| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil. |
| 2 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : (a) 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) |
| 3 | (b) 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) |
| 4 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 5 | 12 mm Cement plaster 1:3 (1 cement: 3 coarse sand) |
| 6 | 15 mm cement plaster 1:3 (1 cement: 3 coarse sand) |
| 7 | Galvanised steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in positionand applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. G.I. Tube |
| 8 | P/f mulitiwall polycarbonate sheet 10mm thickness of approved by enigneer-in-charge, the sheet shall be fixed using self drilling /self tapping screws with aluminium/G.I. profiles to fix the sheet complete, upto any pitch in horizontal/ vertical or curved surfaces, including cutting to size and shape wherever required, as desired by engineer-in-charge. |
| 9 | P/f evaporative cooling system of 100 mm cellulose pads of coldek make with G.I. tray of 18 gauge with CPVC piping system & rainage of 32mm diawith prefilters (CACBA ISI 25to25 VISCOUS filter for 30 efficiency) with galvanised fastners and aluminium rivets, complete as per speciifcation with 500 liters PVC tank and 1HP monoblock single phase pump of crompton or equivalent make. |
| 10 | Making arrangements for manual rolling of screens of 50% green shade net material of UV resistant, as per the direction of engineer-in-charge. |
| 11 | P/f axial flow fans of size 36\" i/c making necessary arrangements, as per the direction of engineer-in-charge. |
| 12 | P/f of Humidification system for humidity range 50% to 95% with 6 nos. of 4-way nozzle foggers in chamber of discharge range 7 liters per hour operating pressure 4.0 bar with density 4.00 sqm per fogger of DAN (Israel)/net fin make with 16mm HDPE black pipng (10 kg/sqcm) average droplet size 50 to 100 cm with 1 HP monoblock single phase pump of crompton or equivalent make with 500 litre PVC tank over a MS frame with water supply CPVC pipe line of 32/25 mm dia,pressure meter of 10 bar capacity, with Hydro Cyclone filters , having leakage prevention device and control valve assembly complete. |
| 13 | Heating system:- Electric heat blower system 2.4KW complete uniform heat circulation system. |
| 14 | RO system:- Industrial RO 50lit/hrs capacity with 200 lit storage tank. |
| 15 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solventcement and testing of joints complete as per direction of Engineer in Charge.(a) 20 mm nominal outer dia Pipes |
| 16 | (b) 25 mm nominal outer dia Pipes |
| 17 | Automatic control system:- a)Microprocessor based user friendly for temperature, humidity and light dual mode function installed in Pre entry area, power input 220-415 VAC, 50Hz. Three/single phase, Ambient5-50degree celcius, RH upto90%. Relative humidity and temperature real time controller, Time forlight, individual indicator. b)Complete electrical wiring with copper wire, MCB/main switch/light/power points/ connections with motors and also cablling work of alunimium of upto 15m and all related works like connection etc. and as per the direction of engineer-in-charge. |