| 1 | Disconnecting and dismantling carefully the existing inlet,outlet,wash out and over flow pipes from existing PS tanks and making by pass arrangement to continue existing water supply by using GI tubing of required sizes and taking out the said arrangement after completing the work all as directed. (Note : cost of by pass arrangement shall deemed to be included in quoted rate) |
| 2 | M/L for cleaning of PS storagetank by draining out water, removing of mud and sediments accumulated in bottom of the tank, washing and drying upincluding clening/washing the bottom/wall surface by using the clening agent and scraping with wire/steel brush carefully and removing spoils to a distance not exceeding 50m all as specified and directed.of capacity 10000 to 12800 Glns. |
| 3 | All as per item No -2 above but capacity20000 Glns |
| 4 | All as per item No -2 above but capacity 25000 Glns |
| 5 | All as per item No -2 above but capacity 30000 Glns |
| 6 | M/L for cleaning of RCC Over head/above GLstoragetank by draining out water, removing of mud and sediments accumulated in bottom of the tank, washing and drying upincluding clening/washing the bottom/wall surface by using the clening agent and scraping with wire/steel brush carefully and removing spoils to a distance not exceeding 50mall as directed of capacity 3300 to 50000 Glns. |
| 7 | Dismantling carefully MS sheet of any size and thickness from the cover of existing PS Tank including unbolting nuts bolts and washer where ever required and shifting the same distance not exceeding 3 km complete all as specified and directed. |
| 8 | Dismantling carefully PS plate of any size and thickness from theexisting PS Tank including unbolting nuts bolts and washer and shifting the same distance not exceeding 3 km complete all as specified and directed. |
| 9 | Dismantling carefully MS structural steel of any section from existing PS tank by unboltingnuts bolts or cutting where ever required and shifting the same distance not exceeding 3 km complete all as specified and directed. |
| 10 | Fixing only old serviceable PS plate of any size and any thickness for side or bottom plate of PS tank, fixing with new or old serviceable nuts, bolts and all new jointing materials such as lead wool gasket, black non toxic putty etc complete all as specified and directed. (All new nuts and bolts and washer shall be measured and paid seperately here-in-after as supply only). |
| 11 | Supply and fix PS plate of size 1.25m x 1.25m x 6 mm thick for wall/ bottom of tank pre fabricated, factory made including drilling holes, fixing with new nuts, bolts and washers and all new jointing materials such as lead wool gasket black non toxic putty etc complete all as specified and directed. |
| 12 | Fixing only old serviceable MS sheet joint as incover of PS tank including cutting, drilling hole etc fixing with new or old serviceablenuts, bolts and washers etc complete all as specified and directed, (All new nuts and bolts and washer shall be measured and paid seperately here-in-after as supply only). |
| 13 | Supply and fix 3.15 mm thick MS sheet joint as incover of PS tank including cutting, drilling hole etc fixing with new or old serviceablenuts, bolts and washers etc complete all as specified and directed, (All new nuts and bolts and washer shall be measured and paid seperately here-in-after as supply only). |
| 14 | Fixing only old serviceable structural steel including cutting, drilling hole etc fixing with new or old serviceablenuts, bolts and washerscomplete all as specified and directed. (Note :All new nuts and bolts and washer shall be measured and paid seperately here-in-after as supply only). |
| 15 | Supply and fix MS angle, MS flat or MS tee section of grade Fe-410-W cut to required size and shape for bracing, supports and clamps including welding drilling holes,fixing with new or old serviceablenuts, bolts and washerscomplete all as specified and directed. (Note :All new nuts and bolts and washer shall be measured and paid seperately here-in-after as supply only). |
| 16 | Supply and fix 5 mm to 10 mm dia of neck MS screw bolt (Machine made) with Hexagonal head at one end and screwed the other end to be fitted with two number of washers and one hexagonal nuts for required size of bolts (n.exc 5 cm long) complete all as specified and directed. |
| 17 | Taking down cement plaster from brick or concrete surfaces of any description including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed. |
| 18 | Materialand labour for rendering 10 mm thick cement plaster in cement mortar (1:4) on old face of brick work or concrete surface on walls complete all as specified and directed. |
| 19 | Material and labour for preperation of new or old steel surface exceeding 10cm width or girth, including cleaning, washing and applying two coats of black bituminous paint anticorossive (suitable for drinking purpose) over a coat of red oxide primer on internal sufaces of PS tank complete all as specified and directed. |
| 20 | Material and labour for preperation of new or old steel surfaces externally exceeding 10cm width or girth, OG green synthetic enamel paint over a coat of red oxide primer on external sufaces of PS tank complete all as specified and directed. |
| 21 | Material and labour for writing letter or figures (Block, Roman, Italic or Indian) of size not exceeding 30 cm height with synthetic enamel paint all as specified and directed. |
| 22 | M&L for cleaning of sedimentation tank with Gravity feed filter bed of of size 15x12x3.5 mafter draining out complete, clean the surface, bottom, wall, chamber etcby the help of brushes chemical/Acid and taking out all silt, dirt, etc complete all as specified and directed. |
| 23 | S & F in replacementincl leakage testing of galvanised steel water tubing medium grade 150 mm dia bore with all fittings such as bends, flange,elbow,reducer etc,laying/connecting pipe to PStank through connectors as required at site, laid under floor / trenches all as specified & directed. |
| 24 | Description all as per item No 23 of above but of size 100 mm dia all as specified & directed. |
| 25 | Description all as per item No 23 of above but of size 80 mm dia all as specified & directed. |
| 26 | Taking out old unserviceable Gun metal gate valve in different sizes 20mm, 25mm, 40mm and 50 mm with iron wheel head complete all as specified and directed. |
| 27 | Supply, installation, commissioning and testing of 25 mm bore gun metal gate valve ISI marked class I with iron wheel head screwed both ends for iron pipe at directed at site complete all as specified and directed. |
| 28 | Supply, installation, commissioning and testing of 40 mm bore gun metal gate valve ISI marked class I with iron wheel head screwed both ends for iron pipe at directed at site complete all as specified and directed. |
| 29 | Supply, installation, commissioning and testing of 50 mm bore gun metal gate valve ISI marked class I with iron wheel head screwed both ends for iron pipe at directed at site complete all as specified and directed. |
| 30 | Taking out old unserviceable Cast iron Sluicevalve in different sizes 150mm, 100mm and80mm with iron wheel head complete all as specified and directed. |
| 31 | Supply and Fixingfor cast iron sluice valve in repair, class PN 1.6 long body type, 150 mm bore with brass spindle, both ends flanged with holes, ISI Marked (IS-14846-2000) provision of carbon steel nuts, bolts & washers, rubber gasket etc, with CI wheel, fixed to CI/GIwater mains complete all as specified and as directed. |
| 32 | Supply and Fixingfor cast iron sluice valve in repair, class PN 1.6 long body type, 100 mm bore with brass spindle, both ends flanged with holes, ISI Marked (IS-14846-2000) provision of carbon steel nuts, bolts & washers, rubber gasket etc, with CI wheel, fixed to CI/GIwater mains complete all as specified and as directed. |
| 33 | Supply and Fixingfor cast iron sluice valve in repair, class PN 1.6 long body type, 80 mm bore with brass spindle, both ends flanged with holes, ISI Marked (IS-14846-2000) provision of carbon steel nuts, bolts & washers, rubber gasket etc, with CI wheel, fixed to CI/GIwater mains complete all as specified and as directed. |
| 34 | M&L for supply and fixing in replacement of flanges provided on GI pipes of 150/100/80/50 mm dia including threading of flanges on GI pipes new/old including taking down of old flanges, inclding applying sealing compound/Rubber Gasket complete all as specified & directed. |
| 35 | M&L for structural MS frame work half round or other stock section including securing posts and stuts in fencing, frame work for pump house/gates of installations, base frame for equipments including securing bolts, posts and sturts in fencing including cutting and makeing shapes as desired, drilling holes, notching for wire cut to size and made to the exisitng shape suitable for fixing MS chequred duct covers / door panels, including nuts, bolts and washers, welding / bracing works, bendingcold or hot drilling holes for bolts in any shapeetc flat iron fillets (for securing wire mesh etc)all necessary drilling, bolting or riveting etc and similar work confirming to Fe-290 Gde E-165 including onecoat of primer and two coats of synthetic enamel paint to the entire steel surfaces all as specified and directed. |
| 36 | M & L for repair,rectifying andaresting the water leakage in already laid CI pipe line of dia150/100/80 mm dia from water sources collectiing chamber to water supply pump house storage tank/PS Tank including necessary excavation and earth work, bailing out stagnated /muddy water and providing CID joint /Detachable Joint /lead wool etc complete to stop the leakageall as specified and directed by Eng-in-Charge.Note for serial no. 36 to 39: -(i) Contractor will depute Labour/Pipe Fitter and other required equipments such as JCB etc to attend the leakage /complaint on daily basis as per complaint trace out and no extra payment made out on this account and directed by Engineer-in-charge. (ii) Complete site for attend the leakage can notbe handed over to contractor ,Site of leakage only handed over the contractor on site requirement basis. (iii) Contractor/Supervisor will collect complaint of leakage from concern JE as daily basis and will complete same day.(iv) If leakage again found during the contract period at same location contractor will repair it again and no extra payment will bemade on this account.(v) Contractor will provide equipments like JCB/tractor etc on his own arrangement for rectifying the complaint as per site requirement and no other payment will be made for the same. |
| 37 | All as per serial item No- 36 here-in-before but DI/GI pipe of size 150 mm dia -do-. |
| 38 | All as per serial item No- 36 here-in-before but DI/GI pipe of size 100 mm dia -do-. |
| 39 | All as per serial item No- 36 here-in-before but DI/GI pipe of size 80 mm dia -do |
| 40 | M & L for repair/replacementforleakage of GI pipe line 50 mm dia incl bailing out of stagnated/muddy watertill restore the water supply with replacement of necessaryfittings such as elbows ,nipples union,reducersetc if required of GIpipe line upto 1 mtr as per site requirementincluding earth work such as excavation returning removal etc andall as specified and directed by Eng-in-Charge. Note for serial no. 40 to 42 -(i) Contractor will depute Labour/Pipe Fitter and other required equipments such as JCB etc to attend the leakage /complaint on daily basis as per complaint trace out and no extra payment made out on this account and directed by Engineer-in-charge.(ii) Complete site for attend the leakage can notbe handed over to contractor ,Site of leakage only handed over the contractor on site requirement basis. (iii) Contractor/Supervisor will collect complaint of leakage from concern JE as daily basis and will complete same day. (iv) If leakage again found during the contract period at same location contractor will repair it again and no paymentwill made on this account.(v) Contractor will provide equipments like JCB/tractor etc on his own arrangement for rectifying the complaint as per site requirement and no other payment will be made for the same. |
| 41 | All as per serial item No-40 here-in-before but GI pipe of size 40 mm dia -do-. |
| 42 | All as per serial item No-40 here-in-before but GI pipe of size 25 mm dia -do-. |
| 43 | Dismentling carefully the existing valve pit, removing ruined material from site where directed complete all as specified and directed. |
| 44 | Materialand labour for construction of Solid PCC Block masonary valve pit of size (900mm x 900mm x 1500mm)(internal dimensions) 200 mm thick precast cement concrete solid block masonary wall in cement mortar (1:4) over 100 MM thick PCC 1:4:8 type D2 (Using 40 mm graded crushed stone aggregate) as in foundation, 15 mm thick rendering an cement mortar (1:6) internally, externally upto 15 cm below ground level provision of valve pit covermade out of 3 mm thick MS sheet welded with ISA 40mm x 40mm x 5 mm thick angle iron frame all round including provision of hinges, lifting handles, and locking arrangement fixed on top of valve pit by means of hold fast 150 mm long, embedded in PCC 1:2:4 type B1 (Block size 230 mm x 200 mm x 100 mm) including applying two coats of synthetic enemel paint over a coat of red oxide zinc chrome primer and necessary earth work in hard/dense soil complete all as specified and as directed. |
| 45 | Materialand labour for construction of Solid PCC Block masonary valve pit of size (1500mm x1500mm x 1500mm)(internal dimensions) 200 mm thick precast cement concrete solid block masonary wall in cement mortar (1:4) over 100 MM thick PCC 1:4:8 type D2 (Using 40 mm graded crushed stone aggregate) as in foundation, 15 mm thick rendering an cement mortar (1:6) internally, externally upto 15 cm below ground level provision of valve pit covermade out of 3 mm thick MS sheet welded with ISA 40mm x 40mm x 5 mm thick angle iron frame all round including provision of hinges, lifting handles, and locking arrangement fixed on top of valve pit by means of hold fast 150 mm long, embedded in PCC 1:2:4 type B1 (Block size 230 mm x 200 mm x 100 mm) including applying two coats of synthetic enemel paint over a coat of red oxide zinc chrome primer and necessary earth work in hard/dense soil complete all as specified and as directed. |
| 46 | Taking down carefully existing filter media(sand/gravel) from the filtration plany vaeesl type at water point no 2 & 4 and removing the same not exceeding 50 mtr and and depositing where directed at a level not exceeding 1.5 mtr above the starting point all as specified and directed. |
| 47 | Supply and laying filtration plant gravel round shape of size 6.5 to 12.5 mm as per the sampel all as specified and directed. |
| 48 | Supply and laying Barakar river sand in filtration plant of effective size of 0.5 mm to 1.0 mm as per the sample complete all as specifed and directed. |
| 49 | M&L for 100 mm thickPCC 1:2:4 type B-2 using 40 mm graded aggregate as in floor, finished the surface even & smooth without using extra cement complete all as specified and as directed by Engineer-in-Charge. |
| 50 | Material & Labour for machine pressed precast concrete interlocking paver block of approved shape and size of 80 mm thickness, with minimum compressive strength of 40 N / Sqmm (M-40 grade), without correction factor for chamfering, made in rubber moulds with 0.50 mm thick scratch proof lacquer coating on top surface, with white cement and pigment laid over and including 20 mm thick (compacted thickness) sand screed bed complete |
| 51 | M & L for 75 mm thick plain cement concrete 1:3:6 type C2 (using 40 mm graded stone aggregate) as in plinth protection, surfaces finished even and smooth without using extra cement all complete all as directed by Engineer -in-charge. |
| 52 | M & L for Chequered cement concrete tiles 20cm x 20cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors complet all as specifedand directed. |
| 53 | M&L for Moorum / red bajri filling in floors or pavings, laid in layers n.exc 100 cm thick, spread, levelled and rammed including watering all as specified and as directed by Engineer-in-Charge. |
| 54 | M&L for hardcore of broken stone boulder of gauge n exc 63 mm, deposited, spread and levelled in layers n exc 15 cm thick watered and rammed to true surface. |
| 55 | M & L Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete |
| 56 | Testing of water sample from different locations PS Tank , over head RCC tankfor potability by chemical analysis as well as bacteriological potability from Govt Laboratory and submission of the report complete all as specifcied and as directed. |
| 57 | Supply only chlorine test kit with coloured ample complete with all testing fitments and 100 ml OT solution in rexine finish wooden box all as per sample complete all as specified. |
| 58 | Supply only OT solution in 200 ml bottle complete all as specified. |
| 59 | Supply, fixing, testing & commissioning of dosing system complete set including dosing pump of model CDS 1015high pressure single head gear motorised adjustable dosing pump with accessories including lead tubing, connecting nuts, injection check valve, clay weight, ferrules, 170 ltrs PE/FRP preparation tank , 100 ltr dozing tank with PE/FREP lid and level gauge alongwith agitator with shaft & blade in plastic, mounted on tank also including complete connection of water for dosing system and connecting of output of dosing system to supply line, necessary switch and sockets for providing power supply to dosing system as per site requirement all as specified and directed. |
| 60 | M&L for periodical Servicing & maintenance of Altoch dosingplant by providing specialist trades men including replacement of valve, rubber washer, check nut, connecting nuts, adapterand cleaning and servicingof solution tank and connected items to ensure that perfect serviceability of the plant and obtain required dosage to the entire satisfaction of theEngr In charge as directed.Note:-(i) periodical Servicing & maintenance shall be carried out for 4 times in a year & shall be measured as one Job for payment.(ii) Major spare part if found unserviceable shall be measured & paid separately as supply only. |
| 61 | Supply and fix in repair Propylene rigid shaft, of32 mm dia, 500 mm long with two bladed pitched blade turbine, impeller, blade fixed to shaft, suitable for Altoch dosingplant complete, all as specified and directed by Engr In charge. Make:- DECLIBAC Cat No - 042009B, or equivalent make approved by the GE |
| 62 | Supply and fix in repair PE /FRP dozing tank of capacity 100 litres with lid containing port hole for pouring chlorination chemical and water including provision for mounting arrangement for motor & dosing pump, solution level indication Gauge suitable for Altoch dosingplant complete complete all as specified and directed by Engr In charge. Make:- DECLIBACor equivalent make approved by the GE |
| 63 | Supply and fix in repair Decrin dosing pump, high pressure single head gear motor adjustable dosing pump with accessories complete including lead tubing, connecting Nuts, injection check valve, clay weight and ferrules, suitable for Altoch dosingplant complete all as specified and directed by Engr In charge. Make- Declibac Model No - 96NGQ51 or equivalent make approved by the GE |
| 64 | S&F in repair Teflon pipe 9.5 mm dia with PVC nut and nipple 5 Metre long for gravity feed type chloronome plant all as specified and directed by Engr In charge.Make - Aqua / Swetaor equivalent make approved by the GE |
| 65 | Supply only Calcium Hypochlorite 65% to 70% chlorine content in packed with 45 Kg each drum (calcium based granular disinfectant for water treatment much more stable than chlorine gas and stronger than bleaching powder & sodium hypochlorite complete all as specified and directed.Make : Aquafit or equivalent as approved by NMPT committee of E-in-C\"s Branch.Note :-1.The calcium hypochoride will be issued in sealed containers of capacity 30/45/50 KG, cost of same shall be included in quoted rate. |
| 66 | Supply only non Ferric Alum crystal type complete all as specified conforming to BIS 260 - 2001 (2nd Revision) Make :Assent Chemicals Ltd or equivalent as approved by GE. |
| 67 | Supply only bleaching powder of grade conforming to IS-1065-1989 (2nd Revision) minimum markable chlorine 33.5% by mass packed in HDPE bag of 25Kg capacity ISI marked complete all as specified Make: DCM/Modior equivalent E -in -Cs approved manufacture. Note : (a)The contractor shall produce Manufacturer\"s \"Certificate of Compliance\" indicating date of manufacture in original alongwith every Consignment of supply.(b)Test certificate from Govt approved Test Laboratory shall accompany with Every Consignment of supply to ensure that the Materials supplied are in with conformity with the relevants. |