Tender For Demolition And Reconstruction Of Balance Work Of Kv School Building Of Ordnance Factory Chanda Under Ge Pulgaon
Tender Overview
Project Description
Demolition And Reconstruction Of Balance Work Of Kv School Building Of Ordnance Factory Chanda Under Ge Pulgaon Demolition And Reconstruction Of Balance Work Of Kv School Building Of Ordnance Factory Chanda Under Ge Pulgaon
BOQ
| Sl. No. | Item Description |
| 1 | Note:-Please refer schedule \"A\" notesbefore quoting the tender. |
| 2 | GENERAL SUMMARY |
| 3 | Lump sum price worked out by the contractor for BUILDING WORKS as listed in Schedule ‘A’Part- I (Ref prepriced schedule attached seperately) |
| 4 | Lump sum price worked out by the contractor for INTERNAL WATER SUPPLY WORKS as listed in Schedule ‘A’Part- II (Ref prepriced schedule attached seperately) |
| 5 | Lump sum price worked out by the contractor for INTERNAL ELECTRIFICATION WORKS as listed in Schedule ‘A’Part- III (Ref prepriced schedule attached seperately) |
| 6 | Lump sum price worked out by the contractor for EXTERNAL WATER SUPPLY WORKS as listed in Schedule ‘A’Part- IV (Ref prepriced schedule attached seperately) |
| 7 | Lump sum price worked out by the contractor for EXTERNAL ELETRIC SUPPLY AND DG SET WORKS as listed in Schedule ‘A’Part- V (Ref prepriced schedule attached seperately) |
| 8 | Lump sum price worked out by the contractor for ROAD PATH CULVERT & HARDSTANDING WORKS as listed in Schedule ‘A’Part- VI (Ref prepriced schedule attached seperately) |
| 9 | Lump sum price worked out by the contractor for AREA DRAINAGE WORKS as listed in Schedule ‘A’Part- VII(Ref prepriced schedule attached seperately) |
| 10 | Lump sum price worked out by the contractor for SEWAGE DISPOSAL WORKS as listed in Schedule ‘A’Part-VIII(Ref prepriced schedule attached seperately) |
| 11 | Lump sum price worked out by the contractor for COMPOUND WALL , FENCINGAND GATE WORKS as listed in Schedule ‘A’Part-IX(Ref prepriced schedule attached seperately) |
| 12 | Lump sum price worked out by the contractor for REFRIGERATION & AIR CONDITIONING WORKS as listed in Schedule ‘A’Part-X(Ref prepriced schedule attached seperately) |
| 13 | Lump sum price worked out by the contractor for FOOTBALL, VALLEY BALL, BADMINTON, KHO KHO, KABADDI AND BASKET BALL GROUNDS WORKS as listed in Schedule ‘A’Part-XI(Ref prepriced schedule attached seperately) |
| 14 | Lump sum price worked out by the contractor for BALA CONCEPT WORKS as listed in Schedule ‘A’Part-XII(Ref prepriced schedule attached seperately) |
| 15 | Lump sum price worked out by the contractor for DEMOLITION / DISMANTLINGWORKS as listed in Schedule ‘A’Part-XIII(Ref prepriced schedule attached seperately) |
| 16 | Lump sum price worked out by the contractor for EXCAVATION, EARTH WORK AND SITE DEVELOPMENT WORKSas listed in Schedule ‘A’ Part-XIV (Ref prepriced schedule attached seperately) |
| 17 | SCH \"A\" Pt - XV (MISCELLANEOUS ITEMS) |
| 18 | INTERNAL WATER SUPPLY WORKS NOTE:- For items of internal Electrifications notes given at the beginning of Sch ‘A’ Part-II ( INTERNAL WATER SUPPLY WORKS) shall also be applicable. |
| 19 | Supply and fix health faucet copper alloy (Chromium plated) of size 15mm bore dia complete all as specified and as directed |
| 20 | INTERNAL ELECTRIFICATION WORKS NOTE:- For items of INTERNAL ELECTRIFICATION WORKS notes given at the beginning of Sch ‘A’ Part-III ( INTERNAL ELECTRIFICATION WORKS) shall also be applicable. |
| 21 | M&L point wiring for lightpoint wiring complete with 1.5 Sq.mmm PVC insulation unsheathed muilt-starnded FRLSH copper conductor 1100 Volts grade draw through in and including 20 mm dia PVC conduit and conduit accessories, concealed in walls and terminated to and including provision of modular metal flush boxes (metal switch board of any type and size) with modular metal frame plate and white cover for housing switch, sockets, regulators etc, including 1.5 sqmm PVC insulated unsheathed multi-stranded FRLSH copper conducotor cable as earth continuity conductor and connecting to common earth dolly, complete all as specified and directed for the following points (Ser Item No 5.01 to 5.05) .NOTE;-The quoted rate is deemed to inclusive of cost of metal flush boxes, modular white cover plate. |
| 22 | One light point controlled by one way 6A modular switch. |
| 23 | One ceiling fan/exhuast fan point controlled by one way6A modular switch. |
| 24 | One bell point controlled by one modular 6Abell push switch on same board with other switches or independent board as specified by Eng-in-charge |
| 25 | One light point controlled by 6A, 2-way modularswitches |
| 26 | All as per Sl item No. 5.01 above, but with cable 2.5 sqmm for phase and neutral & 2.5 sqmm for earth continuity complete for 6/16 Amps socket point on independent board complete all as specified and directed |
| 27 | S&F LED tube light fitting batten type, 20 W, 230v , efficacy 120 Lumens per watt, colour temprature 6500 K (Cool White), power factor greater than 0.90, polycarbonate body , CRI 80, IP rating IP 20,THDv within 5% and THDi (8-10%)and integrated electronic drivercomplete with all accessories internally pre-wired and including connecting up with three core twisted flexible copper conductor cable of suitable size from ceiling roseall as specified and directed.Notes :- 1.The rate of three core twisted flexible copper conductor cable of suitable sizefor connectionis included in this item and nothing shall be paid extra on this account. 2. Warranty for replacement of each LEDLight fitting shall not be less than 05 yearsfrom the date of purchase. 3. Date of Purchase shall be marked on each fixture with permanent marker for redeeming warrenty benifits. |
| 28 | Supply & Fixing LED tube light fitting batten type. 10 W, 230v , efficacy 120 Lumens per watt, colour temprature 6500 K (Cool White), power factor greater than 0.90, polycarbonate body , CRI 80, IP rating IP 20, THDv within 5% and THDi (8-10%) complete with all accessories internally pre-wired and including connecting up with three core twisted flexible copper conductor cable with suitable size from ceiling rose all as specified and directed. Notes :- 1.The rate of three core twisted flexible copper conductor cable of suitable sizefor connectionis included in this item and nothing shall be paid extra on this account. 2. Warranty for replacement of each LEDLight fitting shall not be less than 05 yearsfrom the date of purchase. 3. Date of Purchase shall be marked on each fixture with permanent marker for redeeming warrenty benifits. |
| 29 | Supply and fix recessed mounter 2’ x 2’ LED luminaire, 30W LED 6500K with extruded aluminium heat sink, control gear, poly carbonate extruded diffuser & integrated electronic driver, 230 V etc complete with all accessories internally pre-wired and including connecting up with three core sheathed copper cable 1.5 sqmm complete all as specified and directed. |
| 30 | Supply and fix surface mounted square shaped luminaire, 32W LED 6500K with low height CRCA housing and high transmitivity, control gear & integrated electronic driver 230V etc complete with all accessories internally pre-wired and including connecting up with three core sheathed copper cable 1.5 sqmm complete all as specified and directed. |
| 31 | S & F LED Security light fitting 25 Watt, luman efficacy of LED 140 lm/W, PF> 0.95, THD < 10%, colour temprature 6500K, CRI > 70, system lumen not less then 2600 Lm, made up of pressure die cast aluminium housing with high efficiency LED as lighting source and lens with toughed glass having bottom separate driver compartment with IP 66 Protection and Impact resistant of IK 07 etc and all accessories previewed complete including mounting bracket of GI Pipe 40 mm inner dia light grade of required length and shape incl bending, forging or welding etc and suitable bolts and nuts with washers, including connecting with PVC insulated multi stranded copper flexible cable of size 0.5 sq mm three core from ceiling rose to fitting all as specified an directed. |
| 32 | S & F LED Security light fitting 40 Watt, luman efficacy of LED 140 lm/W, PF> 0.95, THD < 10%, colour temprature 6500K, CRI > 70, system lumen not less then 2600 Lm, made up of pressure die cast aluminium housing with high efficiency LED as lighting source and lens with toughed glass having bottom separate driver compartment with IP 66 Protection and Impact resistant of IK 07 etc and all accessories previewed complete including mounting bracket of GI Pipe 40 mm inner dia light grade of required length and shape incl bending, forging or welding etc and suitable bolts and nuts with washers, including connecting with PVC insulated multi stranded copper flexible cable of size 0.5 sq mm three core from ceiling rose to fitting all as specified an directed. |
| 33 | Supply and fix TPN DB-VTPN DPX³ 160 MCCB distribution board double door type (for incoming MCCB & outgoing MCBs) TPN 6 way, as per IEC 61439-3, suitable for flush mounting and surface mounting with 250A copper bus bar for each phase with 2 neutral bar, 2 earth bar and cable ties for cable management, fully insulated bus bar &shrounded neutral bars, improved pan assembly for ease of installation, pre-fitted masking sheet, reversible Door for IP 54 DB’s with provision for DPX³ 160 MCCB as incomer and SP/TP MCB’s as outgoing complete all as specified and as directed. |
| 34 | Supply ad fix MCCB 160 Amps, 25KA 4 pole with thermal and magnetic release complete all as specified and as directed. |
| 35 | S&F MCB TPN 40-63 Amps ‘C’ series, breaking capacity 10 KA, ‘C’ curve 240 volts, 50 Hz including necessary incoming and outgoing electric connection with suitable size of copper lugs etc complete all as specified and directed. |
| 36 | S&F MCB SPN, 30 Amps, ‘C’ series breaking capacity 10 KA, ‘C’ curve 240 volts, 50 Hz including necessary incoming and outgoing electric connection with suitable size of copper lugs etc.complete all as specified and directed. |
| 37 | S&F MCB SP, 6 Amps to 32 Amps, ‘C’ series, breaking capacity 10 KA, ‘C’ curve 240 volts, 50 Hz including necessary incoming and outgoing electric connection with suitable size of copper lugs etc complete all as specified and directed. |
| 38 | M&L for MCB blanking plate complete all as specified and directed. |
| 39 | Supply and fix 3 phase energy meter digital type 400 Amps capacity including suitable CT/PT complete with CTs polycarbonate transparent box with sealing arrangement complete all as specified and directed. |
| 40 | EXTERNAL WATER SUPPLY WORKS NOTE:- For items of EXTERNAL WATER SUPPLY WORKS notes given at the beginning of Sch ‘A’ Part-IV (EXTERNAL WATER SUPPLY WORKS) shall also be applicable. |
| 41 | Cutting of existing 150mm bore line and inserting MS tee of 150 x 150x 100mm including excavation, returning, filling, including run lead joint of suitable size complete all as specified and directed. |
| 42 | Supply, lay, connecting and testing ductile iron pipes single socketed and spigoted as per IS-8329:2002 cement mortar lining with portland slag cement as per IS-455:1989, metallic zinc coating as per IS-8329, finishing layer bituminous layer coatincluding specials, class”K-9”, 100 mm bore including tyton joints and accessories of jointing materials complete all as specified and directed. |
| 43 | M&L construction of 200mm thick PCC solid block wall masonry valve chamber 900mm x 900m x 860mm built in CM 1:6 with 150mm thick PCC 1:3:6 type C2 as in foundation, PCC 1:2:4 type B-1 as in coping 50mm thick finished even and smooth, rendering 10mm thick in cement mortar (1:6), finished fair and even externally including excavation earthwork in any strata, 3mm thick MS sheet cover fixed on angle iron frame embedded in PCC coping with locking arrangement and mild steel hold fast for manhole covers and painting to steel surface with two coats of black bituminous paint over one coat of red oxide primer complete all as specified and directed.(Refer Drawing No. TD/AR/73) |
| 44 | M&L for ductile iron pipe special for spigot socketed K-12 shall to confirm IS-9523 all fittings provided with internal mortar lining coating metallic zinc coatingof any size and any type such as tees, bends, collars, reducers, tappers, blank plate, MJ adopters etc suitable for 50mm to 100 mm bore pipes complete all as specified and directed. |
| 45 | EXTERNAL ELETRIC SUPPLY AND DG SET WORKS NOTE:- For items of EXTERNAL ELECTRIC SUPPLY notes given at the beginning of Sch ‘A’ Part-V (EXTERNAL ELETRIC SUPPLY) shall also be applicable. |
| 46 | Supply and erect, fix 2 pole structure on 11 meter steel tubular pole consisting of anti climbing device & cross arms including incoming, out going jumpers, insulators, GOD 1 set, drop out fuse 1 set, lightening arresters 1 set etc including painting with one coat of primer and two coats of synthetic enamel paint on steel surfaces complete all as specified and directed. NOTE Excavation and PCC foundation will be measured and paid in relevant schedule \"A\". |
| 47 | Supply, installation, testing and commissioning of step down transformer out door type suitable for plinth mounting complete with standard accessories/fittings suitable for HT 11KV 3 Phase and LT 433 volts 3 phase 4 wire , Dyn-11, copper wound, with off load tap changer having voltage variation of ±7.5% in step of 2.5 % continuous rating of capacity 250 KVA with temperature rise shall not exceed 45° C for transformer winding and 40° C for top oil complete conforming to IS 1180 (Part 1) : 2014and other relevent IS code Energy Efficiency Level - 2for transformer including necessary suitable size PCC platform and comprising of following fittings :-(a) Two earthing terminals for body earthing and two additional for neutral brought out on a bushing.(b) Lifting lugs/hooks . (c) Rating and terminal marking plate.(d) Silica gel breather .(e) Drain - cum - sampling valve (3/4)\" nominal thread with plug (f)Thermometer pocket with dial type thermometer.(g) Oil filling inlet pipe with plug.(h) Conservator with oil level gauge.(j) First fill of oil up to appropriate level as recommended by manufacturer with fresh new oil. (k) Type of connection arrangement : MS cable termination box on LT side and open bushing on HT side.NOTE :- (i)Plinthstone masonry platform as per manufacturer recommendations complete with standard fittings conforming to IS-1180 energy efficient and with ECBC Closset or latest IS complete all as specified and as directed. (Note:-Stone masonary platform will be measured and paid separately)(ii)Precommisioning test shall be referred form PS(III)Factory inspection shall be referred from Schedule A Notes. |
| 48 | Supply, install, testing and commissioning factory made floor mounted compartmentalised cubical panel board outdoor type made out of self supported 3.15 mm minimum thickness for outer sheet and 2mm minimum for inner sheets CRCA/Polycarbonate sheet conforming to IS-8623 IP 43 protection totally enclosed with necessary ventilation, weather, dust and vermin proof with front and rear opening and locking arrangements, 433 Volts, 3 phase, 4 wire 50 Hz having aluminium bus bar of capacity 600 Amps 4 Nos with bus bar chamber including PCC foundation, powder coating to all steel surfaces complete all as specified and directed with the following provisions :-Incoming(a) MCCB 400 Amps, 4 pole, 415 Volts, 36 KA with thermal magnetic release (manual fixed type) 01 No (b) Multifunction meter MFM 4400 LED meter Cl I.Accuracy class 1.0, 0.5 input voltage measurement range 50-550 VAC Aux supply 90-300 VAC/DC CT secondary site selectable 1A/5A flush mounting 96 x 96 mm CT/PT site programmable, Parameteres V, A, F, PF, KW KWh, KVA KVAh, old Wh on hours. (c) Gen next universal LED indicator, RYB of ɸ 22.5mm, Cat No EGO100L.(Contd..) |
| 49 | Outgoing(a) MCCB 320 Amps 3 pole, 415V with breaking capacity 25 KA-01 No.(b) MCCB 200 Amps, 3 pole, 415V, adjustable type with breaking capacity 25KA – 02 (c) MCB 30Amps, double pole (TPN) conforms to IS/IEC 60898 and IEC 60947 -2 and havingbreaking capacity of 10 KA throughout the range - 01 No.(d) MCB 6 Amps, single pole (SP) conforms to IS/IEC 60898 and IEC 60947-2 and having breaking capacity of 10 KA throughout the range – 02 Nos. (e) Astro time switch 2 module – 01 No, 3 pole power contactor 30 Amps with by passing switch wiring. |
| 50 | Supply, install, testing and commissioning factory made floor mounted compartmentalized cubical panel board outdoor type made out of self supported 3mm minimum thickness for outer sheet and 2mm minimum for inner sheets, CRCA/polycarbonate sheet conforming to IS-8623 IP 43 protection totally enclosed with necessary ventilation, weather, dust and vermin proof with front and rear opening and locking arrangement, 433Volts, 3 phase, 4 wire 50 Hz having aluminium bus bar of capacity 600 amps, 4 Nos with bus bar chamber including foundation, powder coating and all steel srufaces complete all as specified and directed including for the following provisions :- Incoming :(a) MCCB 320 Amps, 3 pole, 415Volts with breaking capacity 36KA-01 No.(b) Basic multifunction meter MFM 4400 LED meter Cl I, accuracy class 1.0, 0.5 input voltage, measurement range 50-550 VAC, Aux supply 90-300 VAC/DC CT secondary site selectable 1A/5A, flush mounting 96 x 96 mm, CT/PT site programmable Parameteres V, A, F, PF, KW KWh, KVA KVAh, old Wh on hours.(c) Gen next universal LED indicator, RYB of ɸ 22.5mm.Outgoing:(a) MCCB 160 Amps, 3 pole, 415Volts, adjustable type with breaking capacity 25KA – 03 Nos (2W+1S). (b) MCCB 40 Amps, 3 pole, 415Volts, fixed type with breaking capacity 16KA – 02 Nos (1W+1S). |
| 51 | S & F LED Street light fitting 45 Watt, with brackets luman efficacy of LED 140 lm/W, PF> 0.95, THD < 10%, colour temprature 6500K, CRI > 70, system lumen not less then 2600 Lm, made up of pressure die cast aluminium housing with high efficiency LED as lighting source and lens with toughed glass having bottom separate driver compartment with IP 66 Protection and Impact resistant of IK 07 etc and all accessories previewed complete including mounting bracket of GI Pipe 40 mm inner dia light grade of required length and shape incl bending, forging or welding etc and suitable bolts and nuts with washers, including connecting with PVC insulated multi stranded copper flexible cable of size 0.5 sq mm three core from ceiling rose to fitting all as specified an directed. |
| 52 | Supply and fixing thermoplastic polycarbonate street light pole cable junction boxes IP 66 “halogen free and weather proof” for outdoor installation hinged door with locking arrangement MS clamps for fixing on pole 4 way connectors 2 Nos MCB SP 10A-01 No, cable glands 2 Nos with metric knockouts for cable entry of size 167 x 125 x 82 mm complete all as specified and directed. |
| 53 | S&F cable path indicator for HT cable made out of moulded cast iron of 100mm dia & 6 mm thick engraved with “HT 11000 volts” welded to MS angle 50x50x6mm, 1.25 mtr long and base plate of size 200mmx200mmx6mm duly welded to equal angles 0.25 m embedded in PCC block (1:3:6) type C-2 of size 30x30x30cm and 1 mtr above ground level including painting with two coats of brown colour synthetic enamel paint over one coat of red oxide primer includingnecessary earth work, RFR and removal of surface soil complete all as specified and directed. |
| 54 | M& for platform of size 3 mtr x 3 mtr x 1 mtr height for outdoor transformer 250 KVA usingPCC (1:4:8) foundation, type D2 (40mmgraded aggregate) upto 0.2 mtr.RCC (design mix) M-25 (using 20mm graded aggregate) of 0.2 mtr thick at bottom, sides and top with 10mm dia TMT bars and PCC 1:3:6 type C2 mass concrete including angle iron frame using 55x55x10mm thick angle iron frame grouted in PCC including nuts and bolts for installation of transformer complete all as specified and directed. |
| 55 | M&L for chain link fencing around transformer of fencing plan size 10 mtr in length x 10 mtr in width including PCC 1:4:8 type D2 (using 40mm grade aggregate) as in foundation, DPC with M-25 design mix, brick wall upto height 0.9 mtr above DPC and angle iron of size 55x55x6mm 4.5 metre total length with base plate fixed in foundation to secure chain linkfencing size of opening not more than 75mmx75mm and wire not less than 3mm dia of size 2.25 mtr high fixed with nut and bolts or welded with flat iron of size 50mmx4mm including two coats of aluminium paint over a coat of red oxide primer on steel srufaces including iron gate, locking arrangements,three coats of white wash to plastered surfaces complete all as specified and directed. |
| 56 | Supply and install switch dis connectorfuse units in sheet steel enclosure type FN (TPN) S-D-F suitable for DIN fuse-link, current rating : 160 Amp including HRC fuses conforms to IEC 60947-3, IS/IEC 60947-3 door interlock & padlock facility, type : FN 160 TPN complete all as specified and directed. |
| 57 | S&F automatic power factor correction (APFC) panel for 3 phase 415 V & 50Hz system of capacity 70 KVARincomingMCCBtotally enclosed outdoor type factory made in minimum four steps 5/10/20 or asper OEM nearer steps and capacity withrelaycompletewith internalwiring and contractors complete allas specified and directed. |
| 58 | REFRIGERATION & AIR CONDITIONING WORKSNOTE:- For items of REFRIGERATION & AIR CONDITIONING WORKS notes given at the beginning of SCHEDULE \"A\" PART -X (REFRIGERATION & AIR CONDITIONING WORKS) shall also be applicable. |
| 59 | S&F Voltage stabilizer for automatic cut off and cut in operation, single phase naturally air cooled indoor type and designed for input variation between 170 volts to 250 volts with output voltage stabilizer at 230 voltage with accuracy of ± 2.5% and of capacity 2 KVA complete all as specified and directed. |
| 60 | S&F Voltage stabilizer for automatic cut off and cut in operation, single phase naturally air cooled indoor type and designed for input variation between 170 volts to 250 volts with output voltage stabilizer at 230 voltage with accuracy of ± 2.5% and of capacity 4 KVA complete all as specified and directed. |
| 61 | FOOTBALL, VALLEY BALL, BADMINTON, KHO KHO, KABADDI AND BASKET BALL GROUNDS WORKSNOTE:-(a)For items of FOOTBALL, VALLEY BALL, BADMINTON, KHO KHO, KABADDI AND BASKET BALL GROUNDS WORKS notes given at the beginning of SCHEDULE \"A\"PART -XI (FOOTBALL, VALLEY BALL, BADMINTON, KHO KHO, KABADDI AND BASKET BALL GROUNDS WORKS) shall also be applicable.(b)Excavation and earth work & site development etc required for scope covered under provisional lump sum shall be measured and paid under relevant items of sch ‘A’ part XIV, i.e. Excavation,Earth work and Site developement. |
| 62 | Supply, fabricate and fixing adjustable type basket ball pole - 02 Nos.with MS 100mm x 100 mm (3.5 mm thick of height adjustment 10 ft to 7 ft with acrylic board of 1/2\" 1500 mm x 900 mm, MS base plate300 mm x 300 mm including 2 coats of synthetic enamel (powder coated) over a coat of red oxide primer on all steel surfaces including net as per manufacturer\"s instruction complete all as specified and directed. |
| 63 | M&L for good earth (14:4:2) consisting of red soil-14 parts, sand-4 parts and organic manure 2 parts mixed well and moistured including spreading, levelling, watering and well ramming all as specified and directed for top layer playgrounds so as to provided a smooth surface and turtle back crown slope suitable for playgrounds complete all as specified and directed. |
| 64 | Supply and application of all weather synthetic cushion (8 layers) surface system for outdoor basketball court consisting of : cleaning of the base surface, application of acrylic primer coat, one layer of resurfacer (sealer /levelling coat), one layer of heavy cushion system, two layers of fine cushion system followed by two acrylic base coat colours and one top coat finish colour including game line marking to a total thickness of approx 3 mm all as per FIBA international standards and as per manufacturer\"s instructions |
| 65 | M&L for special painting of pictures like national heroes, animals, birds, cartoons, political maps of country or any works of similar nature not exceeding 1 Sqm each thick with synthetic enamel paint complete all as specified and directed. |
| 66 | M&L for special painting of pictures like national heroes, animals, birds, cartoons, political maps of country or any works of similar nature exceeding 1 Sqm but not exceeding 2 Sqmthick with synthetic enamel paint complete all as specified and directed. |
| 67 | M&L for special painting of pictures line Natinal heroes, animals, birds, cartoons, political maps of country or any works of similar nature exceeding 2 Sqm but not exceeding 4 Sqmthick with synthetic enamel paint complete all as specified and directed. |
| 68 | DEMOLITION / DISMANTLINGWORKS NOTE:- For items of DEMOLITION / DISMANTLINGWORKSnotes given at the beginning of SCHEDULE \"A\" PART -XIII (DEMOLITION / DISMANTLINGWORKS ) shall also be applicable. |
| 69 | Taking down sheet metal box/DB of any size and capacity with MCB SP/SPN/TPN from any height complete all as specified and directed. |
| 70 | Taking down carefully copper/aluminium sub main point wiring of any size and type, any height complete all as specified and directed. |
| 71 | Taking down ceiling fan of any size and type, any height complete all as specified and directed. |
| 72 | Taking down exhaust fan of any size and type, any height complete. |
| 73 | Taking down/dismantling of LT feeder pillar box complete all as specified and directed. |
| 74 | BALA CONCEPT WORKSNOTE:- For items of BALA CONCEPT WORKSnotes given at the beginning of SCHEDULE \"A\" PART -XII (BALA CONCEPT WORKS ) shall also be applicable. |
| 75 | M&L for painting geometric shape like traingular, square, circular or similar etc not exceeding 1 sqm each on newly prepared stone/concrete/asbestos cement/plaster surfaces with two coat of synthetic enamel paint coat over priming paints plastered surface complete all as specified and directed. |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender