Construction Of I.T.I Nit -V At Faridabad. (Rough Cost Estimate For The Work Of Pdg. Fire Alram System)
BOQ
| Sl. No. | Item Description |
| 1 | SITC of Micro processor based 2 wire fault tolerant, networkable type fire alarm / detection control panel ( having nos. of 2 loops to suit minimum 20% extra over the nos. of fire detectors. The panel shall be able to give location of all fire / fault conditions of addressable units via the address codes. Further, the panel must be able to automatically switch ON/OFF respective control module when ever any alarm is triggered. The panel shall have rectifier, loop cards, minimum 160 character L C D unit/ 5.7’’TFT to indicate Fire / Fault Signal with address and analog output, external/inbuilt printer to log all fire or fault events complete in allrespects. The Panel Shall be sheet Steel power coated, sealed to IP30. The Panel shall have 20 Zones with individual LED Indicators, expandable to 80LED Indicators. The Panel shall have 3 Serial Ports. The panel shall have a built in power supply and battery charger along with maintenance free 24 AH,2 x 12 volt SMF lead acid batteries capable of running for a minimum of 24 hours with battery charger complete as required. And conforming to BS5839 standards and Duly Approved by EN 54/UL/VDS/ as per specifications complete in all respect up to the entire satisfaction of Engineer-in – charge of workMakes : Bosch / Siemens cerberus/ EATON |
| 2 | SITC of controller unit 6 -zone system pre - amplifier 240W inbuilt amplifier with single or dual channel operation. Two input channels for call stations, universal input for microphone/ line, with speach optimized tone control, there inputs for BGM selection and music optimized tone control, front panel zone selection for BGM and call station zone selection for calls, S/N (flat at max volume) 63DB (mic): 70 dB (line), S/N (flat at min volume/ muted) 75 dB CMRR) 40dB (50 Hz-20 kHz), Line input 3 x, Master optput 1 x, Frequency response 50 Hx to 20 kHz (plus 1 / - 3 dB) complete as required complete in all respect upto the entire satisfaction of Engineer in charge of the work.Make : Bosch/ Heinrich/ Honeywell |
| 3 | Supply Installation Testing & Commissioning of of Booster amplifier 480 watt frequency response : 60 Hz to 15 khz (plus 1/3 db), Inputs : XLR and phone jack, input 1, Input 24, IMpendence : 20 Kg, SEnsitivity : 1 V balanced, S/N : ) 85 dB complete as required complete in all respect upto the entire satisfaction of Engineer in charge of the work. Make : Bosch/ Heinrich/ Honeywell |
| 4 | S/I/T/C ofCelling Mount Speaker with Plastic Mount or without mount as per site requirement for operation 6 Watts Make Honeywell/ Bosch/Henrich |
| 5 | SITC of addressable multisensor detector with a combination of Opticaland Thermalincluding mounting base, auto addressing feauture asrequired.Detetctor should have 2 as per NFPA 72 style 7 wiring requirements (one for incoming and one for outgoing line) for maintaining operational availability of all elements in the loop in the event of a short circuit and to meet style 7 requirements. High resistance to electromagnetic effects in accordance with EFSG agreement EFSG/F/97/005 .Detector should monitor Electromagnetic interference and report to the panel - current and average values. EMC safety for detector shall be 50 V/m.Shall be EN54/ VDs/UL certification. (Detectors without Inbuilt Isolators may be considered with an additional Isolator Module after 20 devices) Make: Bosch / Siemens Cerberus / EATON |
| 6 | Supply, Installation, Testing & commissioning of addressable Heat detector with fixed andrate of raise feature including mounting base with LED etc. complete as required.Each Detector should have 2as per NFPA 72 style 7 wiring requirements (one for incoming and one for outgoing line) for maintaining operational availability of all elements in the loop in the event of a short circuit and to meet style 7 requirements. High resistance to electromagnetic effects in accordance with EFSG agreement EFSG/F/97/005 .Detector should monitor Electromagnetic interference and report to the panel - current and average values. EMC safety for detector shall be 50 V/m.Shall be EN54/ VDs/UL certification. (Detectors without Inbuilt Isolators may be considered with an additional Isolator Module per detector) Make: Bosch / Siemens Cerberus / EATON |
| 7 | SITC of intelligent Analog Addressable type Manual Call Point having Surface or flush mounting option fully compliat to EN 54 having Rotary Decade switches for addressing with back box for mounting as required conforming to BS5839 standards and duly approved by EN54/UL/VDS required to complete the job in all respect up to the entire satisfaction of Engineer – in Charge of work. Make: Bosch / Siemens Cerberus / EATON |
| 8 | SITC of Addressable Loop powered sounder with strobe / flasher complete with mounting base as required conforming to BS5839 standards and duly approved by EN54/UL/VDS required to complete the job in all respect up to the entire satisfaction of Engineer – in Charge of work. Make: Bosch / Siemens Cerberus / EATON |
| 9 | SITC of Analog Addressable type Active Repeater fire alarm panel with Backlit LCD Display, having controls for reset, mute, Accept, Silence alarms and self test conforming to BS5839 standards and Duly approved by EN54/UN54/VDS with all labour and material required to complete the job in all respect up to the entire satisfaction of Engineer – in Charge of work. Make: Bosch / Siemens Cerberus / EATON |
| 10 | SITC of Glow Type EXIT Sign Board photo luminescent of size 300 mm x 250 mm x 1.5 mm rigid sheet signage containing Zink Sulphate as bare chemical class – 1 material PSPA fixed on 3 mm acrylic sheet on both side showing marking (running man, Arrow and Exit) and hanged with the ceiling with chain and fastener including cost of labour & material required to complete the job in all respect up to the entire satisfaction of Engineer-in-Charge of work Make : Giolite/Pearl/ Devi |
| 11 | SITC of Addressable Monitor Module for monitoring of a line with EOL resistor/ Potential free contact/ voltage monitoring shall be EN54/UL/VDS approved. (In case of 2 monitoring features in one module (points) each point shall be consider separately for payment).Make: Bosch / Siemens Cerberus / EATON |
| 12 | SITC ofAddressable Control Relay Module with flexible network structures with a maximun switching current of 1A @ 30V DC. Shall beEN54/UL/VDS CertificationMake: Bosch / Siemens Cerberus / EATON |
| 13 | SITC of UL/EN54/LPCB listed and FM Approved Line Isolator for Isolating the section of circuit in case of short in the addressable Loop wiring Make: Bosch / Siemens Cerberus / EATON |
| 14 | SITC of minimum 1000 Mtr. Range Siren provided at the roof of the building with separate power suppl, relay etc. with all accessories required to complete the job in all respect up to the entire satisfaction of engineer incharge. Make: National/Kheraj |
| 15 | Supply & erection of FIRE EXTINGUISHERS duly hang on wall with necessary hook complete in all respect (Make: Safex/Minimax/ Ceasefire) ABC Dry power type fire Extinguishers of 6 kg. capacity |
| 16 | Co2 type fire extinguishers of 4.5 Kg capacity |
| 17 | Supply and erection of PVC Insulated and PVC round sheathed multi core annealed bare copper conductor industrial flexible cables for voltage grade 1100 Volts conforming to IS: 694:2010 complete in all respect upto the entire satisfaction of Engineer in charge of the work2 core PVC round sheathed copper size 1.5 sq mm |
| 18 | Supply and erection of PVC conduit pipe ISI marked (Medium) recessed in wall /ceiling etc. including cost of PVC bends, inspection box and all other material required to complete the job in all respect to the entire satisfaction of Engineer-in-Charge of work. (As per HSR 2021 item no. 23.7.6.2) 25 mm dia |
| 19 | Supply & erection of On-Line- UPS rating 6.0KVA, indicative backup time 100 minutes with isolation transformer suitable for single phase AC input & single phase AC output, floor mounted type complete in all respect upto the entire satisfaction of Engineer in charge of the work. Make Microtek/ Emerrson / Eaton |
| 20 | Supply & erection of 12 volt 42Ah SMF battery complete in all respect upto the entire satisfaction of Engineer in charge of the work. Make Exide/ Amaron/ Luminious |
| 21 | Supply & erection of 16 mm angle MS stand of 55 kg. weight of dimension 40mm (L) x 50mm (H) x10 mm (W) duly painted used to accomodate 16 nos.12 volt 42Ah SMF batteries complete in all respect upto the entire satisfaction of Engineer in charge of the work |
AI Tender Summary
Tender Timeline
Mar 11, 2025
11:30 IST
Tender Published
Tender notice published.
CompletedMar 20, 2025
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedMar 21, 2025
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender