| 1 | Providing and amp; Laying P.V.C. / XLPE insulated and amp; P.V.C. sheathed Armoured Copper cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with electrolytic grade Copper made of copper rods confirming to IS 613-1964, of purity and gt;99.7 %, round / flat strip armouring, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810 For additional technical parameters of product / work refer Annexure A attached with this BSR 25.0 Sq. mm - 4 core |
| 2 | Supplying and making one end termination with Nickel plated heavy duty brass single compression gland (as per IS 12943-1990)) SIBG type consisting of Check Nut, Gland Body, Metal Washer(3 Nos.), Outer Seal Rubber Ring, Compression Nut, heavy duty Copper lugs (IS 8337- 1976) duly crimped with crimping tool, PVC tape for following size of PVC insulated and amp; PVC sheathed/ XLPE copper conductor cable of 1100 volt grade as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . - 4 x 25.0 sq.mm |
| 3 | Providing and amp; Fixing of ISO certified company made bus bar chamber housed in sheet metal box as per PWD specification for electrical Works Confirming to IEC-60439/IS-8623 and amp; IEC-60529/IS-2147 made out from 1.6 mm thick powder coated CRCA sheet,degree of protection IP-31, front openable bus bar made out of Copper suitable for 100 amp. Capacity , bus bar fixed on porcelain/DMC insulators at approved spacing including making connections etc. as required. Appropriate type test certificate / OEM test report shall be submitted . All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . - 300 mm long , 4 strip |
| 4 | P and amp; F of Industrial plug and socket conforming to IEC 60309-1/2 made out of self extinguishing engineering polymer / polyamide, nickel plated brass sleeve and pins, socket with shutter including making connection etc as reqd. and nbsp;For additional technical parameters of product / work refer Annexure A attached with this BSR IP -67 Surface/Wall mounted socket - 63 A 5 pin(3P+N+E) |
| 5 | P and amp; F of Industrial plug and socket conforming to IEC 60309-1/2 made out of self extinguishing engineering polymer / polyamide, nickel plated brass sleeve and pins, socket with shutter including making connection etc as reqd. and nbsp;For additional technical parameters of product / work refer Annexure A attached with this BSR IP - 67 Plug top - 63 A 5 pin(3P+N+E) |
| 6 | P and amp; F and nbsp; Surface mounting IP-65, IK-09 Class-II self extinguishing insulating material weather proof cabinets and nbsp; confirming to EN60439-3 with IP-65 Key lock, and nbsp; fully reversible door and cabinet, removable chasis and face plates, of following size. and nbsp;For additional technical parameters of product / work refer Annexure A attached with this BSR - 1 row 6 module and nbsp; |
| 7 | Providing and amp; Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum material with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass cover and secondary lens on each LED and amp; should be SMD type of 3 to 5 watt each . The System efficacy and gt;=125 lm/ wt and potted driver and amp; has a unique BIS R number with Input Voltage AC 120 to 270 V AC with High voltage Cutoff @ and gt;=300 V AC and Auto resetting Safety , Power Factor and gt;0.95 driver Efficiency and gt;85% ,THD(I) and lt;10% Humidity 10% to 90% RH Working Temp -5C to 45C . driver current and lt;750mA. The luminaire shall be BIS certified and Trade mark certified. Life Expectancy Equal or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI and gt;70 and CCT 5700K +355K. Surge protection shall be min = 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs. Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . - LED Street Light fixture with Minimum lumen output 7500 lm |
| 8 | Providing and amp; Fixing of IK08 IP-66 protected high power LED flood light system with single piece Pressure diecast aluminium housing, toughened glass diffuser with suitable lenses on LED to achieve various beam angles, of high power LED of 3 to 5 watt each . Integrated potted driver as a unique BIS R number having efficiency more than 85 % and in compliance to BIS certified and Trade mark certificate. The System level Luminaire efficacy and gt;=125 lm/ wt. LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff @ and gt;=300 V AC and Auto resetting Safety .Power Factor and gt;0.95 , THD(I) and lt;10% , driver current and lt;=750mA. driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector , Surge Protection Min and gt;=4KV internal and 10KV external but inside driver compartment, System life of 50000 Burning hours with 70% of Initial Lumens maintained, CRI and gt;70 and CCT 5700K ±355K. Manufactures Word Mark/Name Engraved/Embossing/Screen printing on die cast housing to allow traceability/authenticity. Fixture shall be IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . - High Power LED Flood Light Minimum lumen output 37500 lm |
| 9 | Providing and amp; Fixing of IK08 IP-66 protected high power LED flood light system with single piece Pressure diecast aluminium housing, toughened glass diffuser with suitable lenses on LED to achieve various beam angles, of high power LED of 3 to 5 watt each . Integrated potted driver as a unique BIS R number having efficiency more than 85 % and in compliance to BIS certified and Trade mark certificate. The System level Luminaire efficacy and gt;=125 lm/ wt. LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff @ and gt;=300 V AC and Auto resetting Safety .Power Factor and gt;0.95 , THD(I) and lt;10% , driver current and lt;=750mA. driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector , Surge Protection Min and gt;=4KV internal and 10KV external but inside driver compartment, System life of 50000 Burning hours with 70% of Initial Lumens maintained, CRI and gt;70 and CCT 5700K ±355K. Manufactures Word Mark/Name Engraved/Embossing/Screen printing on die cast housing to allow traceability/authenticity. Fixture shall be IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . - High Power LED Flood Light Minimum lumen output 3700 lm |
| 10 | Providing and amp; Fixing of IK08 IP-66 protected high power LED flood light system with single piece Pressure diecast aluminium housing, toughened glass diffuser with suitable lenses on LED to achieve various beam angles, of high power LED of 3 to 5 watt each . Integrated potted driver as a unique BIS R number having efficiency more than 85 % and in compliance to BIS certified and Trade mark certificate. The System level Luminaire efficacy and gt;=125 lm/ wt. LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff @ and gt;=300 V AC and Auto resetting Safety .Power Factor and gt;0.95 , THD(I) and lt;10% , driver current and lt;=750mA. driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector , Surge Protection Min and gt;=4KV internal and 10KV external but inside driver compartment, System life of 50000 Burning hours with 70% of Initial Lumens maintained, CRI and gt;70 and CCT 5700K ±355K. Manufactures Word Mark/Name Engraved/Embossing/Screen printing on die cast housing to allow traceability/authenticity. Fixture shall be IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . - High Power LED Flood Light Minimum lumen output 18650 lm |
| 11 | Supplying and drawing FR PVC insulated and amp; unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR - 2 x 1.5 sq.mm |
| 12 | Providing and amp; Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A and amp; above rating including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports and amp; All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR Double pole MCB(With B/C curve tripping Characteristics) - 6 A to 32 A rating |
| 13 | Providing and amp; Fixing of Cam operated rotary (Auto/manual) switches on existing panel with 2 way and off position using high grade engineering material to international standards with cam assembly insulation of glass filled polyamide with high tracking index. For reliable and stable electrical and mechanical endurance double butt contacts with silver bi-metal on copper should provided . contact assembly is of operating temp range -25 degree C to 55 degree C, frequency upto 10 KHz. switch life under std. op. conditions shall be mechanically minimum 50000 operations @300 cycles/ hour and electrically 10,000 operations at 100% rated duty for 100 cycles/ hour including making connection etc. as required . All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . - 32 AMP |
| 14 | Providing and amp; Fixing of Recessed/surface mounting heavy duty Enclosure made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick and nbsp; conforming to IS-8623-1 and amp; 3 / and nbsp; IEC 61439- 1 and amp; 3. powder painted complete with din rail and nbsp; making internal DB and nbsp; terminations with copper lugs, and nbsp; detachable gland plate, including making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR - Suitable for Two / Three / Four module for MCB |
| 15 | Mason/ Painter/ Carpenter/ Electrician /Black smith / Plumber Grade I |
| 16 | Helper for Mason/ Mistri / Painter/ Carpenter/ Electrician /Black smith / plumber / survey work/Fitter |