Educational and Research Institute Government Departments Closing in 0 days TDR #48115789

Tender For Supply Of Uv-Vis Spectrophotometer Under Bckv, Mohanpur, Nadia , • Type- Uv-Vis Spectrophotometer • Light Source-Deuterium Lamp: Uv Range (190–400 Nm)- Tungsten Lamp: Visible To Near Infrared Range (400–1100 Nm); Optical Switching: Automat

Issued by Government Departments · mohanpur, West Bengal
Tender Value
Ref. Documents
Estimated cost
Bid Submission
17 Mar 2025
0 days left
EMD
4500
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
mohanpur → West Bengal
EMD Exemption
Available
Quantity
Not Available

Project Description

Supply Of Uv-Vis Spectrophotometer Under Bckv, Mohanpur, Nadia , • Type- Uv-Vis Spectrophotometer • Light Source-Deuterium Lamp: Uv Range (190–400 Nm)- Tungsten Lamp: Visible To Near Infrared Range (400–1100 Nm); Optical Switching: Automatic And Seamless Transition Between Light Sources Without Requiring Optical Recalibration Or Manual Adjustment; Lamp Replacement: Hot-Swappable Without Optical Misalignment Or Recalibration • Detector -One-Photodiode • Grating -Holographic Diffraction Grating -1200Mm Lines/Mm • Automatic Function- A) Automatic Lamp Section; B) Automatic Wavelength Selection, Filter Selection; C) Automatic Dark Correction D) Automatic Cuvette Selection- Five Position • Range Of Operation-Wavelength 190 Nm To 1100Nm; Photometric Absorbance Up To + 4.0 Abs; Transmittance 0 To 100 %T • Bandwidth 1.0 Nm • Resolution 0.1 Nm, 0.001 Abs & 0.1 %T • Measurement Mode- %T, Abs, Concentration (By K-Factor, By Standard, Or By Saved Standard), Dna And Protein And Enzymeanalysis, Multicomponent Analysis, Fluoride Analysis, Nitrate Analysis, Spectrum Scan And Time Scan (Full Spectrum Acquisition For Absorbance And Transmittance Profiling) • Path Length -Default 10 Mm Path Length, Compatible With 20 Mm, 40 Mm, 50 Mm & 100 Mm • Accuracy- Wavelength ± 0.5 Nm; Absorbance ± 0.005 Abs; Transmittance ± 0.5%T • Display- In-Built Display , 4 Line 20 Char Alpha Numeric Lcd • Os-Windows 10 Or Higher; Power Supply -230 V± 20 Volt And 50Hz • Operating Temperature- 8 – 48 Degree Celsius; Operating Humidity 40 To 85 % • In-House Memory: 1024 Mb Flash Memory For Storing Extensive Datasets, Calibration Curves, And Method Files; Data Export Capability: Supports Direct Data Export Via Usb To Excel For Post-Analysis, With Real-Time Data Transfer Through Usb Interface; Data Ports: Usb Host, Usb Device, Rs-232 Serial Port, Sd Card Slot For External Memory Expansion. • Accessories 2 Number Cuvette, Pen Drive, Usb Cable, Manuals • Having Password Protection, Administrator And User Login And Audit Trial • Two Year Warranty

BOQ

Name of Work: Publication of Atlas
Sl. No. Item Description
1• Type- Uv-Vis Spectrophotometer• Light Source-Deuterium Lamp: UV Range (190–400 nm)- Tungsten Lamp: Visible to Near Infrared Range (400–1100 nm); Optical Switching: Automatic and seamless transition between light sources without requiring optical recalibration or manual adjustment; Lamp Replacement: Hot-swappable without optical misalignment or recalibration• Detector -One-Photodiode• Grating -Holographic diffraction Grating -1200mm lines/mm• Automatic function- a) Automatic lamp section; b) Automatic wavelength selection, filter selection; c) Automatic Dark correctiond) Automatic Cuvette Selection- Five position• Range of operation-Wavelength 190 nm to 1100nm; Photometric Absorbance Up to + 4.0 Abs; Transmittance 0 to 100 %T• Bandwidth 1.0 nm• Resolution 0.1 nm, 0.001 Abs & 0.1 %T• Measurement mode- %T, Abs, Concentration (By K-factor, BY standard, or BY saved Standard), DNA and Protein and enzymeanalysis, Multicomponent analysis, Fluoride analysis, Nitrate analysis, Spectrum scan And Time Scan (Full spectrum acquisition for absorbance and transmittance profiling)• Path length -Default 10 mm path length, compatible with 20 mm, 40 mm, 50 mm & 100 mm• Accuracy- Wavelength ± 0.5 nm; Absorbance ± 0.005 Abs; Transmittance ± 0.5%T• Display- In-built Display , 4 LINE 20 CHAR Alpha Numeric LCD• OS-Windows 10 or Higher; Power supply -230 V± 20 volt and 50Hz• Operating temperature- 8 – 48 degree Celsius; Operating humidity 40 to 85 %• In-House Memory: 1024 MB Flash Memory for storing extensive datasets, calibration curves, and method files; Data Export Capability: Supports direct data export via USB to Excel for post-analysis, with real-time data transfer through USB interface; Data Ports: USB Host, USB Device, RS-232 Serial Port, SD Card Slot for external memory expansion.• Accessories 2 number cuvette, pen drive, USB cable, Manuals• Having Password Protection, Administrator and User Login and Audit Trial • Two year warranty

AI Tender Summary

OUR REF NO 48115789
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 17-03-2025
Authority
Authority Name Bidhan Chandra Krishi Viswavidyalaya
Work Description Supply Of Uv-Vis Spectrophotometer Under Bckv, Mohanpur, Nadia , • Type- Uv-Vis Spectrophotometer • Light Source-Deuterium Lamp: Uv Range (190–400 Nm)- Tungsten Lamp: Visible To Near Infrared Range (400–1100 Nm); Optical Switching: Automatic And Seamless Transition Between Light Sources Without Requiring Optical Recalibration Or Manual Adjustment; Lamp Replacement: Hot-Swappable Without Optical Misalignment Or Recalibration • Detector -One-Photodiode • Grating -Holographic Diffraction Grating -1200Mm Lines/Mm • Automatic Function- A) Automatic Lamp Section; B) Automatic Wavelength Selection, Filter Selection; C) Automatic Dark Correction D) Automatic Cuvette Selection- Five Position • Range Of Operation-Wavelength 190 Nm To 1100Nm; Photometric Absorbance Up To + 4.0 Abs; Transmittance 0 To 100 %T • Bandwidth 1.0 Nm • Resolution 0.1 Nm, 0.001 Abs & 0.1 %T • Measurement Mode- %T, Abs, Concentration (By K-Factor, By Standard, Or By Saved Standard), Dna And Protein And Enzymeanalysis, Multicomponent Analysis, Fluoride Analysis, Nitrate Analysis, Spectrum Scan And Time Scan (Full Spectrum Acquisition For Absorbance And Transmittance Profiling) • Path Length -Default 10 Mm Path Length, Compatible With 20 Mm, 40 Mm, 50 Mm & 100 Mm • Accuracy- Wavelength ± 0.5 Nm; Absorbance ± 0.005 Abs; Transmittance ± 0.5%T • Display- In-Built Display , 4 Line 20 Char Alpha Numeric Lcd • Os-Windows 10 Or Higher; Power Supply -230 V± 20 Volt And 50Hz • Operating Temperature- 8 – 48 Degree Celsius; Operating Humidity 40 To 85 % • In-House Memory: 1024 Mb Flash Memory For Storing Extensive Datasets, Calibration Curves, And Method Files; Data Export Capability: Supports Direct Data Export Via Usb To Excel For Post-Analysis, With Real-Time Data Transfer Through Usb Interface; Data Ports: Usb Host, Usb Device, Rs-232 Serial Port, Sd Card Slot For External Memory Expansion. • Accessories 2 Number Cuvette, Pen Drive, Usb Cable, Manuals • Having Password Protection, Administrator And User Login And Audit Trial • Two Year Warranty
Basic Detail
Tender No CA/BWN/136/24-25
Bidding Type Tender
Location
City mohanpur
State West Bengal
Key Dates
Publish Date 06 Mar 2025
Submission Date 17 Mar 2025
Open Date 19 Mar 2025
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD 4500
Exemption Available
Document List
Tendernotice_1.pdf
95078a41-9629-43a0-badb-8d7704bb660f.html
BOQ_1833997.xls

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Mar 06, 2025
11:30 IST

Tender Published

Tender notice published.

Completed
Mar 17, 2025
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Mar 19, 2025

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
pdf

Tendernotice_1.pdf

html

95078a41-9629-43a0-badb-8d7704bb660f.html

xls

BOQ_1833997.xls

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders