| 1 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel / PVC conduit as required. 3x2.5 sq.mm |
| 2 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed heavy class PVC conduit as required 4x6+ 2x6 sq.mm |
| 3 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, in bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 Way Double Door |
| 4 | S/F of following sizes of Heavy class PVC conduit/Batten along with all accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm |
| 5 | S/F of suitable size G.I box with modular plate and cover in front or surface in recess including providing and fixing 6 pin 5/6 & 15/16A modular socket outlet and 15/16 A modular switch, connection etc |
| 6 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 x 25 sqmm |
| 7 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 8 | Single Pole |
| 9 | Single Pole and Neutral |
| 10 | Triple Pole and Neutral |
| 11 | Supplying , fixing and laying of one number PVC insulatedand XLPE sheathed /XLPE aluminium armoured conductorpower cable confirming to1.1 KV grade of following size direct in ground includingexcavation, sand cushioning , protective covering ,refilling the same etc as reqd. 4x25 sq.mm |
| 12 | Supplying and fixing following 100 amp four pole RCBO\"s ( three phase and netural )415 volts residual current circuit breaker with overcurrent protection having a sensitivity upto 100 mA miliampers in the existing MCB DB complete with connections, testing and commissioning etc. as required. ( Hagger/L&T) |
| 13 | P/F installation,testing and commissioing of following MCCB AC microporcessor tripping relaycomplete with connection and accessoriesetc as reqd. at site100 amps MCCB 3 pole 16 KA |
| 14 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 12 way double door 160 A ( VTPN IP43 make Legrand ) |
| 15 | Supplying and fixing following 32 amp TP MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 16 | S/F of following material for reparing of four pole Spectronic ACB\"s of GE make 1600/1250 Amp complete with all acssesories as requiored at site. |
| 17 | Cluster Contact |
| 18 | Pole Assembly |
| 19 | Moving arcing contact |
| 20 | Fix contact with base |
| 21 | Servicing of existing main LT panel comprising of ACBs and MCCBs with proper tools and testing equipments i/c tightening of bolts(Busbar, ACB etc.), cleaning of panel with Blower and dry cloths etc. as required at site. |
| 22 | Modification of exisitng LT panel suitable for intallation of MCCB\"s by replacing existing power scanner including panel doors, back support plate , bus bar strip connector, netural link , bus bar etc as reqd. at site |
| 23 | Supplying and fixing of digital volt meter (0-500V) and making connection etc as reqd. at site |
| 24 | Supplying and fixing of digital Amp meter (0-200A) and making connection etc as reqd. at site |
| 25 | Supplying and fixing of indication lamp ( RYB) etc as reqd. at site for 230 V AC |