| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 28-03-2025 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 04-04-2025 |
| Sl. No. | Item Description |
| 1 | Taking downoftower type AC 4 TR Capacityincluding cleaning of cooling coil, air filters , condenser, compressors, fan motor etc with vacuum cleaner OR cleaning solution includingcheckingthe serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, remote control unit including PCB, fan, blower, etc, changing connections from heating mode to cooling mode or vice-versa andkeepingthe AC unit in satisfactory working condition after necessary servicing/ repair/ replacement of defective spares as required and refixing the same in existing positioncomplete all specified and as directed.Notes :- (i) Replacement of defectivespares for making the AC units in satisfactory working conditionwill be measured & paidseparately under relevant items and Labour charges for taking out old spares & refixing of new sparesshall deemed to be included in unit quoted rate. (ii) Penaltywill be charged for not attending complaint from 12 Hoursto 24 hours Rs. 500/- each complaint. Furtherif complaint not attended and rectifiedwithin 24 hours after intimation (Intimation will be given by message/whats app/mail by mentioningtime of complaint,for that contractor has to submit his authorised reps details for receiving complaint) of complaint, failing which same will be got rectified through spot quotation by job order by any other agency and double of the job order amount to be deducted from contractors dues. |
| 2 | Supply and fixing Bimetal overload relay 6-10A. |
| 3 | Supply and fixingContractor MNX 12. |
| 4 | Supply & fixing Condenser fan blade of Aluminiumfor towertype A.C of Capacity 4 TR as per Existing size complete all specified and as directed. |
| 5 | Supply and fixingIn Repair single phase preventer VSP 1. |
| 6 | Disconnecting the main printed circuit board (PCB) and repair the PCB with electric accessories and sensors as per existing suitable for Tower AC of capacity 4 TR and refixing it complete with all testing and commssioningcomplete all specified and as directed. |
| 7 | Supply & fixing in repairs of suction valve set of size 15.9mm (5/8\"\") for Tower 4 TR capacity complete all specified and as directed.Note:- Supply & filling of refrigerant gasshall be measured and paid under relevent item. |
| 8 | Supply & fixing in repairs of Discharge valve set of size 9.52 mm (3/8\"\") for Tower 4 TR capacity complete all specified and as directed.Note:- Supply & filling of refrigerant gasshall be measured and paid under relevent item. |
| 9 | Supply & fixing in repairs of Expansion valve for tower type AC of capacity 4 TR complete all specified and as directed. |
| 10 | Disconnecting from mains and taking out existing unserviceable sealed compressor unit from the Tower type Air Conditioner of Cap4 Ton,of any make any type from any location complete all specified and as directed. |
| 11 | Supply , Installingand testing of new sealed unit compressor 4TR for Tower type Air Conditioner of Cap4 Ton includingcleaning and removing dust/dirt from the cooling coil condenser coilwith necessary modification of capillary tube etc&Charging of Gas R-22/R-134A/R-410 and commissioning complete all as specified & directed. Note :-1. Gas charging shall be paid spepartely under relevent item. 2. Transportation Charges from siteto trade workshop and back to original location after repair shall be deemed to be included in unit rate quoted above. |
| 12 | Disconnecting the mains and taking out the unserviceable condenser coilof Tower AC of capacity 4TR of any make from any location and supply, fixing and testing new condenser coil as per existing size & patterns for complete all as specified & as directed. |
| 13 | Supply & fixing in repairs of evaporator/cooling coil for tower type Air Conditioner of capacity 4 TRof existing make and size complete all as specified & as directed. |
| 14 | Dismantling and removing defective burnt blower unit motor of any capacity and make of indoor units of tower type AC of capacity 4 TR capacity rewinding the motor with enamel copper binding wire of existing guage and size including replacement of worn out motor bearing etc, refixing and testing complete all specified and as directed. |
| 15 | Dismantling and removing defective burnt outdoor unit motor of any capacity and make of indoor units of tower type AC of capacity 4 TR capacity rewinding the motor with enamel copper binding wire of existing guage and size including replacement of worn out motor bearing etc, refixing and testing complete all specified and as directed. |
| 16 | Supply and fixing in repairs of MCB TPN 240 volts 32 Amps, 10 kA, \"C\" curve complete all as specified and as directed. |
| 17 | Taking downfor servicingof split type AC 1.5/2 TR Capacityincluding cleaning of cooling coil, air filters/plasma filters etc, (Indoor unit), condenser, compressors, fan motor etc,(Out door unit) with vacuum cleaner or cleaning solution includingcheckingthe serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, Remote control unit including PCB, fan, blower, etc., keepingthe AC unit in satisfactory working condition after necessary servicing/ repair/ replacement of defective spares as required and refixing the same in existing position complete all specified and as directed . |
| 18 | All as per srl item No 17.00 here-in-before but window type AC ofcapacity 1.5/ 2 TR complete all as specified and as directed. |
| 19 | All as per srl item No 17.00 here-in-before but Tower type/ Cassette type AC of any capacity complete all as specified and as directed.Notes for Ser Item No 17 to 19 :-(i) The rates quoted by the contractor shall deemed to include the cost of taking down and fixing charge of \"S & F in replacement\" items.(ii)The spare parts required to be replaced shall be measured and paid separately under relevant items as \"S & F in replacement\". (iii)Contractor shall maintain register of servicing as per format given by Engr-in-Charge duly signed by User, where the servicing of equipment carry out and produce as and when asked complete all as specified and as directed. |
| 20 | Material & Labour for changing mode of any type of AC from heating mode to cooling mode or vice-versa complete all specified and as directed. |
| 21 | Material & Labour for rectifying electrical wiring fault of any capacity type AC and make them functional and also carry out the required repair complete all specified and as directed. |
| 22 | Notes for item No. 17.00 to 21.00 (i) Adequate resources and manpower shall be deployed by the contractor for attending day to day defect being an essential installation.(ii) Replacement of defectivespares for making the AC units in satisfactory working conditionwill be measured & paidseparately under relevant items as S & F in replacement and Labour charges for taking out old spares & refixing of new sparesshall deemed to be included in unit quoted rate. (iii) All complaint/repairs shall be attended/completedwithin 06 Hour failing which a recovery of Rs 500/- per day per complaint shall be made from contractor dues. |
| 23 | Supply & fixing in replacement Running capacitor 36+6 MFD. |
| 24 | Supply & fixing in replacement Running capacitor 45+5 MFD. |
| 25 | Supply & fixing in replacement Running capacitor 50+6 MFD. |
| 26 | Supply & fixing in replacement Starting capacitor 80-100 MFD. |
| 27 | Supply & fixing in replacement Starting capacitor 100-120 MFD. |
| 28 | Supply & fixing in replacement Starting Relay 1622. |
| 29 | Supply & fixing in replacement Starting Relay 2000. |
| 30 | Supply & fixing in replacement Thermostat switch 2059/2064/2054. |
| 31 | Supply & fixing in replacement Condenser fan blade for Window type A.C of Capacity 1.5/2 TR made of Plastic.(Make as per site requirement.) |
| 32 | Supply & fixing in replacement Condenser fan blade for spilt Type A.C of Capacity 1.5/2 TR made of Plastic.(Make as per site requirement.) |
| 33 | Supply & fixing in replacement Wiring kit for Window/split type AC of Capacity 1.5/2 TR.(Make as per site requirement.) |
| 34 | Supply & fixing in replacement remote control of existing make including battery for split AC Cap 1.5/2 TR of make as per site requirement and replace of old one complete all as specified & as directed |
| 35 | Taking down unserviceable reversible valve for split AC of capacity 1.5TR and supply & fixing new reversible valve with solenoid coil including required different copper pipe with PCB and remote alteration/modification complete all as specified and directed. Note :- (i)Supply & filling of refrigerant gasshall be measured and paid under relevant item.) (ii) Any alteration or modification including electronic component required in PCB and Remote to be paid under relevant items. |
| 36 | ditto- all as per item No. 35 above but window type Air Conditioner of capacity1.5 TR. |
| 37 | ditto- all as per item No. 35 above but window type Air Conditioner of capacity2 TR. |
| 38 | ditto- all as per item No. 35 above but spilt type Air Conditioner of capacity2 TR. |
| 39 | Material & Labour forCarryout the repairing work in remote control of AC of any type and any capacity complete all as specified and directed to be included in above quoted rates. |
| 40 | Material & Labour forCarryout the pressure test with nitrogen gas of refrigeration system, detecting leakage including soldering and brazing of leaking copper tubing complete all as specified and directed. |
| 41 | Taking down, repairing and re-fixing main printed circuit board (PCB) with electric accessories and sensors suitable for inverter type split type AC/ window type AC ofany capacity and modelcomplete all as specified and directed. |
| 42 | Supply & fixing in repair PCB, suitable for inverter type, split type AC/ window type AC of any capacity and model complete all as specified and as directed. |
| 43 | Taking down, repairing and re-fixingPCB, suitablefor split type AC/ window type AC ofany capacity and modelcomplete all as specified and directed. |
| 44 | Supply & fixing in repair PCB suitable for split type AC/ window type AC of any capacity and model complete all as specified and as directed. |
| 45 | Supply & fixing in repairs plastic louvers for (Front panel)for Window AC 1.5/2 TR complete all as specified & as directed (Make as per Sample). |
| 46 | Supply & fixing in repairs of suctionand discharge valve set of size 15mm (5/8\"\"), 6mm (1/4\"\") and 12mm (1/2\"\")for Split AC 1.5/2 TR capacity complete all as specified & as directed.Note:-(i) 15mm (5/8\"\") or 6mm (1/4\"\") and 12mm (1/2\"\") made one set(ii) Supply & filling of refrigerant gasshall be measured and paid under relevant item. |
| 47 | Supply & fixing in repairs of capillary tube for Split/ Windowtype AC of capacity 1.5/2 TR complete all as specified & as directed (Make as per Sample). |
| 48 | Supply & fixing in repairs of capillary filter for Split/ Windowtype AC of capacity 1.5/2 TR complete all as specified & as directed (Make as per Sample). |
| 49 | Disconnecting from mains and taking out existing unserviceable sealed compressor unit and supply & fixing in replacement sealed compressor unit with latest refrigerant gas compatible, suitable for 1.5 TR window type AC/ Split AC of existingcapacity and makecomplete includingcleaning and removing dust/dirt from the cooling coil condenser coilwith necessary modification capillary tube etc and commissioning complete all as specified & as directed. |
| 50 | ditto- all as per item No. 49 above but suitable for 2.0 TR window type AC/ Split AC. |
| 51 | Supply & fixing in replacement of Window A/C air blower motor copper wounded for 1.5 TR & 2 TR capacity AC complete all as specified & as directed. |
| 52 | Supply & fixing in replacement of Indoor Air blower motor for Split 1.5 TR & 2 TR capacity complete all as specified & as directed. |
| 53 | Supply & fixing in replacement of copper wounded motor for outdoor of Split type AC of 1.5 TR & 2 TR capacity complete all as specified & as directed. |
| 54 | Material & Labour for Disconnecting the mains and taking out the unserviceable condenser coilof window type AC of capacity 1.5/ 2TR of any make from any location and Carryout the pressure test of refrigeration system, detecting leakage including soldering and brazing of leaking copper tubing complete all as specified and directed. |
| 55 | ditto- all as per item No. 54 above but spilt type Air Conditioner Capacity 1.5/ 2 TR. |
| 56 | Material & Labour for Disconnecting the mains and taking out the unserviceable evaporator/cooling coilof window type AC of capacity 1.5/ 2TR of any make from any location and Carryout the pressure test of refrigeration system, detecting leakage including soldering and brazing of leaking copper tubing complete all as specified and directed. |
| 57 | ditto- all as per item No. 56 above but Window type Air Conditioner Capacity 2 TR. |
| 58 | Taking down unserviceable outdoor unitof split type AC of any capacity as directed by engineer in charge. |
| 59 | Supply and fixing 1.5 TR capacity split type Air Conditioner outdoor kit with latest refrigerant gas compatible including condenser coil with protection fins, blower motor and its fan blade, chassis & base plate with outdoor coveringwithout compressor, suction and discharge valve, capillary tube of expansion valve,contactor with PCB card, capacitors and copper pipes & PVC wires of suitable size for internal connection, etc. complete all as specified & as directed. |
| 60 | ditto- all as per item No. 59 above but spilt type Air Conditioner of capacity2 TR. |
| 61 | Taking down unserviceable indoor unitof split type AC of capacity 1.5 TR with remote complete all as specified & as directed. |
| 62 | Supply & fixing new indoor unit with remote control and with latest refrigerant gas compatible complete set suitable for 1.5 TRcapacity complete all as specified & as directed. |
| 63 | ditto- all as per item No. 62 above but spilt type Air Conditioner of capacity2 TR. (Note :- Outdoor and indoor unit of AC shall be compatible either with each other orexisting units) |
| 64 | Disconnecting from mains and taking out existing unserviceable sealed inverter DC compressor unit and supply & fixing in replacement sealedinverter DC compressor unit with latest refrigerant gas compatible, suitable for 1.5 TR window type AC/ Split AC of existingcapacity and makecomplete includingcleaning and removing dust/dirt from the cooling coil condenser coilwith necessary modification capillary tube etccommissioning complete all as specified & as directed.(Make as per existing on site ) |
| 65 | Taking down unserviceable indoor unitof inverter split type AC of capacity 1.5 TR andsupply & fixing new inverter type indoor unit complete set suitable for 1.5 TRcapacity complete all as specified & as directed.(Make as per existing on site ) |
| 66 | Supply and fixing in repairs 1.5 TR capacity inverter type split type Air Conditioner outdoor kit including condenser coil, blower motor, chassis, base plate , suction and discharge valve, contactor, capacitors and copper pipe, PVC wires, PCB compatible to indoor unit, of suitable size for internal connection, etc. including taking down old unserviceable one complete all as specified & as directed. (Make as per existing on site ) |
| 67 | Supply & fixing in replacement heavy duty copper pipe 12mm (1/2\") dia/ bore complete including insulation brazing, welding, nuts,bolts and screws of required size including taking down old unserviceable one complete all as specified and directed. |
| 68 | ditto- all as per item No. 67 above but copper pipe 6mm (1/4\") dia/ bore. |
| 69 | ditto- all as per item No. 67 above but copper pipe 15mm (5/8\") dia/ bore. |
| 70 | ditto- all as per item No. 67 above but copper pipe 10mm (3/8\") dia/ bore. |
| 71 | Taking down unserviceable insulation for copper pipe, supply and fixing new insulation for copper pipes suitable for Split AC of capacity from 1.5 to 4.0 TR complete all as specified & as directed. |
| 72 | Taking down unserviceable PVC drain pipe and supply & fixing new PVC drain pipe 15 mm dia for Split/window AC complete all as specified & as directed. |
| 73 | Material & Labour for complete topping up the refrigerant gas( R22) in split/window type 1.5 TR & testing and commissioning complete in satisfactory working condition complete all as specified & as directed. |
| 74 | Material & Labour for complete topping up the refrigerant gas( R22) in split/window type 2.0 TR & testing and commissioning complete in satisfactory working condition complete all as specified & as directed. |
| 75 | Material & Labour for complete topping up the refrigerant gas( R32/ R410A) in split/window AC type 1.5 TR & testing and commissioning complete in satisfactory working condition complete all as specified & as directed. |
| 76 | Material & Labour for complete topping up the refrigerant gas( R32/R410A) in split/window AC type 2.00 TR & testing and commissioning complete in satisfactory working condition complete all as specified & as directed. |
| 77 | Material & Labour for complete topping up the refrigerant gas( R22/ R32/R410A) in Tower / Cassette AC type & testing and commissioning complete in satisfactory working condition complete all as specified & as directed. |
| 78 | Taking down unserviceable contactor and supply and fixing new contactor single phase suitable for window/ Split AC 1.5 to 2.0 TR complete all as specified & as directed. |
| 79 | Taking down unserviceable contactor and supply and fixing new contactor ( MNX 12/ MNX 18) suitable for Tower / Cassette AC up to 4.0 TR capacity complete all as specified & as directed. |
| 80 | Dismantling the existing broken blower fan blade of the indoor units of the split type AC of Capacity 1.5/2 TR and supply and fixing in repairs new blower fan blade complete all as specified and directed. |
| 81 | Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc. and making good, cutting exceeding 20cm girth as specified and directed. |
| 82 | Supply and fixing in replacement UPVC piping of dia 25mm complete with fittings, supports and duly covered complete all as specified & as directed. |
| 83 | Supply & fixing in replacement Outdoor Unit (ODU) Stand for 1.5TR/ 2 TR Type split AC complete all as specified & as directed. |
| 84 | Dismantling and Refixing the Split AC of 1.5/2 TR Including Drilling of holes into a brick wall for connecting Indoor with Outdoor Unit’s pipes and Connecting indoor and outdoor units with copper pipes and installation of drainage pipes and Fixing Outdoor unit on separately ODU stand, Temperature & gas pressure testing, gas charging,Carpentry work, Plumbing, masonry & white cementing complete all as specified & as directed.Note :- Drain Pipe, Copper of required size, Refrigerant gas , Outdoor stand , power plug, MCB and Copper wire will be paid under relevant item |
| 85 | Supply and fixing in repairs 1.5 TR capacity window type AC kit including condenser coil & evaporator coil (copper), copper wounded blower motor, cooling coil, front grill blower motor, chassis, base plate, reverse valve, capacitors and copper pipes & PVC wires of suitable size for internal connection etc including taking down old one complete all as specified and as directed . |
| 86 | Material and labour for sub main wiring with two runs of single core 6 Sqmm (nominal area) PVC insulated copper conductor FRLS (conforming to IS-694), multistranded,unsheathed1100 volts grade in PVC casing capping(heavy grade) of adequate size with all fittings and casing cappingaccessories of surface type including one run 6 Sqmm single core unsheathed multistranded copper conductor cable FRLS (conforming to IS-694)as earth wire including taking down old unserviceable sub main wiring complete all as specified and as directed. |
| 87 | ditto- all as per item No. 86 above but sub main wiring with two runs of single core 4 Sqmm |
| 88 | Supply and fixing in repairs of metal clad socket outlet with single pole and neutral enclosure with two pin and earth plug socket complete with one single pole MCB 32 Amps including taking down old unserviceable metal clad socket complete all as specified and as directed. |
| 89 | Supply and fixing in repairs of MCB SP 240 volts 6 to 32 Amps, 10 kA, \"C\" curve complete all as specified and as directed. |
| 90 | Supply & fixing in repair metal clad socket of 20 Amps complete all as specified & as directed. |
| 91 | Supply & fixing in repairs metal clad plug with two pin of capacity 20 Ampscomplete all as specified & as directed. |
| 92 | Supply & fixing in replacement wall mounted digital Voltage Stabilizer for automatic operation, single phase, naturally air cooled, indoor type & designed for input variation between 150V - 285 V with output voltage stabilized at 230V with accuracy of + 2.5% and of capacity 5 KVA complete all as specified and as directed. Make: V-Guard model No-VND 500 or equivalent model of Bluebird, Emerson or any other Make mentioned in PS. |
| 93 | Disconnecting from mains and taking downfor servicingofWater Cooler ofCapacity 40/80, 60/120,Litres including cleaning of cooling coil, air filters , condenser, compressors, fan motor etc with vacuum cleaner or cleaning solution includingcheckingthe serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs,fan andblower, etc., andkeepingthe Water coolerunit in satisfactory working condition after necessary servicing/ repair/ replacement of defective spares as required and installation in same location complete all as specified and as directed .Note :- 1. Replacement of defectivespares for making the water cooler units in satisfactory working condition will be measured & paidseparately under relevant items and Transportation & labour charges for taking down old spares and fixing of new sparesshall deemed to be included in unit rate quoted above. |
| 94 | Supply & fixing in replacement over load protector relay suitable for 40/80 Litres capacity water coolers. |
| 95 | Supply & fixing in replacement thermostat suitable for 40/80/120/150 Litre capacity water coolers. |
| 96 | Supply & fixing in replacement condenser motor fan blade suitable for 40/80/120/150 Litre capacity water coolers. |
| 97 | Supply & fixing in replacement PVC flexible drain Hose Pipe 40 mm. |
| 98 | Supply & fixing in replacement waste water tray complete suitable for 40/80, 60/120, 150/150 Litre capacity water coolers ( Suitable for Voltas/Sidwal/Blue Star make water coolers). |
| 99 | Supply & fixing in replacement chromium plated push taps suitable for 40/80/120/150 Litre capacity water coolers all as directed. |
| 100 | Supply & fixing in replacement PVC float valve of size 15mm dia complete suitable for 40/80/120/150 Litre capacity water coolers including GI socket of same size all as directed. |
| 101 | Supply & fixing in replacement Starting Capacitor 25 MFD. |
| 102 | Supply & fixing in replacement running Capacitor 10 MFD. |
| 103 | Supply & fixing in replacement Starting relaysuitable for 40/80, 60/120, 150/150 Litre. |
| 104 | Disconnecting the electric mains and taking out unserviceable condenser fan motor1/16 HP from water cooler cap.60/120, 150/150 Litre and supply and fixing with new motor single phase AC 220 V of same capacity including reconnecting the electric connections and testing complete all as specified & as directed. |
| 105 | All as per item No.104 above but 1/32 HP Water coolerofCapacity 40/80 Litres. |
| 106 | Dismantling and removing defective compressor and supply and fixing in repairs new sealed compressor of approved make obtained from authorised dealers commissioning and testing Water Coolers of 40/80 Litres capacity complete all as specified and as directed. |
| 107 | Dismantling and removing defective compressor and supply and fixing in repairs new sealed compressor of approved make obtained from authorised dealers , commissioning and testing Water Coolers of 60/120 Litres capacity complete all as specified and as directed. |
| 108 | Dismantling and removing defective compressor and supply and fixing in repairs new sealed compressor of approved make obtained from authorised dealers , commissioning and testing Water Coolers of 150/150 Litres capacity complete all as specified and as directed. |
| 109 | Disconnecting the mains and taking out the unserviceable condenser coil and supply & fixing new condenser coil as per existing size & patterns for Water Coolers of capacity 60/120, 150/150 Litres complete all as specified & as directed. |
| 110 | Disconnecting the mains and taking out the unserviceable condenser coiland supply & fixing new condenser coil as per existing size & patterns for Water/Coolers of capacity 40/80Litres complete all as specified & as directed. |
| 111 | Dismantling the evaporator/cooling coil of water cooler capacity 150/150, 60/120 & 40/80 Litres, checking the leakages of gas and rectify the leakages by brazing or as other manner complete all as specified & as directed (Make :- As per Sample) |
| 112 | Taking down unserviceable PVC connection pipe and Supply and Fixing of PVC connections 15 mm dia bore with PTMT nuts of length 900 mm complete all as specified & as directed. |
| 113 | Dismantling and removing defective compressor and supply and fixing (in repairs) new sealed compressor of approved make obtained from authorised dealers and commissioning and testing of refrigerators of 165 to 210 Litres capacity complete all as specified and as directed. |
| 114 | Dismantling and removing defective compressor and supply and fixing (in repairs) new sealed compressor of approved makeincluding charging of refrigerant gas R-22/134A, commissioning and testing of refrigerators of 280 to 310 Litres capacity complete all as specified and as directed.Note :-The rates quoted by the contractor shall deemed to include the transportation cost from site of installation to contractor\"s repair workshop and back. |
| 115 | Disconnecting from mains and taking downfor servicingof RefrigeratorofCapacity 165/180/195/250/310 and 330 Litresincluding detecting the leakage of gas and cleaning of cooling coil, condenser, compressors, with vacuum cleaner or cleaning solution includingcheckingthe serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, etc., andkeepingthe Refrigerator unit in satisfactory working condition after necessary servicing/ repair/ replacement of defective spares as required complete all as specified and as directed .Note :- Replacement of defectivespares for making the Refrigerator units in satisfactory working condition will be measured & paidseparately under relevant items and Labour charges for taking out old spares and fixingof new sparesshall deemed to be included in unit rate quoted. |
| 116 | Supply and filling refrigerant gas R-134A/R32/R410/R600 in Refrigerators/ Deep freezers/ Water coolers of any capacity, model and make complete all as specified and directed. |
| 117 | Material & Labour for detecting the leakage of gas of Refrigerators/ Deep freezers/ Water coolers at any location and rectifying the defect to stop the leakage by gas welding or by any other means including cutting and brazing of copper tubes testing and commissioning complete in satisfactory working condition complete all as specified & as directed. |
| 118 | Supply & fixing in replacement capillary tube of existing size including necessary brazing suitable for 165/300 litres capacity refrigerator complete all as specified & as directed(Make :- As per Sample). |
| 119 | Supply & fixing in replacement overload protector relay suitable for 165/300/310 litres capacity refrigerator all as directed. |
| 120 | Supply & fixing in replacement thermostat suitable for 165/300/310 litres capacity refrigerators all as directed. |
| 121 | Supply & fixing in replacement freezer door with spring of refrigerators of any capacity all as directed (Suitable for Whirlpool/ LG/Samsung/ Godrej make refrigerator). |
| 122 | Supply & fixing in replacement vegetable basket with glass suitable for 165/300/310 litres capacity refrigerators all as directed (Suitable for Whirlpool/ LG/Samsung/ Godrej make refrigerator). |
| 123 | Supply & fixing in replacement PVC defrost tray as per sample suitable for 165/300/310 litres capacity refrigerators (Suitable for Whirlpool/ LG/Samsung/ Godrej make refrigerator). |
| 124 | Supply & fixing in replacement door gasket for refrigerators of capacity up to 250 Litres complete all as specified and directed (Suitable for Whirlpool/ LG/Samsung/ Godrej make refrigerator). |
| 125 | Supply & fixing in replacement door gasket for refrigerators of capacity more than 250 Litres but up to 310 litres complete all as specified and as directed. (Suitable for Whirlpool/ LG/Samsung/ Godrej make refrigerator).Note:- Material of item Nos. 116 to 124 to be incorporated in item No 115 here-in-before. |
| 126 | Disconnecting from mains and taking downfor servicingof Deep freezerofCapacity 165/180/195/310/330/450 and 500 Litresincluding detecting the leakage of gas and refilling of refrigerant ,cleaning of cooling coil, condenser, compressors, with vacuum cleaner or cleaning solution includingcheckingthe serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, etc., andkeepingthe Refrigerator unit in satisfactory working condition after necessary servicing/ repair/ replacement of defective spares as required complete all as specified and as directed .Note :- Replacement of defectivespares for making theDeep Freezer units in satisfactory working condition will be measured & paidseparately under relevant items and Labour charges for taking out old spares and fixingof new sparesshall deemed to be included in unit rate quoted. |
| 127 | Supply & fixing in replacement starting relay 1/6 HP open with OLP. |
| 128 | Supply & fixing in replacement starting relay for 1/8 HP open type with OLP. |
| 129 | Supply & fixing in replacement over load protector relay suitable for up to 500 Litres capacity deep freezer. |
| 130 | Supply & fixing in replacement running capacitor for up to 500 Litres capacity deep freezer. |
| 131 | Supply & fixing in replacement thermostat suitable for up to 500 Litres capacity deep freezer. |
| 132 | Supply & fixing in replacement starting capacitor for up to 500 Litres capacity deep freezer. |
| 133 | Supply & fixing in replacement Axial Fan for deep freezers. |
| 134 | Taking down defective compressor of deep freezer of capacity Upto 300 Litres and any make and supplying and fixing new sealed unit compressor as specified here under including brazing and with necessary nuts and bolts, copper filter, capillaryand testing complete all as specified and directed . |
| 135 | All as per item No 134 above but of capacity above 300 Litres but up to 500 Litres deep freezer compressors. |
| 136 | Material & Labour forpainting outside body with synthetic enamel paint of existing tint/colour of 10 KVA voltage stablizer complete all as specified and as directed. |
| 137 | Material & Labour for on line Dehydration/filteration of Servo Voltage Stablizer oil including filteration using automatic centrifuging machine minimum three cycles to achieve dielectric strength 40 to 60 KV breaking capacity at 2.5mm gap by absorbing and abolishing all sludge particles as per BS-66-1963 including topping up with new transformer oil as required complete all as specified and as directed.Note :- (i)Centrifuging Machine with all T&P & testing machine of oil required for dehydration shall be arrange by contractor.(ii) Oil required for topping up the stablizer will be measured & paid separately as supply only under respective item of this Sch. |
| 138 | Supplying and filling/topping up transformer oil low viscocity, dielectric strength 35 to 40 KV breaking voltage for topping up servo voltage stablizers duly centrifuging including filter action by using automatic centrifuging machine to achieve min 35 to 40 KV breaking capacity at 4 mm gap by absorbing and abolishing all sludge particles for use as per BS-B-66-1983 complete all as specified and as directed.. |
| 139 | Supply, installation, testing and commissioningin replacement complete indoor unitfor tower type split AC of 4 TR, inclusive ofblower motor, blower, PCB circuit ,wiring kit with cooling coil etc,suitable for R-410A/R-32 Gas, including all copper tubing of required size & electrical cabling up to 5 metre all as required as per site complete all as specified and directed.Indoor Unit Technical specification- Nominal cooling cap -3.5 TR, Indoor fan motor-300 watt, Dimension(WXDXH): 55 cm X 35 cm X 180 cm. Gross weight: 60-70 KG, Operating temp.- >17 °C, Controller-Remote Control, IDU Noise (dB)-52 dB, Air Flow (m³/h)-1680 m³/h, Input Power (W)-5490 W, Cooling Capacity (W)13500 W. |
| 140 | Supply, installation, testing and commissioningin replacement complete outdoor unit for Tower type split AC of 4 ton, without scroll compressor, suitable for R-410A/ R-32 Gas,condenser coil, wiring kit , condenser fan motor, condenser fan, terminal etc also making platform for outdoor unit with suitable size of fastener and MS frame work stand and making good the disturb surface including all copper tubing of required size, control wiring all as required as per site complete all as specified and directed.Outdoor Unit Technical specification- Power Supply- 3 phase, 380-415 Volt, 50 Hz, Outdoor fan motor-290 watt, Fan motor speed-830 RPM, Dimensions(WXDXH): 94.6 cm x 41.0 cm x 81.0 cm, Gross weight - 75-93 KG, Refrigerant piping-Max pipe lenght-20 mtr, Max difference in level-10 mtrNote :- The outdoor unit shall be replaced from roof of building of height 40-50ft. |
| 141 | Taking downfor servicingof inverter type split type AC 1.5/2 TR Capacityincluding cleaning of cooling coil, air filters/plasma filters etc, (Indoor unit), condenser, compressors, fan motor etc,(Out door unit) with vacuum cleaner or cleaning solution includingcheckingthe serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, Remote control unit including PCB, fan, blower, etc., keepingthe AC unit in satisfactory working condition after necessary servicing/ repair/ replacement of defective spares as required and refaxing the same in existing position complete all specified and as directed. |
| 142 | Taking down unserviceable reversible valve forinverter type split AC of capacity 2/1.5TR and supply & fixing new reversible valve with solenoid coil including required different copper pipe with PCB and remote alteration/modification complete all as specified and directed. Note :- (i)Supply & filling of refrigerant gasshall be measured and paid under relevant item.(ii) Any alteration or modification including electronic component required in PCB and Remote to be paid under relevant items. |