| 1 | SECTION - A : ELECTRICALCABLING WORKS |
| 2 | Installation and laying of LT XLPE or FR or FRLSZH LT Cables insulated armoured, making good the damages,on existing trays/ walls/ columns /indoor /trenches including the cost of supports with suitable clamps, saddles, hooks, bolts etc. and including end termination, the cost of proper dressing of cables, markers providing identification tags, earthing of glands armouring etc. conforming to the specifications, as required and as below |
| 3 | Upto 4 Sqmm cable (3 Core/ 4 Core) |
| 4 | Multi Core Above 5 sqmm Upto 16 Sqmm |
| 5 | 3 Core/ 4 Core Above 20 sqmm Upto 35 Sqmm |
| 6 | 3 Core/ 4 Core Above 50 sqmm Upto 70 Sqmm |
| 7 | 3 Core/ 4 Core Above 95 sqmm Upto 185 Sqmm |
| 8 | Single core * 240 Sqmm |
| 9 | Laying of Conduit heavy gauge GI conduit surface run with GI saddles, or concealed including wall chases and complete with GI junction boxes, pull boxes, inspection boxes,bends & other accessories etc |
| 10 | 25mm GI Conduit |
| 11 | 40mm GI Conduit |
| 12 | laying of HDPE pipe DWC/Split DWC type, different sizes outer dia, for cable laid underground with necessary connecting sockets / couplings, tees below road / groundsurface, including excavation, back filling with excavated material with ramming and making the surface good |
| 13 | 40 mm - 80 mm |
| 14 | 100mm- 160mm |
| 15 | 200- 300 mm |
| 16 | Supply, fabrication & installation of perforated return flanged type cable trays with factory fabricated horizontal & vertical bends, reducers, tee\"s, cross overs and other accessories as required conforming to IEC-61537. The tray shall be hot dipped galvanized for corrosion protection conforming to IS 2629, DIN 267 Part 10, EN 10346, BS EN ISO 1461, GI return flanged cable trays with 150mm*50mm*2 mm thick GI sheets conforming to Technical Specifications and IS Code. The trays shall be tested for minimum safe working load and the deflection should be within the limits as per standard. All accessories including GI angles, threaded rods, fasteners, clamps etc shall be provided (or installed on wall supported on suitable brackets as required) complete as per specifications, as required and as below. |
| 17 | Supply, installation, testing and commissioning ofwall mounted, dust & vermin proof,L.T. Distribution board & Star Delta Pump Starter Panels with IP 66 rated of different capacities |
| 18 | LT switch board 63 Amp comprising items indicated as under,i) incoming MCCB 63A, 4 pole, 35kA, fixed type (Ics=100%Icu) - 1 Noii) Outgoing MCCB 40A, 4 pole, 25kA, fixed type (Ics=100%Icu) - 3 Nosiii) Outgoing MCB double pole, 6-32A, 10kA- 16 Nosiv) Outgoing MCB Single pole,6-32A, 10kA-8Nosv)Sleeved/Epoxy coated copper bus-bar 200 A in bus bar Chamber vi) CT\"s Indication lights |
| 19 | FABRICATION & SUPPLY OF 50HP STAR DELTA STARTER PANEL i. BOARD MADE OUT OF 16 SWG CRCA SHEET WITH SIEMENS GREY POWDER COATING ii. 100AMPS 3POLE MCCB – 1 NOSiii. 63 AMPS MNX 3POLE CONTACTOR – 2 NOSiv. 45 AMPS MNX 3POLE CONTACTOR – 1 NOSv. OLR 30.0AMPS TO 50AMPS – 1 NOSvi. ADD ON BLOCK (2NO + 2NC) – 3 NOSvii. ILL. PB STAR / STOP – 1 SETviii. TRIP INDICATOR – 1 NOSix. AMMETER / VOLTMETER – 1 SET x. MPR DRY RUN PROTECTION – 1 NOSxi. WATER LEVEL CONTROLLER AND WITH PROB – 1 SETxii. ACCESSORIES FOR WIRING xiii. TB – 12 NOSxiv. PANEL LOCKSxv. WITH TOTAL INTERNAL, CONTROL AND POWER WIRING |
| 20 | FABRICATION & SUPPLY OF25HP STAR DELTA STARTER PANEL i. BOARD MADE OUT OF 16 SWG CRCA SHEET WITH SIEMENS GREY POWDER COATINGii. 80 AMPS 3POLE MCCB – 1 NOSiii. 40 AMPS MNX 3POLE CONTACTOR – 2 NOSiv. 32 AMPS MNX 3POLE CONTACTOR – 2 NOSv. OLR 14.0AMPS TO 23AMPS – 1 NOSvi. ADD ON BLOCK 2NO + 2NC – 1 NOSvii. ADD ON BLOCK 1NO + 1NC – 2 NOSviii. ILL. PB STAR / STOP – 1 SETix. TRIP INDICATOR – 1 NOSx. AMMETER / VOLTMETER – 1 SET xi. MPR DRY RUN PROTECTION – 1 NOSxii. WATER LEVEL CONTROLLER AND WITH PROBE – 1 SETxiii. TB – 6 NOSxiv. PANEL LOCKSxv. WITH TOTAL INTERNAL, CONTROL,POWER WIRING |
| 21 | FABRICATION & SUPPLY OF 10HP STAR DELTA STARTER PANEL i. BOARD MADE OUT OF 16 SWG CRCA SHEET WITH SIEMENS GREY POWDER COATINGii. 32AMPS 3POLE MCCB – 1 NOSiii. 32 AMPS MNX 3POLE CONTACTOR – 2 NOSiv. 18 AMPS MNX 3POLE CONTACTOR – 1 NOSv. OLR 6.0AMPS TO 10AMPS – 1 NOSvi. ADD ON BLOCK 2NO + 2NC – 1 NOSvii. ADD ON BLOCK 1NO + 1NC – 2 NOSviii. ILL. PB STAR / STOP – 1 SETix. TRIP INDICATOR – 1 NOSx. AMMETER / VOLTMETER – 1 SET xi. MPR DRY RUN PROTECTION – 1 NOSxii. WATER LEVEL CONTROLLER AND WITH PROBE – 1 SETxiii. TB – 6 NOSxiv. PANEL LOCKSxv. WITH TOTAL INTERNAL, CONTROL, POWER WIRING |
| 22 | SECTION - B : EARTHING ARRANGEMENT & CONNECTIONS |
| 23 | SITC of plate earthing station with 600mm x 600 mm x 3 mm Cu plate electrode , 50 mm dia G.I.watering pipe, GI funnel with wiremesh all earth work, earth enhancing compound Material, masonry enclosure with frame, Heavy duty RCC top cover plate having locking arrangement,Disconnecting links, complete as required as per IS-3043:1987 for earthing.(Including civil work) |
| 24 | Supply and installation of 50 mm dia, 3mm thick Class \"C\" GI pipe electrode earth station conforming to IS 3043 (latest) complete with brick masonry chamber, heavy duty RCC cover, GI watering funnel with 20G GI wire mesh etc. Manhole cover with frame shall be painted with bitumastic paint, identification of earth pit with yellow paint top/below the chamber cover,with enchancing material around electrode for GI Pipe electrode including digging of pit up to permanent moisture level but not less than 3 mtr depth and back filling |
| 25 | Supply, laying of 50 mm X 6 mm GI strip for interconnecting the earthing stations ,panels,DBs etc. in built up trenches /surface/wall/ground complete with holes & fixing,jointing / terminating accessories |
| 26 | Supply, laying of 40 mm X 6 mm GI strip for interconnecting the earthing stations ,panels,DBs etc. in built up trenches/surface/wall/ground complete with holes & fixing,jointing / terminating accessories |
| 27 | Supply, laying of 25 mm X 6 mm GI strip for interconnecting the earthing stations ,panels,DBs etc. in built up trenches/surface/wall/ground complete with holes & fixing,jointing / terminating accessories |
| 28 | Section-C : Fire Fighting Systems Related Works |
| 29 | Supply, laying & fixing of GI pipe (C class)ISI standards to be followed along with accessories with Flange & weldingabove and below ground level and making the damages good. (GI pipe fabrication flange and bend welding and bolt, nut, rubber gasket fixing work) |
| 30 | 40- 80 mm Día GI Pipe |
| 31 | 100 -150 mm Día GI Pipe |
| 32 | 150mm- 250mm Dia GI pipe |
| 33 | Rewinding and installation Fire fighting pumps of all types of Electrical Motors with following capacities. |
| 34 | Three Phase, Upto 10 Hp |
| 35 | Three Phase, 75 Hp to 110 Hp |
| 36 | Overhauling of Fire fighting pumps with the following capacities including replacement of seals, bearings, oil, check nut, Stud,Packing gasket replacement & general service etc. as required. (Replacement of impeller to be on approval basis) |
| 37 | Three Phase, Upto 10 Hp |
| 38 | Three Phase, 75 Hp to 110 Hp |
| 39 | Fire Diesel Engine B Complete B Check- 75 KW to 85 KW including all consumables from OEM authorized Vendor. |
| 40 | Section-D : CIVIL RelateditsWorks for E&M Enabling Works |
| 41 | Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including disposal of excavatedearth upto 50 m and lift upto 1.5 m, disposed soil to be levelled and neatly dressed : All Kind of soils |
| 42 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer- incharge.all kind of soil and for all kind of work. |
| 43 | Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kind of Soil |
| 44 | Removal and Reinstallation of Existing Paving Blocks for Cable Laying- Removing existing paving blocks, laying cables, and reinstating the blocks, including proper alignment, compaction, and surface restoration. |
| 45 | Core Cutting Works |
| 46 | Core Cutting on Existing RCC Structure and Block Work using Standard Core Cutting Machine of Size 100 to 200 mm Dia and depth of 150 to maximum 450 mm. |
| 47 | Core Cutting on Existing RCC Structure and Block Work using Standard Core Cutting Machine of Size 100 to 200 mm Dia and depth of 450 to maximum 800 mm. |
| 48 | Providing and Fixing Scaffolding Arrangemnt for E&M Works |
| 49 | Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after .The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineerin-charge .The elevational area of the scaffolding shall be measured for payment purpose .The payment will be made once irrespective of duration of scaffolding. Item will be Certified only for Maintenance Work carried out above 5 Mtr. |
| 50 | Section- D : Supply of Machinery with Operator and Fuel - Trip Sheet to be enclosed for all machineries |
| 51 | Hiring Charge of Hydraulic Excavator (3D) with Driver and fuel ( Minimum Hire charge will be for 4 Hours if usage is below 4 hours):- Utilization of Excavator (backhoe loader) for excavation tasks, including digging, soil removal, and site preparation.- Ensuring proper depth, alignment, and site clearance as required for installation and civil works. |
| 52 | Hiring Charge of Electrical Submersible ElectricalDewatering Pump of capacity 50 HP and Min 10,000 LPM/hr and Above including Starter panel and operator Charge. The rncludes the provision of the starter Panel at the specified locatio for efficient fluid transfer and operation its support during monsoon times for emergency dewatering purposes. |
| 53 | Hiring Charge of Diesel Dewatering Pump of capacity 4000 ltr/hr and Above including fuel and operator Charge.( Pump may be of any type and itscapacity should be above 4000 ltr/hr)The rate includedthe provision of the diesel and Operator for efficient fluid transfer and operation its support during monsoon times for emergency dewatering purposes. |
| 54 | Supply of Truck Mounted Boom lift of 120 ft Height for minimum 1 day to max 5 daysRental Charges for Boom Lift for Cable Laying or Light Fixing Work- Rental charges for a boom lift suitable for reaching heights above 40 feet, required for cable laying or light fixing works. This includes the provision of the boom lift at the specified location, ensuring it is operational and safe for the duration of the rental. The rental covers the equipment\"s availability, including necessary accessories and safety features for working at height. The service may also include basic operator training and maintenance support. |
| 55 | Section- E :New Parking areas Lighting including Minor Civil Works like pedesral for the pole,DB boxes, Earthing work. |
| 56 | Supply, Installation, Testing and Commissioning of LED Street Pole Light, IP 66 for parking area including supply and erection of 9 Mtr Street poles |
| 57 | Supply and Instalallationof 150/200W LED Pole Light, IP 66 |
| 58 | Supply and installation of StreetLight Pole9 Mtr |
| 59 | Supply and laying of 4 Core * 16 Sqmm Incoming Cable laying work in40 mmHDPE pipefurther making good as the same |
| 60 | supply and laying and 50mm HDPE pipe for cable laying |
| 61 | supplyand installation of50mm perforated cable tray |
| 62 | Supply and installation of Distribution Board (Incomer – 1 No 4P 63A MCB, Sub Incomer – 3 No’s DP 32A MCB, Outgoing – 5 No’s 6A MCB in each phase). |
| 63 | Construction of pedestral withsize of 2ft * 2ft depth 1 meter &Installation of J bolts & Nuts for street pole size- M20 with earth excavation & refilling work |
| 64 | Supply and installation of Ring Armincluding fabrication work |
| 65 | SECTION-F :Manpower for E&M Enabling Works |
| 66 | Electrician |
| 67 | Fitter-I CLASS |
| 68 | Welder |
| 69 | Plumber |
| 70 | Mason |
| 71 | Coolie/ Mazdoor |
| 72 | Painter |
| 73 | SECTION-E : Micellenous Items |
| 74 | Hiring Charges for Decorative Serial Lights per day basis |
| 75 | 1. Static LED strings |
| 76 | 2. Dynamic LED strings |
| 77 | Pickup vehicle for material transportation. |
| 78 | Rewinding, Maintenance, and Repair Work of various exhaust and pedestal fan, The works involves motor rewinding, bearing replacement, capacitor replacement, and shaft machining as needed. Upon completion of the repair work, all fans will undergo thorough testing to ensure they meet functional and safety standards form OEM authorized service provider |
| 79 | Exahust Fans |
| 80 | 1.315 mm Dia Exahust Fan |
| 81 | 2. 500mmDaia Exhaust Fan |
| 82 | Pedestral/ Wall Mounted Fans |
| 83 | 1. 450mm fans |
| 84 | 2. 600m Fans |
| 85 | 3. 750 mm Fans |