| 1 | Compost Pit (46 number of pits)Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. |
| 2 | Providing and laying in position cement concrete of specified gradeexcluding the cost of centering and shuttering - All work up to plinthlevel :1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 3 | Brick work with common burnt clay modular bricks of class designation 7.5 in foundation and plinth in:Cement Mortar 1:6 (1 cement : 6 coarse sand). |
| 4 | Brick work with common burnt clay F.P.S. (non modular) bricks of classdesignation 7.5 in superstructure above plinth level up to floor V level inall shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 5 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from naturalsources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 6 | Soling (or sub base) of well burnt soling bricks including filling of interstices and rolling.(Old size bricks, one layer laid on flat.) |
| 7 | 15 mm cement plaster on the rough side of single or half brick wall of mix : 1:6 (1 cement: 6 fine sand) |
| 8 | White washing with lime to give an even shade |
| 9 | Applying priming coat: |
| 10 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. |
| 11 | Providing & fixing UV stabilised fiberglass reinforced plastic sheet roofing up to any pitch, including fixing with polymer coated \"J\" or \"L\" hooks, bolts & nuts 8mm dia. G.I. plain/bitumen washers complete but excluding the cost of purlins, rafters, trusses etc. The sheets shall be manufactured out of 2400 TEX panel rovigs incorporating minimum 0.3% ultra-violet stabiliser in resin system under approximately 2400 psi and hot cured. They shall be of uniform pigmentation and thickness without air pockets and shall conform to IS 10192 and IS 12866.The sheets shall be opaque or translucent, clear or pigmented, textured or smooth as specified. |
| 12 | Providing and fixing bolts including nuts and washers complete |
| 13 | SEPARATION ROOM / CHAMBER Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:5:10 (1 cement: 5 coarse sand (zone-III) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 14 | Galvanized wire mesh of average width of aperture 1.4 mm and nominal dia of wire 0.63 mm |
| 15 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 16 | GI sheet 0.8 mm thick confirming to IS 277:1992 at bottom |
| 17 | Mild steel plates 2mm thick for front open lid |
| 18 | Welding by gas or electric plant including transportation of plant at site etc. complete. |
| 19 | Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete |
| 20 | Providing and fixing ISI marked oxidized M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete : |
| 21 | ELECTRONIC EQUIPMENT REQUIRED AT SITEProviding and fixing ISI marked oxidized M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete : |
| 22 | The equipment / facilities to be provided at each Customer Handling Cell are proposed : Computer with in-built modem & fax software |
| 23 | The equipment / facilities to be provided at each Customer Handling Cell are proposed : Printer |
| 24 | The equipment / facilities to be provided at each Customer Handling Cell are proposed : Telephone (land line) |
| 25 | The equipment / facilities to be provided at each Customer Handling Cell are proposed : Wireless/ Mobile phone |
| 26 | The equipment / facilities to be provided at each Customer Handling Cell are proposed : Complaint logbook |
| 27 | The equipment / facilities to be provided at each Customer Handling Cell are proposed :Table |
| 28 | The equipment / facilities to be provided at each Customer Handling Cell are proposed : Chairs |
| 29 | INTERNAL ELECTRIFICATION IN ALL BUILDINGSPVCsinglecoresheathedcableWiring withcopperconductorcablesInstove enamelledStee l Conduit .One light point or one fan point controlled by one switch with cables 1.5 sq. mm size.Group A |
| 30 | PVCsinglecoresheathedcableWiring withcopperconductorcablesInstove enamelledStee l Conduit .One light point or one fan point controlled by one switch with cables 1.5 sq. mm size.Group B |
| 31 | Wiring for light point with 1.5 Sq.mm FR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit alongwith 2 No 2.5 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required. |
| 32 | Wiring for light point with 1.5 Sq.mm FR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit alongwith 2 No 2.5 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required. |
| 33 | Supplying and fixing of following sizes of PVCconduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm |
| 34 | Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required.75x75x50mm |
| 35 | Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required.147x93x47 |
| 36 | supply and fixing following modular base & cover plate on existing modular metal boxes etc as required. 4/5 module |
| 37 | Supply and fixing following modular switch and socket on the existing modular plate & switch box including connections but excluding modular plate etc as required3 pin 5/6 amp socket outlet |
| 38 | Supply and fixing following modular switch and socket on the existing modular plate & switch box including connections but excluding modular plate etc as requiredTelephone socket outlet |
| 39 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection, painting etc asrequired |
| 40 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection, painting etc asrequired |
| 41 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 15/16 amps modular socket outlet and 15/16 amps modular switch, connection, painting etc as required |
| 42 | Supply and fixing call bell/ buzzer suitable for D.C/ A.C single phase 230 volts complete as required. |
| 43 | Supply and fixing 3 pin, 5 amp. Ceiling rose on the existing junction box/ wooden block including connection etc as required. |
| 44 | Supply and fixing brass batten/ angle holder including including connection etc as required |
| 45 | Installation, testing and comissioning of ceiling fan, ancluding wiring the down rods of standard length(upto 30 cm) with 1.5sq mm FR PVC insulated, copper conductor single core cable, including providing and fixing phenolic laminated sheet cover on fan box etc as required |
| 46 | Installation , testing and commissioning of pre wired,flourescent fitting/compact flourescentfitting of all types, comlete with all accessories and tube etc directly on ceiling/wall, including connection with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable and earthing etc as required. |
| 47 | Installation , testing and commissioning of prewired, flourescent fitting/compact flouredcent fitting of all types, comlete with all accessories and tube etc. including supplying and fixing ball and socket arrangement 2no down rods of 20mm dia X 1.6mm thick steel conduit upto 30cm lenth painting and wiring the down rods and connection with 1.5 sq mm FR PVC insulated, copper conductor, single core cable and earthing etc as required. |
| 48 | Installation of exhaust fan upto 510 mm sweep in the existing opening including making the hole to suit the size of the above fan making good the damage connection testing commissioning etc as required. |
| 49 | Extra for cutting and threading of G.I pipe heavy guage down rod for ceiling fan etc. as required |
| 50 | Supply and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper busbar, neutral busbar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powdermpainted including earthing etc as required. 2 way single door |
| 51 | Supply and fixing 6 amps to 32 amps rating 240 volts \"B\" series miniature circuit breaker suitable for lighting and other loads of following poles in the exsisting MCB DB complete with connection testing and commisssioning etc. as required 6/32 amps, single pole B series |
| 52 | Providing and fixing 4 mm dia copper wire on surface or in recess for loop earthing as required |
| 53 | EXTERNAL ELECTRIFICATION FOR MSW DISPOSAL SITEMaterial & Labour Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-22 (8.5 metres long) |
| 54 | Eaves gutter and pipes any description, exc 60 cm girth including holderbats, distance pieces, etc. (length measured over bends, branches etc.) Aluminium paint (each coat) |
| 55 | Fixing only street light fitting, for 70/80 watt vapour or sodium vapour lamp, complete with ballast and capacitor comprising of cast aluminium housing, a pair of aluminium reflectors, a highly transparent clear acrylic cover hinged to the canopy at one end and fixed by means of single spring action at the other, suitable for mounting on 40mm or 50mm dia. G.I. mast or bracket arms with pole fixing attachments and fixing of lamp |
| 56 | Supply and fixing of junction box of size280 X 170 X 130 mm with hinges and locking arrangement & MS clamp made of 50 X 6 mm flat complete in all respect. |
| 57 | Supply and laying of following sizes Al. conductor PVC insulated armoured seathed cable of 1100 V grade at a depth of 750 mm B. G. LDitto, but sec area 35 sq. mm. (3 core) |
| 58 | Supply and laying of following sizes Al. conductor PVC insulated armoured seathed cable of 1100 V grade at a depth of 750 mm B. G. LDitto, but sec. area 16 sq. mm. (2 core 16 sqm) |
| 59 | supply and fixing of G.I. pipe of 80 mm dia along the pole for protection of under ground cable as required |
| 60 | Ditto, but using galvanised iron strip 25×4mm as earthing lead. |
| 61 | Supply and fixing of feeder pillar of M.S cubicla box of size 100 x 75 x 40 cm made from 2 mm M.S sheet using angle of size 40 x 40 x 6 mm duly hinged and locking arrangement, painting two coats of enameled paint over red oxide primer providing aluminium Bus-bar or suitable size with 100 A/415 V TPN rewirable type main swithc with cement concrete foundation providing 1 Mtr GI pipe on 100 mm dia complete in all respects as per direction of E/I. |
| 62 | Supply and making of earth main hole of size 1\" x 1\" and 2\" deep with 1\" x 1\" CI chamber brick work etc |
| 63 | Supply and making of earth main hole of size 1\" x 1\" and 2\" deep with 1\" x 1\" CI chamber brick work etc |
| 64 | BAILING MACHINESupply and installation of Balling machine of required capacity including all acesseries complete as per direction of Engineer-in-Charge |
| 65 | CONVEYOR BELTSupply and installation of Conveyor Belt of required capacity including all acesseries complete as per direction of Engineer-in-Charge |