT under ground cable from trenches / floor / road / wall / pipe / pole of any size and description incl joint, complete all as specified and directed by Engr-in-Charge. |
| 10 | Supply, laying, testing and commissioning of LT UG cable XLPE insulated PVC sheathed galvanized steel strip armoured electric power cable with stranded aluminium conductor 1100 volts grade 120 sq mm 3.5 core confirming to IS:7098 (Part-I), suitable for earthed system, laid in duct/trench/along pole/wall etc including nuts, bolts, washers, saddles & screws etc and making connection, complete all as specified and directed by Engr-in-Charge.Note : 1. The cost of Al thimbles/lugs and cable gland etc is included in quoted rate and no extra payment will be made for it. 2. Excavation, earth work, sand cushioning and brick protection will be measured and paid separately under respective items. |
| 11 | Description all as per Srl item No. 10.00 here-in-before but for cable size of95 sqmm 3.5 core. |
| 12 | Description all as per Srl item No. 10.00 here-in-before but for cable size of 70 sqmm 3.5 core. |
| 13 | Description all as per Srl item No. 10.00 here-in-before but for cable size of 50 sqmm 3.5 core. |
| 14 | Description all as per Srl item No. 10.00 here-in-before but for cable size of 25 sqmm 4 core. |
| 15 | Description all as per Srl item No. 10.00 here-in-before but for cable size of 16 sqmm 4 core. |
| 16 | Description all as per Srl item No. 10.00 here-in-before but for cable size of 16 sqmm 2 core. |
| 17 | Description all as per Srl item No. 10.00 here-in-before but for cable size of 10 sqmm 2 core. |
| 18 | M&L for taking out unserviceable under ground cable of any size from trenches with brick protection for fault rectificaton and relaying the same after rectifying the defect or jointing complete all as specified and directed by Engr-in-charge.Note : Excavation , earth work,PCC cover and sandshall be measured and paid separately under respective item |
| 19 | Supply and fix in replacement of cable jointing kit for 1100 volt (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3.5/4 core XLPE armoured aluminium conductor cable of size 70-150 sq mm complete all as specified and directed by Engr-in-charge. |
| 20 | Description all as per Srl item No. 19.00 here-in-before but of size 25 to 50 Sqmm |
| 21 | M&L for painting of LT Panel of any size and type by applying two coats of synthetic enamel paint super quality (Smoke grey) using spray gun aftersraping old paint and and writingdetails of incoming and outgoing switchgear complete all as specified and directed. |
| 22 | Supply and fix in repair off load change over switch415 volt 50 Hz confirm to IS-13947-3 with enclosure and side handle of cap 400 Amp four pole including takind down old switch complete all as specified and directed by Engr-in-charge. |
| 23 | Supply and fix in repair off load change over switch415 volt 50 Hz conform to IS-13947-3 with enclosure and side handle of cap 200 Amp four pole including takind down old switch complete all as specified and directed by Engr-in-charge. |
| 24 | supply and fixing in repairMCCB 100 amps capacity, 415 V, TPN, 25 KA including taking out US MCCB complete all as directed,Make Havells Cat part No. IHLASF0100 or equivalent in /L&T/C&S |
| 25 | Supply and fixing in repairMCCB 63 amps capacity, 415 V, TPN, 16/25 KA including taking out US MCCB complete all as specified and directed by Engr-in-charge. |
| 26 | S&F in repair MCCB, 4 pole, 400 Amps, 415 Volts , 36 KA adjustable thermal and magnetic setting complete all as specified and directed by Engr-in-charge. |
| 27 | Description all as per Srl item No. 26.00 here-in-before but of capacity 250 Amps 4 pole, 35 KA |
| 28 | Description all as per Srl item No. 26.00 here-in-before but of capacity 200 Amps 4 pole, 25 KA |
| 29 | Description all as per Srl item No. 26.00 here-in-before butt of capacity 100 Amps 3 pole, 25 KA |
| 30 | Description all as per Srl item No. 26.00 here-in-before but of capacity 125 Amps 3 pole, 25 KA |
| 31 | Supply, installing, testingand commissioning Factory made outdoor LT feeder piller box, double door type of suitable size, padestal mounted, CPRI approved totally enclosed, dust and vermin proof, Front and rear openable type made of 3.15 mm thick CRCA sheet and having proper locking arrangement duly paintedto both internal and External surfaces with super enaleled paint over a coat of red oxide and suitable for 500 volts, 50 Hz, 3 phase 4 wire system and comprising ofthree phase aluminium busbarr of current carrying capacity 200 Amps and 01 No. 4 Pole 100 Amps MCCB for incoming ond outgoing connection mounted on angle iron legs of size 50 x 50 x 6 mm x 80 cm long embedded inPCC 1:3:6,including excavation / preparation of ground complete connecting UG cable with cable glands of suitable size complete all as specified and directed by Engr-in-charge. |
| 32 | Supply, installing, testingand commissioning Factory made outdoor LT feeder piller box, double door type of suitable size, padestal mounted, CPRI approved totally enclosed, dust and vermin proof, Front and rear openable type made of 3.15 mm thick CRCA sheet and having proper locking arrangement duly paintedto both internal and External surfaces with super enaleled paint over a coat of red oxide and suitable for 500 volts, 50 Hz, 3 phase 4 wire system and comprising ofthree phase copperebusbarr of current carrying capacity 400 Ampsmounted on angle iron legs of size 50 x 50 x 6 mm x 80 cm long embedded inPCC 1:3:6,including excavation / preparation of ground complete connecting UG cable with cable glands of suitable size including the following:- |
| 33 | (i) MCCB 160A, 4 pole, 415 volts,36 KAbreaking capacity with thermal adjustable setting -01No. (IC). (ii)MCCB 100A, 4 pole, 415 volts,25 KAbreaking capacity with thermal adjustable setting -01Nos (OG).(iii) MCCB 63A, 4 pole, 415 volts,25 KAbreaking capacity with thermal adjustable setting -02Nos (OG).(iv) Digital LCD display volt meter range from 0-500 volt with selector swicth - 01 No(v) Digital LCD display ammeter range from 0-200 Amp with selector switch and CTs200/5 Amps- 01 No(vi) Phase indication lamp (Set of Three)- 03 Nos (RYB)(vii)PCC 1:2:4 (Nominal mix) type B1 using 20mm graded aggraegate as in foundation for fixing of panel.(viii) Panel drawing shall be got approved from GE before placing order. |
| 34 | Earthing complete withgalvanized steel earth plate electrode 60 cmx 60 cm x 6 mm thick buried directlyin ground (earth pit notless than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 metres below normal ground level,connecting to theGalvanised earth lead wire 4.0 mm dia by means of bolts, nuts , check nuts and washers of galvanized iron andsteelearth wire protected by provision of GI lightgrade pipe40 mmbore including provision of concrete pitmade from PCC ( 1:2:4) type B-1 (using20 mm graded stone aggregate) with 40mm thick cover of RCC 1:2:4 reinforced with XPM (Weight not less than 4 Kg/Sqm) and frame of angleiron40 x 40 x 6 mm and handle of 6 mmdia MS barmade to shape, GI light grade 20 mmbore pipefor watering perforated atbottom, 1.50metre long placed on top edge of earth plate, common salt &charcoalfilling, withfixing arrangement , funnel, wire mesh and earthwork in hard/dense soil, returning filling in and removal of surplus soilto a distance notexceeding50 metres, all as perelectrical plate No 5 of SSR 2009 Part-I and connecting to Poles all as specified or indicated including testing and taking down old earthing complete all as specified and as directed by Engineer-in-Charge. |
| 35 | Dismantling and taking down unserviceable / defective street light fitting / Flood light fitting of any wattage alongwith mounting bracket, flat iron clamp, nuts bolts etc from overhead LT poles complete all as directed. |
| 36 | S&F LED street light luminaire of 70 Watt capacity, made of single piece pressure die-cast aluminium housing with high power LED with lens for proper light distribution luminiaries, IP 66, with toughned glass cover and incl control gear etc, with and incl making all electric connection, complete all as specified and directed by Engineer in charge. |
| 37 | Description all as per item Ser No. 35.00 here-in-before but of capacity 35 Watt |
| 38 | S&F LED flood light luminaire of 100 Watt capacity, made of single piece pressure die-cast aluminium housing with high power LED with lens for proper light distribution luminiaries, IP 66, with toughned glass cover and incl control gear etc, with and incl making all electric connection, complete all as specified and directed by Engineer in charge. |
| 39 | S&F LED flood light luminaire of 200/210 Watt capacity, made of single piece pressure die-cast aluminium housing with high power LED with lens for proper light distribution luminiaries, IP 66, with toughned glass cover and incl control gear etc, with and incl making all electric connection, complete all as specified and directed by Engineer in charge. |
| 40 | S&F in replacement of street light fitting bracket, 1.5 mtr long made out of galvanized iron pipe of 40 mm dia size light grade complete with and incl 02 nos MS clamp made of MS flate iron of 50 x 6 mm size with nut, bolts, washer etc with and incl two coats of aluminum paint over a coat of red oxide primer complete all as specified and directed by Engr-in-charge. |
| 41 | M&L for preparation old (exposed) painted surfaces of existingLT steel tubular street Lightpole, struts including cross arms, clamps etc complete and applying two coats of aluminium paint over a coat of red oxide primer over the ground and making 30cm wide stripwith black and yellow paint including numbering of HT/LT poles at a height of 1.5 mtr above ground level as per existing having 15mm width and 50mm bold letterincluding Marking Red Stip painting on HT Poles etc. complete all as specified and directed by Engr-in-charge. |
| 42 | M&L 1.5 sqmm copper conductor twin core cable for connection of the street light with junction box / Over head LT line complete all as specified and as directed by Engineer-in-Charge. |
| 43 | M&L in replacement, junction box outdoor type of size 280 X 170 X 130MMmade out of Plastic sheet of thickness not less than 1.6 mm having hinged front opening door with two nos aluminium strip bus bar fitted on resin based insulator and flat iron fixing clamp of size 25mmX3mm and complete painted with two coat of synthetic enamel aluminium paint over a coat of red oxide primer complete all as specified and as directed. |
| 44 | Supply and fixing in repair 30Watt LED solar street light fitting fixed to existing pole, including taking down old fitting complete all as specified and directed by Engr-in-charge. |
| 45 | S&F in repair 100AH, 12volt LMLA battery, suitable for long backup, including taking down old battery of any type, complete all as specified. Make: Exide / Amaron / Power zone |
| 46 | S&F in repairs Solar light kit suitable for upto 30Watt solar lights, fixed in repair, complete all as specified. Make: CG/Surya /Bajaj / Philips / Havells |