Tender For Upgradation, Interior/Furnishing Work Of Commissioner Lucknow Division Lucknow Office - TOILET SANITARY FITTING WORK 2 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal outer dia Pipes.DSR -18.8.2 3 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 25 mm nominal outer dia Pipes.DSR -18.8.3 4 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 32 mm nominal outer dia Pipes.DSR - 18.8.4 5 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board 510x1040 mm bowl depth 250 mmDSR - 17.10.1.1 6 Providing & Placing of Looking Mirror pasted on wall with the help of silicon having edges beveled, all complete as per drawing, specification and directionas approved by the Architect/ Engineer -in-Charge. Customized MR 7 Providing & Fixing ofConcealed Stop Cock With Trims as per the approveddesign all complete as per drawing, specification and direction of engineer incharge. Make-Kerovit/Equivalent MR 8 Providing & Fixing ofFloor Drainer as per the approveddesign all complete as per drawing, specification and direction of engineer incharge.Make-Kerovit/Equivalent MR 9 Providing & Fixing ofWall hung Closet with Soft Close Seat Cover Fixed with Jumbo Bolts as per the approveddesign all complete as per drawing, specification and direction of engineer incharge. Make-Kerovit/Equivalent MR 10 Providing & Fixing of Concealed Cistern With Push Plate as per the approveddesign all complete as per drawing, specification and direction of engineer incharge. Make-Kerovit/Equivalent MR 11 Providing and fixing of Under Counter Basin as per the approveddesign all complete as per drawing, specification and direction of engineer incharge. Make-Kerovit/Equivalent MR 12 Providing & fixing ofSensor Tap as per the approveddesign all complete as per drawing, specification and direction of engineer incharge. Make-Kerovit/Equivalent MR 13 Providing & fixing ofUrinal With Sensor as per the approveddesign all complete as per drawing, specification and direction of engineer incharge. Make-Kerovit/Equivalent MR 14 Providing & fixing ofUrinal Division Plate as per the approveddesign all complete as per drawing, specification and direction of engineer incharge. Make-Kerovit/Equivalent MR 15 Providing and fixing Sink Cock as per the approveddesign all complete as per drawing, specification and direction of engineer incharge. Make-Kerovit/Equivalent MR 16 Providing and fixing 2 Way Bib Tap as per the approveddesign all complete as per drawing, specification and direction of engineer incharge.Make-Kerovit/Equivalent MR 17 Providing & fixing Health Faucet as per the approveddesign all complete as per drawing, specification and direction of engineer incharge.Make-Kerovit/Equivalent MR 18 Providing and fixing of Angle Cock as per the approveddesign all complete as per drawing, specification and direction of engineer incharge. Make-Kerovit/Equivalent MR 19 Providing and fixing of Bottle Trap as per the approveddesign all complete as per drawing, specification and direction of engineer incharge. Make-Kerovit/Equivalent MR 20 Providing and fixing of Toilet Paper Holder as per the approveddesign all complete as per drawing, specification and direction of engineer incharge. Make-Kerovit/Equivalent MR 21 Providing and fixing of Towel Ring as per the approveddesign all complete as per drawing, specification and direction of engineer incharge. Make-Kerovit/Equivalent MR 22 Providing and fixing of Soap Dish as per the approveddesign all complete as per drawing, specification and direction of engineer incharge. Make-Kerovit/Equivalent MR 23 Providing and fixing of Waste Coupling as per the approveddesign all complete as per drawing, specification and direction of engineer incharge. Make-Kerovit/Equivalent MR 24 Providing and fixing of Long Braided Hos Pipe as per the approveddesign all complete as per drawing, specification and direction of engineer incharge. MR 25 Providing and fixing of 10ltr Gyser as per the approveddesign all complete as per drawing, specification and direction of engineer incharge. Make-AO Smith/Equivalent MR 26 Providing and fixing of 110mm dia pipe 6kg pressure of Supreme/Astral make or equivalent, including supply of all materials, labour and T&P etc. MR 27 Providing and fixing of 110mm dia 90 Degree Elbow 6kg pressure of Supreme/Astral make or equivalent, including supply of all materials, labour and T&P etc. MR 28 Providing and fixing of 110mm dia 45 Degree Elbow, 6kg pressure of Supreme/Astral make or equivalent, including supply of all materials, labour and T&P etc. MR 29 Providing and fixing of 110mm dia Coupler, 6kg pressure of Supreme/Astral make or equivalent, including supply of all materials, labour and T&P etc. MR 30 Providing and fixing of 110mm dia Tee, 6kg pressure of Supreme/Astral make or equivalent, including supply of all materials, labour and T&P etc. MR 31 Providing and fixing of 110x75mm dia Nahani Trap, 6kg pressure of Supreme/Astral make or equivalent, including supply of all materials, labour and T&P etc. MR 32 Providing and fixing of 75mm dia pipe 6kg pressure of Supreme/Astral make or equivalent, including supply of all materials, labour and T&P etc. MR 33 Providing and fixing of 75mm dia 45 Degree Elbow, 6kg pressure of Supreme/Astral make or equivalent, including supply of all materials, labour and T&P etc. MR 34 Providing and fixing of 75mm dia Coupler, 6kg pressure of Supreme/Astral make or equivalent, including supply of all materials, labour and T&P etc. MR 35 Providing and fixing of 75mm dia Y Tee, 6kg pressure of Supreme/Astral make or equivalent, including supply of all materials, labour and T&P etc. MR 36 INTERIOR WORK ESTIMATE 37 Providing & Fixing of at all height false ceiling including providing and fixing of frame made of special section power pressed from m.s. sheet and galvonised in accordance with zinc coatingof grade 350 as per IS 277and consisting of angle cleat 25x1.6mm with flanges of 27mm and 37mmat 1200mm c/c one flangedfix to the ceiling with dash fastener 12.5mm dia and and 40mm long with 6mm dia boltto the angle hangers of 25x25x0.55 mm of required lengthened other end of angle hanger being fixed with nut and bolts to GI channel 45x15x0.90mm running at the rate of 1200 mm c/c to with the ceiling section 0.5mm thick button wedges of 80mm with tappered flenges of 26 mm each having clips of 10.5mm.at 450mmc/ cshall be fixed in direction perpendicular to GI channels with connecting clipsmade out of 2.64MM diax230mm longGI wire at every junction including fixing the gypsumboard with ceiling section and perimetre channels 0.50 mm thick 27mm high having flenges of 20mm and 30mm long ,perimeter of ceiling fixed to wall /partitionwith help of rawl plugs at 450mm c/c with 25 mm long drive all screws @230mm interval including jointing and fixingto a flush finish of tapperedend sq edge of board with recommended filler jointing and tapper finisher and two coat of primer suitable for board as per manufacturers specification and also including the cost of making of openning for light fittings grills diffusers cutouts made with frame of perimeter channelssuitably fixed all complete as per drawing and specification and direction of engineer incharge but excluding the cost of painting. 12.50mm thick tapered edge gypsum board.DSR-12.45.1 38 Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main T runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross T of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main T at 600 mm center to center to form a grid of 1200x600 mm and secondary cross T of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main T runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient ) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece. DSR -12.52.2 39 Providing & Fixing of Armstrong Suspended Ceiling System with Armstrong H4988 BP4988S DUNE Bev. Teg. 600x600x15mm (Microlook) EDGE TILES WITH ARMSTRONG Silhouette Exposed GRID. The tiles should have Humidity Resistance (RH) of 95%, NRC 0.9 - 1.0, Light Reflectance ≥85%, Colour White, Fire Performance UK Class 0 / Class 1 (BS 476 pt - 6 &7) in module size of 600 x 600 x 15mm ,and 600x1200x15mm suitable for Green Building application, with Recycled content of 66% GW.The tile shall be laid on Armstrong Silhouette profile grid system with 15mm white flanges incorporating a 6mm central reveal in white/black colour and with a web height of 38mm.Silhouette, Main Runners & Cross Tees to have mitred ends & “birdsmouth” notches to provide mitred cruciform junctions. The T Sections have a Galvanizing of 90 grams per M2 and a load carrying capacity of 10 Kgs/M2.The Tile & Grid system used together, all complete as per drawing, specification and directionas approved by the Architect/ Engineer -in-Charge M.R 40 Providing & making false ceiling system with GI section frame work cladded with 12mm plySurface to be finished 4mm thick veenear complete with polishas per standard design all complete as per drawing and specification and direction of engineer incharge. M.R 41 Providing and fixing of 12 mm thick highglossLaminated wooden flooringrange grand illusion/studio Classification of Use 23/32 (Heavy Domestic/Domestic) with a Surface Abrasion Resistance of class AC3 (average 4500 cycles), Impact Resistance of IC2 (EN13329), Resistance to Cigarette Burn with a rating of 5 (EN 438-2:15), Swelling after 24 hrs in water of 15% (EN13329), Modulus of Rupture of 53.3 newton/mm2, Internal Bond 1.78 newton/mm2, Surface Soundness of 1.3 newton/mm2 (EN 13329:2000) with a 0.2mm thick wear layer on top of a High Density Fiber substrate core (density > 850 Kg/M3) of plank size 1212 mm X 137 mmhaving Uni fitlocking arrangement (lock strength > 1000 lbs/ft) with an underlayment made of natural colour foam , with accessories like End profile, Transition profile, reducer, etc. complete. The rate includes cost of all materials, accessories, labour, HOM, etc., complete at all levels. (The Shade, pattern etc., to be approved by Engineer in charge)Make-FloorMaster/Armstrong/Haro. all complete as per drawing, specification and directionas approved by the Architect/ Engineer -in-Charge. Make-Armstrong,Mikasa,Luxe EquivalentM.R 42 Providing and laying of printed saxony carpet of CARUSBrand, manufactured by Beaulieu International Group or equivalent, having 100% Type 6 Nylon/Polyamide Crealon or equivalent and 1/10 gauge, . The carpet should have a primary backing of woven pp and secondary backing of weaveback to ensure high performance and comfort. The carpet should be of 4M width to ensure lesser joints and minimum wastage. It should have a minimum total weight of 1650 gsm and minimum pile weight 800 gsm , minimum number of tufts to be 185040 or more The carpet should also qualify to the following minimum European standards performance specifications - (a) Fastness to rubbing, dry(ISO 105 X-12), minimum rating should be 4-5; (b) Fatness to rubbing, wet (ISO 105 X-12), minimum rating should be 5; (c) Water fastness, (ISO 105 E-01), minimum rating should be 4-5; (d) Fastness to light (ISO 105 B-2), minimum rating should be 5; (e) Thermal Resistance (ISO 8302), minimum rating should be 0,072 m² K/ W; (f) Impact sound insulation (ISO 140 - 8), minimum rating should be 25dB. The carpet should be Scotchguard ready for better stain resistance, and should have an approved fire rating of Class 1 under Bf1S1 and should be recommended for commercial usage under Class 23/32 classification.duly installed on smooth hard floor with support of 10 mm epe sheet & company recommended adhesive.M.R 43 Providing & Making & Fixing of Commercial Wall Panneling made with Aluminium Section of 2x1 @ 2CC frame work cladded with 12MM Ply complete with painted or polishe.as per the approveddesign all complete as per drawing, specification and directionas approved by Engineer -in-Charge. M.R 44 Providing & Making & Fixing of Commercial Wall Partition made with Aluminium Section of 2x1 @ 2CC frame work cladded with 9MM Ply on Both Side complete with painted or polishe.as per the approveddesign all complete as per drawing, specification and directionas approved by Engineer -in-Charge. M.R 45 Providing & fixing Toughned glass Parition with 12mm Modi float glass fixed edge to edge as per design and drawing and polished where required along with neccesary hardware all complete as per drawing, specification and direction of engineer incharge. M.R 46 Providing & Making & Fixing of Wall Panneling made with 1MM Laminate & 5.5MM MDF on Existing Surface complete with painted or polishe.as per the approveddesign all complete as per drawing, specification and directionas approved by Engineer -in-Charge. M.R 47 Providing & Making & Fixing of Wall Panneling made with 4MM Veneer on Existing Surface complete with Melamine Polishe.as per the approveddesign all complete as per drawing, specification and directionas approved by Engineer -in-Charge. M.R 48 Providing & Making & Fixing of Wall Panneling made with 12MM Louver on Existing Surface complete with Melamine Polishe.as per the approveddesign all complete as per drawing, specification and directionas approved by Engineer -in-Charge. M.R 49 Providing & Making & Fixing of Wall Panneling made with Coloured Lacquered Glass on Existing Surface complete with Melamine Polishe.as per the approveddesign all complete as per drawing, specification and directionas approved by Engineer -in-Charge. M.R 50 Providing & Making & Fixing of Storage Cabinet made of 19mm board, having shelves & shutters & teak wood beading & finished surface of 1mm thick Laminateincluding all hardware like tower bolts, hinges, lock & handle as per approved drawing & direction of Engineer incharge.M.R 51 Providing and Fixing Channeled Woodworks perforated panels of width 128mm, thickness of 16mm and length 2440 mm or as required by the Architect/ approving engineer, made of a high density particle board substrate with a laminated facing as per the approved shade & finish and a melamine balancing layer on the reverse side. The boards shall have a special perforation pattern where the visible surface has a (“Helmholtz” fluted perforation of 2mm width and 14mm of visible panel / 4mm width and 28mm visible panel) each. The panels shall provide a minimum sag resistance of RH90 and a fire rating class of 1 as per Part 7 of BS 476. The edges of the panels shall be “tongue-and-grooved” to receive special clips for installation. The back of the perforated panel shall have sound absorbing non-woven acoustical fleece. The panels shall be mounted on special aluminium splines using clips. as per the approved designas approved by Engineer -in-Charge. M.R 52 Providing and supplying ‘Optra Acoustical Wall Paneling’ with square edges made of fibre glass substrate 25mm thick and wrapped on the front side with an acoustically transparent and fire -resistant fabric with an option of colours as per the choice of the Architect/ Person in-charge of size 1200x600 or 600x600 mm providing a minimum sound absorption level of 0.90 NRC to be affixed to wall using Wall panel impalers and construction adhesives as per the instructions laid down by the manufacturer as per the approved designas approved by Engineer -in-Charge. M.R 53 Providing & fixing of 12 mm Toughened Glass Door with all hardwareas per design with edge polish m/c top & bottom pivot and bottom lockwith handle all complete as per drawing, specification and directionas approved by Engineer -in-Charge. M.R 54 Providing & fixing of Flush Door Laminated both side complete with all fittings,Round mortis lock,door closer etc all complete as per drawing, specification and directionas approved by Engineer -in-Charge. M.R 55 Providing & Fixing of Plotter Cutted Designer Film of approved shade as per drawing & specificationas approved by Engineer -in-Charge. M.R 56 Providing & Fixing of Wall Paper of approved shade as per drawing & specificationas approved by Engineer -in-Charge. M.R 57 Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. DSR-13.91 58 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.DSR-13.80 59 Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr /10 sqm DSR-13.48.1 60 Providing and laying of Double Charged floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x1200mmMR 61 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm DAR-11.41.2 62 Grouting the joints of flooring tiles having joints using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge.DSR-11.48.2 63 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite stone slab colour black, Cherry/Ruby red Area of slab over 0.50 sqm DSR-8.2.2.2 64 Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.DSR-8.5 65 ELECTRICAL WORK ESTIMATE 66 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. Group A DSR(1.10.1) 67 Supply and fixing of Power point and Supply and fixing of power plug with 10 Amp./250 volt flush type modular switch and 5 pin 10A /250 volt flush type universal modular socket switch on concealed M.S. box including supply of all material, labour t&P etc. required for proper completion of work. DSR(1.31) 68 Supply and fixing of wire, Power point and Supply and fixing of power plug with 20 Amp./250 volt flush type modular switch and 5 pin 20 nA/250 volt flush typ[e universal modular socket switch on concealed M.S. box including supply of all material, labour t&P etc. required for proper completion of work. DSR(1.32) 69 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire DSR(1.14.1) 70 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire DSR(1.14.2) 71 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 X 4.0 sq. mm + 1 X 4.0 sq. mm earth wire DSR(1.14.3) 72 Supplying & Drawing co-axial TV cable RG-6 grade, 0.7 mm. solidcopper conductor, PE insulated] shielded with fine finned copper braid and protected with PVC sheath in the existing surface/ recessed steel/PVC conduit as required. For T.V. Socket outlet DSR(1.19) 73 Supply & Fixing of following sizes of medium class PVC conduit alongwith accessories in sueface/recess including cutting the wall & making it good the same in case of recessed conduit as required. 20MM DSR(1.21.1) 74 Supply & Fixing of following sizes of medium class PVC conduit alongwith accessories in sueface/recess including cutting the wall & making it good the same in case of recessed conduit as required. 25MM DSR(1.21.2) 75 Supply & Fixing of following sizes of medium class PVC conduit alongwith accessories in sueface/recess including cutting the wall & making it good the same in case of recessed conduit as required. 32MM DSR(1.21.3) 76 Supply and fixing of recess mounting round15 TO 18 Watt LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/ Reflector and driver set complete in all respect. CAT-AAAS.I 1403 77 Supply and fixing of 36 Watt to 46 Watt above 3300 leumin indoor Recess mounting LED Square Fitting for Armstrong Ceiling having Powder coated die cast aluminium housing body with extended heat sink and diffuser of Special Polycarbonate meterial and driver set complete in all respect. CAT-AAAS.I 1406 78 Supplying & fixing of TV Antenna socket on Modular Plate & G.I Box including connections DSR(1.27.1+1.24.7+1.28.1) 79 Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required, 1 or 2 ModuleDSR(1.28.1) 80 Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required, 3 ModuleDSR(1.28.2) 81 Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required, 4 ModuleDSR(1.28.3) 82 Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required, 6 ModuleDSR(1.28.4) 83 Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required, 8 ModuleDSR(1.28.5) 84 Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required, 12 ModuleDSR(1.28.6) 85 Blank plate for modular plate type switch boards wherever required.DSR(1.26) 86 Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. 25 Sqmm 3.5 core S.I 501(J) 87 Supply and fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respect. The armouring of the cable shall be properly connected with the earth as per direction of Engineer- Incharge. 25 sq. mm 3-1/2 coreS.I 503 (J) 88 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge. 25 sq. mmS.I 504 (E) 89 Supply and fixing of 6Amp to 32Amp SPMCB(10KA) C Curve CAT-A4 Pole Isolator CAT-AS.I 1002(A) 90 Supply and fixing of 63Amp 4 Pole Isolator CAT-AS.I 1007(B) 91 S & F surface/Flush mounting 12ways TPN distribution board with additional metal door without MCB complete in all respect,as directed at site by Engineer in charge. CAT-AS.I 1029(A) 92 Providing Drawing Connecting And Testing Of Enhanced Categoey 4 Pair Lan Local Area Network Cable 24 AWG Conductor Performance Specifide 5E U L and CUL Listed In Existing PVC Conduit .(CAT-6 Network Cable)DSR (1.53) 93 Supply & Fixing of LED Profile Light all complete as per drawing and specification and direction of engineer incharge. Make-Ledadvance/Ledos/Ledlum/Philips, EquivalentM.R 94 Supply & Fixing of LED Profile Light Driver all complete as per drawing and specification and direction of engineer incharge. Make-Ledadvance/Ledos/Ledlum/Philips, EquivalentM.R 95 Supply and fixing of 400mm Wall Fan all complete as per drawing and specification and direction of engineer incharge. Make-Crompton/Bajaj/Havels Equivalent M.R 96 Supply and fixing of 150mm Fresh Air Fan all complete as per drawing and specification and direction of engineer incharge. Make-Crompton/Bajaj/Havels Equivalent M.R 97 Supply and fixing of 250mm Fresh Air Fan all complete as per drawing and specification and direction of engineer incharge. Make-Crompton/Bajaj/Havels Equivalent M.R 98 Supply and Fixing of Deep Recess Mounting round 10 Watt COB LED Spot Light having Powder coated die cast aluminium housing with heat sink, diffuser/ Reflector and driver set complete in all respect. Make-Ledadvance/Ledos/Ledlum/Philips, EquivalentM.R 99 Supply & Fixing of Hanging Light all complete as per drawing and specification and direction of engineer incharge. Make-Ledadvance/Ledos/Ledlum/Philips, EquivalentM.R 100 Providing & Fixing of Modular plate type white RJ 45 CAT 6 Data/Talephone outlet / information outlets ETL verified to meet or exceed TIA / EIA category 6 requirements, universal wiring label permitting to either T568A or T568B, UL listed,for computer networkingcomplete in all respect with cover plate, grid plate, screws, MS box, etc with connections as required with 2nos RJ-45 Data outletM.R 101 IP UNIFIED COMMUNICATION & CCTV SYSTEM WORK 102 Supply, Installation, testing and commissioning of 42U Rack complete with standard accessories Make - Dlink/Comrack 103 Supply, Installation, testing and commissioning of Cat 6 patch panel, loaded. Make - Dlink 104 Supply, Installation, testing and commissioning of modular patch cables 1m 10/100/1000 Make - AMP/Molex/DC 105 Supply,Installation, testing and commissioning of 24 port POE switch 10/100/1000. Make - Dlink/Netgear 106 Supply, Installation, testing and commissioning of Dual Band Wave Wifi 6 Access Points. Make - Grandstream/Netgear 107 Supply,Installation, testing and commissioning of cat6 Informatio0n Outlets, non PCB Pyramid type. Make - Dlink/Amp/Molex 108 Supply, Installation, testing and commissioning of Dual Face Plates with clear labeling. Make - Dlink/Amp/Molex 109 Supply, Installation, testing and commissioning of Single Face Plates with clear labeling. Make - Dlink/Amp/Molex 110 Supply, Installation, testing and commissioning of IP fixed Cameras, Network TDN IR Indoor/Outdoor Camera, 1/3 CMOS, 2 MP, 3.6 mm Fixed, 24 IR LEDs,PoE,H.264complete. Make - Dahua 111 Supply, Installation, testing and commissioning of PTZ DOME Cameras, 4MP, 2.8mm CMOS image sensor, low illuminance, 2, 12V DC/PoE power supply, Network TDN IR Indoor/Outdoor IP67 Rated tamper proof complete. Make - Dahua/Hikvision 112 FIRE ALARM WORK 113 supplying , installation , Testing & commissioning of smoke detector with builtin LED and mounting base complete with all connections etc. as required. DSR-17.1.2 114 supplying , installation , Testing & commissioning of manual call boxes of MS construction in surface/recess with strainless steel chain & hammer assembly complete with glass and push button etc. as required. DSR-17.1.3 115 supplying , installation , Testing & commissionin response indicator on surface/recess Ms box having two LEDs mettallic cover complete with all connections etc. as required.DSR-17.1.5 116 supplying , installation , Testing & commissionin fire alarm sounder with facility to make announcement, mounted in M.S. box (16 SWG) with hinged cover plate & suitable for operation with amplifier i/c line matching trasformer etc. complete as required. DSR-17.1.6 117 supplying , installation , Testing & commissionin of main control and indicating panel made out of 16 SWG MS sheet to accommodete the following items duly powder coated in approved colour with louvers for ventilation, locking arrangement, audio and visual indication for fire alarm and public adress system, monitoring system including connections, interconnections etc complete as required. 6 zone panel for fire alarm system 100 watt amplifier racks suitable for operation on 230V AC/24V DC supply conforming to IEC-268-3 complete with all talk back master station with LED PTT ( press to talk ) push buttonfor operation on 230V AC/24 V DC supply conforming to IEC-268 for simplex mode of operation/ communication suitable for 20 Nos. talk back unit-1 set. annoucement control desk suitable for selection of different zones selectively and ON ALL CALL switch with visual indication etc, complete as required-1 set Amplifier change over switch for inter changing amplifier-1 No. Monitor panel for loudspeaker complete output selector ON/OFF switch, fuse visual indications etc. complete as required -1 No. Gooseneck microphone with stand and ON/OFF switch-1 No. Mains ON/OFF switch, fuse indication lamps, DC and AC voltmeters & ammeters terminal blocks etc. complete as required-1 set. Battery charger trickle cum boost to take complete load of fire alarm PA system complete with all accessories including providing & fixing of 2 nos. 12 volt, 30 AH each sealed mainenance free batteries-1 set. DSR-17.1.11 118 supplying , installation , Testing & commissioning of fire fighter telephone handset complete as required. DSR-17.2.17 119 CABLING & WIRINGDSR-17.5 120 supplying & laying of 2* 1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required.DSR-17.5.2 121 supplying & drawing of cable fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steelconduit of following pairs, cores and size including connections and interconnections etc. as required speaker cable Two pair, 2-core , 1.5 sqmmDSR-17.5.3 122 Supplying and fixing 25 mm dia MS flexible pipe with PVC coating along with all ancillaries and accessories like coupler etc. as required DSR-17.5.4 123 Supply,Installation, Testing & Commissioning ISI marked portable type fire extinguishers of 4.5 Kg capacity CO2 type as per IS- 15683complete as per specification and fixed / install as per site condition: MR 124 Supply,Installation, Testing & Commissioning ISI marked portable type fire extinguishers of 5 Kg capacity ABC Dry Chemical powderas per IS- 15683complete as per specification and fixed / install as per site condition : MR. 125 Supply, Installation testing and commissioning of Ceiling mounted automatic fire extinguisher (Dry Chemical powder) of 10KG capacity including all fitting and accessories as per dwg and spec as complete required. MR. 126 Supply,Installation, Testing & Commissioning of 3 Nos. G.I. sand buckets painted Red Color complete with suitable size G.I. stand duly painted Red Color of suitable size to hang 3 Buckets at a time as per required specifications. MR. 127 VRV AIR-CONDITIONING WORK 128 Interconnectingrefrigerantpipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation betweeneach set ofindoor &outdoor units as perspecifications,all pipinginsidethe roomshallbe properlysupported 41.3 mmall complete as per drawing, specification and directionas approved by Engineer -in-Charge. 129 Interconnectingrefrigerantpipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation betweeneach set ofindoor &outdoor units as perspecifications,all pipinginsidethe roomshallbe properlysupported 34.9 mmall complete as per drawing, specification and directionas approved by Engineer -in-Charge. 130 Interconnectingrefrigerantpipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation betweeneach set ofindoor &outdoor units as perspecifications,all pipinginsidethe roomshallbe properlysupported 28.6 mmall complete as per drawing, specification and directionas approved by Engineer -in-Charge. 131 Interconnectingrefrigerantpipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation betweeneach set ofindoor &outdoor units as perspecifications,all pipinginsidethe roomshallbe properlysupported 22.2 mmall complete as per drawing, specification and directionas approved by Engineer -in-Charge. 132 Interconnectingrefrigerantpipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation betweeneach set ofindoor &outdoor units as perspecifications,all pipinginsidethe roomshallbe properlysupported 19.1 mmall complete as per drawing, specification and directionas approved by Engineer -in-Charge. 133 Interconnectingrefrigerantpipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation betweeneach set ofindoor &outdoor units as perspecifications,all pipinginsidethe roomshallbe properlysupported 15.9 mmall complete as per drawing, specification and directionas approved by Engineer -in-Charge. 134 Interconnectingrefrigerantpipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation betweeneach set ofindoor &outdoor units as perspecifications,all pipinginsidethe roomshallbe properlysupported 12.7 mmall complete as per drawing, specification and directionas approved by Engineer -in-Charge. 135 Interconnectingrefrigerantpipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation betweeneach set ofindoor &outdoor units as perspecifications,all pipinginsidethe roomshallbe properlysupported 9.5 mmall complete as per drawing, specification and directionas approved by Engineer -in-Charge. 136 Interconnectingrefrigerantpipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation betweeneach set ofindoor &outdoor units as perspecifications,all pipinginsidethe roomshallbe properlysupported 6.4 mmall complete as per drawing, specification and directionas approved by Engineer -in-Charge. 137 Providing & Laying of Cable tray for copper pipe 300MMall complete as per drawing, specification and directionas approved by Engineer -in-Charge. 138 Supply, Installation, testing and commissioning of Hard PVC Pipe Suitable for 10 Kg/cm2 water pressure including fittings such as elbow, socket, reducer, etc.insulated with 6 mm thick tubular nitrile insulation, 32 mm dia with 6 MM thicknessall complete as per drawing, specification and directionas approved by Engineer -in-Charge. 139 Supply, Installation, testing and commissioning of Hard PVC Pipe Suitable for 10 Kg/cm2 water pressure including fittings such as elbow, socket, reducer, etc.insulated with 6 mm thick tubular nitrile insulation, 25 mm dia with 6 MM thicknessall complete as per drawing, specification and directionas approved by Engineer -in-Charge. 140 Providing &fixing control cumtransmission wiring ofcopper in suitable conduits between indoorand out door unitall complete as per drawing, specification and directionas approved by Engineer -in-Charge. 141 Supply & Laying of M S Slotted Angle for pipes and cables horizontaly and vertically along with threaded rod, nut, bolt, saddle, tie etcall complete as per drawing, specification and directionas approved by Engineer -in-Charge. 142 Wall Chaseing as per site requirement all complete as per drawing, specification and directionas approved by Engineer -in-Charge. 143 Making Core cutting in Walls, Beams, RCC structure as per site requirement all complete as per drawing, specification and directionas approved by Engineer -in-Charge. 144 Supply, Installation, Testing & Commissioning of DAIKINBRANDVRV OUTDOOR UNIT MODEL 22 HP HEAT PUMPRXYQ12ARY6+RXYQ10ARY6+BHF22P1006 all complete as per drawing, specification and directionas approved by Engineer -in-Charge. 145 Supply, Installation, Testing & Commissioning of DAIKINBRANDVRV OUTDOOR UNIT MODEL 44HP HEAT PUMP RXYQ20ARY6+RXYQ12ARY6+BHF22P1516 all complete as per drawing, specification and directionas approved by Engineer -in-Charge. 146 Supply, Installation, Testing & Commissioning of Hi wall Type Unit- 0.66 TR + Corded Remote + Refnet, Model FXAQ20 all complete as per drawing, specification and directionas approved by Engineer -in-Charge. 147 Supply, Installation, Testing & Commissioning of Hi wall Type Unit- 0.83 TR + Corded Remote + Refnet, Model FXAQ25all complete as per drawing, specification and directionas approved by Engineer -in-Charge. 148 Supply, Installation, Testing & Commissioning of Hi wall Type Unit- 1.06 TR + Corded Remote + Refnet, Model FXAQ32all complete as per drawing, specification and directionas approved by Engineer -in-Charge. 149 Supply, Installation, Testing & Commissioning of Hi wall Type Unit- 1.32 TR + Corded Remote + Refnet, Model FXAQ40all complete as per drawing, specification and directionas approved by Engineer -in-Charge. 150 Supply, Installation, Testing & Commissioning of Hi wall Type Unit- 1.65 TR + Corded Remote + Refnet, Model FXAQ50all complete as per drawing, specification and directionas approved by Engineer -in-Charge. 151 Supply, Installation, Testing & Commissioning of Hi wall Type Unit- 2.08 TR + Corded Remote + Refnet, Model FXAQ63all complete as per drawing, specification and directionas approved by Engineer -in-Charge. 152 Supply, Installation, Testing & Commissioning of Round Flow Cassette Type Unit- 2.65TR + Corded Remote + Refnet, Model FXFSQ80all complete as per drawing, specification and directionas approved by Engineer -in-Charge. 153 Supply, Installation, Testing & Commissioning of Round Flow Cassette Type Unit- 3.31TR + Corded Remote + Refnet, Model FXFSQ100all complete as per drawing, specification and directionas approved by Engineer -in-Charge. 154 Supply, Installation, Testing & Commissioning of Round Flow Cassette Type Unit- 4.13 TR + Corded Remote + Refnet, Model-FXFSQ125all complete as per drawing, specification and directionas approved by Engineer -in-Charge. 155 One Time Lifting, shifting, positioning, installation, testing of indoor units, outdoor units, fittings (Imported Y-joints & header etc.) remote controlsof indoor units, complete as per specification and drawings, Outdoor Unitall complete as per drawing, specification and directionas approved by Engineer -in-Charge. 156 One Time Lifting, shifting, positioning, installation, testing of indoor units, outdoor units, fittings (Imported Y-joints & header etc.) remote controlsof indoor units, complete as per specification and drawings, Hi Wall Unitsall complete as per drawing, specification and directionas approved by Engineer -in-Charge. 157 One Time Lifting, shifting, positioning, installation, testing of indoor units, outdoor units, fittings (Imported Y-joints & header etc.) remote controlsof indoor units, complete as per specification and drawings, Cassette Type Unitsall complete as per drawing, specification and directionas approved by Engineer -in-Charge. 158 Commissioning of VRV systems including topping R410A gas per site requirementsall complete as per drawing, specification and directionas approved by Engineer -in-Charge. 159 DRIVEWAY WORK 160 Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge.DSR-(16.83) 161 Laying old cement cocrete interlocking paver blocks of any design/ shape laid in required line, level, curvature, colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. (Old CC paver blocks shall be supplied by the department free of cost). DSR-(16.84) 162 Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 60mm thick cement concrete paver block of M-35 grade with approved colour, design & pattern. DSR-(16.91) 163 Providing and laying in position cement concrete of specified gradeexcluding the cost of centering and shuttering - All work up to plinthlevel :1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size) DSR - 4.1.8 164 Providing & Layingof 15 mm thickHeavy duty Exterior floor tiles of approved Brand and sample in size 600 x 600 mm which will be cutted in different sizes as per app. design with 3 to 6 mm spacer offirst quality of Bell, Johnson, Kajaria or equal make, shade, colour, and pattern as app. by engineer Incharge laid over base cement mortar 1:4 mix including finishing the joint with white cementand to make the joint as perthe approved design, drawing and specification and direction of EI. MR 165 Grouting the joints of flooring tiles having joints using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge.DSR(11.48.2) 166 FURNITURE ESTIMATE 167 Providing, Making & Fixing of Executive Wooden Court Room Dais of Size (3000Lx1200Wx750HT) MM Made of 2 Layers of 19MM Board with All Edges to be Lipped with Teak Wood Beading & All Outside Exposed Surface To Be Finished With 4MM Veneer which shall be Melamine Polished & Inner Side To Be Finished with 1MM Laminate, Complete In All Respect As Per Drawing, Specification Approved By Architect/ Engineer In Charge. Customized 168 Table of Size - 1950W X 900D X 750HT Having Side Storage of - 900W X 450D X 750HT & Back Storage of - 1500W X 450D X 750HT & 450 Extended Top Specifications Table Top: 25mm thick Pre laminate particle board with 2mm PVC edge Lipping on all exposed edges (Straight/Reverse waterfall edge) Support: End Legs : Powder coated Al die casted Enrich legs Modesty Panel: 18mm thk pre lam board with 2mm PVC edge lipping of 450mm Ht. Wire Management: 450mm Aluminium Flip Up and provision to mount swicthes and sockets on PVC cable dump and Vertical wire entry cover or vertebra for wire uptake from floor to cable dump The storage will be made in 18 MM PLB (Pre laminated board) with the density of 680kg/m³ and 18 mm thick one side pre-laminate board confirming to IS 12406 : 2013. Surface: CPL (continuous pressure laminate) in 0.5mm thickness in melamine finish. The PLB will be confirming to E-1 Grade as per the JIS A 5905-2003 standards and approved shade confirming to IS-12823:1990.The back of storage will be made in 9 MM PLB (Pre laminated board) with the density of 680kg/m³ and 18 mm thick one side pre-laminate board confirming to IS 12406 : 2013. Surface: CPL ( continuous pressure laminate) in 0.5mm thickness in melamine finish. Storgage will be provided with edge banding 2 mm thick PVC edge band will confirm to DIN 68861 for resistance to clearers. The Hot melt glue used for fixing the PVC edge band should have ISO 9001- 2015 quality certification and confirm to ASTM D 4499 standards for viscosity and thermal stability. The edge band material should have Shore D hardness of 79± 4. storage will have two adjustable shelves, Make-Featherlite/Geeken/Hof/Equivalent 169 Table of Size - 1800W X 900D X 750HT Having Side Storage of - 900W X 450D X 750HT & Back Storage of - 1350W X 450D X 750HT & 450 Extended Top Specifications Table Top: 25mm thick Pre laminate particle board with 2mm PVC edge Lipping on all exposed edges (Straight/Reverse waterfall edge) Support: End Legs : Powder coated Al die casted Enrich legs Modesty Panel: 18mm thk pre lam board with 2mm PVC edge lipping of 450mm Ht. Wire Management: 450mm Aluminium Flip Up and provision to mount swicthes and sockets on PVC cable dump and Vertical wire entry cover or vertebra for wire uptake from floor to cable dump The storage will be made in 18 MM PLB (Pre laminated board) with the density of 680kg/m³ and 18 mm thick one side pre-laminate board confirming to IS 12406 : 2013. Surface: CPL (continuous pressure laminate) in 0.5mm thickness in melamine finish. The PLB will be confirming to E-1 Grade as per the JIS A 5905-2003 standards and approved shade confirming to IS-12823:1990.The back of storage will be made in 9 MM PLB (Pre laminated board) with the density of 680kg/m³ and 18 mm thick one side pre-laminate board confirming to IS 12406 : 2013. Surface: CPL ( continuous pressure laminate) in 0.5mm thickness in melamine finish. Storgage will be provided with edge banding 2 mm thick PVC edge band will confirm to DIN 68861 for resistance to clearers. The Hot melt glue used for fixing the PVC edge band should have ISO 9001- 2015 quality certification and confirm to ASTM D 4499 standards for viscosity and thermal stability. The edge band material should have Shore D hardness of 79± 4. storage will have two adjustable shelves, Make-Featherlite/Geeken/Hof/Equivalent 170 Table of Size - 1500W X 750D X 750HT Having Side Storage of - 900W X 450D X 750HT. The main table shall be made of 25mm thick PLB one side pre-laminate board confirming to IS-14587:1998. Soft closing access flap with in-built power box to be provided on work surface for wire management. Return table Work Surface should be made of 25mm thick PLB one side pre-laminate board confirming to IS-14587:1998. PLB will be E1-P2 grade and approved shade. Confirming to IS-12823:1990. 2 mm thick PVC edge band will confirm to DIN 68861 for resistance to clearers. The edge band material should have Shore D hardness of 79± 4. The Hot melt glue used for fixing the PVC edge band should have ISO 9001- 2015 quality certification confirming to ASTM D 4499 standards for viscosity and thermal stability. The edges should be PVC Edge banded with matching finish or have an option of reverse water fall edges.Modesty Panel shall be made of 18mm thick PLT both sides pre-laminate board confirming to IS-14587:1998.The height of modesty shall be 450 mm.The modesty panel will be connected to the main table by 2 nos special Aluminum extruded brackets. The modesty will be fixed 150 mm from the edge of the table. • Cable management: The table will be provided with suitable grommet hole. Legs and Supports:- The MS supports are made of 55 x55mm diamond shape loop leg ERW tubes- 16g with levelers to cater for floor undulations- +/- 20 mm. ERW Tube confirming to IS 4923 : 1997 – 16g. Main leg members will be connected through a horizontal member size 1.6mm thk, 60x40 cold formed ERW tube confirming to IS 4923: 1997. The vertical and the horizontal tubes will be welded with CO2 MIG welding process confirming to IS 816 and ISO 9692-2. The leg will be fabricated using Argon & Co2 gas mixture on a Robotic welding machine to ensure adequate welding strength with consistency.• The legs will be connected with Cross beams to take care of the bending stress catering up to 1800 mm length and up to 900 mm depth of the work surface. Finish:- All metal components & aluminum die cast parts will be powder coated by Nano ceramic surface treatment process compiled to a Bend test-ASTM D3451 – 06, Adhesion -DIN EN 14901 Salt spray test- DIN EN ISO 9227, which is non-hazardous, environmental friendly and will have uniform powder coating thickness of 50-60-micron thickness.Wire Management: Make-Featherlite/Geeken/Hof/Equivalent 171 Providing, Making & Fixing of Wooden Table of Size (1350Lx675Wx750HT) MM Made of 2 Layers of 19MM Board with All Edges to be Lipped with Teak Wood Beading & All Outside Exposed Surface To Be Finished With 4MM Veneer which shall be Melamine Polished & Inner Side To Be Finished with 1MM Laminate, Complete In All Respect As Per Drawing, Specification Approved By Architect/ Engineer In Charge. Customized 172 Providing, Making & Fixing of Wooden Linear Workstation Table Having Keyboard Tray & Cable Manager Made of 1 Layers of 19MM Board with All Edges to be Lipped with Teak Wood Beading & All Outside Exposed Surface To Be Finished With 1MM Laminate, Complete In All Respect As Per Drawing, Specification Approved By Architect/ Engineer In Charge. Customized 173 Liner Workstation of Size:- 1350W X 600D X 750HT AND 300HT HEIGHT Specifications: Table Top - 25mm thick Pre Lam particle board with 2mm edge lipping on all exposed sides. Support - MS powder coated diamond shape leg of 55X55mm size with die cast connectors and supporting MS cross beams. Main Screen:- Aluminum anodised 30mm scree n with fabric magnetic and glass marker tiles. Privacy Screen:- 6mm thick acrylic screen on studs. Wiremanagement - 450mm metal flip up with provision to mount switches and sockets on MS cable tray and vertical wire entry cover between the intermeidate leg for power and data. Model - MAX-1 Make-Featherlite/Geeken/Hof/Equivalent 174 Providing, Making & Fixing of Wooden Linear Printer Table,Made of 1 Layers of 19MM Board with All Edges to be Lipped with Teak Wood Beading & All Outside Exposed Surface To Be Finished With 1MM Laminate, Complete In All Respect As Per Drawing, Specification Approved By Architect/ Engineer In Charge. Customized. 175 Providing And Fixing of Confference Table Made 0f 19MM thick ply board,Top in 3 layers and virtical drop 3 Lair 19MM ply board. All the surface to be cladded with 4MM thick Veener And S.S Fram square section 302 grad frame. All the edges to be lipped with 4MM Veneer polished in matching colour.As per the design. as per E/I. (Greenply/Luxe or Equivalent ISI Make) Customized 176 Providing, Making & Fixing of Wooden Witness Box of Encloser Size (1050Lx900Dx1050HT) MM Made of 2 Layers of 19MM Board with All Edges to be Lipped with Teak Wood Beading & All Outside Exposed Surface To Be Finished With 4MM Veneer which shall be Melamine Polished & Inner Side To Be Finished with 1MM Laminate, Complete In All Respect As Per Drawing, Specification Approved By Architect/ Engineer In Charge. Customized 177 Providing, Making & Fixing of Back Storage of Size (3000Lx450Wx700HT) Made of 2 Layers of 19MM Board with All Edges to be Lipped with Teak Wood Beading & All Outside Exposed Surface To Be Finished With 4MM Veneer which shall be Melamine Polished & Inner Side To Be Finished with 1MM Laminate, Complete In All Respect As Per Drawing, Specification Approved By Architect/ Engineer In Charge.Customized 178 Providing, Making & Fixing of Back Storage of Size (1800Lx450Wx700HT) Made of 2 Layers of 19MM Board with All Edges to be Lipped with Teak Wood Beading & All Outside Exposed Surface To Be Finished With 4MM Veneer which shall be Melamine Polished & Inner Side To Be Finished with 1MM Laminate, Complete In All Respect As Per Drawing, Specification Approved By Architect/ Engineer In Charge. Customized 179 Providing & Fixing of Wooden Storage, Particle Board Structure, (1500x450x900), Model-Storage-9, Make-Geeken, all complete as per design approved by E/I & Architect Incharge. 180 Side Storage of Size 900Wx450Dx750HT will be made in 18 MM PLB (Pre laminated board) with the density of 680kg/m³ and 18 mm thick one side pre-laminate board confirming to IS 12406 : 2013. Surface: CPL ( continuous pressure laminate) in 0.5mm thickness in melamine finish. The PLB will be confirming to E-1 Grade as per the JIS A 5905-2003 standards and approved shade confirming to IS-12823:1990.The back of storage will be made in 9 MM PLB (Pre laminated board) with the density of 680kg/m³ and 18 mm thick one side pre-laminate board confirming to IS 12406 : 2013. Surface: CPL ( continuous pressure laminate) in 0.5mm thickness in melamine finish. Storgage will be provided with edge banding 2 mm thick PVC edge band will confirm to DIN 68861 for resistance to clearers. The Hot melt glue used for fixing the PVC edge band should have ISO 9001- 2015 quality certification and confirm to ASTM D 4499 standards for viscosity and thermal stability. The edge band material should have Shore D hardness of 79± 4. storage will have two adjustable shelves making 3 compartments.The shutters are fitted with auto closing hinges.Central locking system , levellers & other necessary hardware are priovided.Handles will be hand grooved, Make-Featherlite/Geeken Equivalent. 181 Providing, Making & Fixing of TV Pannel of Size (2100Lx450Wx750HT) Made of 2 Layers of 19MM Board with All Edges to be Lipped with Teak Wood Beading & All Outside Exposed Surface To Be Finished With 4MM Veneer which shall be Melamine Polished & Inner Side To Be Finished with 1MM Laminate, Complete In All Respect As Per Drawing, Specification Approved By Architect/ Engineer In Charge. Customized 182 High Back Chairs Seat and back is made out of 12mm molded hot pressed plywood in ergonomic shape fitted with Imported T-nuts and revited in to the wood.Gaslift - Class 4 tested -ANSI BIFMA performance standards.Castors - Twin Castors 50mm dia castors compling to ANSI / BIFMA X 5.1 – 2002.The 640mm dia (26 inches) five pronged base is made out of GF nylon – Reinforced with bottom ribbing for additional buttress and strength.Tested prudently and rigorously as per ANSI/BIFMA X5.1-2011 General Purpose Office Chair Standards.Upholstery: Seat Cushion with pre moulded foam having leatherette tapestery of 50 - 60 density Density -- 52 kg/m3 Hardness -- 12.6kgf at 25%.Distinctively and characteristically designed tilt mechanism offering a very smooth and fluidic reclining motion with tension adjust knob and importantly offering seat to back recline ratio of 3:7, optimal for good back support.Multilock mechanism is fabricated from CR Sheets, undergo through CO2 welding process imparting uniform surface finish and tensile strength. The components are processed with high degree of precision and care so as to assemble with other parts in perfect harmony to give smooth and effortless reclining experience. Tension springs are made out Grade II material conforming to Indian Standards. Also provided with release levers for locking mechanism and height adjustment of seat. Mechanism aides to operate the height adjustment, and has been equipped with 3 locking positions, back rest “ Return Prevention” function. Back Frame is inserted with leathertte tapestery cushion & Adjustable Lumbar Support.Tension control is below the Seat.Moulded polyurethene Arms confirming to IS 7078 with steel inserts for long Moulded self skinned polyurethene Arms confirming to IS 7078 with steel insets for long life. one way adjustable - Height Adjustable.Seat is duly upholstered with approved fabric. Chair will have adjustable headrestChair Should be BIFMA Certified.Seat: Depth- 51.5 cm Width- 44.5 cm Dimensions: Width- 51.5 cm Depth- 53.5 cm Minimum Height- 99.5 cm Maximum Height- 108.5 cm Minimum Seat Height- 44.5 cm Maximum Seat Height- 52.5 cm Width (Arm to Arm)- 66 MODEL, Chair should be BIFMA and Green Guard certified.:- AMAZE HB,Make-Featherlite/Geeken/Hof/Equivalent Model-GA 5003 all complete as per design approved by E/I & Architect I 183 Medium Back chair Having Base: Nylon Base- The 640mm dia (26 inches) five pronged base is made out of GF nylon – Reinforced with bottom ribbing for additional buttress and strength. Tested prudently and confirming to ANSI/BIFMA X5.1-2011 General Purpose Office Chair Standards. The base shall be 67 cm pitch-center diameter -77 cm with castors. MS ring will be insert molded for better grip in the swaged taper. Castors: Twin Castors 50mm dia complying to ANSI / BIFMA X 5.1 – 2002. Castors will be made in PP.The axle pin will be rust protected- Zinc pacified. The pin should be designed to have push fit with lock ring. RoHS compliant castors. Gas lift: Standard Gas lift 100 mm stroke with pneumatic height adjustment as per the seat height criteria.- Class 4 as per ANSI BIFMA performance standards. Possibility to increase the seat height if required with Gas lift stroke- 110 -125 mm. Mechanism:Centre Tilt Mechanism:compact and stable with 8″ x 6″ mount holes as per European Standard. Initial seat angle of 3 degrees and full recline angle of 20 degrees for ergonomic comfort. Provided with common leverfor locking and up/down adjustment and horizontal movement of the lever to engage and disengage lock at upright positionLever provided for rotational movementto operate gas lift and adjust chair height to user specification. Full length plastic knob provided to cover lever bar giving better aesthetical appeal to the mechanism. Knob provided to adjust spring tension to suit individual user in order to ensure maximum chair comfort. Arms:Fixed Arms Injected molded arms- polyurethane 20% GF nylon. The polypropylene arms will have steel inserts. The arm profile should blend with the back profile without gap. Seat: Seat Height- 450-540mm with hydraulic height adjustability of 90-100mm. Seat Width & Height- Size of the chair shall be -Back: 45.0cm. (w) x 59.0cm.(H) .Seat: 48.0cm (w) X 49.0cm.(D). Chair back should be connected to the Polyurethane arms for achieving comfortable seating posture.Effective back height from Seat - 560mm, Ply wood- 12 mm thick with 7 ply. Fire retardant type exterior grade phenol formaldehyde bonded. It will be hot pressed ply - conforming to I.S.I. 5509. The arm and back shall be fixed together to the seat with Allen bolts.The bolts will be screwed to the “T” nuts fixed to the plywood seat.Fabric: Upholstery:Seat & Back are duly upholstered with approved fabric. The back should have the option of mesh back AN-70 (black) and AN-75(grey). GSM for mesh 340. No flaming or progressive smolderingwithin one hour of placement of the cigarettes. Fire rated fabric confirming to BSEN 1021 and IS 15061-2012 Foam: Seat cushion with pre molded foam of 50 - 60 density in the shape of plywood.Density -- 52 kg/m3, Hardness -- 12.6kgf at 25%- Back cushion- density- 32g/sq in. Back:Mesh back on injected molded PP with 30% GF nylon. The back should have the option of mesh or fabric back. The mesh will be GSM 340 grade. . ALPHA MB, Make-Featherlite/Geeken Equivalent. 184 Fixed Leg Chair Made of The frame is made out of 25.4mm tube of 16 gauge tube confirming to IS-7138-1973, Welded by Co2 welding process for uniform surface finish and higher tensile strength perforation on the sheet is of uniform 2.5mm dimension and gives good ventilation.High quality hardware conforming to Hardness 38-44 and tensile strength – 1300 n/mm. IS 1363-1967.Seat is made out of 12mm molded hot pressed plywood in ergonomic shape fitted with Japanese T-nuts and riveted in to the plywood.Set and backUpholstery: Cushion with pre-moulded foam of 50 - 60kg/m3 density in the shape of plywood. Density -- 52 kg/m3 Hardness -- 12.6kgf at 25%.Injection moulded polypropylene armrests.Leatherette cusion Back on Frame. Back is injected moulded PP.Seat and back are duly upholstered with approved Leatherette. AMAZE VA, Make-Featherlite/Geeken/Hof/Equivalent 185 Providing & Fixing of 3 Seater Sofa, Aluminium Arm And Leg, Powder Coated Cross Beam, Metal Insert PU Seat Back Size in mm - 1625(L) X660(D) X 870(H) Having 3 Seater With 4 Arm, Model-Fly-2, Make-Featherlite/Geeken/Hof/Equivalent, all complete as per design approved by E/I & Architect Incharge. 186 Providing, Making & Fixing of High Back Chair As per Design Approved made of teak wood having high density foam of sleepwell brand, upholstered in approved fabric/leatherrete. Wooden part to be finished in melamine polish, Complete In All Respect As Per Drawing, Specification Approved By Architect/ Engineer In Charge.Customized 187 GUARD-1 ROOM WORK 188 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil , DSR-2.8.1 189 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinthlevel :1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size) DSR-4.1.8 190 Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 8 kms. from the site of work and including watering, dressing etc rate to include cost of all materials labour T & P etc required for proper completion of work. DSR-2.27 191 Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion):1).Along external wall where the apron is not provided using chemical emulsion @ 7.5 litres / sqm of the vertical surface of the substructure to a depth of300mm including excavation channel along the wall & rodding etc. complete: 2).Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. 3).Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor. 4).Treatment of existing masonry using chemical emulsion@ one litre per hole at 300mm interval includingdrilling holes at 45 degree and plugging them withcement mortar 1:2(1 cement : 2 coarse sand) to the full depth of the hole. 5).Treatment at points of contact of wood work by chemical emulsion Chlorpyriphos/Lindane(in oil or kerosene based solution) @ 0.5 litres per hole by drilling 6 mm dia holes at downwardangle of 45degree at 150mm centre to centre and sealingthe same.All with With chlorpyriphos/Lindane E.C. 20% with 1% concentration. DSR-2.35.1+2.35.2+2.35.3+2.35.3+2.35.4+2.35.5 192 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland/Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All works upto plinth level, Concrete of M25 grade with minimum cement content of 330 kg /cum.Concrete of M25 grade with minimum cement contect of 300 kg/cum (For Foundation) DSR-5.33.1.1 193 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland/Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All works above plinth level,Concrete of M25 grade with minimum cement content of 330 kg /cum (For Column) DSR-5.33.2.1 194 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland/Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All works above plinth level,Concrete of M25 grade with minimum cement content of 330 kg /cum (For Beam) DSR-5.33.2.1 195 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland/Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All works above plinth level,Concrete of M25 grade with minimum cement content of 330 kg /cum (For Slab) DSR-5.33.2.1 196 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland/Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All works above plinth level,Concrete of M25 grade with minimum cement content of 330 kg /cum (For Lintel) DSR-5.33.2.1 197 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement: 4 coarse sand) D.S.R.-6.1.1 198 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement: 4 coarse sand) D.S.R.-6.4.1 199 Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources: 4 graded stone aggregate 12.5mm nominal size derived from natural sources) D.S.R.-4.10 200 Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approv quality using 1.7 kg per square metre on damp proof course after cleaning the surface w brushes and finally with a piece of cloth lightly soaked in kerosene oil. D.S.R.-4.13 201 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level and above plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more DSR-5.22.6 202 12 mm Cement plaster of mix.1:4 (1 cement: 4 course sand) DSR-13.4.1 203 15 mm cement plaster in single coat on rough side of single or half brick wall 1:4 (1 cement: 4 course sand) DSR-13.5.1 204 Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:(a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement: 5 coarse sand) admixed with water proofing compound conforming to IS: 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1) cement :5 coarse sand) admixed with water proofing compound conforming to IS: 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS: 2645 and approved by Engineer-in-charge.(d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement 4 coarse sand) admixed with water proofing compound conforming to IS: 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deepThe whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-ChargeWith average thickness of 120 mm and minimum thickness at khurra as 65 mm DSR-22.7 205 Centering and shuttering including strutting, propping etc. and removal of form work for:Foundations, footings, bases for columns. DSR-5.9.1 206 Centering and shuttering including strutting, propping etc. and removal of form work for:Suspended floors, roofs, landings, balconies and access platform. DSR-5.9.3 207 Centering and shuttering including strutting, propping etc. and removal of form work for:Lintels, beams, plinth beams, girders, bressumers and cantilevers. DSR-5.9.5 208 Centering and shuttering including strutting, propping etc. and removal of form work for:Columns, piers, abutments, pillars, posts and struts. DSR-5.9.6 209 Supply&Fixingofwindowsmadefrommulti chambered UPVC profiles of minimum 60/108 mm thicknessof (Wintechmakeorequivalent)in natural from stailized for heat, light, impact & UV radiation. The UPVC profiles should be reinforced withgalzvanizedsteelprofilesofdesigned thickness.Floatglassofapprovedcolourin 4/5/6/8 mm or as desired by the costumer shall be fixed with heveled beads. All openable / sliding sashes shall be having grey/black colored weather seal fitted in continuous lenghts made from bubble PTV Rubber & side Hung with 90L openin friction syats of rust proof stainless steel with provision of multipoint lockng system (casement only) made from Espag rods (coated steel) all handle shall be made from die Cast zinc alloy in white finish only as per desigh, drawings, specification & as approved by Architect/Engineer Incharge. MR 210 GUARD-2 ROOM WORK 211 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil , DSR-2.8.1 212 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinthlevel :1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size) DSR-4.1.8 213 Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 8 kms. from the site of work and including watering, dressing etc rate to include cost of all materials labour T & P etc required for proper completion of work. DSR-2.27 214 Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion):1).Along external wall where the apron is not provided using chemical emulsion @ 7.5 litres / sqm of the vertical surface of the substructure to a depth of300mm including excavation channel along the wall & rodding etc. complete: 2).Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. 3).Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor. 4).Treatment of existing masonry using chemical emulsion@ one litre per hole at 300mm interval includingdrilling holes at 45 degree and plugging them withcement mortar 1:2(1 cement : 2 coarse sand) to the full depth of the hole. 5).Treatment at points of contact of wood work by chemical emulsion Chlorpyriphos/Lindane(in oil or kerosene based solution) @ 0.5 litres per hole by drilling 6 mm dia holes at downwardangle of 45degree at 150mm centre to centre and sealingthe same.All with With chlorpyriphos/Lindane E.C. 20% with 1% concentration. DSR-2.35.1+2.35.2+2.35.3+2.35.3+2.35.4+2.35.5 215 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland/Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All works upto plinth level, Concrete of M25 grade with minimum cement content of 330 kg /cum.Concrete of M25 grade with minimum cement contect of 300 kg/cum (For Foundation) DSR-5.33.1.1 216 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland/Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All works above plinth level,Concrete of M25 grade with minimum cement content of 330 kg /cum (For Column) DSR-5.33.2.1 217 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland/Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All works above plinth level,Concrete of M25 grade with minimum cement content of 330 kg /cum (For Beam) DSR-5.33.2.1 218 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland/Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All works above plinth level,Concrete of M25 grade with minimum cement content of 330 kg /cum (For Slab) DSR-5.33.2.1 219 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland/Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All works above plinth level,Concrete of M25 grade with minimum cement content of 330 kg /cum (For Lintel) DSR-5.33.2.1 220 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement: 4 coarse sand) D.S.R.-6.1.1 221 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement: 4 coarse sand) D.S.R.-6.4.1 222 Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources: 4 graded stone aggregate 12.5mm nominal size derived from natural sources) D.S.R.-4.10 223 Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approv quality using 1.7 kg per square metre on damp proof course after cleaning the surface w brushes and finally with a piece of cloth lightly soaked in kerosene oil. D.S.R.-4.13 224 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level and above plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more DSR-5.22.6 225 12 mm Cement plaster of mix.1:4 (1 cement: 4 course sand) DSR-13.4.1 226 15 mm cement plaster in single coat on rough side of single or half brick wall 1:4 (1 cement: 4 course sand) DSR-13.5.1 227 Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:(a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement: 5 coarse sand) admixed with water proofing compound conforming to IS: 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1) cement :5 coarse sand) admixed with water proofing compound conforming to IS: 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS: 2645 and approved by Engineer-in-charge.(d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement 4 coarse sand) admixed with water proofing compound conforming to IS: 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deepThe whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-ChargeWith average thickness of 120 mm and minimum thickness at khurra as 65 mm DSR-22.7 228 Centering and shuttering including strutting, propping etc. and removal of form work for:Foundations, footings, bases for columns. DSR-5.9.1 229 Centering and shuttering including strutting, propping etc. and removal of form work for:Suspended floors, roofs, landings, balconies and access platform. DSR-5.9.3 230 Centering and shuttering including strutting, propping etc. and removal of form work for:Lintels, beams, plinth beams, girders, bressumers and cantilevers. DSR-5.9.5 231 Centering and shuttering including strutting, propping etc. and removal of form work for:Columns, piers, abutments, pillars, posts and struts. DSR-5.9.6 232 Supply&Fixingofwindowsmadefrommulti chambered UPVC profiles of minimum 60/108 mm thicknessof (Wintechmakeorequivalent)in natural from stailized for heat, light, impact & UV radiation. The UPVC profiles should be reinforced withgalzvanizedsteelprofilesofdesigned thickness.Floatglassofapprovedcolourin 4/5/6/8 mm or as desired by the costumer shall be fixed with heveled beads. All openable / sliding sashes shall be having grey/black colored weather seal fitted in continuous lenghts made from bubble PTV Rubber & side Hung with 90L openin friction syats of rust proof stainless steel with provision of multipoint lockng system (casement only) made from Espag rods (coated steel) all handle shall be made from die Cast zinc alloy in white finish only as per desigh, drawings, specification & as approved by Architect/Engineer Incharge. MR 233 LT PANNEL DG SET WORKS 234 DG Set- BACKSIDE OF THE BUILDING 235 Supply of 250 KVA DG Set Cummins/ Mahindrol 236 b DG set installation and associted works 237 LT CUM AMF PANEL - ELECTRICAL ROOM 238 Supplying, Installation, Testing and commissioning of dust, damp and vermin proof cubicle free floor, indoor type factory built sheet steel enclosed modular bolted construction extendable type LT CUM AMF Panel, suitable for operation on 415 ±10%volts, 50 Hz AC 3 phase 4 wire supply system fabricated out of suitable sized square tubular section andcoveredwith CRCA sheet steel of 2mm thick for frame work and 1.6mm covers (non load bearing), 2mm thick for gland plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade, having extensible type TPNAluminium bus bars of high conductivity, SMC bus bar supports, with bottom base channel of section not less than ISMC 75mm, fabrication shall be done in transportable sections, entire panel shall have a common G.I. earth bus bar to switch gears with required size of Alum. bus bars and inter-connectionwith solid copper conductor wires / aluminium strips, neutral links, including control wiring with 1.5 / 2.5sqmm. PVC insulated FRLS copper conductor Single Core cable, cable alleys, cable gland plates in two half, etc. necessary metering protections & indications and mounted with the following switch gears as per drawingandtechnical specifications etc. 239 INCOMER FOR TRANSFOMER4 No. 240 400A 4P 36kA MCCB,TMD Release,Type: EasyPact CVS SCHNEIDER/ABB/L&T 1 No. 241 Standard extended rotary handle for EasyPact CVS 400/630A SCHNEIDER/ABB/L&T 1 No. 242 Spreader Links (Set of 4) 4P for EasyPact CVS 400A SCHNEIDER/ABB/L&T 2 No. 243 Red Indicating Lamp 22.5mm with Integrated LED, Voltage: 240V AC C&S/VAISHNO 1 No. 244 Yellow Indicating Lamp 22.5mm with Integrated LED, Voltage: 240V AC C&S/VAISHNO 1 No. 245 Blue Indicating Lamp 22.5mm with Integrated LED, Voltage: 240V AC C&S/VAISHNO 1 No. 246 6A 1P 10kA C-Curve MCB,Type: K60H SCHNEIDER/ABB/L&T 1 No. 247 INCOMER FOR DG1 No. 248 400A 4P 36kA MCCB,TMD Release,Type: EasyPact CVS SCHNEIDER/ABB/L&T 1 No. 249 Standard extended rotary handle for EasyPact CVS 400/630A SCHNEIDER/ABB/L&T 1 No. 250 Spreader Links (Set of 4) 4P for EasyPact CVS 400A SCHNEIDER/ABB/L&T 2 No. 251 Multifunction Meter-Load Manager with RS485 port, Parameters: V, A, F, PF, W/VA, Wh /VAh, Runhrs, Onhrs & Interupts & Suppression Current (5 to 99 mA), Acc. Cl: 1.0, 3Ph, Operating voltage: 80 to 480V AC, Size: 96X96, Model: EM6436H CONZERV/SECURE 1 No. 252 400/5A Acc.Cl: 1 10VA Resin Cast Ring Type Current Transformer, Round Dia: 55mm PROCOM 1 No. 253 Red Indicating Lamp 22.5mm with Integrated LED, Voltage: 240V AC C&S/VAISHNO 1 No. 254 Yellow Indicating Lamp 22.5mm with Integrated LED, Voltage: 240V AC C&S/VAISHNO 2 No. 255 Blue Indicating Lamp 22.5mm with Integrated LED, Voltage: 240V AC C&S/VAISHNO 1 No. 256 6A 1P 10kA C-Curve MCB,Type: K60H SCHNEIDER/ABB/L&T 1 No. 257 SERVO BY-PASS ARRANGEMENT2 No. 258 400A 4P Front operated By-pass Switch with External Handle, bridging bars & Interphase Barrier, Type: SIRCOVER BYPASS SOCOMEC/C&S/HPL 1 No. 259 CHANGE OVER SECTION FOR PHASE CORRECTION2 No. 260 400A 4P ATS with bridging bars,Type: ATyS r SOCOMEC/C&S/HPL 1 No. 261 6A 1P 2Way Local - Remote/ Auto-Manual Switch with Center OFF, 60 Deg. Operation1 No. 262 Red Indicating Lamp 22.5mm with Integrated LED, Voltage: 240V AC C&S/VAISHNO 1 No. 263 6A 1P 10kA C-Curve MCB,Type: K60H SCHNEIDER/ABB/L&T 1 No. 264 Phase Sequence Relay, 3Ph-3W, Protection: Phase failure, Phase sequence, Phase asymmetry, DIN rail mount, 1C/O, Supply Voltage: 154V-500V AC (L-L), Model: 800PSR1 No. 265 14 PIN MINIATURE RELAY WITH BASE 230V AC 1 No. 266 AMF LOGIC WITH CONTROL MCBs1 No. 267 6A 1P 10kA C-Curve MCB,Type: K60H SCHNEIDER/ABB/L&T 9 No. 268 10A 1P 10kA C-Curve MCB,Type: K60H SCHNEIDER/ABB/L&T 1 No. 269 10A 2P 10kA C-Curve MCB,Type: K60H SCHNEIDER/ABB/L&T 1 No. 270 On Delay / Interval Timer, Time Range: 3 Sec to 60 Mins, 2 C/O, Voltage: 20 to 240V AC & 12to 240V DC, Type: 800XA3 No. 271 Digital Voltage Protection Relay, 3Ph-3W/ 3Ph-4W, Protection: Under / Over voltage, Phase failure, Phase sequence, Phase asymmetry, Under / Over frequency, Neutral loss, 2 x 1C/O, Supply Voltage: Self powered, Model: 900VPR2 No. 272 14 PIN MNIATURE RELAY WITH BASE 3 No. 273 Red Indicating Lamp 22.5mm with Integrated LED, Voltage: 240V AC C&S/VAISHNO 2 No. 274 Yellow Indicating Lamp 22.5mm with Integrated LED, Voltage: 240V AC C&S/VAISHNO 1 No. 275 Blue Indicating Lamp 22.5mm with Integrated LED, Voltage: 240V AC C&S/VAISHNO 1 No. 276 Green Indicating Lamp 22.5mm with Integrated LED, Voltage: 12V AC/DC C&S/VAISHNO 2 No. 277 Green Indicating Lamp 22.5mm with Integrated LED, Voltage: 12V AC/DC C&S/VAISHNO 2 No. 278 Red Indicating Lamp 22.5mm with Integrated LED, Voltage: 12V AC/DC C&S/VAISHNO 1 No. 279 Green 22.5mm Flush Type Spring Return Non-Illuminated (Metallic) Push Button, Contacts: 1NO C&S/VAISHNO 1 No. 280 Red 22.5mm Flush Type Spring Return Non-Illuminated (Metallic) Push Button, Contacts: 1NC C&S/VAISHNO 2 No. 281 6A 1P 2Way Local - Remote/ Auto-Manual Switch with Center OFF, 60 Deg. Operation1 No. 282 12 ,10A BATTERY CHANGER1 No. 283 EMARGENCY 284 BUSCOUPLER1 No. 285 400A 4P 36kA MCCB,TMD Release,Type: EasyPact CVS SCHNEIDER/ABB/L&T 1 No. 286 Standard extended rotary handle for EasyPact CVS 400/630A SCHNEIDER/ABB/L&T 1 No. 287 Spreader Links (Set of 4) 4P for EasyPact CVS 400A SCHNEIDER/ABB/L&T 2 No. 288 AC3: 250A AC1: 300A 3P Power Contactor, Coil: 220V AC, Type: LC1E SCHNEIDER/ABB/L&T 1 No. 289 Auxiliary Contact Block, Front Mounting, Contacts: 1NO+1NC for LC1E06-E630/LC1E0600-LC1E9500 SCHNEIDER/ABB/L&T 1 No. 290 Red Indicating Lamp 22.5mm with Integrated LED, Voltage: 240V AC C&S/VAISHNO 1 No. 291 Yellow Indicating Lamp 22.5mm with Integrated LED, Voltage: 240V AC C&S/VAISHNO 1 No. 292 Blue Indicating Lamp 22.5mm with Integrated LED, Voltage: 240V AC C&S/VAISHNO 1 No. 293 Red Indicating Lamp 22.5mm with Integrated LED, Voltage: 240V AC C&S/VAISHNO 1 No. 294 Green Indicating Lamp 22.5mm with Integrated LED, Voltage: 220V DC C&S/VAISHNO 1 No. 295 6A 1P 10kA C-Curve MCB,Type: K60H SCHNEIDER/ABB/L&T 5 No. 296 BUS BAR No. 297 400A TPN, 50KA aluminium bus bar with coloured heat shrinkable insulated sleeve. No. 298 Outgoing 299 OUT GOING 250A MCCB1 No. 300 250A 4P 36kA MCCB,TMD Release,Type: EasyPact CVS SCHNEIDER/ABB/L&T 4 No. 301 Standard extended rotary handle for EasyPact CVS 100/160/250A SCHNEIDER/ABB/L&T 4 No. 302 Spreader Links (Set of 4) 4P for EasyPact CVS 160/250A SCHNEIDER/ABB/L&T 8 No. 303 VAF, PF Meter, Acc. Cl: 1.0, Model: DM6100 CONZERV/SECURE 1 No. 304 250/5A Acc.Cl: 1 10VA Resin Cast Ring Type Current Transformer, Round Dia: 45mm PROCOM 1 No. 305 Red Indicating Lamp 22.5mm with Integrated LED, Voltage: 240V AC C&S/VAISHNO 2 No. 306 Yellow Indicating Lamp 22.5mm with Integrated LED, Voltage: 240V AC C&S/VAISHNO 1 No. 307 Blue Indicating Lamp 22.5mm with Integrated LED, Voltage: 240V AC C&S/VAISHNO 1 No. 308 6A 1P 10kA C-Curve MCB,Type: K60H SCHNEIDER/ABB/L&T 2 No. 309 OUT GOING 200A FP MCCB2 No. 310 200A 4P 36kA MCCB,TMD Release,Type: EasyPact CVS1 No. 311 Standard extended rotary handle for EasyPact CVS 100/160/250A1 No. 312 Spreader Links (Set of 4) 4P for EasyPact CVS 160/250A2 No. 313 OUT GOING 160A FP MCCB6 No. 314 160A 4P 36kA MCCB,TMD Release,Type: EasyPact CVS SCHNEIDER/ABB/L&T 1 No. 315 Standard extended rotary handle for EasyPact CVS 100/160/250A SCHNEIDER/ABB/L&T 1 No. 316 Spreader Links (Set of 4) 4P for EasyPact CVS 160/250A SCHNEIDER/ABB/L&T 2 No. 317 OUT GOING 100A FP MCCB2 No. 318 100A 4P 25kA MCCB,TMD Release,Type: EasyPact CVS SCHNEIDER/ABB/L&T 1 No. 319 Standard extended rotary handle for EasyPact CVS 100/160/250A SCHNEIDER/ABB/L&T 1 No. 320 Spreader Links (Set of 4) 4P for EasyPact CVS 100A SCHNEIDER/ABB/L&T 2 No. 321 OUT GOING 63A FP MCCB2 No. 322 63A 4P 10kA C-Curve MCB,Type: xC60 SCHNEIDER/ABB/L&T 2 No. 323 75KVAr APFC PANEL - ELECTICAL ROOM 324 Supplying, Installation, Testing and commissioning of dust, damp and vermin proof cubicle free floor, indoor type factory built sheet steel enclosed modular bolted construction APFC Panel, fabricated out of suitable sized square tubular section andcoveredwith CRCA sheet steel of 1.6mm thick for frame work and 1.6mm covers (non load bearing), 2mm thick for gland plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade. 325 APFC PANEL INCOMER 1 Nos. 326 200A 4P 36kA MCCB,TMD Release,Type: EasyPact CVS SCHNEIDER/ABB/L&T 1 Nos. 327 Standard extended rotary handle for EasyPact CVS 100/160/250A SCHNEIDER/ABB/L&T 2 Nos. 328 Spreader Links (Set of 4) 4P for EasyPact CVS 160/250A SCHNEIDER/ABB/L&T 1 Nos. 329 5 Steps 240V AC Power Factor Controller Relay with 3CT, 3PH-4W, Type: BR50001 Nos. 330 Multifunction Meter-Load Manager with RS485 port, Parameters: V, A, F, PF, W/VA, Wh /VAh, Runhrs, Onhrs & Interupts & Suppression Current (5 to 99 mA), Acc. Cl: 1.0, 3Ph, Operating voltage: 80 to 480V AC, Size: 96X96, Model: EM6436H CONZERV/SECURE 9 Nos. 331 200/5A Acc.Cl: 1 10VA Resin Cast Ring Type Current Transformer, Round Dia: 30mm PROCOM 1 Nos. 332 Red Indicating Lamp 22.5mm with Integrated LED, Voltage: 240V AC C&S/VAISHNO 1 Nos. 333 Yellow Indicating Lamp 22.5mm with Integrated LED, Voltage: 240V AC C&S/VAISHNO 3 Nos. 334 Blue Indicating Lamp 22.5mm with Integrated LED, Voltage: 240V AC C&S/VAISHNO 4 Nos. 335 6A 1P 10kA C-Curve MCB,Type: K60H SCHNEIDER/ABB/L&T 1 Nos. 336 CAPACITOR BANK SECTION Nos. 337 25KVAR BANK2 Nos. 338 100A 3P 25kA MCCB,TMD Release,Type: EasyPact CVS SCHNEIDER/ABB/L&T 1 Nos. 339 Spreader Links (Set of 3) 3P for EasyPact CVS 100A SCHNEIDER/ABB/L&T 2 Nos. 340 25kVAr 3Ph Heavy Duty PhiCap-Cylindrical 440V AC Capacitor EPCOS/SCHNEIDER 1 Nos. 341 AC3: 50A AC1: 80A 3P Power Contactor, Coil: 220V AC, Aux. Contact: 1NO+1NC, Type: LC1D SCHNEIDER/ABB/L&T 1 Nos. 342 Red Indicating Lamp 22.5mm with Integrated LED, Voltage: 240V AC C&S/VAISHNO 1 Nos. 343 Green Indicating Lamp 22.5mm with Integrated LED, Voltage: 220V DC C&S/VAISHNO 1 Nos. 344 6A 1P 10kA C-Curve MCB,Type: K60H SCHNEIDER/ABB/L&T 2 Nos. 345 10KVAR BANK2 Nos. 346 63A 3P 10kA C-Curve MCB,Type: K60H SCHNEIDER/ABB/L&T 1 Nos. 347 10kVAr 3Ph Normal Duty PhiCap-Cylindrical 440V AC Capacitor EPCOS/SCHNEIDER 1 Nos. 348 AC3: 25A AC1: 40A 3P Power Contactor, Coil: 220V AC, Aux. Contact: 1NO+1NC, Type: LC1D SCHNEIDER/ABB/L&T 1 Nos. 349 Red Indicating Lamp 22.5mm with Integrated LED, Voltage: 240V AC C&S/VAISHNO 1 Nos. 350 Green Indicating Lamp 22.5mm with Integrated LED, Voltage: 220V DC C&S/VAISHNO 1 Nos. 351 6A 1P 10kA C-Curve MCB,Type: K60H SCHNEIDER/ABB/L&T 2 Nos. 352 5KVAR BANK1 Nos. 353 32A 4P 10kA C-Curve MCB,Type: K60H SCHNEIDER/ABB/L&T 1 Nos. 354 5kVAr 3Ph Normal Duty PhiCap-Cylindrical 440V AC Capacitor EPCOS/SCHNEIDER 1 Nos. 355 AC3: 16A 3P Power Contactor, Coil: 220V AC, Aux. Contact: 1NC, Type: LC1K SCHNEIDER/ABB/L&T 1 Nos. 356 Red Indicating Lamp 22.5mm with Integrated LED, Voltage: 240V AC C&S/VAISHNO 1 Nos. 357 Green Indicating Lamp 22.5mm with Integrated LED, Voltage: 220V DC C&S/VAISHNO 1 Nos. 358 6A 1P 10kA C-Curve MCB,Type: K60H SCHNEIDER/ABB/L&T 2 Nos. 359 LTDB - 2 ON EVERY FLOOR 360 Supplying, Installation, Testing and commissioning of dust, damp and vermin proof cubicle free floor, indoor type factory built sheet steel enclosed modular bolted construction LTDB, fabricated out of suitable sized square tubular section andcoveredwith CRCA sheet steel of 1.6mm thick for Enclosure, 2mm thick for gland plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade. 361 160A 4P 36kA MCCB,TMD Release,Type: EasyPact CVS 362 Standard extended rotary handle for EasyPact CVS 100/160/250A 363 Spreader Links (Set of 4) 4P for EasyPact CVS 160/250A 364 Red Indicating Lamp 22.5mm with Integrated LED, Voltage: 240V AC SCHNEIDER/ABB/L&T (1.0 Nos) 365 Yellow Indicating Lamp 22.5mm with Integrated LED, Voltage: 240V AC SCHNEIDER/ABB/L&T(1.0 Nos) 366 Blue Indicating Lamp 22.5mm with Integrated LED, Voltage: 240V AC SCHNEIDER/ABB/L&T (2.0 Nos) 367 6A 1P 10kA C-Curve MCB,Type: K60H C&S/VAISHNO (3.0 Nos) 368 CABLES 369 Supply of 185SQMM 3.5 core LT aluminum PVC Insulated armoured cables. - FROM MAIN TRANSFORMER TO LT PANEL 370 Supply of 95SQMM 3.5 core aluminum Armoured - MAIN LT PANEL TO LTDB 371 Supply of 2.5SQMM 2 core Copper Armoured - BOUNDRY WALL LIGHTS CONNECTIONS 372 END TERMINATION - MAIN LT PANNEL & LTDB 373 185Sqmm End termination with materials 374 95Sqmm End termination with materials 375 EARTHING - OUTSIDE ELECTRICAL ROOM 376 GI Earthing 377 Copper Earthing 378 Supply & Laying of 25X3 GI strip with nut bolt & washers 379 LABOUR CHARGE ( FOR INSTALLATION OF LT PANEL, APFC PANEL, LTDB & LAYING OF CABLE) 380 WATER PROOFING & RAINWATER WORKS 381 Excavating trenches in all kinds ofsoil of required width for pipes. including excavation for sockets and dressing of sides, ramming of bottoms, including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc & disposing of surplus excavated soil as directed within a lead of 50m. up to 1.50 m depth , Pipes 80 mm to 300 mmdiameter DSR - 2.10.1.2 382 Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. DSR - 12.22 383 Providing and fixing of water proofing layer on the terrace on the exsisting floor of the terrace without removing the exsisting layer of PCC only cleaning included as per specMR 384 Constructing masonry Chamber 60X60X75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand ) for sluice valve, with C.I. surface box 100mm, top diameter, 160 mm bottom diameter and 180mm deep (inside) with chained lid and RCC top slab 1:2:4 mix ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 (1 cement :5 fine sand : 10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand ) 12 mm thick finished with a floating coat of neat cement complete as per standard design :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 DSR - 18.33.1 385 Providing and fixing on wall face unplasticised-Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ringconforming to IS: 5382 leaving 10mm gap forthermal expansion. - 110 MM DSR - 12.41.2 386 Providing of open drainAR 387 Mild steel or iron work of small sizes and sections such as holding down bolts, hold fast tierods,gratings etc. ( when not included in an over all rates) wrought to required from including supply of steel and its wastage including cost of bolts, nuts if required for and welding, grinding and making holes as required completion of work fabrication of holes doors, chaukhats nosing. Providing & fixing of door / windows grill. DRS -10.25.2 388 Landscraping work 389 Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. DSR-(2.31) 390 Providing and laying in position cement concrete of specified gradeexcluding the cost of centering and shuttering - All work up to plinthlevel :1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size) DSR - 4.1.8 391 Providing & Layingof 15 mm thickHeavy duty Exterior floor tiles of approved Brand and sample in size 600 x 600 mm which will be cutted in different sizes as per app. design with 3 to 6 mm spacer offirst quality of Bell, Johnson, Kajaria or equal make, shade, colour, and pattern as app. by engineer Incharge laid over base cement mortar 1:4 mix including finishing the joint with white cementand to make the joint as perthe approved design, drawing and specification and direction of EI. MR 392 Grouting the joints of flooring tiles having joints using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge.DSR(11.48.2) 393 Brick Workin super-structure above plinth level up to floor two level ( up to two storeys ) includingnecessarycutting and moulding of brick work asrequiredand also including honeycombed brick work in thickness of wall more than 12cms. (1:6 cement : coarse sand) DSR-6.4.2 394 supply and installation of steel bolads at propoer distance as directed by the architect inchargeMR 395 Supply and installation of stone benches as per layout and designas directed by the architect inchargeMR 396 Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement, 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage wherever required complete etc. as per direction of Engineer- in- charge ( length of finished kerb edging shall be measured for payment). (precast c.c. kerb stone shall be approved by Engineer - in - charge). DSR-16.69 397 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. DSR- 10.16.1 398 CIVIL-FACADE ESTIMATE 399 Dismentling of RCC work i/c stacking of dismantled material as directed by EI with in distance 50 Mtrs.DSR 15.3 400 Dismentling of RB work i/c stacking of dismantled material as directed by EI with in distance 50 Mtrs.DSR 15.4 401 Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead :Of area Beyond 3 sq.DSR 15.12.2 402 Dismentling of existing plasterand i/c stacking of dismantled material as directed by EI with in distance 60 mtrsDSR 15.56 403 Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved.DSR 15.60 404 12 mm cement plaster with 1:4 cement & coarsesand of 1.25 FMin single coatof single or half brick wall for interior plastering upto floor two level. DSR 13.4.1 405 Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. With cement mortar 1:4 (1cement: 4 coarse sand) DSR 14.1.2 406 Providing and laying in position cement concrete of specified gradeexcluding the cost of centering and shuttering - All work up to plinthlevel :1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size) DSR 4.1.8 407 Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after .The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineer-in-charge .The elevational area of the scaffolding shall be measured for payment purpose .The payment will be made once for every month for duration of scaffolding (Maximum 3 Months).DSR - 14.72 408 Providing & Fixing of Cluster Stone Brick Stamping of Size (8.46x2.36) & 13MM (Approx) Thick having Super Hard outer shell on Vertical Surface with uncoloured Adhesive FS complete as per desigh, drawings, specification & as approved by Architect/Engineer Incharge. MR 409 Supply&Fixingofwindowsmadefrommulti chambered UPVC profiles of minimum 60/108 mm thicknessof (Wintechmakeorequivalent)in natural from stailized for heat, light, impact & UV radiation. The UPVC profiles should be reinforced withgalzvanizedsteelprofilesofdesigned thickness.Floatglassofapprovedcolourin 4/5/6/8 mm or as desired by the costumer shall be fixed with heveled beads. All openable / sliding sashes shall be having grey/black colored weather seal fitted in continuous lenghts made from bubble PTV Rubber & side Hung with 90L openin friction syats of rust proof stainless steel with provision of multipoint lockng system (casement only) made from Espag rods (coated steel) all handle shall be made from die Cast zinc alloy in white finish only as per desigh, drawings, specification & as approved by Architect/Engineer Incharge. M.R 410 Providing & Fixing of Roller Blinds with Hand Rail of approved shade as per drawing & specificationas approved by Engineer -in-Charge. M.R 411 Providing & Fixing of Zebra Blinds with Hand Railof approved shade as per drawing & specificationas approved by Engineer -in-Charge. M.R 412 Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account).The weight of aluminium extruded section shall be taken for purpose of payment. DSR 25.1 413 Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel (Making Louvers & Groves) Cladding, with open grooves for linear as well as curvilinear portions of the building, for all heights and all levels etc. including:Structural analysis & design and preparation of shop drawings for pressure equalization or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design ) Providing, fabricating and supplying and fixing panels of aluminum composite panel cladding in Pan shape of approved shades made out of 3mm thick aluminum composite panel material consisting of 2.40mm thick non toxic low density polyethylene virgin core sandwiched between two Aluminum coated sheets (each 0.3mm thickof AA 3105 Alloy grade). The aluminum composite panel cladding sheet shall be coil coated, with Kynar 500 based/hylar 5000PVDF / Lumiflon based fluoropolymer resin lead 4.10 to 4.30 kg per sqm., nuts, bolts, washers, cleat drawings.DSR 25.2 414 Scraping of old white or colour wash including disposal of refuse as directed by EI with in distance 60 mtrs.DSR 13.88 415 Providing & Applying white cement based putty of average thickness 1 mm of approved brand and manufacturer over plastered surface to prapare the surface even & smooth complete.DSR 13.80 416 Finishing walls with textured exterior paint of required shade New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 DSR 13.45.1 417 ELECTRICAL WORK ESTIMATE 418 Supply and fixing of Decorative 45 Watt LED Post Top indirect light luminaire having Pressure die cast aluminium body and Clear glass with driver set confirming to IP 6565 Make-Klite, all complete as per drawing, specification and directionas approved by the Architect/ Engineer -in-ChargeMR 419 Supply and fixing of Decorative small decorate light withdirect dim light luminaire having Pressure die cast aluminium body and Clear glass with driver set confirming to , all complete as per drawing, specification and directionas approved by the Architect/ Engineer -in-ChargeMR 420 Supply and fixing of 200 AMP MCCB Box with load diverter for the connections to the guard room for the landscape lightsMR 421 Providing and laying of 2.5MM 3.5 core copper armored cable for street light connections as per specs MR 422 Providing and Fixing of RCC round base with foundation of bolts and spces for the 45 Watt LED Post Top indirect light luminaireMR 423 BOUNDRY WALL WORK RATE ANALYSIS FOR (2.5MTR) 424 Brick Workin super-structure above plinth level up to floor two level ( up to two storeys ) includingnecessarycutting and moulding of brick work asrequiredand also including honeycombed brick work in thickness of wall more than 12cms. (1:6 cement : coarse sand) DSR-6.4.2 425 Lime plaster 1:1:1 (1 lime putty : 1 surkhi : 1 finesand) INTACH SOR 2016 9.2.1 426 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works DRS -10.25.2 427 Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/ 10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand and manufacture DSR - 13.48.3 428 Supply and fixing of decorative plate on ms grill ralling with cold pressed impresion of fish and andaaz awadh as per specs.MR