| 1 | Dismantling poles/ struts any size |
| 2 | Dismantling cross-arms of M.S. channel or angle sections etc. complete |
| 3 | Dismantling insulators any type, any size |
| 4 | Dismantling of ACSR or AAC conductors |
| 5 | Taking down the LED street light of any make any specification from existing PCC pole and refix the same in Steel tubular pole complete all as specified and as directed by Engr-in-charge. |
| 6 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 2 core complete all as specified and direected by Engr-in-Charge. |
| 7 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 core complete all as specified and direected by Engr-in-Charge. |
| 8 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 4 core complete all as specified and direected by Engr-in-Charge. |
| 9 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sq mm 3.5 core complete all as specified and direected by Engr-in-Charge. |
| 10 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm 3.5 core complete all as specified and direected by Engr-in-Charge. |
| 11 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 sq mm 3.5 core complete all as specified and direected by Engr-in-Charge. |
| 12 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sq mm 3.5 core complete all as specified and direected by Engr-in-Charge. |
| 13 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 sq mm 3.5 core complete all as specified and direected by Engr-in-Charge. |
| 14 | S & F hot press moulded SMC junction / terminal box of size with internal dimensions of 200 x 140 x 95 mm with hinged door, incl provision of 2 way connector 415 Volts made out of polycarbonate or Bakelite and 1 No MCB of 6 Amps with DIN bar, drilling holes for cable connections, connecting incoming and or out going cables by providing suitable of size of cable lugs/glands, fixed on pole by means of clamps made out of MS flat iron of size 25 mm x 3 mm including dismantling of old unserviceable all as specified and as directed. |
| 15 | Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor cable of size 3 core 4 sq mm served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 4 sq mm 3 core in service connections complete all as specified and directed. |
| 16 | Supply & fix in repair 90 watts LED street light fittings new generation energy saving ,environmental friendly ,long life, versatile pressure die cast aluminium IP65 with 10KV nominal voltage surge protection ,luminaire with high power LED as light source and suitable drivers etc complete all as specified and directed. Make :- Havells Cat Part No LHDBXU7I A7S090 (ENDURAPEARL PLUSS 90 W LED 757 PASYTOB CASTHO) or Crompton Cat Part CLR400850A2 (CRP4119057SLG LNSG) equivalent in Wipro cat Part No CRO2901XXX57JD |
| 17 | M&L, Stickering of any type of street light pole with A1 graded radium strip of 100mm width three colour red, Yellow and green around the pole with 100mm gap in each strip at a distance of 1.1 metre high from the ground level complete all as directed. |
| 18 | Supply and Fix Steel tubular swaged poles of type 410-SP-31 (9.0mtr long) complete with cast iron base plate, finial taper plug, bolts, nuts, screws and erected in position including painting over two coats of aluminium paint over a coat of primer and marking pole number as per give pattern complete all as specified and directed. |
| 19 | S&F bracket suitable for street light fitting made out of 40mm dia GI tubing light grade 1.5m long bent to shape, fixed with necessary nuts bolts and clamps of size 32X6mm complete all as Specified and directed. |
| 20 | Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 Mpa working pressure. |
| 21 | Excavation in trenches not exceeding 1.5 m in wide and not exceeding 1.5m in depth for laying of cables / pole and getting out in the hard/dense soil complete all as specified and as directed. |
| 22 | Excavation in trenches not exceeding 1.5 m wide and exceeding 1.5 m but not exceeding 3.0 m depth for laying of pipes/cables/erection of poles etc. and getting out in hard/dense soil complete all as specified and directed. |
| 23 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cms complete all as specified and as directed. |
| 24 | Removing excavated soil to a distance not exceeding 50m and depositing where directed at a level not exc. 1.5m above the starting point complete all as specified and as directed. |
| 25 | Supply and spreading clean, fine, dry river sand in trenches for cushioning of under ground cable / inside transformer yard complete all as specified and directed by Engineer-in-Charge. Note: Only punned thickness shall be measured for payment purpose. |
| 26 | Supply and Lay bricks common burnt clay building bricks sub class B of size 230 x 115 x 75 mm complete all as specified and directed. |
| 27 | M&L for PCC 1:3:6 type C2 using 40mm graded aggregate as in foundation, filling and mass concrete for pole / stay / post etc complete all as specified and directed. |
| 28 | M&L for PCC 1:3:6 type C1 using 20mm graded aggregate as in coping/pedestals of poles including necessary form work complete and applying two coats of white wash to exposed surface of coping/platform complete all as specified and directed. |
| 29 | S&F Galvanised iron tubing, light grade with all fittings fixed complete to walls, poles, ceilings or laid in floors/ trenches/ road crossings for the protection of cables for the following sizes all as specified and as directed. |
| 30 | (a) 40mm bore |
| 31 | (b) 80mm bore |
| 32 | Supply, installing, testing and commissioning, factory made and tested, CPRI approved LT panel board outdoor type, weather, vermin proof, cubical type, platform mounted, suitable for 415 volts, 3 phase 4 wire 50 Hz AC supply system all as specified and directed, with necessary Aluminium bus bar arrangement with insulated bus bar 1200 Amps rating , 4 strips, the panel should be dust proof, IP 54 class protection and made out of 3.15mm thick CRCA mild steel sheet with 40x40x5mm angle iron frame with necessary earth work excavation, hinged doors, front and rear opening and locking arrangement and duly powder coated on the out side and inside, cable glands and lugs for incoming and out going cable etc, independent chamber to accommodate complete all as specified and directed including following accessories :- |
| 33 | Incoming:(a) MCCB 4 Pole, 415 V, capacity 400 Amps - 01 No |
| 34 | Out going :(a) MCCB 4 pole adjustable type, 200 Amp, 415 Volts 25 KA – 02 No(b) MCCB 4 pole adjustable type, 100 Amp, 415 Volts 25 KA – 01 No (c)MCCB 4 pole adjustable type, 63 Amp, 415 Volts 16 KA – 02 No (d) MCB SP 6-32 Amp -01 No(e) Indicating lamps (set 03 Nos) - 01 set (R,Y & B)(g) 3 Phase l based Street light timer with contactor of suitable capacity -01 No(h) Panel wiring with suitable size PVC insulated heavy duty 1100 volts grade single core cable with copper conductor multistranded with cable end termination lugs. |
| 35 | Supply, installing, testing and commissioning, factory made and tested, CPRI approved LT panel board outdoor type, weather, vermin proof, cubical type, platform mounted, suitable for 415 volts, 3 phase 4 wire 50 Hz AC supply system all as specified and directed, with necessary bus bar arrangement with insulated bus bar of suitable amps rating , 4 strips, the panel should be dust proof, IP 54 class protection and made out of 3.15mm thick CRCA mild steel sheet with 40x40x5mm angle iron frame with necessary earth work excavation, hinged doors, front and rear opening and locking arrangement and duly powder coated on the out side and inside, cable glands and lugs for incoming and out going cable etc, independent chamber to accommodate complete all as specified and AS directed including following accessories :- |
| 36 | Incoming:(a) MCCB 4 pole adjustable type, 200 Amp, 415 Volts 25/35KA - 01 No |
| 37 | Outgoing: (a) MCCB 3 pole adjustable type, 100 Amp, 415 Volts 16 KA - 01 No (b) MCCB 3 pole adjustable type, 63 Amp, 415 Volts 16 KA - 01 No(c) MCCB 3 pole adjustable type, 32 Amp, 415 Volts 16 KA - 01 No(d) MCCB 3 pole adjustable type, 25 Amp, 415 Volts 16 KA - 01 No(e) Indicating lamps (set 03 Nos) - 01 set (R,Y & B)(f) Digital mounted Voltmeter and ammeter three phase(g) Panel wiring with suitable size PVC insulated heavy duty 1100 volts grade single core cable multistranded with cable end termination lugs. |
| 38 | M & L for dismantling of old LT panel and Supply, installing, testing and commissioning, factory made and tested, CPRI approved LT panel board outdoor type, weather, vermin proof, cubical type, platform mounted, suitable for 415 volts, 3 phase 4 wire 50 Hz AC supply system all as specified and directed, with necessary insulated bus bar arrangement of 4 strips, the panel should be dust proof, IP 54 class protection and made out of 3.15mm thick CRCA mild steel sheet with 50x50x6mm angle iron frame with necessary earth work excavation and PCC foundation, hinged doors, front and rear opening and locking arrangement and duly powder coated on the out side and inside, cable glands and lugs for incoming and out going cable etc, independent chamber to accommodate complete all as specified and directed including following accessories :- |
| 39 | INCOMINGa) Bus bar chamber with electrolytic aluminium bus bar suitable for 300 amps capacity for 3 phase and neutral 150 amps (all connection inside the panel shall be through aluminium strip) connected duly supported with FRP insulators including colour code heat shrieked insulating sleeves - Set -1(b) MCCB 4 pole adjustable thermal and fixed magnetic setting type , 250 Amp, 415 Volts 36 KA – 01 No |
| 40 | OUTGOING:(a) MCCB 4 Pole adjustable thermal and fixed magnetic setting type 160 Amp 415 volts 36 KA - 02 Nos (b) MCCB 4 Pole adjustable thermal and fixed magnetic setting type 100A 415 Volts 25 KA-01 Nos(c) MCCB TPN 63A, 415 volts 16 KA - 01 No(d) Indicator lamps 22.5mm dia LED type for 3 phase as R-Y-B, 03 Nos - 01 Set.(e) Digital Ammeter to measure current having programmable CT ratio 500/5Amps and built in selector switch of size 96mm x 96mm and suitable for frequency 50-60 HZ - 01 No. (f) Digital voltmeter with auxiliary voltage inner to measure voltage having built in selector switch of size 96mm x 96mm shall be adequately protected through the use of 2 Amps SP MCB frequency 50-60 HZ - 01 No.(g) All accessories will be prewired with suitable size of copper thimble, copper conductor cable of size 2.5 Sqmm single core as required. The cable shall be used for all outgoing ways as an insulated with fibre glass insulation. |
| 41 | Supply, installing, testing and commissioning, factory made and tested, CPRI approved LT panel board outdoor type, weather, vermin proof, cubical type, platform mounted, suitable for 415 volts, 3 phase 4 wire 50 Hz AC supply system all as specified and directed, with necessary bus bar arrangement with insulated bus bar of suitable Amps rating , 4 strips, the panel should be dust proof, IP 54 class protection made out of 3.15mm thick CRCA mild steel sheet with 40x40x5mm angle iron frame with necessary earth work excavation, hinged doors, front and rear opening and locking arrangement and duly powder coated on the out side and inside, cable glands and lugs for incoming and out going cable etc, independent chamber to accommodate complete all as specified and directed including following accessories |
| 42 | Incoming:(a) MCCB 4 pole adjustable type, 250 Amp, 415 Volts 35/25KA - 01 No |
| 43 | Outgoing(a)MCCB 3/4 pole adjustable type, 100 Amp, 415 Volts 25 KA - 03(b)MCCB 3/4 pole adjustable type, 63 Amp, 415 Volts 16 KA - 03(c) Indicating lamps (set 03 Nos) - 01 set (R,Y & B)(e) Digital panel mounted Voltmeter and ammeter, street light timer suitable (f) Panel wiring with suitable size PVC insulated heavy duty 1100 volts grade single core cable with conductor multistranded with cable end termination lugs. |
| 44 | Supply, installation connecting electrically commissioning and testing complete outdoor type, as recommended by manufacturer, Automatic Power Factor Correction(APFC) system made out of 3.15mm th CRCA Sheet 7 stage type intel VAr APFC Panel with heavy duty MPPH capacitors and MCCBs as incomer factory made single unit 440 volts, 50 Hz, 3 phase 50 KVAR (4 No X 5 KVAR+ 3 No X 10 KVAR) including taking down old existing one and comprising with following provisions :- |
| 45 | (a) Metallised polypropylene MPP-H capacitor bank heavy duty of rating 50 KVAR (4 No X 5 KVAR+ 3 No X 10 KVAR) confirming to IS-2834, IS-13340, 3341 & IEC 931. Make: L&T / EFCOS / MEHER(b) Capacitor duty contactor of appropriate rating for capacitor switching confirming to IEC-947-4-1 and IS 13947. Make: L&T / EFCOS / MEHER(c) Automatic power factor controller relay micro processor based for switching ON & OFF of capacitors suitable to disconnect capacitor bank on No voltage. Visual alarm if unit fails to achieve required power factor automatic lock out of faulty, steps and display of power factor achieved (leading of lagging). Make: L&T / EFCOS / MEHER(d) Digital volt meter and ammeter of range as required and recommended by manufacturer with in-built selector switch and CTs of appropriate ratio.(e) MCCB 63 Amps 3 pole rupturing capacity 10 KA of appropriate rating for protection of individual capacitor bank confirming to IS 8828, IEC 898. (f) MCCB 125 Amps 4 pole 415 volts of appropriate current rating with rupturing capacity 35 KA as incomer confirming to IS 13947 part 2, IEC 947 2. |
| 46 | Supply, installing, testing and commissioning, factory made and tested, CPRI approved LT panel board outdoor type, weather, vermin proof, cubical type, platform mounted, suitable for 415 volts, 3 phase 4 wire 50 Hz AC supply system all as specified and directed, with necessary bus bar arrangement with insulated bus bar of suitable Amps rating , 4 strips, the panel should be dust proof, IP 54 class protection made out of 3.15mm thick CRCA mild steel sheet with 40x40x5mm angle iron frame with necessary earth work excavation, hinged doors, front and rear opening and locking arrangement and duly powder coated on the out side and inside, cable glands and lugs for incoming and out going cable etc, independent chamber to accommodate complete all as specified and directed including following accessories |
| 47 | Incoming:(a) MCCB 4 pole adjustable type, 160 Amp, 415 Volts 35/25KA - 01 No |
| 48 | Outgoing : (a) MCCB 3/4 pole , 100 Amp, 415 Volts 25 KA - 04(b) MCCB 3/4 pole adjustable type, 63 Amp, 415 Volts 16 KA - 02(c) Indicating lamps (set 03 Nos) - 01 set (R,Y & B)(e) Digital panel mounted Voltmeter and ammeter, street light timer(f) Panel wiring with suitable size PVC insulated heavy duty 1100 volts grade single core cable with copper conductor multistranded with cable end termination lugs. |
| 49 | M & L earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5m below ground level, connecting to the Galvanised iron earth strip 32 x 6mm dia, by means of nuts, bolts, check nuts and washer etc of galvanised iron and earth lead protected by provision of GI pipe medium grade 40mm bore from earth electrode to test point incl provn of concrete pit in PCC (1:2:4) type B-1 using 20mm graded stone aggregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM sheet (weight not less than 4Kg/Sqm) and frame of angle iron 25 x 25 x 6mm with lugs 2 Nos and with 8mm dia MS bar handle made to shape, GI pipe medium grade 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling test point with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning in and removal of surplus soil to a distance not exceeding 50mtr, complete all as specified in electrical plate No 3 of SSR Part I and connection to earth test point including testing on completion all as directed. Note:- Item of earthing includes cost of 7.5m long galvanised iron earth strip of 32 x 6mm size and protection pipe of 40mm bore GI medium grade. |
| 50 | M & L earthing complete with copper plate 60×60cm ×3.15mm thick buried directly in ground earth pit not less than 2.25 mtr deep below normal ground level with top edge of plate not less than 1.5m below ground level, connecting to the 20×3mm copper strip as earthing lead, by means of nuts, bolts, check nuts and washer etc of galvanised iron and earth lead protected by provision of GI pipe medium grade 40mm bore from earth electrode to test point incl provn of concrete pit in PCC (1:2:4) type B-1 using 20mm graded stone aggregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM sheet (weight not less than 4Kg/Sqm) and frame of angle iron 25 x 25 x 6mm with lugs 2 Nos and with 8mm dia MS bar handle made to shape, GI pipe medium grade 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling test point with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning in and removal of surplus soil to a distance not exceeding 50mtr, complete all as specified in electrical plate No 3 of SSR Part I and connection to earth test point including testing on completion all as directed. Note:- Item of earthing includes cost of 7.5m long copper strip of 20×3mm size and protection pipe of 40mm bore GI medium grade. |
| 51 | M & L earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5m below ground level, connecting to the Galvanised iron earth wire 4mm dia, by means of nuts, bolts, check nuts and washer etc of galvanised iron and earth lead protected by provision of GI pipe light grade 20mm bore from earth electrode to test point incl provn of concrete pit in PCC (1:2:4) type B-1 using 20mm graded stone aggregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM sheet (weight not less than 4Kg/Sqm) and frame of angle iron 25 x 25 x 6mm with lugs 2 Nos and with 8mm dia MS bar handle made to shape, GI pipe light grade 15mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling test point with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning in and removal of surplus soil to a distance not exceeding 50mtr, complete all as specified in electrical plate No 3 of SSR Part I and connection to earth test point including testing on completion all as directed. Note:- Item of earthing includes cost of 7.5m long galvanised iron earth wire of 4 mm size and protection pipe of 20mm bore GI light grade. |
| 52 | M&L cutting of road/hard standing up to a size not exceeding 20 cm in width and not exceeding 60 cm in depth for laying of LT UG cable/protection pipe line making good the disturbed portion so as to match existing finishing with PCC 1:2:4 type B1/cement mortar in CM (1:2) complete all as specified and directed |